HomeMy WebLinkAboutSLAB2007-01096arsselte
R 7521/3 M R
BUILDIlLS-P.EaNIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00001096
674400
4102 MCLISTER DR
579530-0208-0020
Date 4/16/07
SLAB ONLY RES. (SF)
SOUTHERN TRACE PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
11286
Owner Contractor
------------------------ ------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit pin number 494971
Permit Fee 70.00 Plan Check Fee .00.
Issue Date 4/16/07 Valuation . . . . 11286
Expiration Date 10/13/07
Qty Unit Charge Per Extension
BASE FEE 15.00
11.00 5.0000 THOU BLDG, VAL 1001-50000 55.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
Per section R106.3.3, 2003 IRC and section 106.3.3 2003
IBC, proceed with foundation work at own risk without
assurance that further permits will be issued.
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
THERE SHALL BE NO COMBUSTIBLE OR FLAMMABLE MATERIALS
-------------------------- ------------------
BUILDING DEPT REPR N TIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
2
Application Number . . . . . 07-00001096 Date
4/16/07
Application pin number . . . 674400
----------------------------------------------------------------------------
Special Notes and Comments
PLACED ON SITE, LOT OR SUBDIVISION WHERE WATERLINES AND
FIRE HYDRANTS AS REQUIRED BY THE APPLICABLE SUBDIVISON
REGULATIONS ARE NOT COMPLETED AND IN SERVICE AND WHERE
ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES DOES NOT EXIST
TO WITHIN ONE HUNDRED FIFTY FEET (1501) OF THE MOST
REMOTE PART OF THE STRUCTURE. (IFC section 501.4)
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 70.00 70.00 .00
.00
Plan Check Total .00 .00 .00
.00
Grand Total 70.00 70.00 .00
.00
--------------------------------------------- ------ ---- ------ ----- - - - - - -
BUILDING DEPT REPRE TA I
APPLICANT: r
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d-DnrlopmcntSrrvim WWw CSTX.GOV
For Office
099 UqO{ry 2l /�^
DATE: TRCCi EG "y /
APPLICATION #
TEMP POLE #
ADDRESS/LOCATION: �I o2 M cL_ I j% C-
LOT Z ✓BLOCK V SUBDIVISION SOUTHERN TRACE ✓ SEC/PH 2
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS. INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highwav 6 South
ELECTRICIAN: To Be Determined PLUMBER: Bass Plumbing
HVAC: To Be Determined GOOD CENTS (Residential only):
CLASS OF WORK
No
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * X SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Slab on Grade
STRUCTURE USE: Single Family Residence
WALL BRACING METHOD: PRESCRIPTIVE APA PORTAL FRAME W/ CSPS ❑ ENGINEERED OX
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N/A
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ NIA
VALUATION: $ 11.286 ell" TOTAL AREA: 1949 HEATED AREA: 1710
(Cost of Labor and Materials)
�X PUBLIC SEWER
10 SEPTIC/TREATMENT SYSTEM
SEWER
SIZE
SIZE
OTHER TAP:
SIZE
GARAGE TYPE: SINGLE El
ATTACHED
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE TRIPLE
IET412LED CARPORT
4
4
Sheet Rock
Siding and/or Masonry
Slab on Grade
ComDOSltion
71
SIGNATURE OF APPLICANT: qL12107 For St lecraft
*If proposed work involves new commer const or faca a improve ent /renovations to an existing
commercial property, building elevations are required
Official Use Only
(� mments:
— T 1 7 YE NO
Plans Examiner Zoning Official
— Sf oily
NCI
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
12%
R13
R30
R19
.40
.65
R6
13
N 41 `10'32' E
w'
UI
Z
W
LL
I .Is.
I I I IV
I11 1Im-
I 1 I 'IN
iiLu
I I I
1 I I I 1
Imo. i IV SET — K 14102 MCLISTER DRIVE
�, SOUTHERN TRACE
M 1 UE 3� °' LOT - 2
BLOCK - 8
94 SF 869 SF PHASE - 2
4012 MCLISTER
I=
I LOCATION
W
1 SITE PLAN
SCALE:1"=20'-V
C-1
SITE PLAN
SOUTHERN TRACE SUBDIVISION
FOUNDATION NOTES AND DETAILS
GENERAL NOTES
1. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH THE WORK REPORT ANY DISCREPANCIES
OR VARIATIONS FROM THE DRAWINGS TO THE ENGINEER FOR ANY REVISIONS THAT MAY BE REWIRED.
2. REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR ELEVATIONS, SLOPES, DEPRESSED FLOOR AREAS, FINISHES, AND EMBEDDED ITEMS
FOUNDATION AND SUBGRADE SPECIFICATIONS
1. REMOVE SURFACE VEGETATION, ROOTS, ORGANIC MATERIALS TO A DEPTH OF 5. THE EXPOSED SURFACE SWILL SE VISUALLY CHECKED AND ANY SOFT OR
WEAK AREAS SHALL BE REMOVED AND PLACED BY COMPACTED FILL
2. COMMON FILLS SOBS SHALL CONSIST OF SOILS FROM THE SITE OR SOIL OF SIMILAR CHARACTERISTICS OBTAINED FROM OTHER SITES SELECT FILL SOIL
(NATURAL SOURCE) SHALL BE FREE OF ORGANIC MATERIALS, A PLASTICITY INDEX OF LESS THAN 20.
L FILL MATERIALS SHALL BE PLACED BY BOX BLADE OR FRONT END LOADER AND COMPACTED SUFFICIENT ENOUGH TO SUPPORT GRADE BEAM EXCAVATION AND
CONCRETE PLACEMENT LOADS.
4. AFTER STRIPPING, BRING BUILDING PADS TO FINAL GRADE BYADDITION OF SELECT FILL MATERIAL
L PROVIDE S MIL THWACIESS WATERPROOFING BENEATH ALL BUILDING FOUNDATIONS AND SLABS. MATERIAL SHALL BE VIRGIN POLYETHYLENE PLASTIC FILM.
OVERLAP Zr
AT ALL JONTS.
REINFORCING STEEL SPECIFICATIONS
N 1. ALL REFORGNG STEEL SHALL BE NEW BILLET DEFORMED BARS CONFORMING TO ASTM AWS, GRADE 50, EXCEPT SO BARS WHICH ARE BEM (SUCH AS
STIRRUPS, TIES, OR DOWELS) MAY BE GRADE 40. WELDED WARE FABRIC SHALL CONFROM TO ASTM A185. ALL REINFORCING SHALL BE CLEAN AND FREE OF MILL
SCALE
2. DETAILING AND FABRICATION OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE, ACI 315. UNLESS SHOWN
OTIRERYNISE, LAP CONTINUOUS BARS 30 BAR DIAMETERS AT SPLICES, 12 INCHES MINIMUM.
3. REINFORCING BARS MAY NOT BE WELDED WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER.
4. ALL TOP REINFORCEMENT SHALL HAVE CORNER BARS RACED WITH THEM THAT EXTEND INTO ADJACENT BEAMS AND AT BOTTOM AS REQUIRED BY CODE
5. PROVIDE NECESSARY TIES AND BAR SUPPORTS AS REWIRED SY THE MANUAL OF STANDARD PRACTICE, AC 315. CHAIRS AND BOLSTERS FOR APPLICATION
DIRECTLY OVER EARTH, POLY SHEETS, OR FELTS SHALL BE EQUIPPED WITH BOTTOM BEARING PLATES
5. CONCRETE COVERAGE FOR THE REINFORCING STEEL SHALL COMPLY WITH THE 1IIB AC CODE,
7. WHERE THE GEOMETRIC CONFIGURATIONS OF SLABS FORM INSIDE CORNERS, PROVIDE DIAGONAL REINFORCING ACROSS THESE CORNERS. EXCEPT WHERE
SHOWN OTHERWISE, THIS REINFORCING SHALL BE 3413 BARS X S-0• LONG ® 4' ON CENTER AT EACH SUCH CORNER PLACED WITH TYPICAL SLAB REINFORCING.
CASs IN PLACE CONCRETE SPEgFICATKINS
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AC 315.
2. ALL CONCRETE SHALL BE NORMAL WEIGHT (SAND AND GRAVEL AGGREGATE) WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,OD0 PSI.
3. NO HOR¢ONTAL JOINTS WILL BE PERMITTED IN CONCRETE WORK EXCEPT AS SHOWN ON THE DRAWINGS ANY STOP IN CONCRETE PLACEMENT WILL BE MADE
WITH
VERTICAL BULKHEADS INCORPORATING A SHEAR KEY ATCENTFRS OF SPANS. LOCATIONS FOR STOP POINTS SHALL BE APPORVED BY THE STRUCTURAL
ENGINEER PRIOR TO THE PLACEMENT.
4. FORMWORK DESIGN IS THE RESPONSIBILITY OF THE CONTRACTOR MID SHALL NOT BE REMOVED UNTIL THE CONCRETE HAS GAINED SUFFICIENT STRENGTH TO
CARRY ITS OWN WEIGHT PLUS APPLIED CONSTRUCTION LOADS.
5. UNLESS OTHERWISE NOTED, CONCRETE COVER FOR REINFORCING STEEL SHALL BE
GRADE BEAMS - 3• BOTTOMk 2• SIDES AND TOP
FLOOR SLABS - 2-
L ALL PENETRATIONS AND SLEEVED HOLES SHALL BE APPROVE) BY THE STRUCTURAL ENGINEER
7. CONCRETE PLACEMENT SHALL BE ACCOMPLISHED BY DIRECT CHUTE FROM THE MIXER TRUCK OR BY PUMPING TO ITS FINAL POINT OF DEPOSIT. CONCRETE
SHALL NOT BE DRUG BY HAND MORE THAN 5 FEET.
S. CONSOLIDATE CONCRETE BY PROPER USE OF MECHANICAL VIBRATOR
DESIGN dRITERw
THE FOUNDATION HAS BEEN DESIGNED N ACCORDANCE WITH THE REFERENCED GEOTECHNICAL ENGINEERS REPORT FOR THE PROJECT AREA AND FEDERAL
HOUSING ADMINISTRATION REQUIREMENTS. NO OTHER WARRANTY OR GUARANTEE EXPRESS OR IMPLIED IS PROVIDED. A SITE SPECIFIC GEOTECHNICAL
ENGINEERING STUDY AND REPORT FOR THIS PARTICULAR PROJECT HAS NOT BEEN COMMISIONED OR ACCOMPLISHED.
RE -BAR SPECS NOTE: ALL GRADE BEAMS MUST BE AT QUICK COUNT
BAR MN.I V MIN. RADIUS LEAST 6" INTO UNDISTURBED NATURAL TOP BARS 4 #5
Sm INCHES OF BENDS GROUND.
s BOTTOM BARS 4 #5
15• - / BEAM WIDTH 1411
21°s 2-5/e° EXTERIOR BEAM DEPTH 30"
#
IINTERIOR BEAM DEPTH 30"
y SLAB
Od =--- -- -- - -_--- ROP
O� #3 BARS @ 14' O.C.E.W.
\ #3 STIRRUPS @ 36" O.C.
D j\ j d _ i , 4 #5 BARS TOP & BOTTOM
NZ �\ (� \; 6 MIL POLY W.P.
\ \ \ \ SELECT FILL
`tt O R BEAM � INTERIOR SLAB DROP
BRICK 8' x 1/2' ANCHOR BOLTS
LE GE- 2-1/2" ABOVE F.F.Q 48" O.C.
AND WITHII`j 12:OFDOOR
O�
f T-- -
\ • p
\ti BARS @ 14' O.W, \ofco
wmm
Oa Ow
#3 STIRRUPS @ .
22
:�4#
BARS TOP & BOTTOM
NZ / \� 6 MIL POLY W.P.
SELECT FILL
3 EXTERIOR BEAM @ BRICK LEDGE 7 EXTERIOR BEAM (a) EXTERIOR WALL
BRICK LEDGE + - 8" x 1/2" ANCHOR BOLTS 3/8" SMOOTH
(IF REQUIRED 2 1/2" ABOVE F.F. 0 48" O.C. DOWEL WHERE
ARIES AND 5" FROM DOOR OPENING FLATWORK ABUTTS
OO�__---- --- -a
///.�///�/ 20
° I to
�DO \ I I , #3 BARS @ 14' O.C.E.W. \ I to dm
Oj "I I ° #3 BARS @ 12" O.C. ; " %\ O?
�� �/ I I :4#513AR
TIRRUPS @ 36' O.C. gt~—nNj S TOP &BOTTOM //
6 MIL POLY W.P. / "
- SELECT FILL
UEXTERIOR BEAM CDC GARAGE BRICK LEDGE 5 EXTERIOR PBEAM 0 GARAGE BRICK LEDGE
26'-9"'
1.
N
N
DRAM FOR M FLOOR
I�I I I CRJTr'AL LOCATIONIII
I II I
I I I N ID
v
L- - -J L -- --''
1a-6 -
N -1 F
co
19
I I I I
I I
2
N 2NDnoxm FLOOR I I 1•
2'-
2
wcAI
f9
I II I
L_ JL—_____J
m
r — —
II I
I II I
uil
II I
I I
co
-
10
M
1 FO/UNDATION PLAN
E_1
FAJ .
ILOCATIONI
•&_
.S-1
FOUNDATION PLAN