HomeMy WebLinkAboutRES2006-01272, 06-1273OPendaffor
R 7521/3 10% P4
e
WF0763650 /
001 City of College
Station N
PAGE 1
REQ. DATE:
04/26/06
�,,, 4/26/06
15:05:24
LOCATION:
8428 TURTLE ROCK LOOP
LOC ID:
198956
REQUESTOR:
sunset homes
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
temp pole
passed
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
04/26/06 SCHED
COMPLETION:
04/26/06
********************************************************************************
JOB ORDER RESULT COME TI'S ( ^
VJ' tniA
PREPARED 8/11/06, 7:23:47 INSPECTION TICKET PAGE 12
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/10/06
------------------------------------------------------------------------------------------------
ADDRESS . : 8428 TURTLE ROCK LOOP SUBDIV: EMERALD FOREST ##11
CONTRACTOR SUNSET HOMES PHONE (979) 680-1033
OWNER EMERALD FOREST JOINT VENTURE PHONE
PARCEL 249000-1122-0040
APPL NUMBER: 06-00001272 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B10,_Q,011 5/04/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
t' 5/04/06 AP T/S: 05/03/2006 04:02 PM GLSOUTH -----------------------
AFTERNOON
05/04/2006 02:48 PM RH PDA
Strings up, slab ground installed.
B115 01 6/06/06 OC BLDG, FRAMING TIME: 17:00
6/06/06 AP June 5, 2006 4:42:50 PM kwolfe
B130 01 6/07/06 OC BLDG, INSULATION TIME: 17:00
6/07/06 AP June 6, 2006 11:27:48 AM bkorthauer
AM
B125 01 8/08/06 JGM BLDG, FINAL TIME: 17:00
8/08/06 DA August 7, 2006 3:34:20 PM kwolfe
08/08/2006 11:36 AM JGM PDA
address needs to be totally visioble from street
B125 02 8/ 0/06 BI BLDG, FINAL TIME: 17:00
1((O v A-P d(- August 10, 2006 4:33:21 PM kwolfe
-------------------------------------- COMMENTS AND NOTES ---------------------------------------
I �, I (n
L-r r% *, on s hs ��i
Date: 8/11 /2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1272
Address: 8428 TURTLE ROCK LOOP
Type
Inspection Type Code
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
05/04/2006 02:48 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B125
BLDG, FINAL
IC
08/08/2006 11:36 AM JGM PDA
B125
BLDG, FINAL
IC
address needs to be totally visioble from street
Page 1
WF0762691 /
001 City of College
Station
PAGE 1
REQ. DATE:
04/24/06
04/24/06
17:06:28
LOCATION:
8428 TURTLE ROCK LOOP
LOC ID:
198956
REQUESTOR:
sunset homes
ORIGIN.:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH,
WORK TYPE:
ROUT
SWR 4"
WTR 3/411
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
04/24/06 SCHED
COMPLETION:
04/24/06
********************************************************************************
JOB ORDER RESULT COM14ENTS
-'c-1
BUILDING PERMIT
CITY OF COLLEGE.STATION
1101 TEXAS AVE
COLLEGE STATION,ITX 77840
fRONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00,001272 Date 4/24/06
8428 TURTLE ROCK LOOP
249000.-1122-0040
R116221
RESIDENTIAL, 1 UNIT DETACHED NEW
EMERALD FOREST 411
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
171600
Owner Contractor
EMERALD FOREST JOINT
VENTURE SUNSET HOMES
#1
3946 ARBOLEDA
2103 TABOR RD
COLLEGE STATION
TX 77845
BRYAN
TX 778035224 (979) 680-1033
--------------------------
Structure Information 000 000 -----------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2600.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
244.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
BK
Permit Fee . . . .
676.00 Plan Check Fee
.00
Issue Date . . . .
4/24/06 Valuation . .
. . 171600
Expiration Date . .
10/21/06
Qty Unit Charge Per Extension
BASE FEE 460.00
72.00 3.0000 THOU BLDG, VAL 100001-500000 216.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
----- --- - ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, Tk 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00001272 Date 4/24/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTE PLANS MUST BE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - • - - y- - - - - - - - - - - -
BUILDING DEPT .1. � P,R SENTATIVE:
L%s
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00001272 Date 4/24/06
----------------------------------------------------------------------------
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
-------------------------------------------- ------ ---- -------------------
BUILDING DEPT
AV=
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00001272
Date 4/24/06
----------------------------------------------------------------------------
Special Notes and
Comments
PRIVATE GARAGES
Narrow wall bracing Fully Sheathed
with Simpson
Panel
at
back door and APA
----------------------------------------------------------------------------
garage framing.
Other Fees . . .
. . . . . .
SEWER TAP 4"
.350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
--------------------
Due
----------
Permit Fee Total
676.00
676.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1426.00
1426.00
.00
.00
-
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00001273 Date 4/24/06
8428 TURTLE ROCK LOOP
249000-1122-0040
R116221
TEMP POLE
EMERALD FOREST #11
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner Contractor
EMERALD FOREST JOINT VENTURE
SUNSET HOMES
#1
3946 ARBOLEDA
2103 TABOR RD
COLLEGE STATION
TX 77845
BRYAN
TX 778035224
(979) 680-1033
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
BK
Permit Fee
20.00
Issue Date
4/24/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------------------------------- ----- ------------
BUILDING DEPT REPRE�NTATIVE:
APPLICANT:
T
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX. US
ADDRESS/LOCATION
LOT a/'"OCBLOCK
BUSINESS/OWNER NAME:
IV
w onryDATE:
APPLICATION #
TEMP POLE #
SUBDIVISION Off_ � s /d ,/"G-.,'f� $ /p 11-
_ E`CH
1*r ►C S PHONE: '1f1 rfla33
cc
CONTRACTOR/HOMEOWNER:
e,
Q / PHONE:
CONTRACTOR ADDRESS: l �yb A � Ztr X ,N
ELECTRICIAN: X'// (��lC� PLUMBER: /7�I1 n,
HVAC: _ /"od'�l ,yyC IiI`Ccpz- GOOD CENTS (Residential only): w
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION VING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: F,dm rAWIC14� 45qE f _/kcl
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ ! VALUATION: $ -1 n JO TOTAL AREA: %/� �9 HEATED AREA: O 0
(Co; ofL do and Materials)
P11PUBLIC SEWER NUMBER OF BEDROOMS: L/
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
/� •
r/
SEWER TAP: INTERIOR WALL TYPE:
5dr(/G
ZE r/
WATER TAP: EXTERIOR WALL TYPE:
If
SIZE
SIZE
OTHER TAP: FOUNDATION TYPE:
! /
S/(J
SIZE
T MP POLE ROOF TYPE:
! �/
�P"'���J/ ASS^ �'YR't y l(
GARAGE TYPE: SINGLE F__1 DOUBLE �RIPLE
a
ATTACHED F,-R-""DETACHED a CARPORT
SIGNATURE OF APPLICANT: 469�
*If proposed work involves new commercial c nstruction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
Cow ents:
�YES**rNO
mv,
�fho
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
i
Insulation R value of ceiling I (flat areas) 30.
Insulation R value of ceiling-2 (vaulted areas/no attic) �y
Glazing SHGC yj}
Glazing U-Factor
R value of ductwork
A/C SEER rating % l
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
PLAN REVIEW/PERMIT NUMBER#
0(0 _
DATE: y /zi /06
BUILDING ADDRESS: 2qa19
—r„a+lti &,k [tea
I. Foundation Requirements
NA/ K
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30")
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
Al
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning c5 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N7
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
t
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Mason fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than an portion of the buildingwithin ten 10 feet horizontal
(*0Fq"
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
NA K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
44
Street Ordinance Requirements
t4AON
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
CfflOK
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning c ' Development Services
Comments:
LANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.6 Release 1
Data filename: Untitled.rck
PROJECT TITLE: Spec#2600 LT4
CITY: Bryan (Brazos)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.16
DATE: 04/20/06
DATE OF PLANS: 4/21/06
PROJECT DESCRIPTION:
8428 Turtle Rock Loop
DES IGNER/CONTRACTOR:
Sunset Homes
COMPLIANCE: Passes
Maximum UA = 651
Your Home UA = 489
24.9% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Ceiling l: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Unspecified
Projection factor: 0.00
Door 1: Solid
Door 2: Glass
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Unspecified
Projection factor: 0.00
Door 3: Solid
Furnace 1: Forced Hot Air, 78 AFUE
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter
R-Value
R-Value U--Fact2 UA
2600
30.0
0.0 91
2390
13.0
0.0 161
366
0.600 220
18
18
21
0.390 7
0.390 7
0.150 3
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchec.i and to comply with the
mandatory requirements listed in the RES checkInspection Checklist. /
Builder/Designer Date �� o
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.6 Release 1
DATE: 04/20/06
PROJECT TITLE: Spec#2600 LT4
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
I Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.390
Comments:
2. Door 2: Glass, U-factor: 0.390
Comments:
3. Door 3: Solid, U-factor: 0.150
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 13 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches
by Pipe Sizes
Heated Water Non -Circulating
(F)
Runouts
Circulating
Mains
and Runouts
Temperature Up to 1"
170-180 0.5
U,p to 1.25"
1.0
1.5" to
1.5
2.0"
Over 2„
2.0
140-160 0.5
0.5
1.0
1.5
100-130 0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
System
Fluid Temp.
Insulation Thickness
in Inches by Pipe
Sizes -
"
Piping Types
Heating Systems
Range ( F)
2" Runouts
I" and
Less 1.25" to 2"
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0'
1.5
1.5
NOTES TO FIELD (Building Department Use Only)