HomeMy WebLinkAboutRES2006-01305, 06-13060
PREPARED 8/25/06, 7:18:53 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/24/06
------------------------------------------------------------------------------------------------
ADDRESS 319 ROBELMONT DR SUBDIV: EDELWEISS GARTENS PH 6
CONTRACTOR CHARLES THOMAS HOMES, INC. PHONE (979) 696-4384
OWNER EDELWEISS GARTEN VENTURE PHONE
PARCEL 244030-0612-0120
APPL NUMBER: 06-00001305 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/01/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
6/01/06 AP June 1, 2006 8:22:07 AM kwolfe
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 6/26/06 JGM BLDG, FRAMING TIME: 17:00
6/26/06 AE June 26, 2006 9:59:21 AM kwolfe
06/26/2006 02:56 PM JGM PDA
need to complete fireplace flue
B130 01 6/30/06 BH BLDG, INSULATION TIME: 17:00
6/30/06 AP June 30, 2006 2:04:15 PM kwolfe
*r June 30, 2006 2:04:30 PM kwolfe
B1/ 01 8/24 06 a I BLDG, FINAL TIME: 17:00
August 24, 2006 3:47:51 PM kwolfe
------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------yj I
-
Date: 8/25/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1305
Address: 319 ROBELMONT DR
Ins.Type
Inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/26/2006 02:56 PM JGM PDA
6115
BLDG, FRAMING
IC
need to complete fireplace flue
B130
BLDG, INSULATION
IC
June 30, 2006 2:04:30 PM kwolfe
Page 1
WF0766098 / 001 City of College Station PAGE 1
REQ. DATE: 05/02/06 C)6- 05/02/06 16:27:18
LOCATION: 319 ROBELMONT DR LOC ID: 201844
REQUESTOR: CHARLES THOMAS HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/02/06 SCHED COMPLETION: 05/02/06
********************************************************************************
JOB ORDER RESULT COMIENTS
WF0763572 /
001 City of College Station
PAGE 1
REQ. DATE:
04/26/06
04/26/06
13:58:47
LOCATION:
319 ROBELMONT DR
LOC ID:
201844
REQUESTOR:
CHARLES THOMAS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/411
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/26/06 SCHED COMPLETION:
04/26/06
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY OF COLLEGE,STATION
1101 TEXAS n110
COLLEGE STAI.QI 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00001305 Date 4/26/06
Property Address . . . . . . 319 ROBELMONT DR
Property ID 244030-0612-0120
R $# R301745
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 6
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 110000
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
CHARLES THOMAS HOMES, INC.
311 CECILIA LOOP
CHARLES THOMAS
COLLEGE STATION
TX 778456310 P O BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1621.00
INTERIOR WALL TYPE
SHEET ROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
490.00 Plan Check Fee
.00
Issue Date . . . .
4/26/06 Valuation . .
. . 110000
Expiration Date . .
10/23/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
10.00 3.0000
THOU BLDG, VAL 100001-500000
30.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE'
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001305
Page 2
Date 4/26/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
--------------------------------------- -IV ---1-----------
BUILDING DEPT REPR'FENTATIVE: - ---
APPLICANT: \_ X . 1 U. --✓
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE4
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00.001305
Page 3
Date 4/26/06
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical)
BUILDING DE
APPLICANT:
DOORS IN
SHALL BE
HEATING
WORK MUST
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number
. . . . .
06-00001305
Date
4/26/06
----------------------------------------------------------------------------
Special Notes and Comments
BE PERFORMED BY
LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR
INSPECTIONS
PRIOR TO COVERING
ANY WORK
Narrow wall bracing Fully Sheathed
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
490.00
490.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1240.00
1240.00
.00
.00
-----------------
BUILDING
APPLICANT
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE'
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-00001306 Date
4/26/06
Property Address
. . . . . .
319 ROBELMONT DR
Property ID
244030-0612-0120
R #
R301745
Application type
description
TEMP POLE
Subdivision Name
. . . . . .
EDELWEISS GARTENS PH 6
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
EDELWEISS GARTEN
VENTURE
------------------------
CHARLES THOMAS HOMES,
INC.
311 CECILIA LOOP
CHARLES THOMAS
COLLEGE STATION
TX 778456310
P O BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/26/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
For Office Use Only
APPLICATION FOR BUILDING PERMIT
I
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 ,
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.
Planning & Devekpment Services f ^ ) I
ADDRESS/L✓OCATION: i r, 0 N rnD�. + <,U?,
MF
LOT " BLOCK UBDIVISION f �F�slSS 1ofc��
BUSINESS/OWNER NAME:
DATE:
APPLICATION # tit
TEMP POLE # 06 l C
PHONE:
CONTRACTOR/HOMEOWNER: CHARLES THOMAS HOMES, INC. PHONE: -2Z9- Oylpq--
CONTRACTOR ADDRESS: COLLEGE STATION, TX 77842
JO� eVXF_
ELECTRICIAN: iCTitC,— K��' PLUMBER: i �
HVAC: /P.i t,J GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION 41KOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) AlREM�DEL/RENOVATION* SWIMMING POOL
1 TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOCIATIQN�CHITECTUAL O
� �5 ;
TEXAS ACCESSIBILITY STANDARD (>FROJE
d-Q Q — VALUATION: $ I I
(Cost of L or and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
��jD — fl
SEWER TAP:
W `� b ATER TAP:
3 ZE
')
SI E
OTHER TAP:
SIZE
WTEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
DESIGN REVIEW COMMITTEE APPROVAL:
T REGISTRATION# EABPRJ
TOTAL AREA:=9�HEATED AREA:
11 441
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE TRIPLE
DETACHED Ej gARPORT
SIGNATURE OF APPLICANT: C_ •
*If proposed work involves new commercial const or a de improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
z6--oG
Plans Examiner
% dat
A
zr'
Zoning Official
C ents:
ES NO
Fire Marshall
Energy Code Compliance Informgtion
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
3076, -11�
I
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW/PERMIT NUMBER#
06 _ j 3 O
DATE: / -2G/ o
BUILDING ADDRESS:
o6,e,
2.
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30")
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d' Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N K
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
rWJ40K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
N K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning cr Development Services
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N K
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N O
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NA(OK)
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
A/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
K
Does not -block any water course or divert any flow
Elevation certificate if required
OA /�
(*f/""
CITY OF COLLEGE STATION
Planning er Development Services
Comments:
41", 1, 1 -
ANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
fpO.00
r—
�db�j���
CHARLES THOMAS HOMES, INC.'
P-O. BOX 10106
COLLEGE STATION, TX 77842
a
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: College Station Building Permits
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/23/06
DATE OF PLANS: 04/24/2006
PROJECT INFORMATION:
319 Roblemont - Edelweiss Gartens - Ph 6
COMPANY INFORMATION:
Charles Thomas Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 754
Your Home = 528
30.0% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
Door 1: Solid
Door 3: Solid
Door 2: Glass
Slab 1: Unheated, 0.0' insul.
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 14 SEER
Permit Number
Checked By/Date
Gross
Glazing
Area or Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
1621 0.0
32.0
47
1755 15.0
0.0
116
197
0.640
126
20
0.013
0
17
0.013
0
17
0.440
7
223
0.0
232
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submi ed with the permit application. The proposed building has
been designed to m the 000 IECC requiremen i Ccheck Version 3.2 Release 1 .
Builder/Designer `--�" Date 'T' 7- Z.Do (p