HomeMy WebLinkAboutRES2007-01251, 07-12524 f yl 1
007* la 15A
WFOB94090 / 001 City of College ,9tat�,on
PAGE 1
REQ. DATE: 04/30/07 04/30/07 16:40:34
LOCATION: 2808 HORSEBACK DR LOC ID: 208668
REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/30/07 SCHED COMPLETION: 04/30/07
********************************************************************************
JOB ORDER RESULT COMYIENTS
PREPARED 8/23/07, 8:07:17 INSPECTION TICKET PAGE 10
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/22/07
ADDRESS 2808 HORSEBACK DR'"r SUBDIV: HORSE HAVEN PH 3
CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504
OWNER . . PHONE
PARCEL . . 336300-0303-0080
APPL NUMBER: 07-00001251 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT_ BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/01/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00
6/01/07 AP June 1, 2007 9:36:03 AM kwolfe.
B115 01 7/12/07 DS BLDG, FRAMING TIME: 17:00
7/12/07 AE July 11, 2007 4:01:16 PM kwolfe.
07/12/2007 03:53 PM DS PDA
small fireblocking left of frontdoor
brace under perlin in garage over 4'
B130 01 7/17/07 OC BLDG, INSULATION TIME: 17:00
7/17/07 AP July 16, 2007 1:12:19 PM acarter.
B125 01 8/2 /07 BLDG, FINAL TIME: 17:00
August 22, 2007 2:45:57 PM kwolfe.
Af
----------------------------L'---- CONTINUED ONTO NEXT PAGE -----------------------------------
105. 411 S 88023' 46" W
3„ 81_�3„ 1„
r-23'-4"-----28'-7�, 12 —5` — — 32— BOO
N 0 U. E.0-
Q
281-2
6'Q /
41
A /
7-9
��—
Cfl ' W 1ItoVALi !!
P 5. B
CD
iUn-' CU
C12�""
34- 81'
OWNER:
STAMFORD
SITE PLAN
SCALE: 1"= 20'
2808 HORSEBACK DRIVE
W
M
0
0
00
00
(u
i
00
cu
c�
cu
0
0
0
LOT: 8 HORSE HAVEN
BLOCK: 3 COLLEGE STATION, TEXAS
SECTION: 3
BUILDER:
OAKWOOD CUSTOM HOMEBUILDERS LLC
a
G:%0AK_DWGV*M HAVEN\H—whack DrimrXMHH&C-melo[-n odFY_FPlALDWG, Modd, 04/23/2007 04:5733 PM,
AAnAl or, Adobe PDF let-HQAc3, tether, 1240
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001252 Date 4/30/07
Application pin number . . . 553964
Property Address . . . . . . 2808 HORSEBACK DR
Property ID: 336300-0303-0080
Application type description TEMP POLE
Subdivision Name . . . . . . HORSE HAVEN PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
---------------------- �� ------------------------
OAKWOOD CUSTOM HOMES
O 4060 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1504
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . GS
Permit pin number . 499566
Permit Fee . . . . 20.00
Issue Date . . . . 4/30/07 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Other Fee Total 45.00 45.00 .00 .00
Grand Total 65.00 65.00 .00 .00
-- --- - --- -------------------
BUILDING DEPT REPRESENTATIVE: �.
APPLICANT:
BU-.LDING PERMIT
CITY C. COLLEG2 STATION
01 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . .
Application pin number . .
Property Address . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
07-00001251
468857
2808 HORSEBACK DR
336300-0303-0080
Date 4/30/07
RESIDENTIAL, 1 UNIT DETACHED NEW
HORSE HAVEN PH 3
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
134000
Owner
Contractor
------------------------
------------------------
OAKWOOD CUSTOM HOMES
4060 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1504
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1684.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 225.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
499558
Permit Fee . . . .
562.00 Plan Check Fee .00
Issue Date . . . .
4/30/07 Valuation . . . . 134000
Expiration Date . .
10/27/07
Qty Unit Charge
Per, Extension
BASE FEE 460.00
34.00 3.0000
THOU BLDG, VAL 100001-500000 102.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN-ARC-FAUL CIR IT
---------------------------------------------
BUILDING DEPT REPRESENT�IV,�:
------- ------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001251
Application pin number . . . 468857
Page 2
Date 4/30/07
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
--`------------
BUILDING DEPT REPRESENTATIVE: J60T
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1j01 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001251 Date 4/30/07
Application pin number . . . 468857
----------------------------------------------------------------------------
Special Notes and Comments
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR. Make sure hallway smoke
detector is at least 3' from Return Air
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT
- --E EED 4
-
-----------------------------------
---- ----��-- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGt STATION
. 11b1 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001251
Application pin number . . . 468857
Page 4
Date 4/30/07
Special Notes and Comments
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed
Other Fees SEWER TAP 4"
WATER TAP 3/4"
350.00
400.00
Fee summary
Charged
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
----------
562.00
562.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1312.00
1312.00
.00
.00
-
APPLICANT:
APPLICATION FOR WILDING PERMIT
CITY OF COLLEGE STATION
I 101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 7643570 (979) 764-U96 FAX
Planning&Dr IopmentSrrvint VW1IW.CSTX.GOV
ADDRESS/LOCATION:
111
For Oftp use any
DATE: I IYKUU REG
APPLICATION #
TEMP POLE #
LOT 8 ✓ BLOCK 3 Vol'SUBDIVISION HORSE HAVEN ESTATES
SEC/PH
BUSINESS/OWNER NAME: ALTON OFCZARZAK
PHONE 979-690-1504
CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-6904504
CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845
ELECTRICIAN: CAMPISE ELECTRIC PLUMBER: AGGILAND PLUMBING
HVAC: THREE RIVERS GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF,WORK: NEW CONSTRUCTION
STRUCTURE USE: SINGLE FAMILY RESIDENTIAL
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (T PROJECT REGISTRATION# EABPRJ
VALUATION: $ 000 _ TOTAL AREA: 2341 _ HEATED AREA: 1684
(C of Labor and Materials)
DX PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
QX SEWER TAP:
MX WATER TAP:
OTHER TAP:
0 TEMP POLE
GARAGE TYPE:
4" SIZE
SIZE
SIZE
SINGLE
ATTACHED
SIGNATURE OF APPLICAN
*If proposed work involves no
commercial property, building
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
4
3
2X4 @ 16
2X4 Q 16 W/ BRICK
FOUNDATION TYPE: SLAB & BEAM
ROOF TYPE: 25 YR COMP.
DOUBLE F_X_j TRIPLE E]
IETACKD F-1 CARPORT
r-1.-1/— - - — —
ruction or facade improvements/renovations to an existing
gjjdns are required.
Official Use Only
Tip LI-0--07
_� (rk//H
Comments.
or NO
r
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 12% /
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 (flat areas) R30 /
Insulation R value of ceiling 2 (vaulted areas/no attic) R19 /
Glazing SHGC .30
Glazing U-Factor .54
R value of ductwork R6
A/C SEER Rating 13
4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
0`1 - �� sl
DATE:
- 07
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
O
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
WVOK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
k
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
K
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
i
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NAPV
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
&PK
"APPROVED PLANS PER IRC SECTION R106.3.1."
LPIL-K48 EXAMINER
DATE
w
CREScheck Software Version 4.0.1
NJ( Compliance Certificate
Project Title: HORSEHAVEN LOT 8, BLK 3, PH3
Report Date: 04/23107
Data filename: G:\OAK_DWG\HORSEH-3\HORSEB-1\HH1-27-1.RCK
Energy Code: 2003 IIECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 12%
Heating Degree Days: 1788
Construction Site:
Owner/Agent:
Designer/Contractor:
2808 HORSEBACK DRIVE
ALTON OFCZARZAK
David Park
College Sataion, TX 77845
OAKWOOD CUSTOM HOMES GROUP
OAKWOOD CUSTOM HOMES GROUP
LTD.
LTD. HOME PLAN DESIGN SERVICE
4060 HWY. 6 SOUTH
4060 Highway 6 South
COLLEGE STATION, TX 77845
College Station, TX 77845
979-690-1504
979-690-1504
PLANS@OAKCHB.COM
plans@oakchb.com
Coiiipliance'Passes L.MMamurii UA 589=uYour Home'UA`. 461, >,21':7% Better.Than Code (UA)
k - i • i Yom SHGC: 0.30
Ceiling 1: Flat Ceiling or Scissor Truss:
Wall 1: Wood Frame, 16" o.c.:
121050 sidelite X2: Metal Frame:Double Pane with Low-E:
SHGC: 0.30
3008HS: Metal Frame:Double Pane with Low-E-.
SHGC: 0.30
3050SH X6: Metal Frame:Double Pane with Low-E:
SHGC: 0.30
3650SHX2: Metal Frame:Double Pane with Low-E:
SHGC: 0.30
4060EYEBROW SH X 2: Metal Frame:Double Pane with Law-E:
SHGC: 0.30
6010transom: Metal Frame:Double Pane with Low-E:
SHGC: 0.30
3068 FRONT DOOR: Solid:
2868 BACK DOOR: Solid:
2868 TO GARAGE: Solid:
CONC. SLAB: Slab-On-Grade:Unheated:
Insulation depth: Off
Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER
1650 0.0
3u.0
a
1558 13.0
0.0
107
10
0.540
5
4
0.540
2
90
0.540
49
35
0.540
19
48
0.540
26
6
0.540
3
20
0.140
3
18
0.140
3
18
0.140
3
182
0.0
190
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature
Project Notes:
LOT 8, BLOCK 3, PHASE 3 HORSEHAVEN ESTATES
2808 HORSEBACK DRIVE
HORSEHAVEN LOT 8, BLK 3, PH3
Date
Page 1 of 4
CREScheck Software Version 4.0.1
NJ/ Inspection Checklist
Date: 04/23/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ 121050 sidelite X2: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes
No
Comments:
❑ 3008HS: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes
No
Comments:
❑ 3050SH X& Metal Frame:Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes
No
Comments:
❑ 3650SHX2: Metal Frame:Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes
No
Comments:
❑ 4060EYEBROW SH X 2: Metal Frame:Double Pane with Low-E, U-factor. 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes
No
Comments:
❑ 6010transom: Metal Frame:Double Pane with Low-E, U-factor: 0.540
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes
No
Comments:
Doors:
❑ 3068 FRONT DOOR: Solid, U-factor: 0.140
Comments:
❑ 2868 BACK DOOR: Solid, U-factor: 0.140
Comments:
❑ 2868 TO GARAGE: Solid, U-factor. 0.140
Comments:
Floors:
HORSEHAVEN LOT 8, BLK 3, PH3
Page 2 of 4
❑ CONC. SLAB: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER or higher
Make and Model Number.
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values, glazing U-factors, and cooling equipment efficiency are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R value without compressing the insulation.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building are insulated to R-8.
❑ Return ducts in unconditioned attics or outside the building are insulated to R-4.
❑ Supply ducts in unconditioned spaces are insulated to R-6.
❑ Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in
basements.
❑ Where exterior walls are used as plenums, the wall is insulated to R-8.
Duct Construction:
❑ Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened.
❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181 A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
❑ The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pods have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
HORSEHAVEN LOT 8, BLK 3, PH3 Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness In Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
Temperature ("F)
170-160
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2. Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
d Temp.
Rang (F)
2" Runouts 1" and Less
1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
HORSEHAVEN LOT S, BLK 3, PH3 Page 4 of 4