HomeMy WebLinkAboutRES2007-01162, 07-116301 0114
09 .IIV3
PREPARED 9/13/07, 8:03:24 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/12/07
------------------------------------------------------------------------------------------------
ADDRESS - 53'0'9 CP;SCADES CT� SUBDIV: PEBBLE CREEK
CONTRACTOR MARIOTT HOMES PHONE `(979) 696-1787
OWNER . . PHONE
PARCEL . . 497900-0946-0500
APPL NUMBER: 07-00001162 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT_ BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/18/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
5/18/07 AP May 17, 2007 11:01:36 AM malford.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 7/10/07 JGM BLDG, FRAMING TIME: 17:00
7/10/07 AP July 10, 2007 8:35:28 AM acarter.
B130 01 7/11/07 OC BLDG, INSULATION TIME: 17:00
7/11/07 AP July 11, 2007 9:10:49 AM glsouth.
B125 01 �9^//}12/ 7 BLDG, FINAL TIME: 17:00
'7li3rG� � C September 12, 2007 4:32:34 PM acarter.
----------------------------------- CONTINUED ONTO NEXT PAGE-----------------------------------
oq_/
Date: 9/13/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1162
Address: 5309 CASCADES CT
Insp.
Inspection Type Code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
6100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
Page 1
WF0893156 / 001 City of College Station PAGE 1
REQ. DATE: 04/27/07 04/27/07 11:47:47
LOCATION: 5309 CASCADES CT LOC ID: 205918
REQUESTOR: MARIOTT HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/411
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07
********************************************************************************
JOB ORDER RESULT COMMENTS
(9/17/2007) Gina Southerland - Re: Calling for C.O. for 5309 Cascades Ct Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 9/14/2007 12:43 PM
Subject: Re: Calling for C.O. for 5309 Cascades Ct
Contacted Marriot Homes at 696-1787.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 9/14/2007 12:41 pm >>>
Water and sewer both need to be raised to grade.
Paul
>>> Amber Carter 9/13/2007 8:26 AM >>>
by 07-1162
any issues?
BUILDING PERMIT
- CITY OF COLLEGE STATIOIri r
1101 TEXAS AVE $
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00001162 Date 4/27/07
Application pin number . . . 521220
Property Address . .
. . . . 5309 CASCADES CT
Property ID:
497900-0946-0500
R #:
R
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 301500
Owner
------------------------
Contractor
------------------------
MARIOTT HOMES
209 ROCK PRAIRIE RD
COLLEGE STATION TX 77845
(979) 696-1787
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 3350.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
TAZ 411.00
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit pin number . 498626
Permit Fee . . . .
1066.00 Plan Check Fee .00
Issue Date . . . .
4/27/07 Valuation . . . . 301500
Expiration Date . .
10/24/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
202.00 3.0000
----------------------------------------------------------------------------
THOU BLDG, VAL 100001-500000 606.00
Special Notes and Comments
ALL BRANCH CIRCUITS THAT
SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY ARC -FAULT CIRCUIT
---------------------------------------------
BUILDING DEPT REPRESENTATIVE:
---- - ----------
APPLICANT: ( I'Nj IA TA'0/0 v
BUILDING PERMIT
' CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001162
Application pin number . . . 521220
Page 2
Date 4/27/07
Special Notes and Comments
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY. I
------------
BUILDING DEPT REPRESENTATIVE:
11 x. � w
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001162
Application pin number . . . 521220
Page 3
Date 4/27/07
Special Notes and Comments
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE.
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL.BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT.WITH CONRETE MUST BE
----------------------------------- ----- - - -----------
BUILDING DEPT REPRESENTATIVE:
- A . - -
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION;
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001162 Date
4/27/07
Application pin number . . . 521220
----------------------------------------------------------------------------
Special Notes and Comments
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed with Interior anchors and
bracing per plans.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
-----------------
----------------------------------------
Permit Fee Total 1066.00 1066.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1816.00 1816.00 .00
.00
BUILDING DE
APPLICANT:
PLUMBING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001095
520500
2901 MCLAREN DR
579530-0207-0050
Date 4/27/07
SLAB ONLY RES. (SF)
SOUTHERN TRACE PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
11405
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. PLUMBING PERMIT
Additional desc .
. NC
Permit pin number
. 498659
Permit Fee . . .
. .00
Plan Check Fee
.00
Issue Date . . .
. 4/27/07
Valuation . . . .
0
Expiration Date .
. 10/24/07
----------------------------------------------------------------------------
Fee summary
-----------------
Charged Paid
Credited
Due
Permit Fee Total
--------------------
.00
--------------------
.00 .00
.00
Plan Check Total
.00
.00 .00
.00
Grand Total
.00
.00 .00
.00
-------------------------------------------
%et - -6-1 - - - - --- - - ---- - - - - - - - - - - -
BUILDING DEPT REPRESENTATIVE: 0.
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION?
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001163 Date
4/27/07
Application pin number . . .
612030
Property Address . . . . . .
5309 CASCADES CT
Property ID:
497900-0946-0500
R #:
R
Application type description
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
MARIOTT HOMES
209 ROCK PRAIRIE RD
COLLEGE STATION
TX 77845
(979) 696-1787
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc KW
Permit pin number 498634
Permit Fee . . . . 20.00
Issue Date . . . . 4/27/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
----------------------------- ----- -
BUILDING DEPT REPRESENTATIVE:
.11 A. A I^
APPLICANT:
(*tl""
CITY OF COLLEGE STATION
Planning d Development Services
ADDRESS/LOCATION
LOT J O '/BLOCK
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV -
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
For Office Use Only
DATE: 4-1m TRCC REG/
APPLICATION # 7:1 " 1 \ (0 d�
TEMP POLE # 1Q�
SEC/PH i
--
PHONE:q)Ph Y7
PHONE: T_/ 7 /
CONTRACTOR ADDRESS: 'e 9dlq
ELECTRICIAN: b/ (J f ��� J (j PLUMBER:
HVAC: ��e/ GOOD CENTS (Residentia only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MpViNG SHELL ONLY
DEMOLITION (Asbestos Survey) 41 KEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION" SWIMMING POOL
Required) I Ccwioej
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TA
%PROJECT REGISTRATIONI#,EABPRJ
VALUATION: $ �lJ/1 �Q%% V TOTAL AREA: 'Z �%?6 HEATED AREA:
(Cost of Labor and Materials)
E—ZKOUBLIC SEWER
SE rC/TREATMENT SYSTEM
SEWER TAP:
6J
WATER TAP:
SIZE
SIZE
OT ER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE El
ATTACHED E��
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F-1
^
DETACHED 1 I
TRIPLE
CARPORT
he��ya�k
SIGNATURE OF APPLICANT: 1 ,rfa /Qmva
*If proposed work involves new commercial co st chi t�or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Onlv
7F,Plans Examiner
WIH
Zoning Official
Comments:
eT5brNO
P�e41 pJA^�s
Energy Code Compliance Information
% Glazing of exterior walls 5
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) _
Glazing SHGCU
Glazing U-Factor
R value of ductwork LQ
A/C SEER Rating
PROPERTY LINE:
12.05'
N 32'43'52" W
PROPERTY LINE:
C=35.30
B=S 53'26'Oq" E
R=50.00'
ol SITE FLAN ��. Nom
LOT: 50
BLOCK: 46
SUBDIVISION:
PEBBLE CREEK
PHASE q-D
COLLEGE STATION, TX
BRAZOS COUNTY
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# _ I
DATE: ! , _/9`o,7
`�
BUILDING ADDRESS:
Sao 9 64sc�l�s
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
ll. Framing:
Floor, Wall, Ceiling and Roof Requirements
NACM
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
40-K
1. One -hour rated extending to roof deck
E.
Header sizes indicated on plans
N AJW
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
Ill. Stairway Requirements
K
890K
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Re uirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAM
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from drivewayto side (intersecting)street property line sight triangle
Drivewayaccess to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
4 -- i -01
PLANS EXAMINER DATE