Loading...
HomeMy WebLinkAboutRES2006-01280, 06-1281PREPARED 5/08/07, 12:02:01 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/08/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 4752 JOHNSON CREEK LOOP SUBDIV: WILLIAMS CREEK PH 2 CONTRACTOR WESTERHEIM CUSTOM HOMES PHONE (979) 680-1655 OWNER . . PHONE PARCEL . . 660050-0203-0220 APPL NUMBER: 06-00001280 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/02/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 6/02/06 AP June 2, 2006 11:11:00 AM kwolfe Slab Ground Installed Form Survey Submitted B115 01 9/18/06 OC BLDG, FRAMING TIME: 17:00 -9/18/06 AE September 7, 2006 11:59:38 AM kwolfe 09/18/2006 04:21 PM OC PDA check for slab ground . B13'0 01 9/21/06 JGM BLDG, INSULATION TIME: 17:00 9/21/06 AP September 20, 2006 1:04:38 PM glsouth 13125 01 5/04/07 JGM BLDG, FINAL TIME: 17:00 5/04/07 DP May 3, 2007 1:39:44 PM ncochran. 05/04/2007 11:47 AM JGM PDA need attic insulation B125 02 /08 07 BLDG, FINAL TIME: 17:00 OSs& May 8, 2007 9:25:39 AM glsouth. ------------------------L`�{----------- COMMENTS AND NOTES---------------------------------r�,�-- o \v, Date: 5/8/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 1280 Address: 4752 JOHNSON CREEK LOOP Type Inspection Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B100 BLDG, FOUNDATION -SLAB IC Form Survey Submitted B115 BLDG, FRAMING IC 09/18/2006 04:21 PM OC PDA B115 BLDG, FRAMING IC check for slab ground . B125 BLDG, FINAL IC 05/04/2007 11:47 AM JGM PDA B125 BLDG, FINAL IC need attic insulation E110 ELEC, ROUGH IN IC 09/08/2006 03:11 PM JGM PDA Ell ELEC, ROUGH IN IC need slab ground E150 ELEC, FINAL IC September 11, 2006 4:37:26 PM ncochran E150 ELEC, FINAL IC 02/08/2007 03:20 PM RH PDA E150 ELEC, FINAL IC light fixtures missing in bathroom. soffit, smoke detector E150 ELEC, FINAL IC missing P125 PLBG, FINAL IC 05/04/2007 11:50 AM JGM PDA P125 PLBG, FINAL IC need vacuum breaker on outside hosebib, need to P125 PLBG, FINAL IC vent pipe behind water heater Page 1 (5/11/2007) Gina Southerland Re Calling for CO @ 4752 Johnson Creek Loop From: Paul Schoenfeld To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol... Date: 5/4/2007 8:18 AM Subject: Re: Calling for CO @ 4752 Johnson Creek Loop ALL OK. PAUL >>> Nicole Cochran 5/4/2007 8:15 AM >>> Issues? BP# 06-1280 Thanks! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov Date: 5/4/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 1280 Address: 4752 JOHNSON CREEK LOOP Type Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B100 BLDG, FOUNDATION -SLAB IC Form Survey Submitted B115 BLDG, FRAMING IC 09/18/2006 04:21 PM OC PDA B115 BLDG, FRAMING IC check for slab ground . E110 ELEC, ROUGH IN IC 09/08/2006 03:11 PM JGM PDA E110 ELEC, ROUGH IN IC need slab ground E150 ELEC, FINAL IC September 11, 2006 4:37:26 PM ncochran E150 ELEC, FINAL IC 02/08/2007 03:20 PM RH PDA E150 ELEC, FINAL IC light fixtures missing in bathroom. soffit, smoke detector E150 ELEC, FINAL IC missing Page 1 City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . Owner . . . . . . Contractor . . . 5/25/07 660050-0203-0220 4752 JOHNSON CREEK LOOP COLLEGE STATION TX 77845 WILLIAMS CREEK PH 2 WILLIAMS CREEK 42, BLOCK 3, LO T 22, ACRES 1.085 RURAL RESIDENTIAL SUB. . WESTERHEIM, BRANDON S DBA Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . WESTERHEIM CUSTOM HOMES 979 680-1655 06-00001280 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Buioding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL (5%25/2007) Gina Southerland Re: Calling for CO "@ 4752 Johnson Creek Loo Page 1 From: Paul Schoenfeld To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol... Date: 5/4/2007 8:18 AM Subject: Re: Calling for CO @ 4752 Johnson Creek Loop ALL OK. PAUL >>> Nicole Cochran 5/4/2007 8:15 AM >>> Issues? BP# 06-1280 Thanks! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov JUN 02,2006 13:35 9796964164 Page 1 L1E-Lhc-cl91Jb 'lU"�_ I-YIf_IL. I•IIL.1.111197 LI{INi }I,INU� 'ii'`4"rr,'-r��, I'FI�:iL 1 1 112- Rod lot 6 Lot Non Rod f / RoFn i cvl � 1 � A' e+'2s ' Rod rnd. 1 1 ! r-- / 1 11 I f I q75Z JOHN5001 1 l car 22 q;r 1 I I �ati I " l,ol 21 Nlr&F- 1 — W' 1 vs 11 41218 I 1 1 1 I I r F,Vl �.. •� .� 1 4 �L � � L,y— I I I I y-5m.00' '^ 4-120.09' Rod rnd. j 112" Wn r'•-60..70' i%d phd lC 119,84' tR=s lac: ur` w i I (ea# and Actuvo I FORM SURVEY I 4752 Johnson Creek Loop Prepared For.• Westerheim Custom Homes OilYM Ula ( CaM�a SMaEMraJAaiw Cw•�b� T P?cYNlby EO Ib M&W NQ . rao f" M W RAW Ay+ Ib a/ l5.i 07Ia f' AUearW a/ Acv Lbwy. �wnn, A v~w &WW RI�p.✓ 1�4 AH! �. AayyMMM 0" Pw r dw rweU► uI o rPwp' Ms.J e� dw wwN{ ��aYr A' an .�n� J, j }Ot:K Jwe M eew wd awrnnf ti � 6wf of �• ba*Idlw II! 1 1/WOW Ovo* FROM M mi—i-eh an !YM �'JI' �'Ni..w,A w1 odfwM,t RaMO% w�. eb 0 M No YMs►h Aw w iw "t e..Aewn f7w 11gF fn WYlrl a fAva/ /Ao�rd d4'cM P�p� o Mwap.� Noi1 grq.wd y� .$a[wfl yye Ab, b0�/y�yyytQcc�b� laf�/ tibM�y C, A70Q j� , 69 i ley*,�..����r.�►• t' 1 � � er IcR PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning er Development Services PLAN REVIEW/PERMIT NUMBER# _ Z o DATE: �/ /L BUILDING ADDRESS: Ljgsa I. Foundation Requirements N K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/gW A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. N. Span exceeding code tables must be engineered Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N7 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes Al 4 III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N K A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements A/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required {� /" CITY OF COLLEGE STATION Planning cr Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS -Z LANS EXAMINER DATE WESTERHEIM CUSTOM HOMES 4752 JOHNSON CREEK LOT 22 BLOCK 3 WILLIAMS CREEK PHASE 3 SCALE : I' = 40' REScheck Compliance Certificate 2000 IECC REScheck Solware Version 3.6 Release la Data filename: C:\Program Files\Check\REScheck\4752 Johnson Creek.rck CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.17 DATE: 04/24/06 DATE OF PLANS: 04-2006 PROJECT DESCRIPTION: 4752 Johnson Creek Loop DESIGNER/CONTRACTOR: Westerheim Custom Homes COMPLIANCE: Passes Maximum UA = 1130 Your Home UA = 873 22.7% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.38 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.38 Door 1: Glass SHGC: 0.38 Door 2: Glass SHGC: 0.38 Door 3: Glass SHGC: 0.38 Door 4: Solid Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter -Value -Value U-Factor 2763 30.0 0.0 97 156 19.0 0.0 8 2887 13.0 3.6 164 387 0.640 248 43 0.310 13 43 0.310 13 19 0.310 6 19 0.150 3 308 0.0 321 i i Furnace 1: Forced Hot r, 7 AFUE Boiler 1: Gas -Fired St , 7i AFUE Boiler 2: Gas -Fired Steam, 7 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.6 Release la (formerly MECcheck) and to comply with the mandatory requiremerA listey#in * V}Scheck Inspection Checklist. TRANSMISSION VERIFICATION REPORT TIME 06/22/2006 16:34 NAME FAX TEL SER.# 000L5J596800 DATE,TIME 06/22 16:34 FAX NO./NAME 98215796 DURATION 00:00:41 PAGE(S) 01 RESULT OK MODE STANDARD ECM Appnestlon 06-00001: 119onds ® Contractor ea)crow IM Foos i ••� Global balance du ® miscellaneous Inrc ® kimRi ® Permits ® Plan tracking ® -Receipts ® square Footaoe ca Structures 'valuation calculate tlddxvss: 4752 ,7[DOa m Cm= Lop COOmm = *x=, mac 79045 l.ncatian ID 102192 Owner name; I'I OUHWM XWETMITS Me P"Pertl 7AF 6e13050=0203-0 20 R802317 Zcadim: i 1DII9 c'eal.ector IQamel 1w5'OOmmm C=Tw NOS= Contractor fiber: 15-00201)96 Two: Mum. cOm90i071SOR SCat". ]ICPNB contractor I.-Dob imMsr 1 p piicaribn status: CLOSED status Pate: 6122/2001 110.11cat10A type: TDB PMZ tioucation elate: a►Ta/zoos valvatioa: a SQms i;VOt ! O MUG hvildiA4: go OUMAnding inepe imp ScLeaale ConUrmatSoh Too ID Dot* FEWbaF ------------- ------ ---------- - -, go outetal" BUILDING PERMIT CITY OF COLLEGE STATION - 1101 TEXAS RVEr COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ------------------------------------------=--------------------------------- FAX: (979)764-3496 Application Number . . . . . 06-00001280 Date 4/26/06 Property Address . . . . . . 4752 JOHNSON CREEK LOOP, Property ID: 660050-0203-0220 R #: R**** Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WILLIAMS CREEK PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . RURAL RESIDENTIAL SUB. Application valuation . . . . 197142 Owner Contractor ------------------------ ------------------------ WESTERHEIM CUSTOM HOMES 3800 SH 6 S 108 COLLEGE STATION TX 77845 (979) 680-1655 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2987.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 329.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 754.00 Plan Check Fee .00 Issue Date . . . . 4/26/06 Valuation . . . . 197142 Expiration Date . . 10/23/06 Qty Unit Charge Per Extension BASE FEE 460.00 98.00 3.0000 THOU BLDG, VAL 100001-500000 294.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIM ROUGH -FRAMED SIZE 22" ------------------------------------------ ---- IV -- ---�-- -•------------- BUILDING DEPT R PRESENTATIVE:_ APPLICANT: 00&&A� BUILDING PERMIT CITY OF COLLEGE STATION , 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00001280 Date 4/26/06 ---------------------------------------------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR MORE INFORMATION. SEPTIC SYSTEMS INSTALLED PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK S DONE IN ORDER TO BUILDING DEP EPRESENTATIVE: �/�i (VA 1__11III A; APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00001280 Date 4/26/06 ---------------------------------------------------------------------------- Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Minimum Finished Floor 278' for sewer. Septic system. -------------------------------------- - - - --- ----- --- -- -- ------ - - - - -- BUILDING DEP� ]Ri P,fi RESE ff jVE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 06-00001280 Date 4/26/06 ---------------------------------------------------------------------------- Special Notes and Comments Must Meet all electrical requirements. Narrow wall bracing fully sheathed ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total Plan Check Total Grand Total 754.00 754.00 .00 .00 .00 .00 .00 .00 754.00 754.00 .00 .00 - TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE ' COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001281 Date 4/26/06 Property Address . . . . . . 4752 JOHNSON CREEK LOOP Property ID: 660050-0203-0220 R #: R**** Application type description TEMP POLE Subdivision Name . . . . . . WILLIAMS CREEK PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . RURAL RESIDENTIAL SUB. Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ WESTERHEIM CUSTOM HOMES 3800 SH 6 S 108 COLLEGE STATION TX 77845 (979) 680-1655 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc BK Permit Fee . . . . 20.00 Issue Date . . . . 4/26/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 20.00 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 --------------------------------------------- ------ --- ----- ----------- BUILDING DEPT ��ttEPRESENTfIVF}: 1/ OIIDnd--hI Il_ APPLICANT: IL f a APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning c4 Development Services WWW.CSTX.GOV ADDRESS/LOCATION: 4752 JOHNSON CREEK LOOP (� For Offl a Use Only DATE: '1Q RE - APPLICATION # (,�► (VV� TEMP POLE # r t7 LOT 22 ✓BLOCK SUBDIVISION WILLIAMS CREEK / SEC/PH 2 1---- BUSINESS/OWNER NAME: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163 CONTRACTOR/HOMEOWNER: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163 I CONTRACTOR ADDRESS: 3800 HWY 6 STE 108B COLLEGE STATION, TX 77845 ELECTRICIAN: HILCO PLUMBER: JB PLUMBING HVAC: SEIGERT GOOD CENTS (Residential only): YES CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: NEW HOME STRUCTURE USE: SINGLE FAMILY DWELLING HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARDR S) PROJECT REGISTRATION# EABPRJ VALUATION: $ 1aq i 1 y� I TOTAL AREA:4039 HEATED AREA:2987 (Cost of Labor and Materials) ❑ PUBLIC SEWER NUMBER OF BEDROOMS: 4 I �X SEPTIC/TREATMENT SYSTEM .SEWER TAP: WATER TAP: I OTHER TAP: I [jg TEMP POLE GARAGE TYPE: SIZE SIZE Ser a SINGLE ED ATTACHED M NUMBER OF BATHROOMS: 3 INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE 0 TRIPLE DETACHED F__] CARPORT SHEETROCK BRICK/STONE SLAB ON GRADE COMP SHINGLES SIGNATURE OF APPLICANT: *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only TeS q-zs -,a< Plans Examiner -.4At . FF a 7 6 4L ents: ES o NO ✓, Zoning Official - ram' AA 6(e(e 'c-A Energy Code Compliance Information % Glazing of exterior walls 13.0 e-- Insulation R value of exterior walls 13.0 e" Insulation R value of ceiling 1 (flat areas) 30 "-- Insulation R value of ceiling 2 (vaulted areas/no attic) 19 1---' Glazing SHGC 0.39 Glazing U-Factor 0.64 R value of ductwork 6 A/C SEER Rating 14