PREPARED 8/29/07, 11:59:02 INSPECTION TICKET PAGE 9
City/of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/29/07
---j--------------------------------------------------------------------------------------------
ADDkESS . : 5214 BALLYBUNION LN SUBDIV: PEBBLE CREEK
CONTRACTOR MARIOTT HOMES PHONE (979) 696-1787
OWNER . . PHONE
PARCEL . . 497900-0948-0070
APPL NUMBER: 07-00001160 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/09/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
5/09/07 AP May 9, 2007 8:11:46 AM kwolfe.
05/09/2007 03:06 PM RH PDA
Strings up, slab ground installed.
B115 01 6/26/07 RH BLDG, FRAMING TIME: 17:00
6/26/07 AP June 22, 2007 4:19:15 PM acarter.
B130 01 6/27/07 JGM BLDG, INSULATION TIME: 17:00
6/27/07 AP June 27, 2007 7:55:10 AM glsouth.
B125 01 8/29 07 BI BLDG, FINAL TIME: 17:00
giwz August 29, 2007 11:42:13 AM glsouth.
------------------------ ----------
'I
!" a
rnMMV'KTTc nun TTnTPq--------------------------------------
�swig��
v
Date: 8/29/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1160
Address: 5214 BALLYBUNION LN
Insp.
Inspection Type Code
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
05/09/2007 03:06 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
P105
PLBG, TOP OUT
IC
06/22/2007 04:21 PM JGM PDA
P105
PLBG, TOP OUT
IC
not ready
Page 1
WFO893159 / 001 City of College Station
PAGE 1
REQ. DATE: 04/27/07 04/27/07 11:49:40
LOCATION: 5214 BALLYBUNION LN LOC ID: 205930
REQUESTOR: MARIOTT HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/27/07 SCHED COMPLETION: 04/27/07
********************************************************************************
JOB ORDER RESULT COMMENTS
5 BUILDING PERMIT
CITY OF COLLEGE STATION-,
.� 1101 TEXAS'-AVE.
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001160 Date 4/27/07
Application pin number . . . 339600
Property Address . . . . . . 5214 BALLYBUNION IN
Property ID: 497900-0948-0070
R #: R
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 243180
Owner Contractor
------------------------ ------------------------
MARIOTT HOMES
209 ROCK PRAIRIE RD
COLLEGE STATION TX 77845
(979) 696-1787
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2702.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 411.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc KW
Permit pin number 498618
Permit Fee . . . . 892.00 Plan Check Fee .00
Issue Date . . . . 4/27/07 Valuation . . . . 243180
Expiration Date . . 10/24/07
Qty Unit Charge Per Extension
BASE FEE 460.00
144.00 3.0000 THOU BLDG, VAL 100001-500000 432.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing Fully Sheathed.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
------------------------------------------ ------ --- --•- -'------------
BUILDING DEPT REPRESENTATIVE: -
APPLICANT: ( ",A,IU//il Kllnl�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001160
Application pin number . . . 339600
Special Notes and Comments
Page 2
Date 4/27/07
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE ROM TH INSIDE.
A
------------------------------------------- --- - -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001160 Date 4/27/07
Application pin number . . . 339600
----------------------------------------------------------------------------
Special Notes and Comments
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO IN ECTS AND DECAY
--------------------- --. ---- �.1 -- -
BUILDING DEPT REPRESENTATIVE �-
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001160 Date
4/27/07
Application pin number . . . 339600
--------------------------------------------------------------_--------------
Special Notes and Comments
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
-----------------
----------------------------------------
Permit Fee Total 892.00 892-00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1642.00 1642.00 .00
.00
--------------------------------------------- ----- -- --- - ------------
BUILDING DEPT REPRESENTATIVE: �-
APPLICANT: 1. 4AIIAI IMIfIl
'1'EmpuKAKY YULE PEHMiT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001161 Date
4/27/07
Application pin number . . .
430410
Property Address . . . . . .
5214 BALLYBUNION LN
Property ID:
497900-0948-0070
R #:
R
Application type description
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
MARIOTT HOMES
209 ROCK PRAIRIE RD
COLLEGE STATION
TX 77845
(979) 696-1787
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc KW
Permit pin number 498006
Permit Fee . . . . 20.00
Issue Date . . . . 4/27/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Development Semim
FW1NW.�C/STXj�GO%V) j
ADDRESS/LOCATION: JZI`"► I/ I/ %� Q (�
LOT D / BLOCK ��'�SUBDIVISIONJ/P� (�ri SEC/PH
BUSINESS/OWNER NAME: ��iat��jyJP�fr— PHONE: 17 T
CONTRACTOR/HOMEOWNER: y J PHONE: C7,I ��9_ 7) l
CONTRACTOR ADDRESS: �dG1� ��JI%�IP/ Al -
ELECTRICIANN: /�C � �1/ PLUMBER:
HVAC: ?/j� GOOD CENTS (Residential only):
CLASS OF WORK
C� For Office Use Only
DATE: � U��TRCC REG
APPLICATION # � `,�O
TEMP POLE #
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION' SWIMMING POOL
Required) +erg I- I*�oe�
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS)�ROJECT REGISTRATION# EABPRJ
VALUATION: $ � V TOTAL AREA: A� HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
S5PTIC/TREATMENT SYSTEM
1 /I
SEWER TAP:
y
SIZE
WATER TAP:
3/ i,
SIZE
O ER TAP:
SIZE
TEMP POLE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
GARAGE TYPE: SINGLE a OUBLE
ATTACHED DETACAE
TRIPLE
CARPORT EJ
SIGNATURE OF APPLICANT: I (/1/u / ,7=
If proposed work involves new commercial construction or faca a improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
/5 zJ-/
7
V P Plans Examiner
Zoning Official
LGoWaMents.,
(f ES r NO
Energy Code Compliance Information
% Glazing of exterior walls 16 % ✓
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) _✓
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# v
DATE: /1-0 7
BUILDING ADDRESS: tt
I l �rf i a�J Lr
I. Foundation Requirements- Minimum City Foundation
Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier la out shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
_
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
N K
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
NAOR
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
j
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
WOK
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
j
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
I
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
I
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
I
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NACCk
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA(P
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAJOV
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
LANS EXAMINER
4-(.T-Cn
DATE
7' -611
w9m
PROPERTY LINE: 91.20' - N 42-2414711 W
10.0' PUBLIC UTILITY EASEMENT — — —
o25.0' BUILDING SETBACK LINE— — — —
- - - - - - -
O
�i
4` (A
c
r
ul
I i \ 1 —u —u
200=mg
D�>U)
ammUr1
Ntil �()
Z > rn
Ox
I
o,
1
I
/A
4,�.tS�
L �
�
� /�i�f�✓" j - p*'
M y
� Yp11
(
rr i..�`4iht _ ;5
P;F ��tl•+ —fit �.Ya bt .
yS•
®�
G SETBACK—,'
�C
- • - I I
MH-01-148 '"TwAR� �'��� sQ Ft SITE M,4RIOTT HOMES, INC.
.AR AftA 3,43%4 Sa FT FLAN �
RM)EN IAL-COaMwv 10.