PREPARED 4/09/08, 12:00:28 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/09/08
------------------------------------------------------------------------------------------------
ADDRESS : 5215_BALLYBUNION_LN SUBDIV: PEBBLE CREEK
CONTRACTOR K M HAMILTON CONSTRUCTION, LP PHONE (979) 776-2300
OWNER . . PHONE
PARCEL . . 497900-0947-0180
APPL NUMBER: 07-00001081 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B100 01 6/07/07 OC
6/07/07 AP
B115 01 8/23/07 RH
8/23/07 AE
B130 01 8/27/07
JGM
8/27/07
AP
B125 01 4109/08
(tic-, 'as
ID ��
T
BLDG, FOUNDATION -SLAB TIME: 17:00
June 7, 2007 10:44:15 AM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
BLDG, FRAMING TIME: 17:00
August 22, 2007 4:41:32 PM glsouth.
08/23/2007 12:00 PM RH PDA
Need anchors at garage, fireblock fireplace chase. Need
joist hangers at entrance. Add support for cut wall studs
by insulation.
BLDG, INSULATION TIME: 17:00
August 27, 2007 11:01:51 AM glsouth.
BLDG, FINAL TIME: 17:00
April 9, 2008 8:14:07 AM acarter.
--,----------------------------------- COMMENTS AND NOTES--------------------------------------
�(�ii✓►'sPxtteC9 • gam
J
D`d 114� o
Date: 4/9/2008
Inspection Comments for Final
Permit Year: 7 'ermit Number: 1081
Address: 5215 BALLYBUNION LN
Type
inspection Type Code
Description
snsp.
Inspection Result Comments
B100
BLDG, FOUNDATION-SLi
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION-SLi
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
08/23/2007 12:00 PM RH PDA
13115
BLDG, FRAMING
IC
Need anchors at garage, fireblock fireplace chase. Need
B115
BLDG, FRAMING
IC
joist hangers at entrance. Add support for cut wall studs
B115
BLDG, FRAMING
IC
by insulation.
E150
ELEC, FINAL
IC
Install bath fans by bldg final.
M100
MECH, ROUGH IN
IC
August 6, 2007 2:08:37 PM acarter.
P115
PLBG, GAS LINE
IC
02/13/2008 10:14 AM RH PDA
P115
PLBG, GAS LINE
IC
Test on gauge in kitchen not holding min. 5 psi ading
P115
PLBG, GAS LINE
IC
under 3 psi. Gauge at meter okay.
P125
PLBG, FINAL
IC
wrong inspection.
Page 1
WF0902925 / 001 City of College Station
PAGE 1
REQ. DATE: 05/16/07 f 05/16/07 7:44:18
LOCATION: 5215 BALLYBUNION LN LOC ID: 205872
REQUESTOR: K M HAMILTON CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/16/07 SCHED COMPLETION: 05/16/07
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station-
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . . .
4/16/08
497900-0947-0180
5215 BALLYBUNION LN
COLLEGE STATION TX 77845
PEBBLE CREEK
PEBBLE CREEK 9-D
BLK 47
LOT 18
SINGLE FAMILY RESIDENTIAL
K M HAMILTON CONSTRUCTION, LP
979 776-2300
07-00001081 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Buiblinj Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
CEILING JOISTS MAX. SPAN
FLOOR JOISTS MAX. SPAN
RAFTER MAX. SPAN
HEADER SCHEDULE
UMTED ATTIC STORAGE
40 POP UK LOAD
ZA-M OVER 3/12
BEAM MAIL OP N
2 X a 0 leO.C. tr—r
2 X 12 0 12. O.C. 21'—r
2 X a 0 12' Or.1a'-1'
2-2 X 4 ON EDGE . d•-a•
2 X a 0 ta' O.OL 17'—S•
2 X 12 0 18' O.C. 1a'-10'
2 X a 0 18• O.C. 13'-11'
2-2 X a ON EDGE 4'—a'
2 X 10 0 10. O.C. 20'-0'
2 X 12 0 24' O.C. 13'-4•
2 X a 0 24' O.C. T1'-4'
2-2 X 8 ON EDGE a'—V
DO NOT El= aV01 OIL
DO NOT DO= WM OI1L
20 PEP LIVE LO.—I►! DEAD UL
2-2 X 10 ON EDGE 'r-a•
GENERAL
FRAMING NOTES
1. CUM JOOTS AND RAFTERS TO IS 2 X S 0 24. 0.0.
L 2 X 4 n= MALL BE DOMM 0 M DOES OF ALL
U TAM OTO]tOK MUM ON RAIL
WALL OPDMM IMED 0 ALL OMERS AND 7RIRED
• SF11SN0 COIDIIIAIS
2. RD0.OES 0 NP RAFTERS 10 BL 2 X 1
L PROMM SOdQE SOE PLATE AID DOOaE TOP PLATE
3 PROVO[ 2-2 X 4 STRONG JACK MDlAN 0
SPANS DVG tY-0' MTN 2 X 4 OMLAR TO 0
T. PROMOTE 1 X 4 DIAGONAL LET-11 MID ORACNO 0
4'-d CA
CORNSR7 Or DOOOCR WALI101t 1/r PLYMM
4, PROVCE 2 X 0 020M JOISTS 0 CA,IEORAL
L ALL STIMCRAAL PRAMOO TO K MO.2 MATERIAL MT1
LUAU
10 M.C. (MAX) AT TIME OF OOTALLATOL
STEEL ANGLE
LINTEL TABLE MIN. BEARING 4
BEAR
r-r at
r-r a
T-r 01 r-r at
r-r a
Ir-r OR
SPNO
UST
LESS
LESS tits
LESS
LESS
sm
3 l/r XXe/1E•
/2'
i,1r x B/tr
a 1 r z � z
/T B/1r S 1/2' % t/+r
s' x
S 1/Y % S/r
a• z
2 1/2• % 2/r
WINDER STAIRS
TREADS A MNMUM 0' ON
NARROW EDGE
TREAD MOTH 12' FROM
NARROW EDGE MN r
2 X 10 TREADS
2 X 12 STPoNGER
—2 X B 1REAQS/
1. CUT PURLIN BRACE BIRD MOUTH
TO FIT PURLIN ANGLE
2. PURLIN TO BE 0 RIGHT ANGLE TO RAFTER
3. DO NOT PRE -BUILD 'r BRACE,
INSTALL 2 X 4 BRACE FIRST, THEN
JAMB 2 X 4 AGAINST RAFTER & NAIL TO KNEE BRACE
i
MIN 2-16d /
GUARDRAIL NTERMEDIATE RAIL
0 SPAONG SMALL PREVENT
PASSAGE OF A 0' SPHERE
x 2 X 4-f3
2 X 6-#3 PURLIN
2-18d
2 X 4 KNEE BRACE
169 0—
TO RAISED BEAM
24 O.C.
2X4#3
—.. DortW nwrAO DAM
T/1r O! oEnlmto
151 PELT PAM
2 X 4 DODSLE TOP RATE
2��AAX 44��-SF SS AODNO
1MAOE0 TO tCO mu
Sow XLMM ODARSE--,
4/4• FOIL LUX SNLA MDR
FAO: am
2X 4STW 0ir O.C.
(1) 1/2' 0Q7110OIt
METAL WALL TQ 10 OCIRR OSK
METAL 0 24' 0.0 EVERY
BIN OOtIRSE (17Tj
UU70 2X4 SOT. PLATE
IM HOES 0 30' O.C.
2 x 12 Pt00R JOISTS
1 % 4 OOISCE TOP RAMC
(1) 1/r MssTRooc
C. (�� 2�/4•TITS %
M1Vta1STARA7101 WALLS
' w
m 1a• werimm
GATT IMIL ATXxt
1 X 4 311102 018" 04
PI oEoR
F6T PAPER
E TOP ME
p SICOOO
IAROM4/UIX
MOM
SHEAIMW
40
Emm,
• 1r o c
w
�.�t
J
++ }}
J�0_7t�S
A
I PLATE
FRAMM CUM O TEXT. MUY.L TYPR'& ow =" 90Cm
>X" 1/r . 11-0 1 WOMB 1/r . r-r
95.00'
BALLYBUNION COURT
SITE PLAN
SCALE: 1 "=20'-0"
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,,TX 77840
PHONE: (979)764-3570'— FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00001081
Date 5/15/07
Application pin number . . . 691907
Property Address . .
. . . . 5215 BALLYBUNION LN
Property ID:
497900-0947-0180
R #:
R
Application type description RESIDENTIAL, 1 UNIT DETACHED
NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 218000
Owner
Contractor
------------------------
------------------------
K M HAMILTON CONSTRUCTION,
LP
3131 BRIARCREST
DR STE. 111
BRYAN
TX 77802
(979) 776-2300
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK VENEER
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2708.00
INTERIOR WALL TYPE
DRYWALL
NUMBER OF BATHROOMS
3.50
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
426.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
502609
Permit Fee . . . .
814.00 Plan Check Fee
.00
Issue Date . . . .
5/15/07 Valuation . .
. . 218000
Expiration Date . .
11/11/07
Qty Unit Charge
Per
Extension
BASE FEE
460.00
118.00 3.0000
THOU BLDG, VAL 100001-500000
354.00
----------------------------------------------------------------------------
Special Notes and Comments
Narrow Wall Bracing
Fully Sheathed with Simpson Panel
at
Master Bedroom Bav window
area.
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,,TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00001081
Application pin number . . . 691907
Page 2
Date 5/15/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
---------�-,-n--------------------------- -- -- ---------
BUILDING DEPT REPRES��a'.11'ATIVEA , '
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,,TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00001081 Date 5/15/07
Application pin number . . . 691907
----------------------------------------------------------------------------
Special Notes and Comments
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND -SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,,TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00001081 Date
5/15/07
Application pin number . . . 691907
----------------------------------------------------------------------------
Special Notes and Comments
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 814.00 814.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1564.00 1564.00 .00
.00
BUILDING DEPT REPRE TATI&
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,,TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00001080 Date 5/15/07
Application pin number . . .
598760
Property Address . . . . . .
5215 BALLYBUNION LN
Property ID:
497900-0947-0180
R #:
R
Application type description
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
K M HAMILTON CONSTRUCTION, LP
3131 BRIARCREST DR
STE. 111
BRYAN
TX 77802
(979) 776-2300
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc AC
Permit pin number 502617
Permit Fee . . . . 20.00
Issue Date . . . . 5/15/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
------------------
BUILDING D
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979).,.764-3570 (979) 764-3496 FAX +
CITY OF COLLEGE STATION WW!W.CSTX.GOV
Planning 0 D-Iopment Sermiter.
ADDRESSS/LOOCCATION: �7 2 6A1_Lj1 At4i0ki L -
LOT 0 BLOCK ` -/ SUBDIVISION R5W6 CRt�L1G L/
Fa OI
DATE:
f 1 1z
APPLICATION #
TEMP POLE # M (y 50
SEC/PH * 9 c>
BUSINES OWNER NAME: _FAKa MAIDDE�4 - PHONE: M7-1) - ;232 2
r---), P-0a HA14jG_r4LV1l
CONTRACTO HOMEOWNER: WA MMIL-tOl (bjlMtA6'rj'ojJ f I' PHONE: ('17 01-W'
CONTRACTOR ADDRESS: S 19> ( $(2M2CR z ST ()2l\JG 4- ( (( 1, P_�P-r IIJ I --rk , ?7?0,2-
ELECTRICIAN:
HVAC:
PLUMBER:
_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: '6(iYAt E �AMI'L�e OoMC — Nt5W I&4S"ML4c.-( o-J
PROPOSED USE: HOME:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD g( S) PROJECT REGISTRATION# EABPRJ
VALUATION: $ +,-(IF,000 TOTAL AREA: 3i7.2. HEATED AREA: e'Z7dS
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
OTHER TAP:
0971,
TEMP POLE
GARAGE TYPE:
/I
SIZE
� y4
SIZE
SIZE
0%
l vc
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE: Z Wl
EXTERIOR WALL TYPE:'(;,
FOUNDATION TYPE: (QLj 4 J
ROOF TYPE: �V�P . 05k?r-j6iLe_$
SINGLE DOUBLE ® TRIPLE
ATTACHED DETACHED a CARPORT
SIGNATURE OF APPLICANT: P(7l4ati(.E't asw - 41-
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
P Plans Examiner
Zoning Official
CgWents:
(S or NO
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flatiareas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
, ✓
Glazing SHGC O`�
Glazing U-Factor 0. -7
R value of ductwork /c-
AJC SEER Rating / 3
I
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 07- /OV/DATE:
4-/6-
BUILDING ADDRESS: sa I S _
I. Foundation Requirements- Minimum Ci Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier la out shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
CNPOK
Il. Framing:
Floor, Wall, Ceiling and Roof Requirements
NAAgft
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
K
OK
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow ed e
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
-JA44
PLANS EXAMINER
L-/G- n-?
DATE