HomeMy WebLinkAboutRES2006-01213OPendaffor
/3Esse/te
R 7521/3 10%19P4
r
J^
PREPARED
4/24/07, 11:24:51
INSPECTION TICKET PAGE 2
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 4/24/07
ADDRESS
. : 4303 WHITWICK PL
SUBDIV: CASTLEGATE SEC 3 PH 2
CONTRACTOR PHILIP
BLACKBURN
(MAVERICK) PHONE (979) 693-2364
OWNER
GREENS
PRAIRIE INVESTORS LTD PHONE
PARCEL
184200-2301-0200
APPL NUMBER: 06-00001213 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/24/06
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
4/25/06
AP
April 24, 2006 2:07:01 PM bkorthauer
AFTERNOON
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/23/06
OC
BLDG, FRAMING TIME: 17:00
6/23/06
DP
June 23, 2006 10:42:52 AM kwolfe
Loose Or Missing Anchor Bolt Nuts
Joist Hangers Needed
1
06/23/2006 03:09 PM OC PDA
alt. walls missing.
B115 02
6/27/06
OC
BLDG, FRAMING TIME: 17:00
6/27/06
AP
June 26, 2006 4:12:55 PM kwolfe
early AM
r'
June 27, 2006 12:41:14 PM kwolfe
B13 01
6/28/06
OC
BLDG, INSULATION TIME: 17:00
6/28/06
AP
June 28, 2006 8:31:06 AM glsouth
B125 01
4/23/07
JGM
BLDG, FINAL TIME: 17:00
4/23/07
DP
April 23, 2007 12:55:11 PM ncochran.
if you have any questions, call Phil Blackburn 255-6100
04/23/2007 03:43 PM JGM PDA
personel items in the house, no one home
B125 02
4/24
BI
BLDG, FINAL TIME: 17:00
411
April 24, 2007 9:26:56 AM ncochran.
phil Blackburn will meet you out there, call h'imat 255=6100-
(-b(�
-------------------
----
14-7------------
COMMENTS AND NOTES -
g
l
(4/25/2007 Kim Wolfe - Re: Cal lin for CO@ 4303 Whitwick PI Page 1
From: Joe Garcia
To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell...
Date: 4/24/2007 2:51 PM
Subject: Re: Calling for CO@ 4303 Whitwick PI
THIS ONE IS OK. JMG
>>> Nicole Cochran 04/23/07 12:57 PM >>>
Issues?
BP# 06-1213
Thanks!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.aov
Date: 4/24/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1213
Address: 4303 WHITWICK PL
Type
inspection Type Code
Description
p.
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
Loose Or Missing Anchor Bolt Nuts
B115
BLDG, FRAMING
IC
Joist Hangers Needed
B115
BLDG, FRAMING
IC
06/23/2006 03:09 PM OC PDA
B115
BLDG, FRAMING
IC
alt. walls missing.
B115
BLDG, FRAMING
IC
June 27, 2006 12:41:14 PM kwolfe
B125
BLDG, FINAL
IC
04/23/2007 03:43 PM JGM PDA
B125
BLDG, FINAL
IC
personel items in the house, no one home
P125
PLBG, FINAL
IC
September 15, 2006 12:37:16 PM ncochran
P125
PLBG, FINAL
IC
04/23/2007 03:11 PM JGM PDA
P125
PLBG, FINAL
IC
gas test
Page 1
WF0761827 / 001 City of College Station
PAGE 1
REQ. DATE:
04/20/06
04/20/06
13:06:19
LOCATION:
4303 WHITWICK PL
LOC ID:
198080
REQUESTOR:
MAVERICK BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/20/06 SCHED COMPLETION:
04/20/06
********************************************************************************
JOB ORDER RESULT COMVIEIT�TTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
a
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved
4/25/07
184200-2301-0200
4303 WHITWICK PL
COLLEGE STATION TX 77845
CASTLEGATE SEC 3 PH 2
CASTLEGATE SEC 3, PHS 2, BLOCK
1, LOT 20
PLANNED DEVL HOUSING
GREENS PRAIRIE INVESTORS LTD
PHILIP BLACKBURN (MAVERICK)
979 693-2364
06-00001213 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
je4o* X llau�'
BuWding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
e
E`L jFNG PERMIT
CITY OF=COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 06-00001213
Date 4/20/06
Property Address . .
. . . . 4303 WHITWICK PL
Property ID:
184200-2301-0200
R #:
R115366
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 3 PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation . . . . 290000
Owner
Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD PHILIP BLACKBURN
(MAVERICK)
4490 CASTLEGATE DR
MAVERICK BUILDERS
COLLEGE STATION
TX 778453388 208 C SOUTHWEST PKWY EAST
COLLEGE STATION
TX 77840
(979) 693-2364
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3021.00
INTERIOR WALL TYPE
SHEET ROCK
NUMBER OF BATHROOMS
4.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
KW
Permit Fee
1030.00 Plan Check Fee
.00
Issue Date
4/20/06 Valuation . .
. . 290000
Expiration Date
10/17/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
190.00 3.0000
THOU BLDG, VAL 100001-500000
570.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
INTERRUPTERS)
BE PROTECTED BY AN ARC -FAULT CIRCUIT
i
--------------- - - -
BUILDING D
APPLICANT:
$UILDJNG PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001213
Page 2
Date 4/20/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
BUILDING DEP
APPLICANT
ZUILDfNG PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001213
Page 3
Date 4/20/06
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
---------------------- ----- --- -------------
BUILDING DEPT R SEN
APPLICANT:
$UILD,T�NG PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . .
06-00001213 Date
4/20/06
----------------------------------------------------------------------------
Special Notes and Comments
IRC)
RANGE/DRYER DUCT MUST COMPLY
WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS.
CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
Narrow wall bracing to be fully
sheathed with 32" alternate
braced panels.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 1030.00
1030.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1780.00
1780.00 .00
.00
BUILD
APPLI
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
Fa Ofte Use ONy ,
DATE: -{ I I < 16U -
/
APPLICATION # L b - (3-1
WW W.CI.COLLEGGE-STATION.TX.US
ADDRESS/LOCATION:
LOT BLOCK SUBDIVI N r�
BUSINESS/OWNER NAME: �7 Q; r PHONE:
CONTRACTOR/HOMEOWNER: ` r A5 oNE: 2 �O
CONTRACTOR ADDRESS:
ELECTRICIAN: rG/L' f% PLUMBER:'
HVAC: GOOD CENTS (Res ntial only): �J
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATI/ON SWIMMING POOL
DESCRIPTION OF WORK:
1 n _ /.10 n
STRUCTURE USE:
HOMEOWNER ASSOCIATION/AR CTUAL OR D 5P,15N REVIEW COMMITTEE, APPROVAL: S
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ (� TOTAL �}REA: �0HEATED AREA: GGv2
(Cos of Labor d Materials) $�/a6
�D PUBLIC SEWER NUMBER OF BEDROOMS:
- SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:_
SEWER TAP: INTERIOR WALL TYPE:
v � � SI
WATER TAP: EXTERIOR WALL TYPE:
IZE
❑ OTHER TAP: FOUNDATION TYPE:
,{ SIZE
�O TEMP POLE ROOF TYPE:
1 U GARAGE TYPE: SINGLE DOUBLE TRIPLE a ,
\' ATTACHE ZIJ DETAC CAR
SIGNATURE OF APPLICANT: r
+ei,2S Plans Examiner
- SD Lo �.a�l-ins
i�sGPI O SB -I- 3z" AI+�
O �cial Use Only
Vic
Zoning Official
merits:
YES or NO
Energy Code Compliance Information
% Glazing of exterior walls,
/ ✓
Insulation'R value of exterior walls
/3
lation R value of ceilin 1 flat areas
Insu g ( )_
' O f
Insulation R value of ceiling 2 (vaulted areas/no attic)
/
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER
rating
B. H. C .- MAVERICK BUILDERS, INC
208-D SOUTHWEST PKWY. E.
COLLEGE STATION, TX 71840
qovo
'La, �
. (*f/""
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER#
_ /z I
DATE:
q ho /ol*o
BUILDING ADDRESS:
q303
'ick 01cce
I. Foundation Requirements
NA/aj
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
K
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, rade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
(*hrq" OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d' Development Services
Il. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
tJA
III. Stairway Requirements
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening 216 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NA/ K
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N 9bK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NAMXJ
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
Approved subdivision
tO
Plat filed
IOZZN
Floodplain Regulations — Ordinance 1301
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning 6 Development Services
Comments:
J4�L.
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
�i- 20- O
DATE