HomeMy WebLinkAboutRMDL2007-01133D-1 -- � V��) BUILDING PERMIT CITY OF COLLEGE STATION , C�1101 TEXAS AVE LLEGE STATION, TX 77840 PHONE: (99)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001133 Date 4/18/07 Application pin number . . . 964361 Property Address . . . . . . 1011 DOMINIK DR Property ID: 670600-0000-0165 R #: R49758 Tenant nbr, name . . . . . . FOUNDATION REPAIR Application type description RESIDENTIAL, REMODEL & RENOVATION Subdivision Name . . . . . . WOODLAND ESTATES Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 3500 Owner Contractor ------------------------ ------------------------ MIKEAL, ORAN D & JANET F ANCHOR PIERS, LLC. 1011 DOMINIK DR 2924 CAIN RD COLLEGE STATION TX 778403613 COLLEGE STATION TX 77845 (979) 219-2774 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 1.00 INTERIOR WALL TYPE NA TAZ 242.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . NC Permit pin number . 495861 Permit Fee . . . . 30.00 Plan Check Fee .00 Issue Date . . . . 4/18/07 Valuation . . . . 3500 Expiration Date . . 10/15/07 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 5.0000 THOU BLDG, VAL 1001-50000 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 10 Foundation Repair Piers ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ----- - -- - '-- - - - - - - BUILDING DEPT REPRESENTATIVE: APPLICANT: K'e/ , J % BUILDING PERMIT `CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 07-00001133 Date 4/18/07 Application pin number . . . 964361 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 30.00 30.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 30.00 30.00 .00 .00 --------------------- BA.- UILDING DEPT REPRESENTATIVE: / A A APPLICANT: APR-16-2007 10:44 AM ANCHOR PIER LLC P.01 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 Crrx � S (979) 704.3670 (979) 7044490 FAX WWW1C8TX1GOV ADDRESS/LOCATION: 'Opu/O4_1 DATE; • ' APPLICATION P TEMP POLE M LOT BLOCK - SUBDIVISION SEC/PH BUSINESS/OWNER NAME: 4/,0,4j All j ' q PHONE: CONTRACTOR/HOMEOWNER: A _L. oj G�f oNE:7 '7,C, CONTRACTOR ADDRESS; -z 2 t7, ELECTRICIAN: PLUMBER: HVAC: (3000 CENTS (Residential only): CLA88 OF WORK ""- ACCESSORYISTORAGE LOCATION, RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION • SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION- SWIMMING POOL Required) DF„ $CRIPTION OF WORK: b STRUCTURE USE:' HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 0 G TOTAL AREA: HEATED AREA: (Cost dF Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS; SEPTIC/TREATMl NT SYSTEM NUMBER OF BATHROOMS; SEWER TAP: INTERIOR WALL TYPE:` SIZE a WATER TAP: EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: SIZE . TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE DOUBLI: TRIPLE A't'T'ACHED ETACHED a CARPORT 7/11 SIGNATURE OF APPLICANT: L'�— •If proposed work Involves new com rcial construction dAltede improvements/renovations to an exist commercial property, building elevations are required, ♦11��11111����1111111i♦�1111���1111111�����11111�111111��•.�♦ { J � "� �`7 Ofticlal Use Only giants: _. 'Zor NO Plans Examiner Zoning Official APR-16-2007 10:44 AM ANCHOR PIER LLC P. 02 2924 Cain Road College Station, TX 77845 100 Office: (979) 690.2020 date; %� � Fax: (979) t39t)-0235 AGREEMENT Anchor Piers LL0, called Contractor, and _ y' / i� ' / �� — c� � Owner agree that the sum of $ 14 _ , to be paid as follows: after piers are poured, balance on completion. Contractor will fumish labor, equipment and materials to perform the following described work to the hereinafter described building or structure located at: 1�b li 7�AJ<,x i Story Structure Phone (H) (W) 1. The work shall consist of the Installation of /0 piers with nine inch diameter shafts drilled to 8" to 12' , water table rocks and/or man placed objects permitting. The bottom of the shaft will have a bell footing of 20 inches in diameter, unless rock is encountered. 2. Contractor assumes no responsibility for any under slab plumbing. It may currently be cracked, broken, deterlo- rated or may do so In the leveling process. Any repairs, If required are the sole responsibility of the owner. 3. Job alto will be clean of all excess dirt and material. 4. Contractor will carry all required Insurance, 5. When inside piers are called for, contractor will patch floors, Patches will be made with concrete to wooden floor level. Carpet will NOT be stretched, 6. Where surfaces such as concrete floors or patios are broken In order to install piers, Contractor will patch such area. The patches, however, will not match he color or texture of the original material, Special surface such as Flagstone, Spanish Tile, Brick or other such special materials will be restored at a cost in addition to pier Installa- tion. 7. In foundation leveling, conditions might appear when work Is begun that were not visible when estimate was submitted, such as, insufficient reinforcing steel In concrete slab, and/or other original foundation structural deficiency. In such cases the guarantee becomes invalid. 8. SPECIAL, PROVISIONS: No Subcontractors. (� �� FIZ b�%2- 9. LIFETIME SERVICE AGREEMENT. If any raising Is necessary due to settling during the first five years from date of completion of the job, Contractor will re -raise the settled area without cost to the OWNER. For additional years, servicing, If required, will be done at the rate of =per adjusted pier, labor and materials Included, plus or minus the U.S. Consumer Price Index each year. This service agreement applies only to the piers Installed by Contractor. THIS AGREEMENT TRANSFERABLE TO NEW OWNERS. NOTIFICATION MUST BE TENDERED IN WRITING WITHIN 30 DAYS OF OWNERSHIP. It Is understood agreed that in order to perform the above described work It is possible that sheetrock, wallpaper, or other rigid material may crack. Therefore, the above figure does not include any redecorating, repairing, electrical work or the replacement of any material not called for In this agreement. Contractor upon request from owner, will transplant plants and shrubs obstructing operations, and replace same, surviy8l gf ahru�j god plants cannot be guaranteed. It Is understood and agreed that Contractor will furnish all the labor, equipment and material and will perform all necessary work In connection with this job, in a good workmanlike manner. The Owner may order extra work to be done not contemplated by the contract. In which event, a separate Agreement for such work shall be entered between the Owner and the Contractor. No oral representation made by anyone can change or modify this Agreement. This Agreement in order to be binding by both parties, must be signed In the space provided below, and the original copy returned to this office within �._ days from the date shown above. Anchor Piers LC Owner Manager APR-16-2007 10:45 AM ANCHOR PIER LLC 1 P.03 VIER FO UNDA TION DETAILS FOA REPAIR ONLY TO DAMAGED FOUNDATIONS WHERE SPECIFICALLY DESIGNATED EXISTING SLAG A SEAM r` GRADE SHIM & GROUT 7 !" x 12" {� SOLID CONC. BLOCKS b - 04 RODS " i EACH WAY 4-!* r ALL CONCRETE TO BE 5 SACK W/ 1.1/2" ROCK H $IDE VIEW 21" STABLE CLAY w 1"MIN 8" 1"MIN, JACK SPACII POUR CAPS FOOTING AT THE SAME TIME 2'2" a"1 8 - 01 VERT, L W/ 02 TIES A 180O.C. 4 t ir, 8" OIAM. f T 1 40" buM. FRONT VIEW