Loading...
HomeMy WebLinkAboutRES2006-01229, 06-1230O(A ott = «3o c,�) s u H752113 70%ISP4 c Gina Southerland - Re: Calling for CO @ 923 Crested Point Dr Page 1 r` From: Joe Garcia To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie Date: 9/18/2006 10:50:27 AM Subject: Re: Calling for CO @ 923 Crested Point Dr The water meter box has been raised. This one is good to go. JMG >>> Terry Boriskie 09/15/06 2:50 PM >>> Contacted Bob at Stylecraft and he will get it fixed. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Joe Garcia 9/15/2006 2:32 pm >>> WTER METER BOX NEEDS TO BE RAISED ABOUT 6". JMG >>> Nicole Cochran 09/15/06 12:15 PM >>> Are there any issues? BP # 06-1229 Thanks so much! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov PREPARED 9/13/06, 11:43:01 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/13/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 923 CRESTED POINT DR SUBDIV: WESTFIELD VILLAGE PH 4 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0408-0110 APPL NUMBER: 06-00001229 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100101 5/18/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 5/18/06 DA May 18, 2006 9:24:28 AM kwolfe 05/18/2006 04:30 PM JGM PDA ,. reloocating plumbing need new test B100 02 5/19/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/19/06 AP May 18, 2006 4:50:06 PM bkorthauer B130-01 7/12/06 JGM BLDG, INSULATION TIME: 17:00 7/12/06 CA July 12, 2006 9:34:51 AM glsouth B115 01 7/18/06 OC BLDG, FRAMING TIME: 17:00 7/18/06 AE July 17, 2006 2:44:01 PM bkorthauer Sheetrock Fireplace Chase, Firestopping B130 02 7/19/06 OC BLDG, INSULATION TIME: 17:00 7/19/06 AP July 19, 2006 9:51:31 AM bkorthauer B132 01 7/21/06 JGM BLDG, SHEETROCK FASTENER TIME: 17:00 7/21/06 AP July 20, 2006 2:20:00 PM bkorthauer B125 01 9/13/06/ BI BLDG, FINAL TIME: 17:00 September 13, 2006 10:44:50 AM glsouth -------------------------------------- COMMENTS AND NOTES-------------------------------------- fto Nc_ e,p-161W Date: 9/13/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1229 Address: 923 CRESTED POINT DR Insp. inspection Type Code statu s Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC 05/18/2006 04:30 PM JGM PDA B100 BLDG, FOUNDATION -SLAB IC reloocating plumbing need new test B115 BLDG, FRAMING IC Sheetrock Fireplace Chase, Firestopping E150 ELEC, FINAL IC 08/24/2006 02:59 PM RH PDA E150 ELEC, FINAL IC Left on hot. Need 3 ft. from a/c vent in livingroom by E150 ELEC, FINAL IC building final. Page 1 WF0762175 / 001 City of ,--ollege Station PAGE 1 REQ. DATE: 04/21/06 04/21/06 14:07:46 LOCATION: 923 CRESTED POINT DR LOC ID: 203794 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/21/06 SCHED COMPLETION: 04/21/06 ******************************************************************************** JOB ORDER RESULT COW4ENTrS City of Col lege Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning Owner . . . . . . . . 9/20/06 005401-0408-0110 923 CRESTED POINT DR COLLEGE STATION TX 77845 WESTFIELD VILLAGE PH 4 WESTFIELD VILLAGE PH 4 BLOCK 8 LOT 11 PLANNED DEVL HOUSING Contractor . . . . . . STYLECRAFT BUILDERS 979 690-1222 Application number 06-00001229 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved . . . . . . . v 11 ldfng Of F-icial VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING.'.,IPERMIT CITY OF CC ;a 3 STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-b0001229 Date 4/21/06 Property Address . . . . . . 923 CRESTED POINT DR Property ID: 005401-0408-0110 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 83490 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1265.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc KW Permit Fee . . . . 396.00 Plan Check Fee .00 Issue Date . . . . 4/21/06 Valuation . . . . 83490 Expiration Date 10/18/06 Qty Unit Charge Per Extension BASE FEE 260.00 34.00 4.0000 THOU BLDG, VAL 50001-100000 136.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROU -FRAME SIZ 2a" ---------------------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001229 Page 2 Date 4/21/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS ONE IN ORDER TO ---------------------------------�J -- ---`---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001229 Page 3 Date 4/21/06 Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------- ----- --- ----- ----------- BUILDING DEPT REPRESENTATIVE: • APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001229 Date 4/21/06 ---------------------------------------------------------------------------- Special Notes and Comments Engineered Methods used for narrow wall bracing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 396.00 396.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1146.00 1146.00 .00 .00 -----------------------------------------J61F /�:- - avfi.�---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001230 Date 4/21/06 Property Address . . . . . . 923 CRESTED POINT DR Property ID: 005401-0408-0110 R #. Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc KW Permit Fee . . . . 20.00 Issue Date . . . . 4/21/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------- - - - - -- - -- �.J.------ - - -- BUILDING DEPT REPRESENTATIVE: I�N- APPLICANT: For Ofte Use Only APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d-De IoynnrntSr uw WWW_CSTX.GOV ADDRESS/LOCATION: LOT BLOCK g DATE: 14 ' ! UeC REG q APPLICATION # ' ( Q � 1 TEMP POLE # /' QL30_ SUBDIVISION WFSTFiF--LO VILLAaV-- SEC/PH 4- BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbina HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: M /A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 85, 40t O / TOTAL AREA: 113S HEATED AREA: l atoS (Cost of Labor and Materials) 3�( �X PUBLIC SEWER p SEPTIC/TREATMENT SYSTEM ❑X SEWER TAP: 4" SIZE QX WATER TAP: %" SIZE (� OTHER TAP: X TEMP POLE `( GARAGE TYPE 1% SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: 'L INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition SINGLE DOUBLE Z TRIPLE ATTACHED FX DETACHED F] CARPORT SIGNATURE OF APPLICANT: For Stylecraft --o *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only -17 y ZI->-b I(-) pnipents: or NO Plans Examiner ���ivcar,�� �I�-u•g Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork I % R13 R30 R19 .40 --- .65 A/C SEER Rating 13 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6- Development Services PLAN REVIEW/PERMIT NUMBER# ()6 _/ZZ,7 DATE: L/ / zi toG BUILDING ADDRESS: Po irvA 4. I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N7 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes Ala III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated on plans) K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N K A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N K A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side (intersecting) street Subdivision Regulations — Ordinance 690 -NA/019 Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning & Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS q--2(--b( PLANS EXAMINER DATE Permit # Permit Date 0 4, REScheck Software Version 3.7.3 N/, Compliance Certificate Project Title: Plan # 1270-1273 Front Porch Report Date: 04/18/06 Data filename: S:WCAD\Archived\Old REScheck\1270 923 Crested Point.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 17% Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: TX Spec Stylecraft Builders, Inc. Permit Date: 4/18/2006 923 Crested Point 4090 St. Hwy. 6 S. College Station, TX College Station, TX 77845 Corir'$Hance Passes Maxi—m m'11A�479 6 p � _ � _ L Your Homr-f1AlL447;'"6.7„/o BetteF,Ttian CoclLv(UA)� Maximum SHGC: 0.40 -0 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 3: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' Air Conditioner 2: Electric Central Air: 12 SEER Furnace 2: Forced Hot Air: 80 AFUE 1048 30.0 0.0 37 224 19.0 0.0 12 1248 13.0 0.0 82 177 0.670 119 38 0.500 19 33 0.440 15 156 0.0 163 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. L , dilder/Designer Compa4 Name Date Plan # 1270-1273 Front Porch Page 1 of 4 CREScheck Software Version 3.7.3 NJ( Inspection Checklist Date: 04/18/06 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: ❑ Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments - Doors: ❑ Door 1: Solid, U-factor: 0.500 Comments: - - ❑ Door 2: Glass, U-factor: 0.440- Comments: - -- Floors: ❑ Floor 3: Slab -On -Grade: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: ❑ Air Conditioner 2: Electric Central Air: 12 SEER or higher Make and Model Number: ❑ Furnace 2: Forced Hot Air: 80 AFUE or higher Make and Model Number: Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Plan # 1270-1273 Front Porch Page 2 of 4 C1 ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R4. ❑ Supply ducts in unconditioned spaces must be insulated to R-6. ❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ❑ Where exterior walls are used as plenums, the wall must be insulated to R-8. ❑ Insulation is not required on return ducts in basements. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Plan # 1270-1273 Front Porch Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes Fluid Temp. Piping System Types Range(°F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Plan # 1270-1273 Front Porch Page 4 of 4