HomeMy WebLinkAboutRMDL2007-01133D-1 -- � V��)
BUILDING PERMIT
CITY OF COLLEGE STATION ,
C�1101 TEXAS AVE
LLEGE STATION, TX 77840
PHONE: (99)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00001133 Date
4/18/07
Application pin number . . . 964361
Property Address . . . . . . 1011 DOMINIK DR
Property ID: 670600-0000-0165
R #: R49758
Tenant nbr, name . . . . . . FOUNDATION REPAIR
Application type description RESIDENTIAL, REMODEL & RENOVATION
Subdivision Name . . . . . . WOODLAND ESTATES
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 3500
Owner Contractor
------------------------ ------------------------
MIKEAL, ORAN D & JANET F ANCHOR PIERS, LLC.
1011 DOMINIK DR 2924 CAIN RD
COLLEGE STATION TX 778403613 COLLEGE STATION
TX 77845
(979) 219-2774
--------------------- Structure Information 000 000 ----------------------
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . IMPACT/PRORATA FEES PAID NA
HEATED AREA
1.00
INTERIOR WALL TYPE NA
TAZ
242.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . NC
Permit pin number . 495861
Permit Fee . . . . 30.00 Plan Check Fee
.00
Issue Date . . . . 4/18/07 Valuation . . . .
3500
Expiration Date . . 10/15/07
Qty Unit Charge Per
Extension
BASE FEE
15.00
3.00 5.0000 THOU BLDG, VAL 1001-50000
15.00
----------------------------------------------------------------------------
Special Notes and Comments
10 Foundation Repair Piers
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----- - -- - '-- - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT: K'e/ , J %
BUILDING PERMIT
`CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application
Number . . . . .
07-00001133
Date 4/18/07
Application
pin number . . .
964361
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee
Total 30.00
30.00
.00
.00
Plan Check
Total .00
.00
.00
.00
Grand Total
30.00
30.00
.00
.00
---------------------
BA.- UILDING DEPT REPRESENTATIVE: / A
A
APPLICANT:
APR-16-2007 10:44 AM ANCHOR PIER LLC
P.01
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
Crrx � S (979) 704.3670 (979) 7044490 FAX
WWW1C8TX1GOV
ADDRESS/LOCATION:
'Opu/O4_1
DATE; • '
APPLICATION P
TEMP POLE M
LOT BLOCK - SUBDIVISION SEC/PH
BUSINESS/OWNER NAME: 4/,0,4j All j ' q
PHONE:
CONTRACTOR/HOMEOWNER: A _L. oj G�f oNE:7 '7,C,
CONTRACTOR ADDRESS; -z 2 t7,
ELECTRICIAN: PLUMBER:
HVAC:
(3000 CENTS (Residential only):
CLA88 OF WORK
""-
ACCESSORYISTORAGE
LOCATION,
RE -ROOF
ADDITION
MOVING
SHELL ONLY
DEMOLITION (Asbestos Survey)
NEW CONSTRUCTION •
SLAB ONLY
DUPLEX (Landscape Plans
REMODEL/RENOVATION-
SWIMMING POOL
Required)
DF„ $CRIPTION OF WORK: b
STRUCTURE USE:'
HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 0 G TOTAL AREA: HEATED AREA:
(Cost dF Labor and Materials)
PUBLIC SEWER
NUMBER OF BEDROOMS;
SEPTIC/TREATMl NT SYSTEM
NUMBER OF BATHROOMS;
SEWER TAP:
INTERIOR WALL TYPE:`
SIZE
a WATER TAP:
EXTERIOR WALL TYPE:
SIZE
OTHER TAP:
FOUNDATION TYPE:
SIZE
. TEMP POLE
ROOF TYPE:
GARAGE TYPE: SINGLE
DOUBLI: TRIPLE
A't'T'ACHED
ETACHED a CARPORT
7/11
SIGNATURE OF APPLICANT: L'�—
•If proposed work Involves new com rcial construction dAltede improvements/renovations to an exist
commercial property, building elevations are required,
♦11��11111����1111111i♦�1111���1111111�����11111�111111��•.�♦
{ J
� "� �`7
Ofticlal Use Only
giants:
_. 'Zor NO
Plans Examiner
Zoning Official
APR-16-2007 10:44 AM ANCHOR PIER LLC
P. 02
2924 Cain Road
College Station, TX 77845 100
Office: (979) 690.2020 date; %� �
Fax: (979) t39t)-0235 AGREEMENT
Anchor Piers LL0, called Contractor, and _ y' / i� ' / �� —
c� �
Owner agree that the sum
of $ 14 _ , to be paid as follows: after piers are poured, balance on completion.
Contractor will fumish labor, equipment and materials to perform the following described work to the hereinafter described
building or structure located at: 1�b li 7�AJ<,x i Story Structure
Phone (H) (W)
1. The work shall consist of the Installation of /0 piers with nine inch diameter shafts drilled to 8" to 12' , water
table rocks and/or man placed objects permitting. The bottom of the shaft will have a bell footing of 20 inches in
diameter, unless rock is encountered.
2. Contractor assumes no responsibility for any under slab plumbing. It may currently be cracked, broken, deterlo-
rated or may do so In the leveling process. Any repairs, If required are the sole responsibility of the owner.
3. Job alto will be clean of all excess dirt and material.
4. Contractor will carry all required Insurance,
5. When inside piers are called for, contractor will patch floors, Patches will be made with concrete to wooden floor
level. Carpet will NOT be stretched,
6. Where surfaces such as concrete floors or patios are broken In order to install piers, Contractor will patch such
area. The patches, however, will not match he color or texture of the original material, Special surface such as
Flagstone, Spanish Tile, Brick or other such special materials will be restored at a cost in addition to pier Installa-
tion.
7. In foundation leveling, conditions might appear when work Is begun that were not visible when estimate was
submitted, such as, insufficient reinforcing steel In concrete slab, and/or other original foundation structural
deficiency. In such cases the guarantee becomes invalid.
8. SPECIAL, PROVISIONS: No Subcontractors. (� �� FIZ b�%2-
9. LIFETIME SERVICE AGREEMENT. If any raising Is necessary due to settling during the first five years from date
of completion of the job, Contractor will re -raise the settled area without cost to the OWNER. For additional
years, servicing, If required, will be done at the rate of =per adjusted pier, labor and materials Included,
plus or minus the U.S. Consumer Price Index each year. This service agreement applies only to the piers
Installed by Contractor.
THIS AGREEMENT TRANSFERABLE TO NEW OWNERS. NOTIFICATION MUST BE TENDERED IN WRITING
WITHIN 30 DAYS OF OWNERSHIP.
It Is understood agreed that in order to perform the above described work It is possible that sheetrock, wallpaper, or other
rigid material may crack. Therefore, the above figure does not include any redecorating, repairing, electrical work or the
replacement of any material not called for In this agreement. Contractor upon request from owner, will transplant plants
and shrubs obstructing operations, and replace same, surviy8l gf ahru�j god plants cannot be guaranteed.
It Is understood and agreed that Contractor will furnish all the labor, equipment and material and will perform all necessary
work In connection with this job, in a good workmanlike manner.
The Owner may order extra work to be done not contemplated by the contract. In which event, a separate Agreement for
such work shall be entered between the Owner and the Contractor. No oral representation made by anyone can change
or modify this Agreement. This Agreement in order to be binding by both parties, must be signed In the space provided
below, and the original copy returned to this office within �._ days from the date shown above.
Anchor Piers LC
Owner Manager
APR-16-2007 10:45 AM ANCHOR PIER LLC 1 P.03
VIER FO UNDA TION DETAILS
FOA REPAIR ONLY TO DAMAGED FOUNDATIONS WHERE SPECIFICALLY DESIGNATED
EXISTING SLAG A SEAM
r` GRADE
SHIM & GROUT 7
!" x 12" {�
SOLID CONC.
BLOCKS
b - 04 RODS "
i EACH WAY 4-!* r
ALL CONCRETE
TO BE 5 SACK
W/ 1.1/2" ROCK
H
$IDE VIEW
21"
STABLE
CLAY
w
1"MIN 8" 1"MIN,
JACK
SPACII
POUR CAPS
FOOTING AT
THE SAME
TIME
2'2"
a"1 8 - 01 VERT,
L W/ 02 TIES A 180O.C.
4
t ir,
8" OIAM.
f
T 1
40" buM.
FRONT VIEW