Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-01092, 07-1093
rn- logs c+�� 4. 13Pendaffe,yr aEsse/% R 7521/3 10% P4 PREPARED 9/11/07, 7:54:56 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/10/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 3817 NIGHT RAIN DR SUBDIV: WESTFIELD VILLAGE PH 6 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650730-0614-0300 APPL NUMBER: 07-00001092 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/24/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 5/24/07 AP May 24, 2007 11:01:24 AM acarter. 05/24/2007 03:39 PM RH PDA Strings up, slab ground installed. B115 01 7/20/07 OC BLDG, FRAMING TIME: 17:00 7/20/07 DP July 19, 2007 9:37:39 AM acarter. Sheetrock Fireplace Chase, Firestopping 07/20/2007 01:08 PM OC PDA missing some anchor nuts.needs [x] bracing on back wall per plans.[x] bracing in garage incorrect . -B115 02 7/23/07 JGM BLDG, FRAMING TIME: 17:00 7/23/07 DA July 23, 2007 11:03:40 AM acarter. 07/23/2007 04:36 PM JGM PDA not ready B115 03 7/24/07 RH BLDG, FRAMING TIME: 17:00 7/24/07 AP July 24, 2007 10:37:36 AM glsouth. B130 01 7/26/07 JGM BLDG, INSULATION TIME: 17:00 7/26/07 AP July 26, 2007 8:20:48 AM malford. B132 02 7/30/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00 7/30/07 AP July 30, 2007 11:36:46 AM acarter. B132 01 7/30/07 OC BLDG, SHEETROCK FASTENER TIME: 17:00 7/30/07 DP July 27, 2007 11:13:26 AM glsouth. monday morning Not Ready For Inspection B125 01 9/ 0/7 BLDG, FINAL TIME: 17:00 q10ii ( ADC September 10, 2007 4:50:15 PM glsouth. -------------------------------------- COMMEN S AND NOTES -------------------------------------- Date: 9/11/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 1092 Address: 3817 NIGHT RAIN DR Inspection Result Comments 05/24/2007 03:39 PM RH PDA Strings up, slab ground installed. Sheetrock Fireplace Chase, Firestopping 07/20/2007 01:08 PM OC PDA missing some anchor nuts.needs [x] bracing on back wall per plans.[x] bracing in garage incorrect . 07/23/2007 04:36 PM JGM PDA not ready Not Ready For Inspection 07/11/2007 02:41 PM RH PDA Make sure light fixtures in bathrooms have 3ft min. from tubs edge. Finish installing exhaust fans. Bond GASTITE gasline as per manufacture requirements. By framing. 08/31/2007 11:00 AM RH PDA Make sure that utility room has proper combustion air by building final. Door was missing. 08/30/2007 11:35 AM OC PDA gas test failed Page 1 b WF0889148 / 001 City of College Station PAGE 1 REQ. DATE: 04/16/07 04/16/07 16:27:04 LOCATION: 3817 NIGHT RAIN DR LOC ID: 200088 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/16/07 SCHED COMPLETION: 04/16/07 ******************************************************************************** JOB ORDER RESULT COM4ENTS From:STYLECRAFT BUILDERS INC 979 690 0348 09/21/2007 10:09 #172 P.002/004 �— `O Sep 20 07 08:38a Paul Williams Land Survey 9797797672 p-2 U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE I OMB No. 16611-0008 Federal Emergency Management Agency �RBs February 28. 2009 National Flood Insurance Program Important Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION Al. Building Owner's Name Stephen R. and Melissa Senkel A2. Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.ornpamy'NA1C 3817 Night Rain Drive City State 71P r`.rvie - - - - rroperry Description (Lot and Block Numbers, Tax P The Enclave at Westfield. Lot 30, Block 14. Phase 6 77840 A4- Building Use (e g., Residential, Non -Residential, Addition. Accessory, efca Residence A5_ LatitudeJLongbude: Lest N 30233'56.9(r Lang. W 96"1727.se horizontal Datum: ❑ NAD 1927 NAD 19M A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1, A8. For a building with a crawl space or endosure(s), provide: A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosures) sgit a) Square footage of attached garage s ft a b) No. of permanent flood openings in the awf space or b) No. of permanent flood openings in the attached q ge enclosure(s) walls within 1 Afoot above adjacent grade walls within 1.0 foot above adjacent grade 9 c) Total net area of flood openings in Aa-b sq in C) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE NAP (FIRM) INFORMATION 81. NFIP Community Name & Community Number EM County Name B3. State Col( a Station 480083 Brazos Texas B4. Map/Panel Number 85. Suffix . B6. FIRM Index B7. FIRM Panel ea. Flood B9. Base Flood F_levation(s} (Zone Dam Effec:tive/Revised Date Zones) AO, use base flood depth) 48041 CD182 & 201 C S D 7-2-92 2-9-2000 AE 292.3 B10. Indicate the sources of the Base Rood Elevation (BFE) data or base flood depth entered in item 89. [] PIS Profile FIRM ❑ Community Determined ❑ Other (Describe) Also See Subdivision Plat Westfield, Phase 6 1D71- Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 0 NAVD 1980 ❑ Other (4escrihe) BIZ Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)7 Yes No Designation Date ❑ CBRS ❑ OPA ❑ SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction- "A Finished Construction new Elevation Certificate will be required wirer construction of the building is complete C2 Elevations —Zones Al-A30, AE, AH, A (with BFq, VE, V1-V30, V (with BFE), AR, AR/A, ARfAE, AR/A1-A30, AR(AH, AWAO. Complete ItemS C2a-g below according to the building diagram specified in item A7. Benchmark Utilized CS 132 (City of College Station) Vertical Datum NAD 88 Conversion/Comments Subdivision BM pity requires 3 feet above BFE Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor) 297.97 , feet ❑ meters (Puerto Rico only) b) Top of the next higher floor feet �❑ ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) feet ❑ reefers (Puerto Rico only) d) Attached garage (top of slab) -,p feet ❑meters (Puerto Rico only) _e) Lamest elevation_dfmachineryorequipmentsenncsrglhebuilding - (D.escnbety�re��fn-Commerce}-- --------- ---- -- . _ ..------------------------------ — m - - - (Puerto Rico on �---- — - — -- - -- f) Lowest adjacent (finished) grade (LAG) 295-27feet ❑ meters (Puerto Rico only) g) Highest adjacent (finished) grade (HAG) _ 297.47 feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION r np cerumauon is m De signed and sealed by a land surveyor, engineer, or architect authorized by law to certify ele information. I certify that the in/omWWn on this Certificate represents mybest.elfor& to interpret the data available. f rvxWs:md Drat any false statement maybe punishable by fine or bnprismmmt wider 18 U a Code, Section loot ❑ Check -here if comments are -provided on back of form. License FEMA Form 81-31, February 20D6 See reverse Side for Continuation. Replaces all previous editions , From:STYLECRAFT BUILDERS INC 979 690 0348 09/21/2007 10:09 #172 P.003/004 Sep 20 07 08:38a Paul Williams Land Survey 9707707672 p.3 Building Photographs See Instructions for Item A6. korinslpatlC_eopan;use_==: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) ur P.O. Route and Box No. PoE 3817 t Rain Drive City - State ZIP Code-Q�iiparyi�tEUGNimher If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identity all photographs with: date taken; "Front View" and "Rear View"; and, if required, `Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. Floor Flevation High Elevation , From:STYLECRAFT BUILDER INC 979 690 0348 09/21/2007 10:10 #172 P.004/004 Sep 20 07 08:39a Paul Williams Land Survey 9797797672 p.4 Building Photographs Continuation Page Fo�:l is i`ance:= oiap jr:_ ), Building Street Address (including Apt., Unit, Suite, andlvr Bldg. No.) or P.O. Route and Box No. l�r Paticjrt>»riiber ;;:; :- 3817Rain Drive _ - : :......:::....,.. uty Cob a Station State ZIP Code Texas :::;.... :-..:.:.: . If submitting more photographs than will fit on the preceding page, affix the additional photographs below_ Identify all photographs with: date taken, "Front View" and "Rear View": and, if required, "Right Side View" and "Left Side View.' Low Elevation SHEET INDEX COVER SHEET G-1 SITE PLAN C-1 FLATWORK DETAILS C-2 FOUNDATION PLAN S-1 DIMENSION PLAN S-2 FRAMING PLAN S-3 ROOF FRAMING PLAN S-4 DECKING LAYOUT S-5 FRAMING DETAILS S-6 FLOOR PLAN A-1 DETAILS A-2 ELEVATIONS A-3 CABINET LAYOUT A-4 FLOORING PLAN A-5 ELECTRICAL PLAN E-1 3 817 NIGHT RAIN DRIVE THE ENCLAVE AT WESTFIELD LOT - 30 BLOCK - 14 PHASE - 6 FRONT ELEVATION SCALE: 3116*=11-0" 000000ao G-1 AREA SUMMARY p FINISHING NOTES LOT INCLUDES FULL FENCE & SOD CABINETS UPGRADE TO MAPLE/RUTLAND 3. SPRINKLER ALLOWANCE 4. 5. 6. 1 SITE PLAN SCALE: 1"=20'-0" a 1817 NIGHT RAIN DRIVE ME ENCLAVE AT WESTFIELD ,OT - 30 3LOCK - 14 'RASE - 6 SHEEP: C-1 AREA SUMMARY p (9/12/2007) Kim Wolfe - Re: Calling for C.O. for 3817 Night Rain Dr Page 1 From: Terry Boriskie To: Amber Carter; banderson@stylecraft-builders.com; Benjamin McCarty; Ch... Date: 9/12/2007 8:35 AM Subject: Re: Calling for C.O. for 3817 Night Rain Dr Stylecraft builders has been notified of the needed repairs. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 9/11/2007 12:23 pm >>> Water and sewer buried flagged. Paul >>> Amber Carter 9/11/2007 8:10 AM >>> by 07-1092 any issues? From:STYLECRAFT BUILDERS INC 979 690 0348 07/30/2007 15:21 #084 P.002/004 01-,ly Cv Jul 30 07 12:29p Paul Williams Land Survey 9797797672 p.2 U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No.1660-0008 Federal Emergency Management Agency I Etmires Febnrary 2& 2009 National Flood Insurance Program important Read the instructions on pages 1-8. SECTION A- PROPERTY INFORMATION iipriytle'`'' Al. Budding Owners Name ....... ': Stylecraft Builders A2. Building Street Address (including Apt, Unit, Suite, ancilor Bldg. No.) or P.O. Routs and Box No. Cbmpari- 'NAIC N' — ber• 3617 Night Rain Drive _Y - City State 23P Code College Station Texas 77040 A3. Property Description (Lot and Block Numbers. Tax Parcel Number, Legal Description, etc.) The Enclave at Westfield, Lot 30, Block 14, Phase 6 A4. Building Use (e.g., Residentlal, Non -Residential, Addition, Accessory, etc.) Residence AS. Latitude/Longitude: Lat N 30233'56.90' Long. W 96e17127.S2' Horizontal Datum: ❑ NAD 1927 0 NAD 1983 A& Attach at least 2 photographs of the building It the Ceri ficate is being used to obtain flood Insurance: A7. Building Diagram Number 1_ A& For a building with a crawl space or enclosure(s), provide: A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walk within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 61. NFlP Community Name &Community Number B2. County Name B3. State College Station 480083 Brazos Texas 64. Map/Panei Number M. Suffix B&. FIRM Index B7. FIRM Panel Ba-flood B9. Base Flood Elevation(s) (Zone Date Effective Revised Date 1 Zone(s) AO, use base flood depth) 48041 CO204 D 7-2-92 24-2000 AE 2923 1310. B11. B72- indicate the source of the Base Flood Elevation (SFE) data or base flood depth entered in Item B9. ❑ FIS Profile N FIRM [:]Community Determined ❑ Other (Describe) Indicate elevation datum used for BFE in Item 69. ❑ NGVD I W9 N NAVD 1988 ❑ Other (Describe) is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Designation Date [] CBRS ❑ OPA I] Yes E No SECTION C - BUILDING ELEVA71ON INFORMATION (SURVEY REQUIRED) Cl. 'Building elevations are based ow ❑ Const uctlon Drawings- N Building Under Construction` ❑ Finished Construction "A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations —Zones Al-A30, AE, AH, A (wi6m 8FE), VE, V1430, V (with BFE), AR, ARIA, AFVAE, ARIA1-A30, AR/AH, ARiAO. Complete Items C2.a-g below according to the budding diagram specified in Item A7. Benchmark Utilized CS 132 (City of College Station) vertical Rattan MAD 88 Conversion/Comments Subdivision BM city requires 3 feet above BFE Check the measurement used. a) Top of bottom floor (indudling basement, crawl space, or enclosure floor) W9 .97— �Et feet ❑ meters (Puerto Rico only) •b) Top of the next higher floor lJ feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal struchoal member (V Zones only) ^ ❑ feet ❑ meters (Puerto Rico only d) Attached garage (top of slab) _❑ feet ❑ meters (Puerto Rico only) e)-.. Lowest elevation of machinery or equipment -servicing the building .. - feet - - Q meters (Puerto Rico only) (Describe type of equipmend in Comments) f) Lowest adjacent (finished) grade (LAG) 29527-0 feet ❑ meters (Puerto Rico only) g) Highest adjacent (finished) grade (HAG) 297.47 feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certily that the information on this Certificate represents my best efforts to interpret the data available. 1 understand that any fake statement may be punishable by fare or imprisonment under 18 U.S. Code, Section 1001. = `,- ❑ Check here if comments are provided on back of form- Certifiers Name Licermp Numhp,r raw wnnams 5743 Title Company Name Surveyor Paul Williams Land Surveying Co Address City State ZIP Code Main Street, Ste. an Texas 77t30;i _ Si Date Telephone ~ �` 7-27-D7 7 9-7670 - FEMA Form 81-31, February 2006 See reverse side for continuation. Replaces all previous editions From:STYLECRAFT BUILDERS INC 979 690 0348 07/30/2007 15:22 #084 P.003/004 Jul 30 07 12:29p Paul Williams Land Survey 9797797672 Building Photographs See Instructions for Item A6. p.3 Building Street Address (including Apt. Unit, Suite, and/or Bldg. No.) or P_O_ Route and Box No. Policy Nwnb r 3917 Night Rain Drive City State ZIP Code eoniperlytVltt�t�h.: '. If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with. date taken; "Front View" and 'Rear View'; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. Floor Elevation High Elevation From:STYLECRAFT BUILDERS INC 979 690 0348 07/30/2007 15:22 #084 P.004/004 Jul 30 07 12:29p Paul Williams Land Survey 9797797672 p.4 Building Photographs Continuation Page Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. P.01!0�f Nam .........- 3817 Night Rain Drive .. City state ZIP Code If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View'., and, if required, 'Right Side View" and 'Loft Side View." Low Elevation BUILDING PERMIT CITY OF COLLEGE STATION 11 Jl T-ETAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001092 Date 4/16/07 Application pin number . . . 896684 Property Address . . . . . . 3817 NIGHT RAIN DR Property ID: 650730-0614-0300 R #: R118252 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 6 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 178002 Owner Contractor ------------------------ ------------------------ BCS DEVELOPMENT CO STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2697.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number 495168 Permit Fee 697.00 Plan Check Fee .00 Issue Date 4/16/07 Valuation . . . . 178002 Expiration Date 10/13/07 Qty Unit Charge Per Extension BASE FEE 460.00 79.00 3.0000 THOU BLDG, VAL 100001-500000 237.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT --------------------------- ------------------------ - --- ------------- BUILDING DEPT REPREr.NTA APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TE)tAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00001092 Date 4/16/07 Application pin number . . . 896684 --------------------------- 7------------------------------------------------ Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION "�J(----- --- --'-------- BUILDING DEPT REP �SEN?el-YE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00001092 Application pin number . . . 896684 Page 3 Date 4/16/07 Special Notes and Comments IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED ___ _ _ ✓I _ -=- - -------- BUILDING DEPT REPR NT APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 07-00001092 Date 4/16/07 Application pin number . . . 896684 ---------------------------------------------------------------------------- Special Notes and Comments FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC r ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. Minimum 292.3 Finished Floor. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited _Due ------------------------------ --------------- ----- --- ------------ BUILDING DEPT REPRES NTAT APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Permit Fee Total 697.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1447.00 07-00001092 896684 697.00 .00 750.00 1447.00 .00 .00 .00 .00 Page 5 Date 4/16/07 .00 .00 .00 .00 ---------------------------------L-- -- --- ---- --- BUILDING DEPT REPRE NTAT APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEnAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00001093 Date 4/16/07 Application pin number . . . 008311 Property Address . . . . . . 3817 NIGHT RAIN DR Property ID: 650730-0614-0300 R #: R118252 Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 6 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 495176 Permit Fee . . . . 20.00 Issue Date . . . . 4/16/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------- BUILDING DEPT REP$ APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CPrY OF COLLEGE STAITON (979) 764-3570 (979) 764.3496 FAX Pl= ng&Derebpmmt-%m!a WWW.CSTX.GOV ADDRESS/LOCATION: For 'ff Use Orr DATE V T C REG APPLICATION # TEMP POLE # LOT 30 LOCK 14- _�BDIVISION TkkE EtAQ-AA-- NT SEC/PH (P BUSINESS/OWNER NAME: STYLECRAFT BUIL©ERS, INC. PHONE: 690-1222 ext.120 CONTRACTORIHOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: r4l - _ TEXAS ACCESSIBILITY STANDARD (TASK PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ A "T 8 , 002 TOTAL AREA: 32-1.4 HEATED AREA: Zloq-7 (Co—st of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 3 BIZ 1�mSEWER TAP: N ® WATER TAP: OTHER TAP: (PWTEMP POLE GARAGE TYPE: Sim %° SIZE SIZE SINGLE INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: Sheet Rock Siding and/or Masonry Slab on Grade ROOF TYPE: Composition DOUBLE © TRIPLE ATTACHED XI DETACHED F--j CARPORT SIGNATURE OF APPLICANT: Lk, . C G For Stylecraft *If proposed work involves new commercial struction or facade improvements/renovations to an existing commercial property,, building elevations are required. 00o,a0ooe0e0o044000000.00o00000000000000000000000000000000000 (� Officlal Use Only Cp�ents: I <-2�r NO Plans Examiner4. Zoning OffiCI I - Mid • -F eZI'a .3 —is4-sut G464+je cA40 — L&N6 r6,t*o ►`J Energy Code Compliance Information % Glazing of exterior walls 8 s% Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 / R value of ductwork R6 VC SEER Rating 13,./ ,t PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: /7 AA I. Foundation Requirements- Minimum City Foundatitin Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NAIM A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck IWOK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements QKOK K A. Stairway Details NA(OK) 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NOKI 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAIM A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/Akj A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 860 NA/ft Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed VbK "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER �/ , -- a :7 DATE 5 • Permit # Permit Date REScheck Software Version 3.7.3 NOCompliance Certificate Project Title: Plan # 2697 EW Report Date: 04/12/07 Data filename: S:WCAD\Archived\Old REScheck\2697_EW_3817 Night Rain.rck Energy Code: 2000 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 18% Heating Degree Days: 1788 Construction Site: Permit Date: 04-12-2007 Owner/Agent: Designer/Contractor: Cornpiiance P,esses Maximum UA:,730 Your Home,UA: 684 > 6.3%'BetterAThan`Code (UA) Maximum SHGC: i•i i•i Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' Air Conditioner 2: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE 2448 30.0 0.0 86 280 19.0 0.0 15 2010 13.0 0.0 132 342 0.670 229 38 18 187 0.0 0.500 19 0.440 8 195 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. �.,,�, ST11.F�RAVJ SUtLD�R NC- - 2�7- Builder/D igner Company Name Date Project Notes: Previously saved project information: Senkel 3817 Night Rain Drive College Station, Texas Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Plan # 2697 EW Page 1 of 1