HomeMy WebLinkAboutRES2006-01288OPendatior
aEsselre
R 752113 10%'$P4
WF0763708 /
001 City of College Station
PAGE 1
REQ. DATE:
04/26/06
04/26/06
16:34:25
LOCATION:
929 CRYSTAL DOVE AVE ate' ry
LOC ID:
203260
REQUESTOR:
BRANDON BERRY -=_ ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/411
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/26/06 SCHED COMPLETION:
04/26/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0851445 / 001 City of College Station PAGE 1
REQ. DATE:
11/21/06
11/21/06
16:16:17
LOCATION:
927 CRYSTAL DOVE AVE
LOC ID:
203258
REQUESTOR:
BRANDON BERRY CONSTION
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
11/21/06 SCHED
COMPLETION:
11/21/06
********************************************************************************
JOB ORDER RESULT COMMENTS
y
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
7/13/06
005401-0104-0270
929 CRYSTAL DOVE AVE
COLLEGE STATION TX 77845
DOVE CROSSING
SINGLE FAMILY RESIDENTIAL
BRANDON BERRY CONST.
979 690-8670
Application number 06-00001288 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
A/� ///It
Approved . . . . . . .
B&lding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED
7/13/06,
8:00:22
INSPECTION TICKET PAGE 7
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 7/13/06
ADDRESS
929 CRYSTAL
DOVE AVE SUBDIV: DOVE CROSSING
CONTRACTOR BRANDON
BERRY CONST. PHONE (979) 690-8670
OWNER .
.
PHONE
PARCEL .
. 005401-0104-0270
APPL NUMBER: 06-00001288
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/15/06
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
5/15/06
AP
T/S: 05/15/2006 01:56 PM GLSOUTH -----------------------
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/01/06
JGM
BLDG, FRAMING TIME: 17:00
6/01/06
DP
May 30, 2006 4:45:38 PM bkorthauer
06/01/2006 10:42 AM JGM PDA
missing a.b. nuts throughout house and at simpson panels,
need to add anchors within 12" of ends of sole plates
including splices
Need joist hanger in kitchen
B115 02
6/05/06
JGM
BLDG, FRAMING TIME: 17:00
6/05/06
AP
June 5, 2006 10:17:06 AM kwolfe
MID AFTERNOON
B130 01
6/06/06
OC
BLDG, INSULATION TIME: 13:00
6/06/06
AP
June 6, 2006 9:58:40 AM llindgren
B125 01
7 13/06
BI
BLDG, FINAL TIME: 17:00
July 12, 2006 8:53:17 AM kwolfe
---------------------------------
COMMENTS AND NOTES --------------------------------------
Date: 7/13/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1288
Address: 929 CRYSTAL DOVE AVE
Type
Inspection Type Code
Description
St tus
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/01/2006 10:42 AM JGM PDA
B115
BLDG, FRAMING
IC
missing a.b. nuts throughout house and at Simpson panels,
B115
BLDG, FRAMING
IC
need to add anchors within 12" of ends of sole plates
B115
BLDG, FRAMING
IC
including splices
B115
BLDG, FRAMING
IC
Need joist hanger in kitchen
Ell
ELEC, ROUGH IN
IC
05/30/2006 04:02 PM JGM PDA
E110
ELEC, ROUGH IN
IC
block homerun, redo boxes at bathtubs
Page 1
BUILDING PERMIT
CITY OF COLLEGE,,STATION
1101 TEE
COLLEGE STATION,'TX77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 06-00001288 Date 4/26/06
Property Address . .
. . . . 92.9 CRYSTAL DOVE AVE
Property ID
. . 005401-0104-0270
R # . . . . . . . . .
. . . . R13907
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . DOVE CROSSING
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 107712
Owner
Contractor
------------------------
------------------------
BRANDON BERRY CONST.
3330 TRIPLE BEND CIR
COLLEGE STATION TX 77845
(979) 690-8670
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1632.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
484.00 Plan Check Fee .00
Issue Date . . . .
4/26/06 Valuation . . . . 107712
Expiration Date . .
10/23/06
Qty Unit Charge
Per Extension
BASE FEE 460.00
8.00 3.0000
THOU BLDG, VAL 100001-500000 24.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH -FRAMED SIZE
BUILDING DEPT REPRESENTATIVE:,_L
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE §TATION
1101 TEXOAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00001288 Date 4/26/06
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
--------------------------- ------ ----- - ----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE ,STATION
1101 TEAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 06-00001288 Date 4/26/06
----------------------------------------------------------------------------
Special Notes and Comments
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow wall bracing Fully Sheathed with Simpson Panels at
each side of garage entry.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
---------------------------------------------------- ---------------
BUILDING DEPTT REPRESENTATIVE: - --- -
� �
APPLICANT: k / _2A_11
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number
. . . . .
06-00001288
Date 4/26/06
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee Total
484.00
484.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1234.00
1234.00
.00
.00
------------------------------- ------ -- - ----------
BUILDING DEPT REPRESENTATIVE:
In/'r
APPLICANT:
OF
I (*41q"
CITY OF COLLEGE STATION
Planning d De-lopmentServicei
ADDRESS/LOCATION
LOT _BLOCK _
APPLICATION FOR BUltDING'PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
BUSINESS/OWNER NAME
9 al7 C
�ov
Fr ORke Use Onty
DATE: � Imo+ ` "TRCC REG
APPLICATION AMP — ` 3
TEMP POLE #
` SUBDIVISION y .p C�aS$i 4 SEC/PH1'1�4-
r �
r aa.cl�e•1 erry �. Gns^� PHONE: V2 SS 4-1 T6
CONTRACTOR/HOMEOWNER: 5&*1 e-
PHONE:
CONTRACTOR ADDRESS: 3 3 Y a r -p tc 7j�;ea C' e s-lc_
ELECTRICIAN:PLUMBER: lJJ-c �t�/mot m �j�In
HVAC: J L�`n now it 4i✓-c 9c?ry iLe S GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) )e NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: Sr •�c lc --�� .1a �i
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TA S) P ECT REGISTRATION# EABPRJ
VALUATION: $ , I I � 0� TOTAL AREAP2 46� HEATED AREA: 16 3 �
(Ct of L ba ro and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP: '�%
WATER TAP:
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE El
ATTACHED 91
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE
ROOF TYPE:
DOUBLE W1
DETACHED El
TRIPLE
CARPORT
3
r`3
COn ee/'�f/C-
4's h e !7
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade ' provements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
IX2s--DG
/ Plans Examiner
(lam
rS Li Q / `-
Zoning Official
tau Copmwnts:
NO
Fire Marshall
411
Energy Code Compliance Informafton '
% Glazing of exterior walls 2 °
Insulation R value of exterior walls 13 1--'
Insulation R value of ceiling 1 (flat areas) a
Insulation R value of ceiling 2 (vaulted areas/no attic). q /
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating (2—
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6-Development Services
PLAN REVIEW/PERMIT NUMBER# 0(0 ��
DATE: lavl ab
BUILDING ADDRESS: 9 ce,41row
Nue
-A&o
III
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
A'
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/Mg
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated on plans)
N OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2) feet higher than any portion of the building within ten 10 feet horizontal
l..
(*OF""
CITY OF COLLEGE STATION
Planning 6-Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
NAM
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
JK
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
Does not block any water course or divert any flow
Elevation certificate if re uired
A
:4
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning c5 Development Services
Comments:
Z E -a (o
PLANS EXAMINER DATE