HomeMy WebLinkAboutRES2006-01280, 06-1281PREPARED 5/08/07, 12:02:01 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/08/07
------------------------------------------------------------------------------------------------
ADDRESS . : 4752 JOHNSON CREEK LOOP SUBDIV: WILLIAMS CREEK PH 2
CONTRACTOR WESTERHEIM CUSTOM HOMES PHONE (979) 680-1655
OWNER . . PHONE
PARCEL . . 660050-0203-0220
APPL NUMBER: 06-00001280 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/02/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
6/02/06 AP June 2, 2006 11:11:00 AM kwolfe
Slab Ground Installed
Form Survey Submitted
B115 01 9/18/06 OC BLDG, FRAMING TIME: 17:00
-9/18/06 AE September 7, 2006 11:59:38 AM kwolfe
09/18/2006 04:21 PM OC PDA
check for slab ground .
B13'0 01 9/21/06 JGM BLDG, INSULATION TIME: 17:00
9/21/06 AP September 20, 2006 1:04:38 PM glsouth
13125 01 5/04/07 JGM BLDG, FINAL TIME: 17:00
5/04/07 DP May 3, 2007 1:39:44 PM ncochran.
05/04/2007 11:47 AM JGM PDA
need attic insulation
B125 02 /08 07 BLDG, FINAL TIME: 17:00
OSs& May 8, 2007 9:25:39 AM glsouth.
------------------------L`�{----------- COMMENTS AND NOTES---------------------------------r�,�--
o \v,
Date: 5/8/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1280
Address: 4752 JOHNSON CREEK LOOP
Type
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B100
BLDG, FOUNDATION -SLAB
IC
Form Survey Submitted
B115
BLDG, FRAMING
IC
09/18/2006 04:21 PM OC PDA
B115
BLDG, FRAMING
IC
check for slab ground .
B125
BLDG, FINAL
IC
05/04/2007 11:47 AM JGM PDA
B125
BLDG, FINAL
IC
need attic insulation
E110
ELEC, ROUGH IN
IC
09/08/2006 03:11 PM JGM PDA
Ell
ELEC, ROUGH IN
IC
need slab ground
E150
ELEC, FINAL
IC
September 11, 2006 4:37:26 PM ncochran
E150
ELEC, FINAL
IC
02/08/2007 03:20 PM RH PDA
E150
ELEC, FINAL
IC
light fixtures missing in bathroom. soffit, smoke detector
E150
ELEC, FINAL
IC
missing
P125
PLBG, FINAL
IC
05/04/2007 11:50 AM JGM PDA
P125
PLBG, FINAL
IC
need vacuum breaker on outside hosebib, need to
P125
PLBG, FINAL
IC
vent pipe behind water heater
Page 1
(5/11/2007) Gina Southerland Re Calling for CO @ 4752 Johnson Creek Loop
From: Paul Schoenfeld
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 5/4/2007 8:18 AM
Subject: Re: Calling for CO @ 4752 Johnson Creek Loop
ALL OK.
PAUL
>>> Nicole Cochran 5/4/2007 8:15 AM >>>
Issues?
BP# 06-1280
Thanks!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.gov
Date: 5/4/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1280
Address: 4752 JOHNSON CREEK LOOP
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B100
BLDG, FOUNDATION -SLAB
IC
Form Survey Submitted
B115
BLDG, FRAMING
IC
09/18/2006 04:21 PM OC PDA
B115
BLDG, FRAMING
IC
check for slab ground .
E110
ELEC, ROUGH IN
IC
09/08/2006 03:11 PM JGM PDA
E110
ELEC, ROUGH IN
IC
need slab ground
E150
ELEC, FINAL
IC
September 11, 2006 4:37:26 PM ncochran
E150
ELEC, FINAL
IC
02/08/2007 03:20 PM RH PDA
E150
ELEC, FINAL
IC
light fixtures missing in bathroom. soffit, smoke detector
E150
ELEC, FINAL
IC
missing
Page 1
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning .
Owner . . . . . .
Contractor . . .
5/25/07
660050-0203-0220
4752 JOHNSON CREEK LOOP
COLLEGE STATION TX 77845
WILLIAMS CREEK PH 2
WILLIAMS CREEK 42, BLOCK 3, LO
T 22, ACRES 1.085
RURAL RESIDENTIAL SUB.
. WESTERHEIM, BRANDON S DBA
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . . . . . .
WESTERHEIM CUSTOM HOMES
979 680-1655
06-00001280 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Buioding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
(5%25/2007) Gina Southerland Re: Calling for CO "@ 4752 Johnson Creek Loo Page 1
From: Paul Schoenfeld
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 5/4/2007 8:18 AM
Subject: Re: Calling for CO @ 4752 Johnson Creek Loop
ALL OK.
PAUL
>>> Nicole Cochran 5/4/2007 8:15 AM >>>
Issues?
BP# 06-1280
Thanks!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.gov
JUN 02,2006 13:35 9796964164
Page 1
L1E-Lhc-cl91Jb 'lU"�_
I-YIf_IL. I•IIL.1.111197 LI{INi }I,INU� 'ii'`4"rr,'-r��,
I'FI�:iL
1
1 112-
Rod lot 6 Lot Non
Rod f /
RoFn
i
cvl � 1
�
A' e+'2s
' Rod rnd.
1 1 !
r--
/
1 11 I
f
I q75Z
JOHN5001
1 l
car 22
q;r 1 I I
�ati
I
"
l,ol 21
Nlr&F- 1 — W'
1
vs
11 41218
I
1 1 1 I I
r F,Vl �.. •� .� 1 4 �L � � L,y— I I
I
I
y-5m.00'
'^ 4-120.09'
Rod rnd.
j
112" Wn r'•-60..70'
i%d phd lC 119,84'
tR=s lac: ur` w
i
I
(ea# and Actuvo
I
FORM SURVEY
I
4752 Johnson Creek Loop
Prepared For.• Westerheim Custom
Homes
OilYM Ula ( CaM�a SMaEMraJAaiw Cw•�b� T P?cYNlby EO Ib M&W NQ
.
rao f" M W RAW Ay+ Ib a/ l5.i 07Ia f' AUearW a/ Acv Lbwy. �wnn,
A v~w &WW RI�p.✓ 1�4 AH! �. AayyMMM 0" Pw
r dw rweU► uI o rPwp' Ms.J e� dw wwN{ ��aYr A' an .�n� J,
j
}Ot:K Jwe M eew wd awrnnf ti � 6wf of �• ba*Idlw
II!
1
1/WOW Ovo* FROM M mi—i-eh an !YM �'JI' �'Ni..w,A w1 odfwM,t RaMO% w�. eb
0 M No YMs►h
Aw w iw "t e..Aewn f7w
11gF fn WYlrl a fAva/ /Ao�rd d4'cM P�p� o Mwap.� Noi1
grq.wd y� .$a[wfl
yye Ab, b0�/y�yyytQcc�b� laf�/ tibM�y C, A70Q
j�
,
69
i
ley*,�..����r.�►• t'
1 � �
er IcR
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
PLAN REVIEW/PERMIT NUMBER# _ Z o
DATE: �/ /L
BUILDING ADDRESS: Ljgsa
I. Foundation Requirements
N K
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier
1. 6 mil poly
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/gW
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Narrow Wall Bracing Methods indicated on plans
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M.
N.
Span exceeding code tables must be engineered
Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N7
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
Al 4
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6 Development Services
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
A/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
{�
/"
CITY OF COLLEGE STATION
Planning cr Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
-Z
LANS EXAMINER DATE
WESTERHEIM CUSTOM HOMES
4752 JOHNSON CREEK
LOT 22 BLOCK 3
WILLIAMS CREEK PHASE 3
SCALE : I' = 40'
REScheck Compliance Certificate
2000 IECC
REScheck Solware Version 3.6 Release la
Data filename: C:\Program Files\Check\REScheck\4752 Johnson Creek.rck
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.17
DATE: 04/24/06
DATE OF PLANS: 04-2006
PROJECT DESCRIPTION:
4752 Johnson Creek Loop
DESIGNER/CONTRACTOR:
Westerheim Custom Homes
COMPLIANCE: Passes
Maximum UA = 1130
Your Home UA = 873
22.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.38
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.38
Door 1: Glass
SHGC: 0.38
Door 2: Glass
SHGC: 0.38
Door 3: Glass
SHGC: 0.38
Door 4: Solid
Floor 1: Slab-On-Grade:Unheated
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
-Value
-Value
U-Factor
2763
30.0
0.0
97
156
19.0
0.0
8
2887
13.0
3.6
164
387
0.640
248
43
0.310
13
43
0.310
13
19
0.310
6
19
0.150
3
308
0.0
321
i
i
Furnace 1: Forced Hot r, 7 AFUE
Boiler 1: Gas -Fired St , 7i AFUE
Boiler 2: Gas -Fired Steam, 7 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in REScheck Version 3.6 Release la (formerly MECcheck) and to comply with the
mandatory requiremerA listey#in * V}Scheck Inspection Checklist.
TRANSMISSION VERIFICATION REPORT
TIME 06/22/2006 16:34
NAME
FAX
TEL
SER.# 000L5J596800
DATE,TIME
06/22 16:34
FAX NO./NAME
98215796
DURATION
00:00:41
PAGE(S)
01
RESULT
OK
MODE
STANDARD
ECM
Appnestlon 06-00001:
119onds
® Contractor ea)crow
IM Foos
i ••� Global balance du
® miscellaneous Inrc
® kimRi
® Permits
® Plan tracking
® -Receipts
® square Footaoe ca
Structures
'valuation calculate
tlddxvss:
4752 ,7[DOa m Cm= Lop
COOmm = *x=, mac 79045
l.ncatian ID
102192
Owner name; I'I
OUHWM XWETMITS Me
P"Pertl 7AF
6e13050=0203-0 20
R802317
Zcadim: i
1DII9
c'eal.ector IQamel 1w5'OOmmm C=Tw NOS=
Contractor fiber: 15-00201)96
Two: Mum. cOm90i071SOR
SCat". ]ICPNB
contractor I.-Dob imMsr
1
p piicaribn status:
CLOSED
status Pate:
6122/2001
110.11cat10A type:
TDB PMZ
tioucation elate:
a►Ta/zoos
valvatioa:
a
SQms i;VOt !
O
MUG hvildiA4:
go
OUMAnding inepe
imp ScLeaale ConUrmatSoh
Too ID Dot* FEWbaF
------------- ------ ---------- - -,
go outetal"
BUILDING PERMIT
CITY OF COLLEGE STATION -
1101 TEXAS RVEr
COLLEGE STATION, TX 77840
PHONE: (979)764-3570
------------------------------------------=---------------------------------
FAX: (979)764-3496
Application Number .
. . . . 06-00001280 Date 4/26/06
Property Address . .
. . . . 4752 JOHNSON CREEK LOOP,
Property ID:
660050-0203-0220
R #:
R****
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . WILLIAMS CREEK PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . RURAL RESIDENTIAL SUB.
Application valuation
. . . . 197142
Owner
Contractor
------------------------
------------------------
WESTERHEIM CUSTOM HOMES
3800 SH 6 S 108
COLLEGE STATION TX 77845
(979) 680-1655
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2987.00
INTERIOR WALL TYPE SHEET ROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 329.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
754.00 Plan Check Fee .00
Issue Date . . . .
4/26/06 Valuation . . . . 197142
Expiration Date . .
10/23/06
Qty Unit Charge
Per Extension
BASE FEE 460.00
98.00 3.0000
THOU BLDG, VAL 100001-500000 294.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIM ROUGH -FRAMED SIZE 22"
------------------------------------------ ---- IV -- ---�-- -•-------------
BUILDING DEPT R PRESENTATIVE:_
APPLICANT: 00&&A�
BUILDING PERMIT
CITY OF COLLEGE STATION ,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00001280 Date 4/26/06
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION. SEPTIC SYSTEMS INSTALLED
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK S DONE IN ORDER TO
BUILDING DEP EPRESENTATIVE:
�/�i (VA 1__11III A;
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00001280 Date 4/26/06
----------------------------------------------------------------------------
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Minimum Finished Floor 278' for sewer.
Septic system.
-------------------------------------- - - - --- ----- --- -- -- ------ - - - - --
BUILDING DEP� ]Ri P,fi RESE ff jVE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 06-00001280 Date 4/26/06
----------------------------------------------------------------------------
Special Notes and Comments
Must Meet all electrical requirements.
Narrow wall bracing fully sheathed
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
754.00 754.00 .00 .00
.00 .00 .00 .00
754.00 754.00 .00 .00
-
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE '
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00001281 Date 4/26/06
Property Address . . . . . . 4752 JOHNSON CREEK LOOP
Property ID: 660050-0203-0220
R #: R****
Application type description TEMP POLE
Subdivision Name . . . . . . WILLIAMS CREEK PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
WESTERHEIM CUSTOM HOMES
3800 SH 6 S 108
COLLEGE STATION TX 77845
(979) 680-1655
----------------------------------------------------------------------------
Permit TEMP POLE PERMIT
Additional desc BK
Permit Fee . . . . 20.00
Issue Date . . . . 4/26/06 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
--------------------------------------------- ------ --- ----- -----------
BUILDING DEPT ��ttEPRESENTfIVF}:
1/ OIIDnd--hI Il_
APPLICANT:
IL f
a APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning c4 Development Services
WWW.CSTX.GOV
ADDRESS/LOCATION: 4752 JOHNSON CREEK LOOP
(� For Offl a Use Only
DATE: '1Q RE -
APPLICATION # (,�► (VV�
TEMP POLE # r t7
LOT 22 ✓BLOCK SUBDIVISION WILLIAMS CREEK / SEC/PH 2 1----
BUSINESS/OWNER NAME: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163
CONTRACTOR/HOMEOWNER: WESTERHEIM CUSTOM HOMES PHONE:979-696-4163
I CONTRACTOR ADDRESS: 3800 HWY 6 STE 108B COLLEGE STATION, TX 77845
ELECTRICIAN: HILCO
PLUMBER: JB PLUMBING
HVAC: SEIGERT GOOD CENTS (Residential only): YES
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NEW HOME
STRUCTURE USE: SINGLE FAMILY DWELLING
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARDR S) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 1aq i 1 y� I TOTAL AREA:4039 HEATED AREA:2987
(Cost of Labor and Materials)
❑ PUBLIC SEWER NUMBER OF BEDROOMS: 4
I �X SEPTIC/TREATMENT SYSTEM
.SEWER TAP:
WATER TAP:
I OTHER TAP:
I [jg TEMP POLE
GARAGE TYPE:
SIZE
SIZE
Ser a
SINGLE ED
ATTACHED M
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE 0 TRIPLE
DETACHED F__] CARPORT
SHEETROCK
BRICK/STONE
SLAB ON GRADE
COMP SHINGLES
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
TeS q-zs -,a<
Plans Examiner
-.4At . FF a 7 6 4L
ents:
ES o NO
✓, Zoning Official
- ram' AA 6(e(e 'c-A
Energy Code Compliance Information
% Glazing of exterior walls 13.0 e--
Insulation R value of exterior walls 13.0 e"
Insulation R value of ceiling 1 (flat areas) 30 "--
Insulation R value of ceiling 2 (vaulted areas/no attic) 19 1---'
Glazing SHGC 0.39
Glazing U-Factor 0.64
R value of ductwork 6
A/C SEER Rating 14