HomeMy WebLinkAboutRES2006-01282, 06-128306-IJgC')-
06 -I Dg3
4Pendaflmr
/3Esselte
R 7521/3 100/oP4
,jr
Nicole Cochran Re: Calling Rockciiffe Loop 1
.....__ m_..
From: Terry Boriskie
To: Benjamin McCarty; Chris Haver; Gina Southerla;
Date: 10/5/2006 9:15:37 am
Subject: Re: Calling for CO @ 2127 Rockciiffe Loop Y:.
I have notified the builder Brandon Westerhiem and is will raise it.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 10/5/2006 9:01 am >>>
Water meter box is ok.
Sewer CO box needs to be raised to grade.
I put a green flag where box is buried.
PAUL S
>>> Nicole Cochran 10/5/2006 8:18 AM >>>
Are there any issues?
BP# 06-1282
Thank YouH
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.csbc.gov
Nicole Cochran - Re: Calling for CO @ 2127 Rockcliffe Loop 1
�.
From: Paul Schoenfeld
To: Benjamin McCarty; Chris Haver; Gina Southerla
Date: 10/5/2006 9:01:15 am
Subject: Re: Calling for CO @ 2127 Rockcliffe Loop
Water meter box is ok.
Sewer CO box needs to be raised to grade.
I put a green flag where box is buried.
PAUL S
>>> Nicole Cochran 10/5/2006 8:18 AM >>>
Are there any issues?
BP# 06-1282
Thank You!!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.gov
PREPARED 10/04/06, 12:01:26 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/04/06
------------------------------------------------------------------------------------------------
ADDRESS . : 2127 ROCKCLIFFE LOOP SUBDIV: CASTLEGATE SEC 2 PH 2
CONTRACTOR WESTERHEIM CUSTOM HOMES PHONE (979) 680-1655
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-2202-0140
APPL NUMBER: 06-00001282 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/03/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/03/06 AP May 3, 2006 10:39:27 AM bkorthauer
B115 01 7/05/06 OC BLDG, FRAMING TIME: 17:00
7/05/06 AP July 5, 2006 10:57:45 AM malford
B130 01 7/10/06 JGM BLDG, INSULATION TIME: 17:00
7/10/06 AP July 10, 2006 10:57:49 AM bkorthauer
B125 01 10/04/ 6 BI BLDG, FINAL TIME: 17:00
October 4, 2006 10:51:27 AM kwolfe
--='--------
�---------- COMMENTS AND NOTES ------- ----------------------------
Nc-e atr � tic(
Date: 10/5/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1282
Address: 2127 ROCKCLIFFE LOOP
Type
Inspection Type Code
status
Inspection Result Comments
Description
P125
PLBG, FINAL
IC
10/04/2006 11:33 AM JGM PDA
P125
PLBG, FINAL
IC
flue pipe for water heater extends too far laterally
Page 1
WF0776282 / 001 City of College Station
PAGE 1
REQ. DATE:
05/19/06
y
05/19/06
10:38:39
LOCATION:
2127 ROCKCLIFFE LOOP
LOC ID:
194958
REQUESTOR:
WESTERHEIM CUSTOM HOMES
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
05/19/06 SCHED
COMPLETION:
05/19/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0763831 / 001 City of College Station
PAGE 1
REQ. DATE:
04/27/06
04/27/06
8:45:40
LOCATION:
2127 ROCKCLIFFE LOOP
LOC ID:
194958
REQUESTOR:
WESTERHEIM CUSTOM HOMES
ORIGIN: CUSTOMER -WALK IN
REQ. USER:
BKORTHAUER AUTH. USER:
BKORTHAUER WORK TYPE:
ROUT
4" SEWER
TAP AND 3/4" WATER TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET READY
SCHED START:
04/27/06 SCHED
COMPLETION:
04/27/06
********************************************************************************
JOB ORDER RESULT CONVIENTS
City..of. College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
Owner . . . . . . . . .
12/15/06
184200-2202-0140
2127 ROCKCLIFFE LOOP
COLLEGE STATION TX 77845
CASTLEGATE SEC 2 PH 2
CASTLEGATE SEC 2, PHS 2, BLOCK
2, LOT 14
PLANNED DEVL HOUSING
GREENS PRAIRIE INVESTORS LTD
Contractor . . . . . . WESTERHEIM CUSTOM HOMES
979 680-1655
Application number 06-00001282 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
. . . . . . . jt4ftl
Buil ing Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning &Development Services
PLAN REVIEW/PERMIT NUMBER#
(�
DATE: L/ /zs-/oG
BUILDING ADDRESS: 2(z-j
L'o-o
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings (30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
ll. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/ K
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing lan,or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6- Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
N�
III. Stairway Requirements
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
N K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
(*f/q"
CITY OF COLLEGE STATION
Planning c4 Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
NA/ K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
MA10K
Does not block any water course or divert any flow
Elevation certificate if required
PLAN REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Planning d Development Services
Comments:
A& 4-L 7,5-- oG
PLANS EXAMINER DATE
RFScheck Compliance Certificate
2000 IECC
REScheck Solware Version 3.6 Release la
Data filename: C:\Program Files\Check\REScheck\2127 Rockclile.rck
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.17
DATE: 04/24/06
DATE OF PLANS: 04-2006
PROJECT DESCRIPTION:
2127 Rockclife
DESIGNER/CONTRACTOR:
Westerheim Custom Homes
COMPLIANCE: Passes
Maximum UA = 1100
Your Home UA = 840
23.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.38
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.38
Door 1: Glass
SHGC: 0.38
Door 2: Glass
SHGC: 0.38
Door 3: Glass
SHGC: 0.38
Door 4: Solid
Floor 1: Slab-On-Grade:Unheated
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
Furnace 1: Forced Hot Air, 78 AFUE
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity Cont.
or Door
Perimet
R-Value R-Value
U-Factor
2557
30.0 0.0
89
2832
13.0 3.6
162
364
0.640
233
43
0.310
13
43
0.310
13
19
0.310
6
19
0.150
3
308
0.0
321
Boiler 1: Gas -Fired Steam, 75 AFUE
Boiler 2: Gas -Fired Steam, 75 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in REScheck Version 3.6 Release I (formerly MECcheck) and to comply with the
mandatory requirements)$ted ilgthe jIEScheck Inspection Checklist.
Builder/Designer 1 A&2= Date' ZZ "0lo
2� 6y
I
I
I
I
I
I
t
`
I
I
�
`
I
I
�
I
I
�
I
I
I
�
25' SETBACK\`��
I
I
I
,
I
I
I
,
,
I
Lu
I
V
I
i
c
I
cn W
I
m
-°Q
I
D
I
I
I
77
'' '
�•:;� :.' :•y =::.• ; y .
25' SETBACK
WESTERHEIM CUSTOM
HOMES Aq.
2127 ROCKCLIFFE
LOT 14 BLOCK 2
CASTLEGATE SECTION 2
PH 2
SCALE : 1* = 20'
BUILDING PERMIT
CITY OF COLLEGE STATION
110 L.r kS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00001282 Date 4/26/06
Property Address . . . . . . 2127 ROCKCLIFFE LOOP
Property ID: 184200-2202-0140
R #: R112649
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE SEC 2 PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 170148
Owner Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD WESTERHEIM CUSTOM HOMES
4490 CASTLEGATE DR 3800 SH 6 S 108
COLLEGE STATION TX 778453388 COLLEGE STATION TX 77845
(979) 680-1655
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2578.00
INTERIOR WALL TYPE SHEET ROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 441.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc BK
Permit Fee . . . . 673.00 Plan Check Fee .00
Issue Date . . . . 4/26/06 Valuation . . . . 170148
Expiration Date . . 10/23/06
Qty Unit Charge Per Extension
BASE FEE 460.00
71.00 3.0000 THOU BLDG, VAL 100001-500000 213.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S)-
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
------------------------------------------ -----IV•-- ---•--'-------------
BUILDING DEPT REPI4SE17A7V
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
110,1 ,TEX,AS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001282
Page 2
Date 4/26/06
Special Notes and Comments
X.3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
-------------------------------------------;----- -- or- - - rff-----Ar -t------ - - - - --
BUILDING DEPT RE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
110.1 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001282
Page 3
Date 4/26/06
Special Notes and Comments
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36"
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 20031IMC
BUILDING DE
APPLICANT:
ray �
BUILDING PERMIT
CITY OF COLLEGE STATION
110.1 TEYjAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . .
06-00001282
Date
4/26/06
----------------------------------------------------------------------------
Special Notes and Comments
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical)
WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING
ANY WORK
Be aware of 30' rear PUE
No work to be done on Bonus Room without proper
permit.
Narrow wall bracing Fully Sheathed with Interior Anchors
and 32" Alternate Braced Panel.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 673.00
673.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1423.00
1423.00
.00
.00
----------------------------------------------------------------
BUILDING DEPT REP%F�6EIAT /*:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
110.1 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-00001283
Date 4/26/06
Property Address . . . . . .
2127 ROCKCLIFFE LOOP
Property ID:
184200-2202-0140
R #:
R112649
Application type description
TEMP POLE
Subdivision Name . . . . . .
CASTLEGATE SEC 2 PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
PLANNED DEVL HOUSING
Application valuation . . . .
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
WESTERHEIM CUSTOM
HOMES
4490 CASTLEGATE DR
3800 SH 6 S 108
COLLEGE STATION TX 778453388
COLLEGE STATION
TX 77845
(979) 680-1655
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc BK
Permit Fee . . . . 20.00
Issue Date . . . . 4/26/06
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
--------------------
Due
----------
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
----------------------------------------------IV•----I-
-----------
BUILDING DEPT REPR EN T
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Development Services
WWW.CSTX.GOV
ADDRESS/LOCATION: 2127 ROCKCLIFFE LOOP
LOT -14 /BLOCK 21-�' SUBDIVISION CASTLEGATE SEC 2-2
SEC/PH
For OfSoe U" Only
DATE: 4�O'q Wj REG
APPLICATION # O� ^Vv
TEMP POLE # " ( 1��>
I BUSINESS/OWNER NAME: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163
I CONTRACTOR/HOMEOWNER: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163
I CONTRACTOR ADDRESS: 3800 HWY 6 STE 108B COLLEGE STATION TX 77845
I ELECTRICIAN: HILCO
PLUMBER: JB PLUMBING
HVAC: SEIGERT GOOD CENTS (Residential only): YES
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NEW HOME
STRUCTURE USE: SINGLE FAMILY DWELLING
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAB PROJECT REGISTRATION# EABPRJ
VALUATION: $ 110 1 iAZ � TOTAL AREA:3477 HEATED AREA:2578
(Cost of Labor and Materials)
FX PUBLIC SEWER NUMBER OF BEDROOMS: 4
I SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 3
SEWER TAP:
WATER TAP:
I OTHER TAP:
®X TEMP POLE
GARAGE TYPE:
4"
SIZE
3/4n
SIZE
SIZE
SINGLE
ATTACHED
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE
ROOF TYPE:
DOUBLE TRIPLE
IETA�,HED CARPORT
SHEETROCK
BRICK/STONE
SLAB ON GRADE
COMP SHINGLES
SIGNATURE OF APPLICANT: / o
*If proposed work involves new commercial construct) or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
s:
nt
?�� ` � 6 YE or O
;47-f
.�c 31s U� _ ✓� sty, 3 ;�4dm �tiRa 1 s�
le
0oa%6 hoftr IN611C qj I�
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
13.0
Insulation R value of exterior walls
13.0
Insulation R value of ceiling 1 (flat areas)
30
Insulation R value of ceiling 2 (vaulted areas/no attic)
19
Glazing SHGC
0.39
Glazing U-Factor
0.64
R value of ductwork
6
A/C SEER Rating
14