HomeMy WebLinkAboutRES2007-01237, 07-1238m-tam �)
:�� r+• ,
I'. r
WF0893153 / 001 City of College Station PAGE 1
REQ. DATE: 04/27/07 04/27/07 11:43:35
LOCATION: 4131 MCFARLAND DR LOC ID: 208530
REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name
Legal Description
Property Zoning .
Owner . . . . . . .
Contractor . . . .
8/17/07
579530-0208-010
4131 MCFARLAND DR
COLLEGE STATION TX 77845
SOUTHERN TRACE PH 2
SOUTHERN TRACE SUB PH 2
BLK 8 LOT 10
SINGLE FAMILY RESIDENTIAL
STYLECRAFT BUILDERS
979 690-1222
Application number 07-00001237 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
Bu ding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 8/17/07,
8:03:04
INSPECTION TICKET
PAGE 3
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 8/16/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 4131 MCFARLAND DR
SUBDIV: SOUTHERN TRACE PH
2
CONTRACTOR STYLECRAFT BUILDERS
PHONE (979) 690-1222
OWNER
. .
PHONE
PARCEL
. . 579530-0208-010
APPL NUMBER: 07-00001237 RESIDENTIAL,
1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01
7/03/07
BI
BLDG,
FRAMING TIME: 17:00
7/03/07
CA
July
3, 2007 11:22:14 AM glsouth.
July
3, 2007 2:01:40 PM kwolfe.
B115 02
7/05/07
RH
BLDG,
FRAMING TIME: 17:00
7/05/07
AE
July
3, 2007 2:02:10 PM kwolfe.
07/05/2007
09:43 AM RH PDA
Add support for valley at furnace. Block floor
joist
ends.
Add nails to some areas of bottom plates
upstairs.
B130 01
7/06/07
RH
BLDG,
INSULATION TIME: 17:00
7/06/07
AP
July
6, 2007 11:08:13 AM kwolfe.
B132 01
7/09/07
RH
BLDG,
SHEETROCK FASTENER TIME: 17:00
7/09/07
AP
July
9, 2007 11:50:39 AM kwolfe.
B125 Ol
8/�6//Q7
/��/
BLDG, FINAL TIME: 17:00
August 16, 2007 3:55:49 PM glsouth.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
1XI
Date: 8/17/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1237
Address: 4131 MCFARLAND DR
Type
inspection Type Code
Description
status
Inspection Result Comments
13115
BLDG, FRAMING
IC
July 3, 2007 2:01:40 PM kwolfe.
13115
BLDG, FRAMING
IC
07/05/2007 09:43 AM RH PDA
13115
BLDG, FRAMING
IC
Add support for valley at furnace. Block floor joist
B115
BLDG, FRAMING
IC
ends. Add nails to some areas of bottom plates upstairs.
M100
MECH, ROUGH IN
IC
06/21/2007 04:47 PM RH PDA
M100
MECH, ROUGH IN
IC
Run and install all bathroom exhaust flex lines. Complete
M100
MECH, ROUGH IN
IC
drain line.
M100
MECH, ROUGH IN
IC
07/03/2007 02:32 PM RH PDA
M100
MECH, ROUGH IN
IC
Did not correct previous notes.
Page 1
AREA
FINISHING NOTES
SUMMARY
1 Notes
11
cn cn
"'
LJY11[R
_ _
_
00��N
�C':;
r-
'
More Home, Less Money
a
Qoc
Qc�^
¢Q
oQEQ•Qp(z
v'F
awpW¢WW
PORCH0'd8�-0"6.$.
LOCATION
I
FKI�TICHENDINING BEDROOM 3 BEDROOM 2
SUBDIV.
ST
x 1r-r 10'-3x1r-r 1r-0x 1r-r 17V x 1r-r
PHASE
02
BLOCK
08
POWDE
O
BATH'
I
0 E T ELOWBATHBEDROOM1
F15'-9x
eF R 13'-1' x I +ra I
I
O
ON
PORCH BEDROOM 4
U o
•.•
r-v-v 6-0•
BUILDING ENVELOPE
8,T
�♦
i
�J v
1 ~J,
v
a
39'-0• x 31'3• R
Q
I Q
L� z
QQ
COMMENTS
a
V
�a
0
U
��
a r
ST PLAN PREVIEW ND PLAN PREVIEW
'�
SCALE:3/32"=1'-0" SCALE:3/32"=1'-0"
NOTICE
O
_
THIS SET OF DRAWINGS FOR A HOME IS THE
COPYRIGHTED PROPERTY OF STYLECRAFT
BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND
NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL
OR ANY PORTION OF THE LICENSED PLANS IS
GRANTED, EITHER EXPRESSLY OR IMPLIED.
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THE DRAWING ARE
OWNED BY AND THE PROPERTY OF THE DESIGNERS
AND WERE CREATED, EVOLVED AND DEVELOPED
FOR USE ON AND IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS,
DESIGNS ARRANGEMENTS OR PLANS SHALL BE
FT Tl
® ® ®
QP
<
Q
Ca
Q
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR
CORPORATION FOR ANY PURPOSE WHATSOEVER
WITHOUT WRITTEN OF THE
F
a
W
Z
Q
F
W-
8
THE PERMISSION
DESIGNERS.
—
Q
V
�j
z
00
a,g
0
SHEET:
CFRONT ELEVATION
G-1
SCALE:3/32"=1'-0"
COVER SHEET
SHEET INDEX
COVER SHEET
G-1
GENERAL NOTES
G-2
SITE PLAN
C-1
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
DETAILS
S-3
BRACING PLAN
S-4
FRAMING PLAN
S-5
ROOF FRAMING PLAN
S-6
DECKING LAYOUT
S-7
ELEVATIONS
S-8
FRAMING DETAILS
S-9
ELECTRICAL PLAN
E-1
FLOOR PLAN
A-'L
FLOORING PLAN
A-2
CABINET LAYOUT
A-3
PLAN APPROVAL
APPROVED
INITIALS
DATE
ADMINISTRATOR
/
SUPERINTENDENT
/
CUSTOMER
/
AREA
SUMMAR
i I
2 'REAR SETBA
----- I e I
I I
I , .
.11
I 6 5 SF e E 59-8 8F I
I .WI
U
I. I zl
LL
i
I Imo. N
I I
I I IW.
I I ° Iz
It EW Lk
SOD\
46 �0 HT F 29A . 1086 sF I w l
"' 4131 MCFARLAND DRIVE
N ss A3. SOUTHERN TRACE
LOT - 10
BLOCK - 8
PHASE - 2
a
41 1 MCF . . . . . . .
i
1 SITE PLAN
SCALE) "=2V-0"
wo,
LOCATION
SHEET:
C-1
SITE PLAN
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 T Y,4S AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
--------------------- Structure
Construction Type . . . . .
Occupancy Type . . . . . .
Other struct info . . . . .
07-00001237 Date 4/27/07
209370
4131 MCFARLAND DR
579530-0208-010
RESIDENTIAL, 1 UNIT DETACHED NEW
SOUTHERN TRACE PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
102643
Contractor
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
Information 000 000 ----------------------
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
EXTERIOR WALL TYPE MASONRY
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 1728.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 4.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc KW
Permit pin number 498279
Permit Fee 469.00 Plan Check Fee .00
Issue Date 4/27/07 Valuation . . . . 102643
Expiration Date 10/24/07
Qty Unit Charge Per Extension
BASE FEE 460.00
3.00 3.0000 THOU BLDG, VAL 100001-500000 9.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
BUILDING DEPT REPRESS TIVE: 1A.- X.
APPLICANT: )5�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 ---------------
Application Number . . . . . 07-00001237
Application pin number . . . 209370
Page 2
Date 4/27/07
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
-
--------------- ----- ----------------------- ------ - - --- - -'-----------
BUILDING DEPT REPRESEN VE:
APPLICANT: "�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 07-00001237
Application pin number . . . 209370
Page 3
Date 4/27/07
Special Notes and Comments
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Other Fees . . . . . . . . .
Fee summary Charged
SEWER TAP 4"
WATER TAP 3/4"
350.00
400.00
Paid Credited Due
------------------------------
BUILDING DEPT REPRESS ,
7
APPLICANT: i
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
----------------- ----------
Permit Fee Total 469.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1219.00
Page
4
07-00001237
Date
4/27/07
209370
--------------------
469.00
----------
.00
.00
.00
.00
.00
750.00
.00
.00
1219.00
.00
.00
--------------------------------------------- ----- ---- ----- _ ----------
BUILDING DEPT REPRE ATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001238
290380
4131 MCFARLAND DR
579530-0208-010
Date 4/27/07
TEMP POLE
SOUTHERN TRACE PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit pin number
. 498287
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/27/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------
Fee summary
Charged
-----------------------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------------------- ---
BUILDING DEPT REPRESENT
n
APPLICANT:
APPLICATION FOR•BUILD,ING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning& Development Services WWW CSTX.GOV
For Office Use Only
C�
DATE: `-awq TRCC `REG
APPLICATION #
TEMP POLE #=`�(���
ADDRESS/LOCATION: LI)31 Mcr—AP--AV40 —1-zff
LOT /D BLOCK_ SUBDIVISION SOUTHERN TRACE SEC/PH 2
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing
HVAC: To Be Determined GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing Less Slab
STRUCTURE USE: Single Family Residence
WALL BRACING METHOD: PRESCRIPTIVE APA PORTAL FRAME W/ CSPS ❑ ENGINEERED �X
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A _
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ 102,643 Less -Slab TOTAL AREA: 1862 HEATED AREA: 1728
(Cost of Labor and Materials)
APUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 4"
SIZE
WATER TAP: %11
SIZE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
4
4.5
Sheet Rock
Siding and/or Masonry
OTHER TAP: FOUNDATION TYPE: Slab on Grade
SIZE
TEMP POLE ROOF TYPE: Composition
t GARAGE TYPE: SINGLE F--] DOUBLE F—] TRIPLE
ATTACHED TAC D CA PORT
SIGNATURE OF APPLICANT: 41/*2/07 For St lecraft
*If proposed work involves new commercial con st ctio acade imp vemen s/r ovations to an existing
commercial property, building elevations are required.
Official Use On y
Comments:
3 2% '--o -7 �z ')DrNO S
Plans Examiner Zoning Official
_,.,),Plans
1 U
Energy Code Compliance Information
% Glazing of exterior walls
10%
Insulation R value of exterior walls
R13
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40
Glazing U-Factor
.65
R value of ductwork
R6
A/C SEER Rating
13
PLAN REVIEW
ONE -and -TWO- FAMILY-00CAJPANCY REQUIREMENTS-.�.__._.:....�
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# ATE: 3 _ O
_. _ _ 7-71�. —
BUILDING ADDRESS: 1-31I AJl .
a Foundation Requirements- Minimum City -Foundation Standards
A. Concrete minimum compression strength of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier Emil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
Al
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
MOK
E. Header sizes indicated on plans
A/
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J. Roof framing Ian or elevation shown
K. Ceiling joist sizespacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter sizespacing, roof slope & purlin bracing if required to reduces an
O. Roofcovering
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q:-Tem eyed Glass required in all hazardous locations
FLAN REVIEW
ONE.and.TWaFAMILY 00C:�JPAcNC `'F EQUIRENIENT - -
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. StairwayRequirements
OK
_. K
A. Stairway Details
NAkUVJ
1..MBximum riser height 7.-3/4 inches. :.
2.- Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
XgOK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. -.Electrical Service Requirements -
A. Electrical plan to include:
1V
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
_. ONE-and-TWO•.FAMILIF=OCOtJPAN0- Y—REQUIREMENTS-
CITY OF OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure -reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
_----- _..__ _.D._ Water heaters elevated-18"-when installed -in -the- ara e-or-roon directly off garage -
-- -= -
VII. Mechanical Requirements
NAJOW
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
Nq/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for comer lots
Subdivision Regulations — Ordinance 690
NAZCW
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
.J/
PLANS EXAMINER
DATE
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: 1714 Plan
Report Date: 03/16/07
Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\1714.00-Master.rck
Energy Code:
2003 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
10%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Designer/Contractor:
College Station, TX 77845
Stylecraft Builders, Inc.
Stylecraft Builders, Inc.
4090 SH 6 South
4090 SH 6 South
College Station, TX 77845
College Station, TX 77845
979-690-1222 x120
979-690-1222 x120
ewivagg@stylecraft-builders.com
ewivagg@stylecraft-builders.com
Maximum SHGC: 0.40 Your SHGC: 0.40
Wall 1: Wood Frame, 16" o.c.:
1293 13.0
0.0
92
Window 1: Metal Frame:Double Pane with Low-E:
3
0.670
2
SHGC: 0.40
Window 2: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 3: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 4: Metal Frame: Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 5: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 6: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Window 7: Metal Frame:Double Pane with Low-E:
9
0.670
6
SHGC: 0.40
Window 8: Metal Frame:Double Pane with Low-E:
9
0.670
6
SHGC: 0.40
Window 9: Metal Frame:Double Pane with Low-E:
18
0.670
12
SHGC: 0.40
Door 1: Solid:
20
0.500
10
Door 2: Glass:
18
0.440
8
SHGC: 0.40
Wall 2: Wood Frame, 16" o.c.:
1025 13.0
0.0
77
Window 10: Metal Frame: Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 11: Metal Frame: Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 12: Metal Frame:Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 13: Metal Frame:Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 14: Metal Frame:Double Pane with Low-E:
20
0.670
13
SHGC: 0.40
Window 15: Metal Frame:Double Pane with Low-E:
20
0.670
13
1714 Plan
Page 1 of 2 .
SHGC: 0.40
Window 16: Metal Frame:Double Pane with Low-E:
4
0.670
3
SHGC: 0.40
Window 17: Metal Frame:Double Pane with low-E:
15
0.670
10
SHGC: 0.40
Window 18: Metal Frame:Double Pane with Low-E:
15
0.670
10
SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
1023 30.0
0.0
36
Ceiling 2: Cathedral Ceiling (no attic):
39 19.0
0.0
2
Floor 1: Slab-On-Grade:Unheated:
144
0.0
150
Insulation depth: 0.0'
Floor 2: All -Wood Joist/Truss:Over Outside Air:
86 13.0
0.0
6
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 13 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requireme in the REScheck Inspection Checklist.
STY1�c-fZA� Zo 7
Name - Title Signature Date
Project Notes:
All U-Factors and SHGC are at entered at higher than actual amounts.
Actual amounts are lower, but are entered higher to account for
differences in ratings per material.
1714 Plan Page 2 of 2