Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2006-01228
OPendaflor OEss & R 7521/3 10% P4 {r PREPARED 5/31/07, 12:01:02 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/31/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 4002 BITTERN DR SUBDIV: REATTA MEADOWS SEC 1 PH 1 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER BARRON ROAD MEADOWS L.P. PHONE PARCEL 537300-0101-0190 APPL NUMBER: 06-00001228 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/02/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 =6/02/06 AP June 2, 2006 10:00:22 AM bkorthauer <' Strings On Setbacks O.K. Slab Ground Installed B1101 8/09/06 OC BLDG, FRAMING TIME: 17:00 8/09/06 AP July 24, 2006 2:31:46 PM bkorthauer August 8, 2006 12:00:19 PM glsouth B130 01 8/21/06 JGM BLDG, INSULATION TIME: 17:00 8/21/06 AP August 21, 2006 10:12:59 AM bkorthauer 3125 01 5/ 1/47 BLDG, FINAL TIME: 17:00 0? �0 C' May 31, 2007 9:35:11 AM kwolfe. -------------------------------------- COMMENTS AND NOTES-------------------------------------- � � ► �1-," J Ors � �J t I'� S 1 �2, � `� � ��/ Date: 5/31 /2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 1228 Address: 4002 BITTERN DR Insp. Inspection Type Code status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed M100 MECH, ROUGH IN IC 07/20/2006 10:43 AM RH PDA M100 MECH, ROUGH IN IC Need to finish connecting supply duct to plenum before M100 MECH, ROUGH IN IC framing inspection. P105 PLBG, TOP OUT IC 08/08/2006 11:35 AM OC PDA P105 PLBG, TOP OUT IC no pres. on system Page 1 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 * TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00002327 . Date 7/25/06 Property Address . . . . . . 4006 BITTERN DR Property ID: 537300-0101-0210 R #: R300676 Application type description TEMP POLE Subdivision Name . . . . . . REATTA MEADOWS SEC 1 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ED FROEHLING BUILDER INC ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc KW Permit Fee . . . . 20.00 Issue Date . . . . 7/25/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------ BUI L: APPL WF0763147 / 001 City of College Station PAGE 1 REQ. DATE: 04/25/06 04/25/06 15:04:31 LOCATION: 4002 BITTERN DR LOC ID: 200870 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/25/06 SCHED COMPLETION: 04/25/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0806387 / 001 edty of College Station PAGE 1 REQ. DATE: 07/26/06 07/26/06 10:48:28 LOCATION: 4002 BITTERN DR LOC ID: 200870 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 07/26/06 SCHED COMPLETION: 07/26/06 ******************************************************************************** JOB ORDER RESULT CONIl4MTS a t, BUILDING PERMIT CITY iQF,�C�LLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001228 Date 4/25/06 Property Address . . . . . . 4002 BITTERN DR Property ID: 537300-0101-0190 R #: R300674 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . REATTA MEADOWS SEC 1 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 123684 Owner Contractor ------------------------ BARRON ROAD MEADOWS L.P. ------------------------ ED FROEHLING BUILDERS PO BOX 277 ED FROEHLING NORMANGEE TX 778710277 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1874.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 532.00 Plan Check Fee .00 Issue Date . . . . 4/25/06 Valuation . . . . 123684 Expiration Date . . 10/22/06 Qty Unit Charge Per Extension BASE FEE 460.00 24.00 3.0000 THOU BLDG, VAL 100001-500000 72.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT �-------------- --------INTERRUPTERS) BUILDING DEPT,,REPRESENTATIVE: - APPLICANT: BUILDING PERMIT CITYvOF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00001228 Date 4/25/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITT PLANS MUST BE --------------------------------------------- ---IV• ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY.OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00001228 Date 4/25/06 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI=SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN -----------------------------------------------I`./•--------------- BUILDING DEPT REPRESENTATIVE: nA .. .!_ APPLICANT: BUILDING PERMIT CITY;OF GOLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001228 Date 4/25/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Narrow wall bracing Fully Sheathed with APA garage framing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- ---------- Due ----------------- Permit Fee Total ---------- 532.00 532.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1282.00 1282.00 .00 .00 I -- --------------------------------------------- ----1----------- 1 BUILDING DEPTn�EPRESENTATI VE: APPLICANT: APPLICATION FOR (BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Pknningc�DevelopmentServica /-�-00 2 �j usenly DATE: 4XTRCC REG APPLICATION # ©(0 TEMP POLE # ADDRESS/LOCATION: t V t< LOT 19 BLOCK l SUBDIVISION 1 t IDO1l�S/ BUSINESS/OWNER NAME: PHONE: G SEC/PH CONTRACTOR/HOMEOWNER:'F-X> }��f}l..t '�11 �IJIL-DETs PHONE: �7CD�aZ.� CONTRACTOR ADDRESS: �-7 i-�LC--�{i LOt�tG1�E51"1C Q!�P.-D ELECTRICIAN: 1E) � f5 PLUMBER: __7P1 tPLJ zj HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION VING SHELL ONLY DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJE REGISTRATION# EABPRJ VALUATION: $ 12-3i �Sd- • DO TOTAL AREA: ?Aza HEATED AREA: (Cost of Labor and Materials) N PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: �WA TER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SINGLE a ATT SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: Fos z FOUNDATION TYPE: C Qj� GIPAZ�___ ROOF TYPE: DOUBLEED TRIPLE a FP_T�CHED F__j CARPORT *If proposed work involves new commt-rEallco tr ion commercial property, building elevations are required. Official F117 Plans Examiner Zoning Official YES r NO �,-t44k/ 6 or facade provements/renovations to an existing se Only Fire Marshall �_W Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating L t 0iR cat-�s2v YEW 9s,,�t�L- Hu#Z (*f/4544 CITY OF COLLEGE STATION Planning 6 Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# 06_ zy DATE: c/ lu / o,6 BUILDING ADDRESS: po 2 I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. '4 (*hrq5* CITY OF COLLEGE STATION Planning c ' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N'T 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes A Ill. Stairway Requirements K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated on plans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning er Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units 'T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vlll. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed AAfil Street Ordinance Requirements Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 VOK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning d Development Services Comments: LA S EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS DATE l REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1209SB.rck TITLE: 4002 BITTERN DRIVE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/13/06 DATE OF PLANS: APRIL 13, 2006 PROJECT INFORMATION: SPEC HOME LOT 19 BLOCKI REATTA MEADOWS COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: SMALL NARROW PALASOTA COMPLIANCE: Passes Maximum UA = 679 Your Home UA = 578 14.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.35 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Front Projection factor:' 0.18 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Left Side Projection factor: 0.18 Wall 3: Wood Frame, 16" o.c. Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1874 30.0 0.0 66 348 13.0 0.0 20 60 0.650 39 46 392 13.0 0.0 56 378 13.0 0.0 0.400 18 28 0.650 36 25 Window 3: Metal Frame:Double Pane with Low-E 58 0.650 38 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.33 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 490 13.0 0.0 34 Window 4: Metal Frame:Double Pane with Low-E 75 0.650 49 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 206 0.0 215 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in the RES checklnspec ' ecklist. Builder/DezWner Date /C) CP Ala„ 2�1, 26 1 3i'M \1c C 1.re & Bro*n: Eng'Sure 1155 r', 2 AVCW'?Fd6G4l0fYX�ENG/iY�EJF/rV 'l/lP4fYING, /YG• fA�9fl�aadc> D�ir�s, S�iri� �d.1 • Ca/h�a.Sf�dbvr, T vs7l&o� •/91yj�8 Lot 19 Block 01.dwg CURIT ra&EE CURVE DEVA RADIUS LINGTH CHORD. SM, V/ 01 3428743` 50.00' 33.00' S 85'48'12' E Bl tteli) D/7VB 50' A0.W V' \ Vol 5114 Pg. 47 � BeakfCurb a9 66' C1 J i NV; � N I Proposed 1 Driveway I ...._ 43.5' I f» scule: t' = 20' i Proposed I V� Res�denre ---.�Y LW- 1$ Now or formerly 44 k � Boron Road ►Mecdows L P. Vol, 6118, Pg. 47 7s� a Lot t g 4wook l i Reatto AoWd�ows SubdiVis�ion 7.5' — Note: Bldg. Setback -nee �� J per Finol Plot (6118/47), 15' U.E. v/ E N 45 76" In 59.OQ' Kdol a Avenue 7o' R.D.W. Vol. 6118, Pg. 47 r ,l Lot 20 Now or Formerly 4 Barron Rood Meodcwe L.P. I Vol. 6114, Pg. 47 ,w �i