HomeMy WebLinkAboutRES2007-01154, 07-542ol*ir*4 oo7oqsv
,E)f0te
WF0890953 / 001 City of College Station PAGE 1
f e
REQ. DATE: 04/20/07 04/20/07 15:07:56
LOCATION: 1040 CRESTED POINT DR LOC ID: 203890
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/20/07 SCHED COMPLETION: 04/20/07
********************************************************************************
JOB ORDER RESULT COMAENTS
PREPARED 7/27/07, 12:05:35 INSPECTION TICKET PAGE 23
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/27/07
--------------------------------------------------------------------------------------------------
ADDRESS !�1040_CRESTED_POINT,,DR _ SUBDIV:
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 650730-0511-0030
APPL NUMBER: 07-00001154 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/14/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
5/14/07 AP May 14, 2007 9:13:46 AM kwolfe.
05/14/2007 03:58 PM RH PDA
Strings up, slab ground installed.
B115 01 6/07/07 JGM BLDG, FRAMING TIME: 17:00
6/07/07 AE June 7, 2007 11:26:13 AM kwolfe.
06/07/2007 04:39 PM JGM PDA
need anchor bolts and nuts at back door and garage returns
B130 01 6/08/07 OC BLDG, INSULATION TIME: 17:00
6/08/07 AP June 8, 2007 9:28:09 AM acarter.
B132 01 6/13/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00
6/13/07 AP June 13, 2007 11:47:18 AM kwolfe.
B125 01 7/26/07 JGM BLDG, FINAL TIME: 17:00
7/26/07 DP July 26, 2007 12:47:11 PM acarter.
07/26/2007 03:47 PM JGM PDA
need address
B125 02 7/27/ 7 BI BLDG, FINAL TIME: 17:00
n July 27, 2007 9:06:21 AM glsouth.
----------------------
kv—----------- COMMENTS AND NOTES --------------------------------------
C®`l
Date: 8/6/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1154
Address: 1040 CRESTED POINT DR
Type
Inspection Type Code
si lus
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
05/14/2007 03:58 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
6115
BLDG, FRAMING
IC
06/07/2007 04:39 PM JGM PDA
B115
BLDG, FRAMING
IC
need anchor bolts and nuts at back door and garage
B125
BLDG, FINAL
IC
07/26/2007 03:47 PM JGM PDA
B125
BLDG, FINAL
IC
need address
M110
MECH, FINAL
IC
July 12, 2007 1:43:00 PM acarter.
Page 1
SHEET:
G-1
AREA
SUMMARY
w w
NO�OmO
dr,T,wu,h�
aa�awa
oo<owo
cc N
O
O U
Q Qz
Pq — O
w � �F
1040 CRESTED POINT DRIVE � w a
WESTFIELD VILLAGE c v x
LOT-3 o
BLOCK - 11
a�
PHASE-5 U aE-E
cn
VF,R SION
# DATE REVISION
0 10/13 MASTER APPROVED
1 1 /10/07 CHANGED 2X6 CEILING JOISTS TO t13 YELLOW PINE
w
z Q
aQC)
dU�-.wd
mr
a z
wUaixu
WME
mi
FRONT ELEVATION
NUM mini
SCALE: 3116"=V-0"w
Q U
wWw w
�1
1
""J,
SHEET INDEX
COVER SHEET
G-1
SITE PLAN
C-1
FINISHING NOTES
SHEET:
C-1
CEDAR FENCE
AREA
�.
SUMMARY
ul
v)(I)cm-n~vo
V.
rjl
V.
= rJ.
3
4.
�o
t
NOC)mo
CN
5.
6.
- N 42004'35" E
<Qwr—T
Van.
w
10 REAR PUE� S��
L
00¢Ow0
_
ss ,
�
1
N
O
p
M
FLA LEAN
'x10'
I
I
1
N
Z —
CONC.
O
PATIO
J
FENCE W/ i
GAT
F N
E
Q Q
W
10
CV
co-
F.PROPOSED
'-�
RESIDENCE
In-
�N
o
� �� a
I
N
j
W e� PA w
W
E-1
jUL+
.��yyT�
< u
�J1�
I
TWO CAR
GA GE
I �
i
I
va
ONT ---
^
a�
11040 CRESTED POINT DRIVE
^
°° cs 49s r.
I �';
WESTFIELD VILLAGE
ay
'LOT-3
1
°
32_62'
i_
BLOCK - 11
PHASE - 5
F
4 3'5' E
�¢
z
Q
Q
C NC. TRUCK 1 ' NC.
WASHOUT °
DRIVE E AL�BOX
Q
Z
H a
HERE
z
1040
WUawow
Q
U
aWw
w
1 SITE PLAN
SCALE: 1 "=20'-0"
Amber Carter - Re: Calling for C.O. @ 1040 Crested Point Dr 1
From: Terry Boriskie
To: Amber Carter; banderson@stylecrak,buil...
Date: 7/30/2007 12:08:20 pm
Subject: Re: Calling for C.O. @ 1040 Crested Point Dr
Stylecraft Builders has been notified.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Mitchell Carson 7/27/2007 1:39 pm >>>
Sewer box buried and water box need s a lid Mitch
>>> Amber Carter 7/26/2007 1:21 PM >>>
by #07-1154
Date: 7/26/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 1154
Address: 1040 CRESTED POINT DR
Insp.
inspection Type code
si ins
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
05/14/2007 03:58 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B115
BLDG, FRAMING
IC
06/07/2007 04:39 PM JGM PDA
B115
BLDG, FRAMING
IC
need anchor bolts and nuts at back door and garage
M110
MECH, FINAL
IC
July 12, 2007 1:43:00 PM acarter.
Page 1
BUILDING PERMIT
CITY OF COLI;EGE _ITATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------'-----------------------------------
Application Number . . . . . 07-00001154 Date 4/20/07
Application pin number . . . 900974
Property Address . . . . . . 1040 CRESTED POINT DR
Property ID: 005401-0511-0030
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 77616
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1176.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
GS
Permit pin number
496349
Permit Fee
372.00 Plan Check Fee
.00
Issue Date
4/20/07 Valuation . .
. . 77616
Expiration Date
10/17/07
Qty Unit Charge
Per
Extension
BASE FEE
260.00
28.00 4.0000
THOU BLDG, VAL 50001-100000
112.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY ARC -FAULT CIRCUIT
BUILDING DEPT REPRES�idT'1jIVE
----�-----------
- �
APPLICANT:
BUILDING PERMIT
CITY OF COLLgGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001154
Application pin number . . . 900974
Page 2
Date 4/20/07
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH M SUR- /6, _je
ED THE .
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLF-GE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00001154 Date 4/20/07
Application pin number . . . 900974
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLF'GE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00001154 Date
4/20/07
Application pin number . . . 900974
----------------------------------------------------------------------------
Special Notes and Comments
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 372.00 372.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1122.00 1122.00 .00
.00
--------------------------------------A-
64or ---- ------------------
BUILDING DEPT RE SE TATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000542 Date 4/20/07
Application pin number . . . 026962
Property Address . . . . . . 1040 CRESTED POINT DR
Property ID: 005401-0511-0030
R #.
Application type description TEMP POLE
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
496356
Permit Fee
20.00
Issue Date . . .
. 4/20/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
------------------------------------- - - - --- ✓ -----�-----------
BUILDING DEPT REPRE TA IVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
(W., CITY OF COLLEGE STATION
i 101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CPTYOF COLLEGESTAnON (979) 764-3570 (979) 764-3496 FAX
P1=.iagc-Deo1np=,tS TZw WWW.CSTX.GOV
For`06'i use Onh/
DATE 0" `5TI(P REG
APPLICATION # \\ -EY
III
TEMP POLE # J� it
ADDRESS/LOCATION: 1040 GZV--STf:-D 1-4T V/ /
LOT 3 BLOCK j I SUBDIVISION W �STF1 LD V ll--L,gGIE SEC/PH 5 J
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext.120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext.120
CONTRACTOR ADDRESS: 4090 State Hiahwav 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) H
NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK. Conventional Framing
STRUCTURE USE: Sinale Famiiv Residence 11
HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N��4
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ i L G TOTAL AREA: L (009 HEATED AREA: 11 ^7 Co
(Cost of Labor and Materials)
ZO X PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
nX SEWER TAP: 40
SIZE
❑X WATER TAP: 4"
SIZE
OTHER TAP:
TEMP POLE
VGARAGE TYPE:
SIZE
SINGLE 0
ATTACHED aX
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
DETACHED EJ
TRIPLE
CARPORT
3
Sheet Rock
Siding and/or Masonry
Slab on Grade
COMDOsition
I�
SIGNATURE OF APPLICANT: . C91 For S lecraft
*If proposed work involves new commerclW construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
oee000ee0000eoeeoeoeo.000000000000000e0000000e00000000000e000
Official Use Only
-1-;9 YES oreNO
/ Plans Examiner Zoning Offic!aV
.SIB -7sl Pft-f OW
1 1—
Energy Code Compliance Information
% Glazing of exterior walls I O %
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 (flat areas) R30�
Insulation R value of ceiling 2 (vaulted areas/no attic) R19
Glazing SHGC .40
Glazing U-Factor .65
R value of ductwork R6
.AJC SEER Rating 13 )
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D _ 11
S
DATE: _ �� `�
BUILDING ADDRESS: /0 L/ 0 ne'o 'S 4rej /-'1-10' y'4
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
IK
E.
Header sizes indicated on plans
NA/PA
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
OK
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
tINWOK
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NK/AW
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
. k4A
NS EXAMINER
�r g,-O�7
DATE
1
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Plan # 1176-WVCO
Report Date: 04/17/07
Data filename: S:\ACAD\Archived\Old REScheck\1 1761040 Crested Point.cck
Energy Code:
2000 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
10%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Permit Date: 04-17-2007
Maximum SHGC: 0.40 Your SHGC: 0.40
Designer/Contractor:
Permit #
Permit Date
Ceiling 1: Flat Ceiling or Scissor Truss:
957 30.0 0.0
33
Ceiling 2: Cathedral Ceiling (no attic):
219 19.0 0.0
11
Wall 1: Wood Frame, 16" o.c.:
1160 13.0 0.0
83
Window 1: Metal Frame, Double Pane with Low-E:
95
0.670 64
SHGC: 0.40
Door 1: Solid:
38
0.500 19
Door 2: Glass:
18
0.440 8
SHGC: 0.40
Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
145 0.0
151
Air Conditioner 2: Electric Central Air: 13 SEER
Furnace 2: Forced Hot Air: 80 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans,
specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
g" Q . cseQsTy Lr-CA2AFT
gutUPE--��,10C •
4 200
Builder/signer Company Name
Date
Project Notes:
Previously saved project information:
Spec
1040 Crested Point Drive
College Station, Texas
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
Plan # 1176-WVCO
Page 1 of 1