Loading...
HomeMy WebLinkAboutRES2007-01233, 07-1234o�'1-ia�3i( Camp) r R 752 113 MOR "'J" I WF0893343 / 001 City of College Station PAGE 1 ti REQ. DATE: 04/27/07 04/27/07 14:39:48 LOCATION: 2907 MCLAREN DR LOC ID: 208570 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07 ******************************************************************************** JOB ORDER RESULT COMVIEN.CS (7/27/2007)1 Gina Southerland - Re: Calling for C.O. @ 2907 McLaren Dr. Page„1 From: Terry Boriskie To: Amber Carter; banderson@stylecraft-builders.com; Benjamin McCarty; Ch... Date: 7/27/2007 3:25 PM Subject: Re: Calling for C.O. @ 2907 McLaren Dr. Stylecraft Builders has been notified. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Mitchell Carson 7/27/2007 1:43 pm >>> Sewer box needs to be raised Mitch >>> Amber Carter 7/26/2007 1:14 PM >>> by #07-1233 PREPARED 7/26/07, 12:04:17 INSPECTION TICKET PAGE 17 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/26/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 2907 MCLAREN DR SUBDIV: SOUTHERN TRACE PH 2 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 579530-0207-0080 APPL NUMBER: 07-00001233 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---------------------------------------------------------------------------------------'--------- B115 01 5/31/07 RH BLDG, FRAMING TIME: 17:00 5/31/07 AE May 31, 2007 11:27:23 AM kwolfe. 05/31/2007 03:51 PM RH PDA Add osb on corner of wall by front and back doors. Draft stop false cavity by upstairs bathroom. B130 01 6/01/07 RH BLDG, INSULATION TIME: 17:00 6/01/07 AP June 1, 2007 3:34:54 PM glsouth. B132 01 6/05/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00 6/05 AP June 4, 2007 4:52:24 PM acarter. B125 01 7/26/0 I BLDG, FINAL TIME: 17:00 July 26, 2007 11:11:14 AM malford. -------------------------------------- COMMENTS AND NOTES -------------------------1------------- 0 Date: 7/26/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1233 Address: 2907 MCLAREN DR Type Inspection Type Code Description siatus Inspection Result Comments B115 BLDG, FRAMING IC 05/31/2007 03:51 PM RH PDA B115 BLDG, FRAMING IC Add osb on corner of wall by front and back doors. Draft B115 BLDG, FRAMING IC stop false cavity by upstairs bathroom. Ell ELEC, ROUGH IN IC 05/24/2007 03:42 PM RH PDA E110 ELEC, ROUGH IN IC S/d need min. 3ft from a/c vents. E150 ELEC, FINAL IC 07/17/2007 04:10 PM RH PDA E150 ELEC, FINAL IC Need ground wire on meter can. Install bathroom exhaust E150 ELEC, FINAL IC fan in bathroom downstairs by dining room. Need proper E150 ELEC, FINAL IC height at meter. Page 1 SHEET INDEX COVER SHEET G-1 GENERAL NOTES G-2 SITE PLAN C-1 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 DETAILS S-3 BRACING PLAN S-4 FRAMING PLAN S-5 ROOF FRAMING PLAN S-6 DECKING LAYOUT S-7 ELEVATIONS S-8 FRAMING DETAILS S-9 ELECTRICAL PLAN E-1 FLOOR PLAN A-1 FLOORING PLAN A-2 CABINET LAYOUT A-3 AREA FMSHING NOTES SUMMARY JY111R [1 1 loptional Appliance Package w w V,, � - 00Nww cltn�M —Ww More Home, Less Money x Qom ¢¢ oa,^ i sa —PORCH CF/]ZU�Ooofi '°'g V-w LOCATION KITCHEN DINING BEDROOM BEDROOM SUBDIV. ST WU 3j'-011'-i 10'88 �41'd' . © 17� TH'-i UT ,:,-0� 11'-�' — — — — — — — i PHASE 02 POYJDE TUG E © I BLOCK 07 BATH G'S�gx 5-y. � 0 o -moo- I I 0 E LOW I n14 eAni � B. I I a I LIVING BEDROOM 1 1 N e-0 I O r 15'-9'8 •1T4' I F,raR 13'.1' x 17-1' I �' N ON PORCH BEDROOM 4 0 OO _ 13'-10' x 11'S'---------------------J r 1 n �/ BUILDING ENVELOPE e� 37 P 31'J z� z COMMENTS V � as � ZH° o o N a U. 1 ST FLOOR PLAN PREVIEW 2ND FLOOR PLAN PREVIEW a SCALE:3P32-=1'-0" SCALE:3/32"=1'-0" (n o NOTICE THIS SET OF DRAWINGS FOR A HOME IS THE COPYRIGHTED PROPERTY OF SMECRAFT BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL OR ANY PORTION OF THE LICENSED PLANS IS GRANTED, EITHER EXPRESSLY OR IMPLIED. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THE DRAWING ARE OWNED BY AND THE PROPERTY OF THE DESIGNERS AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THE e SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE Q USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER Q z WITHOUT THE WRITTEN PERMISSION OF THE C DESIGNERS. W W W 4 MI UIn.p =i 00 U€ a. <� oo ' vE Sg SHEET: BFRONT ELEVATION G- I SCALE:3/32"=1'-0" COVER SHEET PLAN APPROVAL APPROVED INITIALS DATE ADMINISTRATOR / SUPERINTENDENT / CUSTOMER / AREA GENERAL NOTES SUMMARY G-2 GENERAL NOTES S-3 DETAILS S-7 DECKING PLAN A-1 FLOOR PLAN 1. NO GENERAL NOTES AT THIS TIME 1. NO GENERAL NOTES AT THIS TIME 2' 1. NO GENERAL NOTES AT THIS TIME 2. 1. NO GENERAL NOTES AT THIS TIME 2. LT, v] nr-t-M;^ V] w00 w ow UU � Qov Q O 00<¢aLL Op�WOwv�Inc ww0W�¢¢ �zN CaE">pHE�a Uo�oo�0. .� QUaz LOCATION SUBDIV. ST PHASE 02 BLOCK 07 LOT 08 C-1 SITE PLAN S-4 BRACING PLAN S-8 ELEVATIONS A-2 FLOORING PLAN 1. NO GENERAL NOTES AT THIS TIME 2. 1. NO GENERAL NOTES AT THIS TIME 2. 1. NO GENERAL NOTES AT THIS TIME 1. NO GENERAL NOTES AT THIS TIME 2. 2. r� N O - . p O� Li a C/� w F W O S-1 FOUNDATION PLAN NO GENERAL NOTES AT THIS TIME S-5 FRAMING PLAN 11. NO GENERAL S-9 FRAMING DETAILS A-3 CABINET LAYOUT � r I Qa 2. NOTES AT THIS TIME 1. NO GENERAL NOTES AT THIS TIME 1. NO GENERAL NOTES AT THIS TIME 2. 2. a\ U f S-2 DIMENSION PLAN S-6 ROOF FRAMING PLAN E-1 ELECTRICAL PLAN 1. NO GENERAL NOTES AT THIS TIME 2. 1. NO GENERAL NOTES AT THIS TIME 2. 1. NO GENERAL NOTES AT THIS TIME 2. F...� �E c � QO� L) �s W W VI r U a° �F > �g 9• • SHEET: G-2 GENERAI.NOTES r23t1Q3 I coc �o` -- 4C) .1 I Oy D1 01.1 C0 C4t') \\\ rr1'���n z al /� N O . -n w'uwC- 1J1 rLVVictll. YJJ Jr VJ n CREATED : 2907 MCLAREN : ST07021 r � [ p 2ND FLOOR AC 775 SF TAL CORRECTED PLAN# S-1747-B x � � > COVAC ERED PORCH 93 SF 1728 F 9 p C y STORAGE 41 SF FINAL STYLECRAFT BUILDERS, INC. ©2007 O OTAL FRAMED 1862 SF a i 4090 ST. HWY. 6 SOUTH COLLEGE STATION, TEXAS 77845 (979) 690-1222 O O OTAL SLAB 1087 SF O I4bA.11 AILIUNIISRCSPRWO. PIiPROOUCIION OP1tYS6 W(UI.PllIJ t� �-3 Z PFR TMF.TF.R 1 d(1 7' BUILDING PERMIT CITY OF�COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001233 Date 4/26/07 Application pin number . . . 885330 Property Address . . . . . . 2907 MCLAREN DR Property ID: 579530-0207-0080 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SOUTHERN TRACE PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 102643 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1728.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 497826 Permit Fee . . . . 469.00 Plan Check Fee .00 Issue Date . . 4/26/07 Valuation . . . . 102643 Expiration Date . . 10/23/07 Qty Unit Charge Per Extension BASE FEE 460.00 3.00 3.0000 THOU BLDG, VAL 100001-500000 9.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) --------------------------------------------- ---- BUILDING DEPT REPRE IVE: APPLICANT: BUILDING PERMIT CITY OF,COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001233 Date 4/26/07 Application pin number . . . 885330 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct BUILDING DEPT RE ESE IVE: APPLICANT: i BUILDING PERMIT CI'T'Y OF, COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00001233 Date 4/26/07 Application pin number . . . 885330 ---------------------------------------------------------------------------- Special Notes and Comments insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due - --------------- ----- ------------------------- ----- -- ----- - --------- BUILDING DEPT REP E IVE: APPLICANT: BUILDING PERMIT CITY OF -COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . ----------------- ---------- Permit Fee Total 469.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1219.00 Page 4 07-00001233 Date 4/26/07 885330 -------------------- 469.00 ---------- .00 .00 .00 .00 .00 750.00 .00 .00 1219.00 .00 .00 ------------------------------------------------ ----- - -- --- -�------- BUILDING DEPT REPRE TIVE: f�,) APPLICANT: TEMPORARY POLE PERMIT CITY OF• COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00001234 966340 2907 MCLAREN DR 579530-0207-0080 Date 4/26/07 TEMP POLE SOUTHERN TRACE PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 497834 Permit Fee . . . . 20.00 Issue Date . . . . 4/26/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT RE ENTATIVE: APPLICANT: ( )S� APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning& Development Services WWW CSTX.GOV ForOfficeUse Only DATE: 4_a� rV rrRCC REG APPLICATION # t.233 TEMP POLE # ) -a5,+ ADDRESS/LOCATION: � 9y-7 M(LA2C/J LOT v/" BLOCK 7 SUBDIVISION SOUTHERN TRACE SEC/PH 2 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing HVAC: To Be Determined GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION` MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing Less Slab STRUCTURE USE: Single Family Residence WALL BRACING METHOD: PRESCRIPTIVE APA PORTAL FRAME W/ CSPS ❑ ENGINEERED �X HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A TEXAS ACCESSIBILITY STANDARD (TAS) PROJI CT REGISTRATION# EABPRJ N/A VALUATION: $ 1-1*627,64Y Less Slab i � TOTAL AREA: 1862 HEATED AREA: 1728 (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM FK SEWER TAP: WATER TAP: OTHER TAP: © TEMP POLE GARAGE TYPE: 4" SIZE %11 SIZE DILL SINGLE El ATTACHED E] NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: 4 4.5 Sheet Rock Siding and/or Masonry Slab on Grade ROOF TYPE: Composition DOUBLE a TRIPLE DF D CARPORT SIGNATURE OF APPLICANT: L. For St lecraft *If proposed work involves new commercial constrLfction acade i provements/renovations to an existing commercial property, building elevations are required. � Official Use Only ments: YE or NO % Plans Examiner Zoning Official 5s "Ls — F_hytoeaj 32o.4p'l Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating o 10 /o R13 R30 R19 / .65 / R6 13 / PLAN REVIEW and-TWO--FAMIL-- OCCUPANCY,REQUIREMENTS-----". -- *-..'—' ..--:-:-.. CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D - I Z 33._ . . DATE: -3_--A_q-- d'7 -BUILDING ADDRESS: ^ IT7C-eW S L -Foundation Requirements- Minimum- Ci _ Foundation Standards = -=-(----_ =�- A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twen -four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist sizespacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter sizespacing, roof slope & purlin bracin if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ._...ONE and.TWO.FAMIL-Y.'OCGUPANCY-RE—QUIREMENT - r.j--6 :._.t CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. -,-Stairway Requirements OK K A. Stairway Details N 1: Maximum riser height 7.-3/4 inches. -_ 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere _J IV. Fireplace Requirements &MOK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW Eand..TWa5AWLY-OCCUPANCY REQUIREMENTS- CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure -reducing valve required when water pressure exceeds 80 psi _ ..- N --B-.--PlUhbihg access to bathtubs C. Means for thermal expansion provided when required D..Water heaters elevated 18" when -installed in the -garage -or- roonvdirectl-off- garage.- - VII. Mechanical Requirements NAJOW- A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for comer lots Subdivision Regulations — Ordinance 690 NAZCW Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE REScheck Software Version 4.0.1 Compliance Certificate Project Title: 1714 Plan Report Date: 03/16/07 Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\1714.00-Master.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 10% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: College Station, TX 77845 Stylecraft Builders, Inc. Stylecraft Builders, Inc. 4090 SH 6 South 4090 SH 6 South College Station, TX 77845 College Station, TX 77845 979-690-1222 x120 979-690-1222 x120 ewivagg@stylecraft-builders.com ewivagg@stylecraft-builders.com Maximum SHGC: 0.40 Your SHGC: 0.40 Wall 1: Wood Frame, 16" o.c.: 1293 13.0 0.0 92 Window 1: Metal Frame:Double Pane with Low-E: 3 0.670 2 SHGC: 0.40 Window 2: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 3: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 4: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 5: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 6: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Window 7: Metal Frame:Double Pane with Low-E: 9 0.670 6 SHGC: 0.40 Window 8: Metal Frame:Double Pane with Low-E: 9 0.670 6 SHGC: 0.40 Window 9: Metal Frame:Double Pane with Low-E: 18 0.670 12 SHGC: 0.40 Door 1: Solid: 20 0.500 10 Door 2: Glass: 18 0.440 8 SHGC: 0.40 Wall 2: Wood Frame, 16" o.c.: 1025 13.0 0.0 77 Window 10: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 11: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 12: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 13: Metal Frame:Double Pane with Low-E: 4 0.670 3 SHGC: 0.40 Window 14: Metal Frame:Double Pane with Low-E: 20 0.670 13 SHGC: 0.40 Window 15: Metal Frame:Double Pane with Low-E: 20 0.670 13 1714 Plan Page 1 of 2 SHGC: 0.40 Window 16: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 17: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Window 18: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Floor 1: Slab -On -Grade: Unheated: Insulation depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Outside Air: Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER 4 0.670 3 15 0.670 10 15 0.670 10 1023 30.0 0.0 36 39 19.0 0.0 2 144 0.0 150 86 13.0 0.0 6 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requireme liste 'n the REScheck Inspection Checklist. S Fyl-� 40Z-A alb /o Name -Title Signature C_� Date Project Notes: All U-Factors and SHGC are at entered at higher than actual amounts. Actual amounts are lower, but are entered higher to account for differences in ratings per material. 1714 Plan Page 2 of 2