HomeMy WebLinkAboutRES2007-01197a7fop
v
'v
Wit! k
V Vt
..
v
1
(11/19/2007) Kim Wolfe, ReuCAlling for CO for 217 Meir Lnv Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty;
Date: 11/16/2007 4:09 PM
Subject: Re: CAlling for CO for 217 Meir Ln
Contacted Contreras Const. at 775-3996
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
Chris Haver; Gina Southerland; Joe G...
>>> Mitchell Carson 11/14/2007 3:58 pm >>>
Sewer box is buried and needs to be brought to grade.I did place a green flag at the spot .... Mitch
>>> Amber Carter 11/14/07 12:45 PM >>>
by 07-1197
Any issues?
PREPARED
11/14/07, 12:00:15
INSPECTION TICKET
PAGE 4
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 11/14/07
ADDRESS
. : 217 MEIR LN
SUBDIV: EDELWEISS GARTENS PH
5
CONTRACTOR CONTRERAS CONSTRUCTION, INC PHONE (979) 775-3996
OWNER
EDELWEISS GARTEN
VENTURE PHONE :
PARCEL
244030-0504-0230
APPL NUMBER: 07-00001197 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
7/03/07 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
7/03/07 AP
Slab Ground Installed
07/03/2007 04:49 PM OC PDA
formboard survey .
B115 01
8/03/07 RH
BLDG, FRAMING TIME: 17:00
8/03/07 DP
August 1, 2007 8:23:22 AM glsouth.
08/03/2007 11:05 AM RH PDA
Meed proper apa nailing. Need min.27 '' of OSB in
corner
by window in breakfast area. Fireblock fireplace.
Add
anchors on interior wall bracing as per prints. Remove
-
pipes from side of garage and seal holes.
B115 02
8/07/07 OC
BLDG, FRAMING TIME: 17:00
8/08/07 AE
August 7, 2007 3:57:08 PM acarter.
08/08/2007 10:32 AM OC PDA
replacing window in nook to get 27 inch min. for
windbracing. OK TO BRICK .
B130 01
8/09/07 RH
BLDG, INSULATION TIME: 17:00
8/09/07 AP
August 8, 2007 3:25:05 PM acarter.
B110 01
8/24/07 RH
BLDG, FOUNDATION -GRADE BEAM TIME: 17:00
8/24/07 AP
August 24, 2007 11:36:22 AM kwolfe.
courtyard wall - partial inspection - see terry...:-)
okay to go out
B125 O1 11/14/0 B� BLDG, FINAL TIME: 17:00
November 14, 2007 9:50:16 AM acarter.
-------------------------------------- COMMENTS AND NOTES
Date: 11 /14/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1197
Address: 217 MEIR LN
Insp.
inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B100
BLDG, FOUNDATION -SLAB
IC
07/03/2007 04:49 PM OC PDA
B100
BLDG, FOUNDATION -SLAB
IC
formboard survey .
B115
BLDG, FRAMING
IC
08/03/2007 11:05 AM RH PDA
B115
BLDG, FRAMING
IC
Meed proper apa nailing. Need min.27" of OSB in corner
B115
BLDG, FRAMING
IC
by window in breakfast area. Fireblock fireplace. Add
B115
BLDG, FRAMING
IC
anchors on interior wall bracing as per prints. Remove
B115
BLDG, FRAMING
IC
pipes from side of garage and seal holes.
B115
BLDG, FRAMING
IC
08/08/2007 10:32 AM OC PDA
B115
BLDG, FRAMING
IC
replacing window in nook to get 27 inch min. for
B115
BLDG, FRAMING
IC
windbracing. OK TO BRICK.
E110
ELEC, ROUGH IN
IC
07/31/2007 10:26 AM RH PDA
E110
ELEC, ROUGH IN
IC
Need slab ground. Need to bond gastite as per
manufacture by
E110
ELEC, ROUGH IN
IC
framing.
E110
ELEC, ROUGH IN
IC
-Electrician called and said the slab ground is there just
E110
ELEC, ROUGH IN
IC
hard to see, if you follow copper from panel on outside of
E110
ELEC, ROUGH IN
IC
wall to by breakfast room you will find notched studs with
E110
ELEC, ROUGH IN
IC
slab ground in it.
E110
ELEC, ROUGH IN
IC
August 2, 2007 10:11:48 AM tboriskie.
E150
ELEC, FINAL
IC
11/05/2007 03:55 PM RH PDA
E150
ELEC, FINAL
IC
Jacuzzi tub not hot, could not test gfi.
M100
MECH, ROUGH IN
IC
07/27/2007 03:37 PM RH PDA
M100
MECH, ROUGH IN
IC
Make sure bathroom exhaust duct is complete d by
M100
MECH, ROUGH IN
IC
Make sure dryer duct terminates beyond roof deck
completely.
M110
MECH, FINAL
IC
08/08/2007 10:33 AM OC PDA
M110
MECH, FINAL
IC
wrong inspection .
M110
MECH, FINAL
IC
10/30/2007 02:59 PM RH PDA
M110
MECH, FINAL
IC
Need to completely insulate line set at condensor by
M110
MECH, FINAL
IC
building final.
Page 1
Date: 11 /14/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1197
Address: 217 MEIR LN
Type
Inspection Type Code
status
Inspection Result Comments
Description
P105
PLBG, TOP OUT
IC
08/02/2007 03:43 PM OC PDA
P105
PLBG, TOP OUT
IC
rerout pan & t.p. drain lines out of zero lot line
P105
PLBG, TOP OUT
IC
construction .
Page 2
G P, C O
SURVEY LEGEND
'fir
SUREaP a"M"P VER7rTAVE B3 w47ERMETER
—
o ~LW FENOE 04 WATER WALIC
—�/�-- AIDDO FENCE ti FW MmRwr
�— 84BBWkE MYCE ® ElES W Aff7FA
C)
DRAMIGE E45EMEN7 o PDHt71 Par
—ELEM� EAIMg TRANSFORMER
NTYf
: 7,AN
ORONwNS
CE DtXLPJO LW WaE
— — — — PLATTED BLw_D r LM 0 S712 AfWOME
25' ALLEY
RE57RCTMW BNM M LM ® SG-W Z4W
0 5/8- MN ROD FOLMO i ARM ROD SET m 7F[RWDW PMESTAL
(GH1FD N 41'41'27' E 60.001
N 41'39'35" E
(PLAT)
9.9
Survey Notes
1). The bewing bosie of this surrey la S 41'41'27' W as recorded In
Volume 5924. Page 94 of the B.C.O.R.
2). Drawing Seale Is 1•-30'
gel
3p\
eao
J
3). TerJmklan: Jasm Bopey, Fldd Crew. R. Rivera
.10
—
1�
4). Said lot d«s nol appear to be under the tOD year hood plain, oa
gl„
cV
identified by the Federal Emergeney Monogement Agency on Community
C
I
- Cq
�y
I 1�1�
S
I
I
Panel No. 48041CO200 C. Dated: July 2, 1992
4 Dante Coriamogno. Registered Professional Land Surveyor No. 15OZ
do hereby certify that the above survey is a true and accurate
0.ss FOUNDATION
representation of an actual on the ground survey made under my
sup —sloe and that there ore no en anachments or cnwiopt unless
LOT 22
;
FORM
1d
otherwise shown.
BLOCK 4
3
w R
m
LOT 24 I
BLOCK 4
LOT 25
BLOCK 4
OF
LOT 23
BLOCK 4
IcO a
I
I
.. a ......................
•• CARLOMAGNO
`t
1562..pv°
�'CES5��C.
7'JO Z
AE
—
�..
— —
Cariom <.y`
R estMnal
Land Surveyor, Number 1582 eS U ft1F'
— —
— —
a�
1
— —
— —
PLAT OF SURVEY
(CALLM S 41'41'27' W
w. Na.: TWENTY—THREE (23)
S 41'56'59" W
BLOCK No.: FOUR (4)
9.95
SUBMWON: EDELWEISS GARTENS, PHASE FIVE, 5824/94
MEIR LANE
s1REEr ADDREm- 217 MEIR LANE
(50' R.O.W.)
cfrT: COLLEGE STATION CouNim. BRAZOS
SURVEYED FOR: MAJESTIC HOMES
• THIS SURVEY WAS COMPLEIM IWf1101ff THE 804TR OF A TMIE CMUMEW-
Carlomagno Surveying, Inc.
2714 Pinfeather Rood, Bryon, Texas 77801
ifs nunx 0719t.DWO
Plot sots 07/02/07 of ltktg
PHONE: (971 75-2873 FAX: (979)775-4787
www.CarlomognoSurveying.conn
TEMPORARY POLE PERMIT'
CITY OF COLLEGE STATION
1101 ' TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001883 Date
6/22/07
Application pin number . . .
735398
Property Address . . . . . .
217 MEIR LN
Property ID:
244030-0504-0230
Application type description
TEMP POLE
Subdivision Name . . . . . .
EDELWEISS GARTENS PH 5
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
CONTRERAS CONSTRUCTION,
INC
311 CECILIA LOOP
1708 WILSON ST
COLLEGE STATION TX 778456310
BRYAN TX
77803
(979) 775-3996
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GS
Permit pin number . 509943
Permit Fee . . . . 20.00
Issue Date . . . . 6/22/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------------------------
BUILDING DEPT REPRESENTATIVE� p
APPLICANT:
WF0915008 / 001 City of College Station
PAGE 1
REQ. DATE: 06/08/07 06/08/07 16:39:27
LOCATION: 217 MEIR LN LOC ID: 199100
REQUESTOR: CONTRERAS CONSTRUCTION INC ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 06/08/07 SCHED COMPLETION: 06/08/07
********************************************************************************
JOB ORDER RESULT COMMENTS
15'-8 9/18'
N
N ` t
rn a
D O
a
D ' �nN
dcl
r �
o
m �
f E
oC) cu
Y �rn
z '
m
N 0
O >
i� ;u
O z
U)
1
ERO LOT LINE
88'-4 1 /2"
o
<�
rnc�g �
m l
20'-10 15/16"
N ! a
EX
ca
BACK
1
105.00 —
BUILDING PERMIT
CITY OF COLLEGE STATION '
1101 TEXAS AVENUE, COLLEGE,,9ZA1;ON, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number .
. . . . 07-00001197 Date 6/08/07
Application pin number . . . 381168
Property Address . .
. . . . 217 MEIR LN
Property ID:
244030-0504-0230
R #:
R116567
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . EDELWEISS GARTENS PH 5
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 140000
Owner
Contractor
------------------------ ------------------------
EDELWEISS GARTEN VENTURE CONTRERAS CONSTRUCTION, INC
311 CECILIA LOOP
1708 WILSON ST
COLLEGE STATION
TX 778456310 BRYAN TX 77803
(979) 775-3996
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK VENEER
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1751.00
INTERIOR WALL TYPE DRYWALL
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit pin number .
507574
Permit Fee . . . .
580.00 Plan Check Fee .00
Issue Date . . . .
6/08/07 Valuation . . . . 140000
Expiration Date . .
12/05/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
40.00 3.0000
THOU BLDG, VAL 100001-500000 120.00
----------------------------------------------------------------------------
Special Notes and Comments
Make sure to call for
Brick Wall Inspect'
�cl OF C E
-----------------------------------------------
BUILDING DEPT 7,ERRESEATATIVE
-- - �x-------------
: COD Station, TX 77842
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE -STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00001197
Application pin number . . . 381168
Page 2
Date 6/08/07
Special Notes and Comments
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
and Interior Anchors and Modified Breakfast Area per Plans
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATI
- - - - - - - - - - - - - - - - - - - - - W
-------------------- - - - - ---BUILDING DEPTRESE�TA
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION °
1101 TEXAS AVENUE, COLLEGE•STATTON, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00001197
Application pin number . . . 381168
Page 3
Date 6/08/07
Special Notes and Comments
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
-------------------------------------------------- ------ ----- -----------
13UILDING DEPT FE.VRESEN T VE:
APPLICANT: n�,.
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE•STATTON, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00001197 Date
6/08/07
Application pin number . . . 381168
----------------------------------------------------------------------------
Special Notes and Comments
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Exterior walls located on property line shall have a one
hour fire resistance rating without openings. Overhangs
extending over the property line shall have a one hour fire
resistant construction on the under side, perforated
venting allowed,and shall extend a maximum of 18". Slab
edge shall be built on property line.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 580.00 580.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1330.00 1330.00 .00
.00
----------A-
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION " WWW.CSTX.GOV
Planning car Development Services
ADDRESS/LOCATION: 0217 YvIPtr Vrlvf
Fcv Office Use Only
DATE: - Z R C REG
APPLICATION # V_� — 11 Gl''')
TEMP POLE #
LOT �j BLOCK SUBDIVISION E4_L ) 12SS QrkAU SEC/PH_�—
BUSINESS/OWNER NAME: �'frprat.s �o�ts� L�zC_ PHONE:
CONTRACTOR/HOMEOWNER: (LZr c's a-"hW'r_'.S PHONE: 979 - Yia -adz y
CONTRACTOR ADDRESS: l70F5 OI (So,n ,Sf _ &l,(o-mot TX 77kl)
ELECTRICIAN: �r2sirz ce_ Ele-cirtC PLUMBER: &.S5 PIUM4)�'g
HVAC: Ah COnCOP± �V1 Cf_5 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: 3I�r_ Mj!j Poo IkIne—
PROPOSED USE: 14-S, 1emCe-
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 1 `0, DDo � TOTAL AREA: `') 43 HEATED AREA: 1-7S I
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 41
11
SIZE r
rWATER TAP: .314
SIZE
❑ OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE 71
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE ET TRIPLE
DETACHED F_� CARP05
SIGNATURE OF APPLICANT: ('ol^h'ej4S UA4 .Lnc, toti, C
'If proposed work involves new commercial construction or facad6 im
commercial property, building elevations are required.
17 Official Use Only
�/o Plans Examiner
% z-_Q+
celo lc6ek S i Q b
a ,', A
ents/renovations to an existing
NC
Zoning Official Fire n shall
Fti 6VA_ c,,/.�4
Co nts:
r r NO de,,f4tjdt,oAI J-�•t.S�t7ryA
r. Engrgy� Code Compliance Information
.J . r
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
M
I
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# Off_ 119,1
DATE:
BUILDING ADDRESS: ,Z
e4fZ -Al
I. Foundation Requirements-. Minimum City Foundation Stan ards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
O
il. Framing:
Floor, Wall, Ceiling and Roof Requirements
KAJOW
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
WAOK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
NA/
NA/
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace re uires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/OK
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
�- 23 -0 7
DATE
Apr 24 07 08:59a Matrix Technologies
979-846-7005 p.1
J
315 ° Rrbnn
24"6.G.
V
FRc�
�° CopC
QLoGk
B abtcK �rEs
v Q ALL. B IeGK
l..
s #S ROS
top
»ro
No,ri ;
3,(r
g�1-6v�E c. (J rh r
C AtLos tbir. COWr7bwcrt/o1�