PREPARED 11/14/07, 12:00:15 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/14/07
------------------------------------------------------------------------------------------------
ADDRESS . : 219 MEIR LN SUBDIV: EDELWEISS GARTENS PH 5
CONTRACTOR CONTRERAS CONSTRUCTION, INC PHONE (979) 775-3996
OWNER EDELWEISS GARTEN VENTURE PHONE
PARCEL 244030-0504-0240
APPL NUMBER: 07-00001196 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 O1 7/05/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
7/05/07 AP July 3, 2007 2:41:12 PM glsouth.
thursady morning
Form Survey Submitted
Slab Ground Installed
B115 01 8/02/07 OC BLDG, FRAMING TIME: 17:00
8/02/07 DP August 1, 2007 8:24:09 AM glsouth.
Sheetrock Fireplace Chase, Firestopping
Joist Hangers Needed
Garage APA Portal Framing Incorrect
08/02/2007 05:12 PM OC PDA
need wind bracing per plan.remove plumbing from zero lot
line construction . hangers in foyer needed
B115.02 8/07/07 OC BLDG, FRAMING TIME: 17:00
8/08/07 AE August 7, 2007 3:57:34 PM acarter.
08/08/2007 10:32 AM OC PDA
replacing window in nook to get 27 inch min. for
windbracing. OK TO BRICK .
B130 01 8/09/07 RH BLDG, INSULATION TIME: 17:00
07 AP August 8, 2007 3:25:29 PM acarter.
B125 0�/07BI BLDG, FINAL TIME: 17:00
/ e November 14, 2007 9:51:21 AM acarter.
---------------------'-----`-------------- COMMENTS AND NOTES ---------------------- ---------------
CC,
Date: 11 /14/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1196
Address: 219 MEIR LN
Ty Pe
Inspection Type Code
Description
siius
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Form Survey Submitted
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
Sheetrock Fireplace Chase, Firestopping
B115
BLDG, FRAMING
IC
Joist Hangers Needed
B115
BLDG, FRAMING
IC
Garage APA Portal Framing Incorrect
B115
BLDG, FRAMING
IC
08/02/2007 05:12 PM OC PDA
B115
BLDG, FRAMING
IC
need wind bracing per plan.remove plumbing from zero lot
B115
BLDG, FRAMING
IC
line construction . hangers in foyer needed
B115
BLDG, FRAMING
IC
08/08/2007 10:32 AM OC PDA
6115
BLDG, FRAMING
IC
replacing window in nook to get 27 inch min. for
B115
BLDG, FRAMING
IC
windbracing. OK TO BRICK.
Ell
ELEC, ROUGH IN
IC
07/31/2007 10:25 AM RH PDA
Ell
ELEC, ROUGH IN
IC
Need to bond gastite as per manufacture by framing.
E150
ELEC, FINAL
IC
11/05/2007 03:54 PM RH PDA
E150
ELEC, FINAL
IC
Need covers on all counter top plugs.
M100
MECH, ROUGH IN
IC
07/27/2007 03:35 PM RH PDA
M100
MECH, ROUGH IN
IC
Complete exhaust fan duct in bathrooms by framing.
M110
MECH, FINAL
IC
08/08/2007 10:33 AM OC PDA
M110
MECH, FINAL
IC
wrong inspection .
M110
MECH, FINAL
IC
10/30/2007 02:24 PM RH PDA
M110
MECH, FINAL
IC
Completely insulate line set at condensor by building final.
P105
PLBG, TOP OUT
IC
08/02/2007 03:43 PM OC PDA
P105
PLBG, TOP OUT
IC
rerout pan & t.p. drain lines out of zero lot line
P105
PLBG, TOP OUT
IC
construction .
Page 1
WF0915010 / 001 City of,College Station PAGE 1
Ir
REQ. DATE: 06/08/07 06/08/07 16:40:14
LOCATION: 219 MEIR LN LOC ID: 199102
REQUESTOR: CONTRERAS CONSTRUCTION INC ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 06/08/07 SCHED COMPLETION: 06/08/07
********************************************************************************
JOB ORDER RESULT COMMENTS
GAA4O
2. O
25' ALLEY
(PLAT)
n
N
�U')
I i Flo
3
LOT 22 LOT 23 13
BLOCK 4 BLOCK 4 �?
I �o
Z'
— — 7
IlL
File rlanr: 07190.DW0
Plot daEC o7/02/D7 at ,4:E1
(CALLED N 41'41'27' E 60,00)
N 41'44'36" E
I-W
1
RL
O
I0-
'W1
to 8
I
I-09,
I' FOUNDATION
FORM
w
is
LOT 24
c�v
BLOCK 4
r--
!
I101
m IS4r41'27"W 60.On
S 41'37'57" W
—60.14` —'
MEIR LANE
(50' R.O.W.)
SURVEY LEGEND
•ice SUI:i/LCT FRgpEA7y iAHE
L2EC7KI S
'�---if— %t)O IVV4 IYt7,ER WW
_ B4R8N7R£ fE)YLE F7 W MADAM
— ORAAAIG£ LASENpVT 4 POM POLE
— QECTRJG4L AY FAS 11 ,q
RILYAT- IfG1Y GSDNOVT �
"_— �__ —.• vwry EAs Avvr PRfX+ANE TAApf
-- IM VWARY /6Y MXr
` '_� — A1ES7RXWM BtA DW LeW SM
T
® 1/B L40W IPOO FOUht7 BROW RODSET 7ELE wave From7AL
Survey Notes:
J. The bearing bails Offthis h survey is 5 41'41'27"Woe rcaorded In
dune 5e24, Pegs 94 of the B.C.O.R.
2). Drawing Scab to 1".,W
3). Teanlelom JOson Batley, Field Crew: R. ll
4). Said lot dose not appear to be under the 100 year flood plain, us
identified by the Federal Emergent Management Agency on Community
Panel No. 49041CO200 C. Dated: IY 2, 1982
I, Dante Codomogno, Registered Professional Land Surveyor No. 1562,
111
do hereby cartify that the above survey Is true and aturate
representation of an Odudl an the ground survey made under my
supervision and that there are no encroachments or overlaps unless
LOT 25
otherwise shown.
BLOCK 4 W
OF, F
1562
Land Surveyor, Number 1562 " � U 11I
- - PLAT OF SURVEY
LOT No.: TWENTY—FOUR (24)
BLOCK No.: FOUR (4)
SUBDIVISION: EDELWEISS GARTENS, PHASE FIVE, 5824/94
STREET ADDRESS: 219 MEIR LANE
CRY: COLLEGE STATION COUNTY: BRAZOS
SURVEYEO FOR: MAJESTIC HOMES
• THIS SURVEY WAS COMPLETED WHMOUT THE BENERT OF A I ILE COIMTMEsr,
Carlomagno Surveying, Inc.
2714 Finfecther Road, Bryan, Texas 77801
PHONE: (979)775-2873 FAX' i9791775-A7Jt
D`7 - I19&
BUILDING PERMIT
`
CITY 09 C6±71,tEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE:
(979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
http://bpinspect.cstx.gov
Application Number
. . . . . 07-00001196
Date 6/08/07
Application pin number . . . 290624
Property Address
. . . . . . 219 MEIR LN
Property ID:
244030-0504-0240
R #:
R116568
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . . EDELWEISS GARTENS PH 5
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 140000
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
CONTRERAS CONSTRUCTION, INC
311 CECILIA LOOP
1708 WILSON ST
COLLEGE STATION
TX 778456310 BRYAN
TX 77803
(979) 775-3996
--- Structure Information
000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK VENEER
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1751.00
INTERIOR WALL TYPE
DRYWALL
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. KW
Permit pin number
. 507582
Permit Fee . . .
. 580.00 Plan Check Fee
.00
Issue Date . . .
. 6/08/07 Valuation . .
. . 140000
Expiration Date .
. 12/05/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
40.00 3.0000
THOU BLDG, VAL 100001-500000
120.00
----------------------------------------------------------------------------
Special Notes and
Comments
Make sure to call
in Inspections for Brick Wall.
-------- ---- --------
BUILDING DEPT R P ESEN TI E
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00001196 Date 6/08/07
Application pin number . . . 290624
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing Fully Sheathed with APA Garage Framing
and Interior Anchors and Bracing and Modified Breakfast
Windows.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
------------------------------------------------ ------ -------------------
BUILDING DEPT E RESE TAT V
APPLICANT:
BUILDING PERMIT
CITY Off'' COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00001196 Date 6/08/07
Application pin number . . . 290624
----------------------------------------------------------------------------
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP,
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
BUILDING DEPT ESE T E:
APPLICANT: .. ,.
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00001196 Date
6/08/07
Application pin number . . . 290624
----------------------------------------------------------------------------
Special Notes and Comments
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Exterior walls located on property line shall have a one
hour fire resistance rating without openings. Overhangs
extending over the property line shall have a one hour fire
resistant construction on the under side, perforated
venting allowed,and shall extend a maximum of 18". Slab
edge shall be built on property line.
----------------------------------------------------------------------------
Other Fees . . . . . . .. SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 580.00 580.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1330.00 1330.00 .00
.00
-----------------------------------------
BUILDING DEPT j 1&� , P�TA_ Ano-dy.
VAS
APPLICANT:
ELECTRICAL PERMIT
CITY OF COLLEGE STATION
1101
TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE:
(979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
http://bpinspect.cstx.gov
Page 2
Application
Number . . . . . 07-00001379
Date 6/08/07
Application
pin number . . . 199054
----------------------------------------------------------------------------
Fee summary
Charged Paid Credited
------------------------------
Due
----------
-----------------
Permit Fee
Total 43.74 .00
.00
43.74
Plan Check
Total .00 .00
.00
.00
Other Fee Total
750.00 750.00
.00
.00
Grand Total
793.74 750.00
.00
43.74
-
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning c3 Development Services
For OfficeUseOnly �
DATE: ()_ 1 _ 2 TRC V EG
APPLICATION #
TEMP POLE #
ADDRESS/LOCATION:
Jt rtve
LOT "1 BLOCK _ _V SUBDIVISION E0k] W l2SS `-d e AS SEC/PH_5
BUSINESS/OWNER NAME: l—oh�� List TLC- PHONE: 9-?9-7W-3,V/0
CONTRACTOR/HOMEOWNER: CAr�dS Cl�n.i7eaaS PHONE: 97-a4aY
CONTRACTOR ADDRESS: &-y A rX -72EVE
ELECTRICIAN:PLUMBER: &.sS Rlu.-L'6j
HVAC: PL C.o.nC"f (VtG�S GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: Qp<\AeA Ce_
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ )qQ, DDO LI/ TOTAL AREA:_!;z4 q3 HEATED AREA: I75
(Cost or Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
�1
dIt
SEWER TAP: `T
SIZE
WATER TAP: 11
SIZE
OTHER TAP:
A SIZE
❑ TEMP POLE
GARAGE TYPE: SINGLE i�
ATTACHED
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE E?� TRIPLE
DETACHED F7 CARPORT
Co► us,�i sk14'e .
a
SIGNATURE OF APPLICANT: l u�T zCA5 U t JAr. b
*If proposed work involves new commercial construction or facade Apr ents/renovations to an existing
commercial property, building elevations are required. t1rn
Official Use Only
71Z V�-ZI-0-7
✓r/p Plans Examiner
�ZVP Z4 C011k,4ucAfto
Zoning Official
C.Qmme
YE or NO
Fire Marshall
W
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D % _
DATE: q _ 3
BUILDING ADDRESS:
e-f& L AI .
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
NA/
NA/
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
Nfiv
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N A 4aK)
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from drivewayto side (intersecting)street property line sight triangle
Drivewayaccess to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N AffK
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
�- 3 �fl
PLANS EXAMINER DATE