Loading...
HomeMy WebLinkAboutRES2006-01272, 06-1273OPendaffor R 7521/3 10% P4 e WF0763650 / 001 City of College Station N PAGE 1 REQ. DATE: 04/26/06 �,,, 4/26/06 15:05:24 LOCATION: 8428 TURTLE ROCK LOOP LOC ID: 198956 REQUESTOR: sunset homes ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT temp pole passed TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/26/06 SCHED COMPLETION: 04/26/06 ******************************************************************************** JOB ORDER RESULT COME TI'S ( ^ VJ' tniA PREPARED 8/11/06, 7:23:47 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/10/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 8428 TURTLE ROCK LOOP SUBDIV: EMERALD FOREST ##11 CONTRACTOR SUNSET HOMES PHONE (979) 680-1033 OWNER EMERALD FOREST JOINT VENTURE PHONE PARCEL 249000-1122-0040 APPL NUMBER: 06-00001272 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B10,_Q,011 5/04/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 t' 5/04/06 AP T/S: 05/03/2006 04:02 PM GLSOUTH ----------------------- AFTERNOON 05/04/2006 02:48 PM RH PDA Strings up, slab ground installed. B115 01 6/06/06 OC BLDG, FRAMING TIME: 17:00 6/06/06 AP June 5, 2006 4:42:50 PM kwolfe B130 01 6/07/06 OC BLDG, INSULATION TIME: 17:00 6/07/06 AP June 6, 2006 11:27:48 AM bkorthauer AM B125 01 8/08/06 JGM BLDG, FINAL TIME: 17:00 8/08/06 DA August 7, 2006 3:34:20 PM kwolfe 08/08/2006 11:36 AM JGM PDA address needs to be totally visioble from street B125 02 8/ 0/06 BI BLDG, FINAL TIME: 17:00 1((O v A-P d(- August 10, 2006 4:33:21 PM kwolfe -------------------------------------- COMMENTS AND NOTES --------------------------------------- I �, I (n L-r r% *, on s hs ��i Date: 8/11 /2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1272 Address: 8428 TURTLE ROCK LOOP Type Inspection Type Code Status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC 05/04/2006 02:48 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B125 BLDG, FINAL IC 08/08/2006 11:36 AM JGM PDA B125 BLDG, FINAL IC address needs to be totally visioble from street Page 1 WF0762691 / 001 City of College Station PAGE 1 REQ. DATE: 04/24/06 04/24/06 17:06:28 LOCATION: 8428 TURTLE ROCK LOOP LOC ID: 198956 REQUESTOR: sunset homes ORIGIN.: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH, WORK TYPE: ROUT SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/24/06 SCHED COMPLETION: 04/24/06 ******************************************************************************** JOB ORDER RESULT COM14ENTS -'c-1 BUILDING PERMIT CITY OF COLLEGE.STATION 1101 TEXAS AVE COLLEGE STATION,ITX 77840 fRONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00,001272 Date 4/24/06 8428 TURTLE ROCK LOOP 249000.-1122-0040 R116221 RESIDENTIAL, 1 UNIT DETACHED NEW EMERALD FOREST 411 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 171600 Owner Contractor EMERALD FOREST JOINT VENTURE SUNSET HOMES #1 3946 ARBOLEDA 2103 TABOR RD COLLEGE STATION TX 77845 BRYAN TX 778035224 (979) 680-1033 -------------------------- Structure Information 000 000 ----------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2600.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 244.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc BK Permit Fee . . . . 676.00 Plan Check Fee .00 Issue Date . . . . 4/24/06 Valuation . . . . 171600 Expiration Date . . 10/21/06 Qty Unit Charge Per Extension BASE FEE 460.00 72.00 3.0000 THOU BLDG, VAL 100001-500000 216.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ----- --- - ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, Tk 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00001272 Date 4/24/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTE PLANS MUST BE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - • - - y- - - - - - - - - - - - BUILDING DEPT .1. � P,R SENTATIVE: L%s APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00001272 Date 4/24/06 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN -------------------------------------------- ------ ---- ------------------- BUILDING DEPT AV= APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001272 Date 4/24/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Narrow wall bracing Fully Sheathed with Simpson Panel at back door and APA ---------------------------------------------------------------------------- garage framing. Other Fees . . . . . . . . . SEWER TAP 4" .350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited -------------------- Due ---------- Permit Fee Total 676.00 676.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1426.00 1426.00 .00 .00 - TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00001273 Date 4/24/06 8428 TURTLE ROCK LOOP 249000-1122-0040 R116221 TEMP POLE EMERALD FOREST #11 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor EMERALD FOREST JOINT VENTURE SUNSET HOMES #1 3946 ARBOLEDA 2103 TABOR RD COLLEGE STATION TX 77845 BRYAN TX 778035224 (979) 680-1033 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc BK Permit Fee 20.00 Issue Date 4/24/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 -------------------------------------------- ----- ------------ BUILDING DEPT REPRE�NTATIVE: APPLICANT: T APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX. US ADDRESS/LOCATION LOT a/'"OCBLOCK BUSINESS/OWNER NAME: IV w onryDATE: APPLICATION # TEMP POLE # SUBDIVISION Off_ � s /d ,/"G-.,'f� $ /p 11- _ E`CH 1*r ►C S PHONE: '1f1 rfla33 cc CONTRACTOR/HOMEOWNER: e, Q / PHONE: CONTRACTOR ADDRESS: l �yb A � Ztr X ,N ELECTRICIAN: X'// (��lC� PLUMBER: /7�I1 n, HVAC: _ /"od'�l ,yyC IiI`Ccpz- GOOD CENTS (Residential only): w CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION VING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: F,dm rAWIC14� 45qE f _/kcl STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ ! VALUATION: $ -1 n JO TOTAL AREA: %/� �9 HEATED AREA: O 0 (Co; ofL do and Materials) P11PUBLIC SEWER NUMBER OF BEDROOMS: L/ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: /� • r/ SEWER TAP: INTERIOR WALL TYPE: 5dr(/G ZE r/ WATER TAP: EXTERIOR WALL TYPE: If SIZE SIZE OTHER TAP: FOUNDATION TYPE: ! / S/(J SIZE T MP POLE ROOF TYPE: ! �/ �P"'���J/ ASS^ �'YR't y l( GARAGE TYPE: SINGLE F__1 DOUBLE �RIPLE a ATTACHED F,-R-""DETACHED a CARPORT SIGNATURE OF APPLICANT: 469� *If proposed work involves new commercial c nstruction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Cow ents: �YES**rNO mv, �fho Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls i Insulation R value of ceiling I (flat areas) 30. Insulation R value of ceiling-2 (vaulted areas/no attic) �y Glazing SHGC yj} Glazing U-Factor R value of ductwork A/C SEER rating % l PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning er Development Services PLAN REVIEW/PERMIT NUMBER# 0(0 _ DATE: y /zi /06 BUILDING ADDRESS: 2qa19 —r„a+lti &,k [tea I. Foundation Requirements NA/ K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30") 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated Al II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning c5 Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N7 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward t 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Mason fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than an portion of the buildingwithin ten 10 feet horizontal (*0Fq" CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements NA K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N K A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed 44 Street Ordinance Requirements t4AON Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 CfflOK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning c ' Development Services Comments: LANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS DATE REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.6 Release 1 Data filename: Untitled.rck PROJECT TITLE: Spec#2600 LT4 CITY: Bryan (Brazos) STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.16 DATE: 04/20/06 DATE OF PLANS: 4/21/06 PROJECT DESCRIPTION: 8428 Turtle Rock Loop DES IGNER/CONTRACTOR: Sunset Homes COMPLIANCE: Passes Maximum UA = 651 Your Home UA = 489 24.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling l: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Unspecified Projection factor: 0.00 Door 1: Solid Door 2: Glass SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Unspecified Projection factor: 0.00 Door 3: Solid Furnace 1: Forced Hot Air, 78 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U--Fact2 UA 2600 30.0 0.0 91 2390 13.0 0.0 161 366 0.600 220 18 18 21 0.390 7 0.390 7 0.150 3 Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchec.i and to comply with the mandatory requirements listed in the RES checkInspection Checklist. / Builder/Designer Date �� o REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.6 Release 1 DATE: 04/20/06 PROJECT TITLE: Spec#2600 LT4 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation I Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.390 Comments: 2. Door 2: Glass, U-factor: 0.390 Comments: 3. Door 3: Solid, U-factor: 0.150 Comments: Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number 2. Air Conditioner 1: Electric Central Air, 13 SEER or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating (F) Runouts Circulating Mains and Runouts Temperature Up to 1" 170-180 0.5 U,p to 1.25" 1.0 1.5" to 1.5 2.0" Over 2„ 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. System Fluid Temp. Insulation Thickness in Inches by Pipe Sizes - " Piping Types Heating Systems Range ( F) 2" Runouts I" and Less 1.25" to 2" Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0' 1.5 1.5 NOTES TO FIELD (Building Department Use Only)