Loading...
HomeMy WebLinkAboutRES2007-01251, 07-12524 f yl 1 007* la 15A WFOB94090 / 001 City of College ,9tat�,on PAGE 1 REQ. DATE: 04/30/07 04/30/07 16:40:34 LOCATION: 2808 HORSEBACK DR LOC ID: 208668 REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/30/07 SCHED COMPLETION: 04/30/07 ******************************************************************************** JOB ORDER RESULT COMYIENTS PREPARED 8/23/07, 8:07:17 INSPECTION TICKET PAGE 10 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/22/07 ADDRESS 2808 HORSEBACK DR'"r SUBDIV: HORSE HAVEN PH 3 CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504 OWNER . . PHONE PARCEL . . 336300-0303-0080 APPL NUMBER: 07-00001251 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT_ BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/01/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00 6/01/07 AP June 1, 2007 9:36:03 AM kwolfe. B115 01 7/12/07 DS BLDG, FRAMING TIME: 17:00 7/12/07 AE July 11, 2007 4:01:16 PM kwolfe. 07/12/2007 03:53 PM DS PDA small fireblocking left of frontdoor brace under perlin in garage over 4' B130 01 7/17/07 OC BLDG, INSULATION TIME: 17:00 7/17/07 AP July 16, 2007 1:12:19 PM acarter. B125 01 8/2 /07 BLDG, FINAL TIME: 17:00 August 22, 2007 2:45:57 PM kwolfe. Af ----------------------------L'---- CONTINUED ONTO NEXT PAGE ----------------------------------- 105. 411 S 88023' 46" W 3„ 81_�3„ 1„ r-23'-4"-----28'-7�, 12 —5` — — 32— BOO N 0 U. E.0- Q 281-2 6'Q / 41 A / 7-9 ��— Cfl ' W 1ItoVALi !! P 5. B CD iUn-' CU C12�"" 34- 81' OWNER: STAMFORD SITE PLAN SCALE: 1"= 20' 2808 HORSEBACK DRIVE W M 0 0 00 00 (u i 00 cu c� cu 0 0 0 LOT: 8 HORSE HAVEN BLOCK: 3 COLLEGE STATION, TEXAS SECTION: 3 BUILDER: OAKWOOD CUSTOM HOMEBUILDERS LLC a G:%0AK_DWGV*M HAVEN\H—whack DrimrXMHH&C-melo[-n odFY_FPlALDWG, Modd, 04/23/2007 04:5733 PM, AAnAl or, Adobe PDF let-HQAc3, tether, 1240 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001252 Date 4/30/07 Application pin number . . . 553964 Property Address . . . . . . 2808 HORSEBACK DR Property ID: 336300-0303-0080 Application type description TEMP POLE Subdivision Name . . . . . . HORSE HAVEN PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ---------------------- �� ------------------------ OAKWOOD CUSTOM HOMES O 4060 SH 6 S COLLEGE STATION TX 77845 (979) 690-1504 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 499566 Permit Fee . . . . 20.00 Issue Date . . . . 4/30/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 -- --- - --- ------------------- BUILDING DEPT REPRESENTATIVE: �. APPLICANT: BU-.LDING PERMIT CITY C. COLLEG2 STATION 01 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . Application pin number . . Property Address . . . . . Property ID: R #• Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Application valuation . . . 07-00001251 468857 2808 HORSEBACK DR 336300-0303-0080 Date 4/30/07 RESIDENTIAL, 1 UNIT DETACHED NEW HORSE HAVEN PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 134000 Owner Contractor ------------------------ ------------------------ OAKWOOD CUSTOM HOMES 4060 SH 6 S COLLEGE STATION TX 77845 (979) 690-1504 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1684.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 225.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 499558 Permit Fee . . . . 562.00 Plan Check Fee .00 Issue Date . . . . 4/30/07 Valuation . . . . 134000 Expiration Date . . 10/27/07 Qty Unit Charge Per, Extension BASE FEE 460.00 34.00 3.0000 THOU BLDG, VAL 100001-500000 102.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN-ARC-FAUL CIR IT --------------------------------------------- BUILDING DEPT REPRESENT�IV,�: ------- ------------ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001251 Application pin number . . . 468857 Page 2 Date 4/30/07 Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. --`------------ BUILDING DEPT REPRESENTATIVE: J60T APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1j01 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 07-00001251 Date 4/30/07 Application pin number . . . 468857 ---------------------------------------------------------------------------- Special Notes and Comments REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR. Make sure hallway smoke detector is at least 3' from Return Air PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT - --E EED 4 - ----------------------------------- ---- ----��-- ------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGt STATION . 11b1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001251 Application pin number . . . 468857 Page 4 Date 4/30/07 Special Notes and Comments ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Narrow Wall Bracing Fully Sheathed Other Fees SEWER TAP 4" WATER TAP 3/4" 350.00 400.00 Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 562.00 562.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1312.00 1312.00 .00 .00 - APPLICANT: APPLICATION FOR WILDING PERMIT CITY OF COLLEGE STATION I 101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 7643570 (979) 764-U96 FAX Planning&Dr IopmentSrrvint VW1IW.CSTX.GOV ADDRESS/LOCATION: 111 For Oftp use any DATE: I IYKUU REG APPLICATION # TEMP POLE # LOT 8 ✓ BLOCK 3 Vol'SUBDIVISION HORSE HAVEN ESTATES SEC/PH BUSINESS/OWNER NAME: ALTON OFCZARZAK PHONE 979-690-1504 CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-6904504 CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845 ELECTRICIAN: CAMPISE ELECTRIC PLUMBER: AGGILAND PLUMBING HVAC: THREE RIVERS GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF,WORK: NEW CONSTRUCTION STRUCTURE USE: SINGLE FAMILY RESIDENTIAL HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (T PROJECT REGISTRATION# EABPRJ VALUATION: $ 000 _ TOTAL AREA: 2341 _ HEATED AREA: 1684 (C of Labor and Materials) DX PUBLIC SEWER SEPTIC/TREATMENT SYSTEM QX SEWER TAP: MX WATER TAP: OTHER TAP: 0 TEMP POLE GARAGE TYPE: 4" SIZE SIZE SIZE SINGLE ATTACHED SIGNATURE OF APPLICAN *If proposed work involves no commercial property, building NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: 4 3 2X4 @ 16 2X4 Q 16 W/ BRICK FOUNDATION TYPE: SLAB & BEAM ROOF TYPE: 25 YR COMP. DOUBLE F_X_j TRIPLE E] IETACKD F-1 CARPORT r-1.-1/— - - — — ruction or facade improvements/renovations to an existing gjjdns are required. Official Use Only Tip LI-0--07 _� (rk//H Comments. or NO r Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 12% / Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 / Insulation R value of ceiling 2 (vaulted areas/no attic) R19 / Glazing SHGC .30 Glazing U-Factor .54 R value of ductwork R6 A/C SEER Rating 13 4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0`1 - �� sl DATE: - 07 BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated O II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck WVOK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations k PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK K A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location i PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NAPV A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed &PK "APPROVED PLANS PER IRC SECTION R106.3.1." LPIL-K48 EXAMINER DATE w CREScheck Software Version 4.0.1 NJ( Compliance Certificate Project Title: HORSEHAVEN LOT 8, BLK 3, PH3 Report Date: 04/23107 Data filename: G:\OAK_DWG\HORSEH-3\HORSEB-1\HH1-27-1.RCK Energy Code: 2003 IIECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: 2808 HORSEBACK DRIVE ALTON OFCZARZAK David Park College Sataion, TX 77845 OAKWOOD CUSTOM HOMES GROUP OAKWOOD CUSTOM HOMES GROUP LTD. LTD. HOME PLAN DESIGN SERVICE 4060 HWY. 6 SOUTH 4060 Highway 6 South COLLEGE STATION, TX 77845 College Station, TX 77845 979-690-1504 979-690-1504 PLANS@OAKCHB.COM plans@oakchb.com Coiiipliance'Passes L.MMamurii UA 589=uYour Home'UA`. 461, >,21':7% Better.Than Code (UA) k - i • i Yom SHGC: 0.30 Ceiling 1: Flat Ceiling or Scissor Truss: Wall 1: Wood Frame, 16" o.c.: 121050 sidelite X2: Metal Frame:Double Pane with Low-E: SHGC: 0.30 3008HS: Metal Frame:Double Pane with Low-E-. SHGC: 0.30 3050SH X6: Metal Frame:Double Pane with Low-E: SHGC: 0.30 3650SHX2: Metal Frame:Double Pane with Low-E: SHGC: 0.30 4060EYEBROW SH X 2: Metal Frame:Double Pane with Law-E: SHGC: 0.30 6010transom: Metal Frame:Double Pane with Low-E: SHGC: 0.30 3068 FRONT DOOR: Solid: 2868 BACK DOOR: Solid: 2868 TO GARAGE: Solid: CONC. SLAB: Slab-On-Grade:Unheated: Insulation depth: Off Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER 1650 0.0 3u.0 a 1558 13.0 0.0 107 10 0.540 5 4 0.540 2 90 0.540 49 35 0.540 19 48 0.540 26 6 0.540 3 20 0.140 3 18 0.140 3 18 0.140 3 182 0.0 190 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Project Notes: LOT 8, BLOCK 3, PHASE 3 HORSEHAVEN ESTATES 2808 HORSEBACK DRIVE HORSEHAVEN LOT 8, BLK 3, PH3 Date Page 1 of 4 CREScheck Software Version 4.0.1 NJ/ Inspection Checklist Date: 04/23/07 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ 121050 sidelite X2: Metal Frame:Double Pane with Low-E, U-factor. 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 3008HS: Metal Frame:Double Pane with Low-E, U-factor. 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 3050SH X& Metal Frame:Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 3650SHX2: Metal Frame:Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 4060EYEBROW SH X 2: Metal Frame:Double Pane with Low-E, U-factor. 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 6010transom: Metal Frame:Double Pane with Low-E, U-factor: 0.540 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ 3068 FRONT DOOR: Solid, U-factor: 0.140 Comments: ❑ 2868 BACK DOOR: Solid, U-factor: 0.140 Comments: ❑ 2868 TO GARAGE: Solid, U-factor. 0.140 Comments: Floors: HORSEHAVEN LOT 8, BLK 3, PH3 Page 2 of 4 ❑ CONC. SLAB: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: ❑ Heat Pump 1: Air Source: 7.7 HSPF, 14 SEER or higher Make and Model Number. Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values, glazing U-factors, and cooling equipment efficiency are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building are insulated to R-4. ❑ Supply ducts in unconditioned spaces are insulated to R-6. ❑ Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. ❑ Where exterior walls are used as plenums, the wall is insulated to R-8. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened. ❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics are rated UL 181 A or UL 181 B. Exceptions: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: ❑ All heated swimming pods have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. HORSEHAVEN LOT 8, BLK 3, PH3 Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness In Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" Temperature ("F) 170-160 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2. Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes Piping System Types d Temp. Rang (F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) HORSEHAVEN LOT S, BLK 3, PH3 Page 4 of 4