Loading...
HomeMy WebLinkAboutRES2007-01197a7fop v 'v Wit! k V Vt .. v 1 (11/19/2007) Kim Wolfe, ReuCAlling for CO for 217 Meir Lnv Page 1 From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Date: 11/16/2007 4:09 PM Subject: Re: CAlling for CO for 217 Meir Ln Contacted Contreras Const. at 775-3996 Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 Chris Haver; Gina Southerland; Joe G... >>> Mitchell Carson 11/14/2007 3:58 pm >>> Sewer box is buried and needs to be brought to grade.I did place a green flag at the spot .... Mitch >>> Amber Carter 11/14/07 12:45 PM >>> by 07-1197 Any issues? PREPARED 11/14/07, 12:00:15 INSPECTION TICKET PAGE 4 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 11/14/07 ADDRESS . : 217 MEIR LN SUBDIV: EDELWEISS GARTENS PH 5 CONTRACTOR CONTRERAS CONSTRUCTION, INC PHONE (979) 775-3996 OWNER EDELWEISS GARTEN VENTURE PHONE : PARCEL 244030-0504-0230 APPL NUMBER: 07-00001197 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/03/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 7/03/07 AP Slab Ground Installed 07/03/2007 04:49 PM OC PDA formboard survey . B115 01 8/03/07 RH BLDG, FRAMING TIME: 17:00 8/03/07 DP August 1, 2007 8:23:22 AM glsouth. 08/03/2007 11:05 AM RH PDA Meed proper apa nailing. Need min.27 '' of OSB in corner by window in breakfast area. Fireblock fireplace. Add anchors on interior wall bracing as per prints. Remove - pipes from side of garage and seal holes. B115 02 8/07/07 OC BLDG, FRAMING TIME: 17:00 8/08/07 AE August 7, 2007 3:57:08 PM acarter. 08/08/2007 10:32 AM OC PDA replacing window in nook to get 27 inch min. for windbracing. OK TO BRICK . B130 01 8/09/07 RH BLDG, INSULATION TIME: 17:00 8/09/07 AP August 8, 2007 3:25:05 PM acarter. B110 01 8/24/07 RH BLDG, FOUNDATION -GRADE BEAM TIME: 17:00 8/24/07 AP August 24, 2007 11:36:22 AM kwolfe. courtyard wall - partial inspection - see terry...:-) okay to go out B125 O1 11/14/0 B� BLDG, FINAL TIME: 17:00 November 14, 2007 9:50:16 AM acarter. -------------------------------------- COMMENTS AND NOTES Date: 11 /14/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1197 Address: 217 MEIR LN Insp. inspection Type Code Description p. status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B100 BLDG, FOUNDATION -SLAB IC 07/03/2007 04:49 PM OC PDA B100 BLDG, FOUNDATION -SLAB IC formboard survey . B115 BLDG, FRAMING IC 08/03/2007 11:05 AM RH PDA B115 BLDG, FRAMING IC Meed proper apa nailing. Need min.27" of OSB in corner B115 BLDG, FRAMING IC by window in breakfast area. Fireblock fireplace. Add B115 BLDG, FRAMING IC anchors on interior wall bracing as per prints. Remove B115 BLDG, FRAMING IC pipes from side of garage and seal holes. B115 BLDG, FRAMING IC 08/08/2007 10:32 AM OC PDA B115 BLDG, FRAMING IC replacing window in nook to get 27 inch min. for B115 BLDG, FRAMING IC windbracing. OK TO BRICK. E110 ELEC, ROUGH IN IC 07/31/2007 10:26 AM RH PDA E110 ELEC, ROUGH IN IC Need slab ground. Need to bond gastite as per manufacture by E110 ELEC, ROUGH IN IC framing. E110 ELEC, ROUGH IN IC -Electrician called and said the slab ground is there just E110 ELEC, ROUGH IN IC hard to see, if you follow copper from panel on outside of E110 ELEC, ROUGH IN IC wall to by breakfast room you will find notched studs with E110 ELEC, ROUGH IN IC slab ground in it. E110 ELEC, ROUGH IN IC August 2, 2007 10:11:48 AM tboriskie. E150 ELEC, FINAL IC 11/05/2007 03:55 PM RH PDA E150 ELEC, FINAL IC Jacuzzi tub not hot, could not test gfi. M100 MECH, ROUGH IN IC 07/27/2007 03:37 PM RH PDA M100 MECH, ROUGH IN IC Make sure bathroom exhaust duct is complete d by M100 MECH, ROUGH IN IC Make sure dryer duct terminates beyond roof deck completely. M110 MECH, FINAL IC 08/08/2007 10:33 AM OC PDA M110 MECH, FINAL IC wrong inspection . M110 MECH, FINAL IC 10/30/2007 02:59 PM RH PDA M110 MECH, FINAL IC Need to completely insulate line set at condensor by M110 MECH, FINAL IC building final. Page 1 Date: 11 /14/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1197 Address: 217 MEIR LN Type Inspection Type Code status Inspection Result Comments Description P105 PLBG, TOP OUT IC 08/02/2007 03:43 PM OC PDA P105 PLBG, TOP OUT IC rerout pan & t.p. drain lines out of zero lot line P105 PLBG, TOP OUT IC construction . Page 2 G P, C O SURVEY LEGEND 'fir SUREaP a"M"P VER7rTAVE B3 w47ERMETER — o ~LW FENOE 04 WATER WALIC —�/�-- AIDDO FENCE ti FW MmRwr �— 84BBWkE MYCE ® ElES W Aff7FA C) DRAMIGE E45EMEN7 o PDHt71 Par —ELEM� EAIMg TRANSFORMER NTYf : 7,AN ORONwNS CE DtXLPJO LW WaE — — — — PLATTED BLw_D r LM 0 S712 AfWOME 25' ALLEY RE57RCTMW BNM M LM ® SG-W Z4W 0 5/8- MN ROD FOLMO i ARM ROD SET m 7F[RWDW PMESTAL (GH1FD N 41'41'27' E 60.001 N 41'39'35" E (PLAT) 9.9 Survey Notes 1). The bewing bosie of this surrey la S 41'41'27' W as recorded In Volume 5924. Page 94 of the B.C.O.R. 2). Drawing Seale Is 1•-30' gel 3p\ eao J 3). TerJmklan: Jasm Bopey, Fldd Crew. R. Rivera .10 — 1� 4). Said lot d«s nol appear to be under the tOD year hood plain, oa gl„ cV identified by the Federal Emergeney Monogement Agency on Community C I - Cq �y I 1�1� S I I Panel No. 48041CO200 C. Dated: July 2, 1992 4 Dante Coriamogno. Registered Professional Land Surveyor No. 15OZ do hereby certify that the above survey is a true and accurate 0.ss FOUNDATION representation of an actual on the ground survey made under my sup —sloe and that there ore no en anachments or cnwiopt unless LOT 22 ; FORM 1d otherwise shown. BLOCK 4 3 w R m LOT 24 I BLOCK 4 LOT 25 BLOCK 4 OF LOT 23 BLOCK 4 IcO a I I .. a ...................... •• CARLOMAGNO `t 1562..pv° �'CES5��C. 7'JO Z AE — �.. — — Cariom <.y` R estMnal Land Surveyor, Number 1582 eS U ft1F' — — — — a� 1 — — — — PLAT OF SURVEY (CALLM S 41'41'27' W w. Na.: TWENTY—THREE (23) S 41'56'59" W BLOCK No.: FOUR (4) 9.95 SUBMWON: EDELWEISS GARTENS, PHASE FIVE, 5824/94 MEIR LANE s1REEr ADDREm- 217 MEIR LANE (50' R.O.W.) cfrT: COLLEGE STATION CouNim. BRAZOS SURVEYED FOR: MAJESTIC HOMES • THIS SURVEY WAS COMPLEIM IWf1101ff THE 804TR OF A TMIE CMUMEW- Carlomagno Surveying, Inc. 2714 Pinfeather Rood, Bryon, Texas 77801 ifs nunx 0719t.DWO Plot sots 07/02/07 of ltktg PHONE: (971 75-2873 FAX: (979)775-4787 www.CarlomognoSurveying.conn TEMPORARY POLE PERMIT' CITY OF COLLEGE STATION 1101 ' TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001883 Date 6/22/07 Application pin number . . . 735398 Property Address . . . . . . 217 MEIR LN Property ID: 244030-0504-0230 Application type description TEMP POLE Subdivision Name . . . . . . EDELWEISS GARTENS PH 5 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ CONTRERAS CONSTRUCTION, INC 311 CECILIA LOOP 1708 WILSON ST COLLEGE STATION TX 778456310 BRYAN TX 77803 (979) 775-3996 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 509943 Permit Fee . . . . 20.00 Issue Date . . . . 6/22/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ------------------------------ ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------- BUILDING DEPT REPRESENTATIVE� p APPLICANT: WF0915008 / 001 City of College Station PAGE 1 REQ. DATE: 06/08/07 06/08/07 16:39:27 LOCATION: 217 MEIR LN LOC ID: 199100 REQUESTOR: CONTRERAS CONSTRUCTION INC ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/08/07 SCHED COMPLETION: 06/08/07 ******************************************************************************** JOB ORDER RESULT COMMENTS 15'-8 9/18' N N ` t rn a D O a D ' �nN dcl r � o m � f E oC) cu Y �rn z ' m N 0 O > i� ;u O z U) 1 ERO LOT LINE 88'-4 1 /2" o <� rnc�g � m l 20'-10 15/16" N ! a EX ca BACK 1 105.00 — BUILDING PERMIT CITY OF COLLEGE STATION ' 1101 TEXAS AVENUE, COLLEGE,,9ZA1;ON, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00001197 Date 6/08/07 Application pin number . . . 381168 Property Address . . . . . . 217 MEIR LN Property ID: 244030-0504-0230 R #: R116567 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 5 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 140000 Owner Contractor ------------------------ ------------------------ EDELWEISS GARTEN VENTURE CONTRERAS CONSTRUCTION, INC 311 CECILIA LOOP 1708 WILSON ST COLLEGE STATION TX 778456310 BRYAN TX 77803 (979) 775-3996 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK VENEER IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1751.00 INTERIOR WALL TYPE DRYWALL NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 507574 Permit Fee . . . . 580.00 Plan Check Fee .00 Issue Date . . . . 6/08/07 Valuation . . . . 140000 Expiration Date . . 12/05/07 Qty Unit Charge Per Extension BASE FEE 460.00 40.00 3.0000 THOU BLDG, VAL 100001-500000 120.00 ---------------------------------------------------------------------------- Special Notes and Comments Make sure to call for Brick Wall Inspect' �cl OF C E ----------------------------------------------- BUILDING DEPT 7,ERRESEATATIVE -- - �x------------- : COD Station, TX 77842 APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE -STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00001197 Application pin number . . . 381168 Page 2 Date 6/08/07 Special Notes and Comments Narrow Wall Bracing Fully Sheathed with APA Garage Framing and Interior Anchors and Modified Breakfast Area per Plans ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATI - - - - - - - - - - - - - - - - - - - - - W -------------------- - - - - ---BUILDING DEPTRESE�TA APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION ° 1101 TEXAS AVENUE, COLLEGE•STATTON, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00001197 Application pin number . . . 381168 Page 3 Date 6/08/07 Special Notes and Comments IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES -------------------------------------------------- ------ ----- ----------- 13UILDING DEPT FE.VRESEN T VE: APPLICANT: n�,. BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE•STATTON, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00001197 Date 6/08/07 Application pin number . . . 381168 ---------------------------------------------------------------------------- Special Notes and Comments THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Exterior walls located on property line shall have a one hour fire resistance rating without openings. Overhangs extending over the property line shall have a one hour fire resistant construction on the under side, perforated venting allowed,and shall extend a maximum of 18". Slab edge shall be built on property line. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 580.00 580.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1330.00 1330.00 .00 .00 ----------A- APPLICANT: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION " WWW.CSTX.GOV Planning car Development Services ADDRESS/LOCATION: 0217 YvIPtr Vrlvf Fcv Office Use Only DATE: - Z R C REG APPLICATION # V_� — 11 Gl''') TEMP POLE # LOT �j BLOCK SUBDIVISION E4_L ) 12SS QrkAU SEC/PH_�— BUSINESS/OWNER NAME: �'frprat.s �o�ts� L�zC_ PHONE: CONTRACTOR/HOMEOWNER: (LZr c's a-"hW'r_'.S PHONE: 979 - Yia -adz y CONTRACTOR ADDRESS: l70F5 OI (So,n ,Sf _ &l,(o-mot TX 77kl) ELECTRICIAN: �r2sirz ce_ Ele-cirtC PLUMBER: &.S5 PIUM4)�'g HVAC: Ah COnCOP± �V1 Cf_5 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: 3I�r_ Mj!j Poo IkIne— PROPOSED USE: 14-S, 1emCe- HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 1 `0, DDo � TOTAL AREA: `') 43 HEATED AREA: 1-7S I (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: 41 11 SIZE r rWATER TAP: .314 SIZE ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE 71 ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE ET TRIPLE DETACHED F_� CARP05 SIGNATURE OF APPLICANT: ('ol^h'ej4S UA4 .Lnc, toti, C 'If proposed work involves new commercial construction or facad6 im commercial property, building elevations are required. 17 Official Use Only �/o Plans Examiner % z-_Q+ celo lc6ek S i Q b a ,', A ents/renovations to an existing NC Zoning Official Fire n shall Fti 6VA_ c,,/.�4 Co nts: r r NO de,,f4tjdt,oAI J-�•t.S�t7ryA r. Engrgy� Code Compliance Information .J . r % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating M I PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# Off_ 119,1 DATE: BUILDING ADDRESS: ,Z e4fZ -Al I. Foundation Requirements-. Minimum City Foundation Stan ards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated O il. Framing: Floor, Wall, Ceiling and Roof Requirements KAJOW A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck WAOK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements NA/ NA/ A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace re uires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/OK Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER �- 23 -0 7 DATE Apr 24 07 08:59a Matrix Technologies 979-846-7005 p.1 J 315 ° Rrbnn 24"6.G. V FRc� �° CopC QLoGk B abtcK �rEs v Q ALL. B IeGK l.. s #S ROS top »ro No,ri ; 3,(r g�1-6v�E c. (J rh r C AtLos tbir. COWr7bwcrt/o1�