Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-01261, 07-1045
RM113 100WP4 WF0893287 / 001 City of'College Station PAGE 1 REQ. DATE: 04/27/07 04/27/07 13:38:25 LOCATION: 4100 MCLISTER DR LOC ID: 208540 REQUESTOR: STYLECRAFT BUILDERS INC ORIGIN: CUSTOMER -WALK IN REQ USER: NCOCHRAN AUTH USER:NCOCHRAN WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07 ******************************************************************************** JOB ORDER RESULT COW4ENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . 8/09/07 579530-0208-0010 4100 MCLISTER DR COLLEGE STATION TX 77845 SOUTHERN TRACE PH 2 SOUTHERN TRACE SUB PH 2 BLK 8 LOT 1 SINGLE FAMILY RESIDENTIAL STYLECRAFT BUILDERS 979 690-1222 07-00001261 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX BuiTdinVofficial VOID UNLESS SIGNED BY BUILDING OFFICIAL Date: 8/8/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1261 Address: 4100 MCLISTER DR Type Inspection Type Code Description siatps Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 05/01/2007 03:41 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Raining, slab covered with plastic. B100 BLDG, FOUNDATION -SLAB IC 05/04/2007 10:16 AM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B115 BLDG, FRAMING IC June 21, 2007 1:56:35 PM kwolfe. 13115 BLDG, FRAMING IC eddie called in and cancelled B115 BLDG, FRAMING IC 06/27/2007 10:30 AM RH PDA B115 BLDG, FRAMING IC Anchor at front door. Add hilti shots on storage room 13115 BLDG, FRAMING IC wall. Joist hanger at RTA. Secure loose plug at kitchen by B115 BLDG, FRAMING IC insulation inspection. E110 ELEC, ROUGH IN IC 06/19/2007 02:37 PM RH PDA E110 ELEC, ROUGH IN IC Need plug outlets outside bedrooms by framing inspection. P100 PLBG, ROUGH IN IC April 27, 2007 4:01:05 PM kwolfe. Page 1 (8/9/2007) Gina Southerland -"Re" Calling for CO @ 4100�Mclister Dr � � � � � Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 8/8/2007 4:06 PM Subject: Re: Calling for CO @ 4100 Mclister Dr All ok. Paul >>> Kim Wolfe 8/8/2007 12:08 PM >>> any issues? BP # 07-1261 Thanks Kimberly Wolfe, CPS/CAP City of College Station Planning & Development Services (979) 764-3570 www.cstx.gov PREPARED 8/08/07, 12:00:49 INSPECTION TICKET PAGE 10 City of College Station INSPECTOR: BUILDING INSPECTOR DATE' 8/08/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 4100 MCLISTER DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 579530-0208-0010 APPL NUMBER: 07-00001261 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/01/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 5/01/07 DA April 30, 2007 10:43:08 AM ncochran. 05/01/2007 03:41 PM RH PDA Raining, slab covered with plastic. B100 02 5/04/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 5/04/07 AP May 2, 2007 3:31:43 PM ncochran. 05/04/2007 10:16 AM RH PDA Strings up, slab ground installed. B115 01 6/21/07 BI BLDG, FRAMING TIME: 17:00 6/21/07 CA June 21, 2007 10:46:20 AM glsouth. June 21, 2007 1:56:35 PM kwolfe. eddie called in and cancelled B115 02 6/27/07 RH BLDG, FRAMING TIME: 17:00 6/27/07 AE June 26, 2007 4:01:09 PM acarter. 06/27/2007 10:30 AM RH PDA Anchor at front door. Add hilti shots on storage room wall. Joist hanger at RTA. Secure loose plug at kitchen by insulation inspection. B130 01 6/28/07 RH BLDG, INSULATION TIME: 17:00 6/28/07 AP June 28, 2007 10:21:39 AM glsouth. B132 01 7/05/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00 7/05/07 AP July 5, 2007 8:20:33 AM acarter. B125 01 8/08/�J7 I BLDG, FINAL TIME: 17:00 `KJXA August 8, 2007 9:01:44 AM kwolfe. -------------------------------------- COMMENTS AND NOTES -------------------------------------- Fz �/ eov AREA 1Y111R [I FMSHING NOTES SUMMARY _ _ 1 Optional Tile Package 2 Optional Appliance Package w Ln w '4 V, Mo OOC-1r- C�O'1w_ More Home, Less Money 2900. °°�M`� ©© PORCH ------------------------- i U¢ U O C�� STORAGE ,aag■ 4-1 I na rr I OO�'CY.¢�l —lam ®BATH3 w W ~ DINING W� ? �QD>pE¢Ha. U0(-00rL ,0'-19 8'-9• -- O C/]Z - dUanF Q BEDROOM 4 LOCATION 17-v x lz-0• SUBDIV. ST PHASE 02 LI9 c BLOCK 08 9�s ,s<• ii I LOI ' 1 BEDROOM 3 KITCHEN 3 "' / Q wwe O O WIC IS EI �_ BA�TH2 N FOYER O T W N BEDROOM t —�— g� WI BEDROOM 2 U ,z-0• . ,r-0 e-0 �I ,r-0• x ,r-0• I U V F7� , y PORCH I �� C/� % rs BUILDING FOOTPRINT I ' 0 /W� O • 26'Sx44�-,o L------------' COMMENTS E-� W (� a � O 90 F-1 } o U a 1 ST PLAN PREVIEW ND PLAN PREVIEW SCALE:3/32'=1'-0' 2SCALE:3/32'=1'-0" o NOTICE THIS SET OF DRAWINGS FOR A HOME IS THE (� COPYRIGHTED PROPERTY OF SMECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND �1 NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL W OR ANY PORTION OF THE LICENSED PLANS IS M GRANTED, EITHER EXPRESSLY OR IMPLIED. F�-1 ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS ® O INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS ruji AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, ® z s $E ® DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER 0 Q Z Ca F= WITHOUT THE WRITTEN PERMISSION OF THE DESIGNERS. ® W O E- Ws �€ W W 0o 00 > 00 e� SHEET: CFRONT ELEVATION SCALE:3/32"=1'-0" G- I COVER SHEET SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 CABINET LAYOUT A-3 PLAN APPROVAL APPROVED INITIALS DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / AREA SUMMARY rw a. con u. cn a� �ry M 0000-7 lJ2cncn cw_ 12.5' REAR PLIE `O x U Q U (�NCn SETBAC --- ' � a ¢<— j \'IRE�EEAAR i OO¢QW� I �wOW�¢¢ I 1: " ;" F-,Ha ZUOOF�000. LOCATION I I I ' I I SUBDIV. ST PHASE 02 m m BLOCK 08 1490 � NI w1 SF W 1n• o d- ❑1 a fA� a. 10 .jtn. in r-1 Q I I I - I I I • I 1 I I II 11 F-�i N { I •I 4 E-1 1I {I II I1I I ' I I I'I o I 14 Q ZA Nt I w w I^/FRN S TBAC 4100 MCLISTER DRIVE E:" z pq fl SOUTHERN TRACE 36i?2, �D s5 ON 'sus 11 LK BLOCK - 8 Qi 84�SF PHASE - 2 U In — �' e _ W 4100 MCLISTER Z 0 U - E QOUe� U > �e 1 SITE PLAN SHEET: C _ 1 SCALER=20'-0" STTE PLAN From:STYLECRAFT BUILDERS INC 979 690 0348 06/06/2007 11:30 #399 P.002/002 To Whom This May Concern: I'm am writing this letter on behalf of Stylecraft Builders, Inc. in order to inform you of a change on the f VAC permit of our jobs at 4100 McLister. We originally listed Three Rivers to do this project, and it has since been changed to Control Temp. Please let me know if there is anything further needed from me, and I am sorry for any inconvenience this may have caused. Thank you, l Eric Wivagg Stylecraft Builders, Inc. BUILDING PERMIT CITY OF COLLEGE STATION r 1101 TEXAS AVE ` COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #: Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner ------------------------ --------------------- Structure Construction Type . . . . . Occupancy Type . . . . . . Other struct info . . . . . 07-00001261 120149 4100 MCLISTER DR 579530-0208-0010 Date 4/26/07 RESIDENTIAL, 1 UNIT DETACHED NEW SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 101574 Contractor ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 Information 000 000 ---------------------- COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1710.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc KW Permit pin number 497586 Permit Fee . . . . 466.00 Plan Check Fee .00 Issue Date . . . . 4/26/07 Valuation . . . . 101574 Expiration Date . . 10/23/07 Qty Unit Charge Per Extension BASE FEE 460.00 2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT ---------------------------------------------- ------ ---------- BUILDING DEPT REPRES TA�1VE- - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001261 Date 4/26/07 Application pin number . . . 120149 ---------------------------------------------------------------------------- Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ---------------------------------------------- ----A ��--------- BUILDING DEPT REP R,E'SENtAT:LVE : IJ a APPLICANT: d `� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 3 Application Number . . . . . 07-00001261 Date 4/26/07 Application pin number . . . 120149 ---------------------------------------------------------------------------- Special Notes and Comments ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ------------------------------------------------�-- . c;----------- BUILDING DEPT REPRESE/YTA-ICE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001261 Date 4/26/07 Application pin number . . . 120149 ---------------------------------------------------------------------------- Special Notes and Comments AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 466.00 466.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1216.00 1216.00 .00 .00 - APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001045 604175 4100 MCLISTER DR 579530-0208-0010 Date 4/26/07 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc KW Permit pin number 497594 Permit Fee . . . . 20.00 Issue Date . . . . 4/26/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------------------------------- ---- i- - '---------- BUILDING DEPT REPRE1 I�TIII E : APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning & Development Services WWW CSTX.GOV ADDRESS/LOCATION: LOT I V BLOCK V 1z ✓ For Office se only DATt: I C EG APPLICATION # law I TEMP POLE # C`lOZ DIVISION SOUTHERN TRACE SEC/PH 2 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing HVAC: To Be Determined GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing Less Slab STRUCTURE USE: Single Family Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS ❑ ENGINEERED �X HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 101;574"L'ess Slab —1 TOTAL AREA: 1949 HEATED AREA: 1710 (Cost of Labor and Materials) - PUBLIC SEWER NUMBER OF BEDROOMS: 4 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 4 SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE ® WATER TAP: %11 EXTERIOR WALL TYPE: Siding and/or Masonry SIZE OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE TEMP POLE ROOF TYPE: Composition GARAGE TYPE: SINGLE F—] DOUBLE TRIPLE ATTACHED rJAC.HED CARPORT SIGNATURE OF APPLICANT: TtI10-7 For St lecraft *If proposed work involves new commercia const on or faca a improve is/renovations to an existing commercial property, building elevations are require . ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ Official Use Only ov Plans Examiner Zoning Official C ents: rNO Energy Code Compliance Information % Glazing of exterior walls 12 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER Rating 13 0 I PLAN REVIEW -.ONE-and-Tl G.FAMIL,Y,OCCUjPANC3(-REQU1REMENTSM--__' �. .E CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D r DATE: BUILDING ADDRESS: 0 � file- L-i s%e iZ t:-foundation Re ulrernents-. Minimum -City..Foundation Standards-:.--.__.:..-._*_____:__.. _ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated IbWOK II. Framing: Floor, Wall, Coiling and Roof Requirements NA/ A. Girder or sill dimensionsgrade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck IMOK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist sizespacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter sizespacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE.and.-WV -F LY-MC— IPAtVQY,-R.EQi1IREMEt+T4: CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements _ - --- -�----____._ OK K A. Stairway Details N -I.-.,Maximum riser hei ht 7.-3/4 inches 2 Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements JlQ0K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V.__Electrical SorvLce Requirements A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location f 7 PLAN REVIEW ONE. and�TWOIFAMILY-;OCCUPA14CY=REQUIREMENTS".:= - -: CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure -reducing valve required when water pressure exceeds 80 psi _.._ N - _ B. Plumbing access to bathtubs - C. Means for thermal expansion provided when required D._,Water heaters elevated-18" when installed- irvthe-garage-or- roomr-directloff garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) 7 B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for comer lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER 3 •Z1/--ID7 DATE .. 'k REScheck Software Version 4.0.1 Compliance Certificate Project Title: 1690 Plan Report Date: 03/16/07 Data filename: \\STYLECRAFT1\Share\ACAD\RESCheck\1690.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x120 979-690-1222 x120 ewivagg@stylecraft-builders.com ewivagg@stylecraft-builders.com . Maximum SHGC: 0.40 Your SHGC: 0.40 vveu is vvoou rrame, ib.. o.c.: 1136 13.0 0.0 79 Window 1: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 10 Twin: Metal Frame:Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Window 10 Twin: Metal Frame: Double Pane with Low-E: 16 0.670 11 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: 981 13.0 0.0 73 Window 11: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 13 0.670 9 1690 Plan Page 1 of 2 i 1 � SHGC: 0.40 Window 15: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 18: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 19: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 20: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 21: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 22: Metal Frame:Double Pane with Low-E: 6 0.670 4 SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Window 23 Twin: Metal Frame:Double Pane with Low-E: 13 0.670 9 SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: 25 19.0 0.0 1 Ceiling 2: Flat Ceiling or Scissor Truss: 867 19.0 0.0 44 Floor 1: Slab -On -Grade: Unheated: 869 0.0 905 Insulation depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Unconditioned Space: 24 13.0 0.0 2 Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requireme ted in the REScheck Inspection Checklist. -JSk 57W E-e,z-AF-1- 3 11610 7 Name -Title Signature Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1690 Plan Page 2 of 2