PREPARED 8/23/06, 12:02:54 INSPECTION TICKET PAGE 14
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/23/06
------------------------------------------------------------------------------------------------
ADDRESS . : 1025 FALLBROOK LOOP SUBDIV: WESTFIELD VILLAGE PH 5
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 005401-0513-0050
APPL NUMBER: 06-00001198 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED" RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100.'1-> 5/04/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/05/06 AP May 4, 2006 8:22:36 AM bkorthauer
B115 1 6/22/06 OC BLDG, FRAMING TIME: 17:00
0
6/22/06 DP June 16, 2006 10:21:09 AM glsouth
Sheetrock Fireplace Chase, Firestopping
Need To Add Windbracing
06/22/2006 02:42 PM OC PDA
"X" strap in garage ceiling.
B115 02 6/26/06 JGM BLDG, FRAMING TIME: 17:00
6/26/06 AP June 26, 2006 10:03:33 AM bkorthauer
B130101 6/28/06 JGM BLDG, INSULATION TIME: 17:00
6/28/06 AP June 28, 2006 11:30:09 AM bkorthauer
B145 01 7/12/06 JGM BLDG, EXT. SHEATHING FASTENER TIME: 17:00
7/12/06 DA July 12, 2006 8:46:48 AM glsouth
07/12/2006 03:15 PM JGM PDA
sheetrock fastener, not ready
B132 01 7/14/06 RH BLDG, SHEETROCK FASTENER TIME: 17:00
7/14/06 AP July 13, 2006 1:30:33 PM bkorthauer
B125 01 We(*
X00-0-C
BLDG, FINAL TIME: 17:00
August 23, 2006 10:09:25 AM kwolfe
-------------------------------------- COMMENTS AND NOTES --------------------------------------
DV-.,,-
Date: 8/23/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1198
Address: 1025 FALLBROOK LOOP
Inspection Result Comments
Sheetrock Fireplace Chase, Firestopping
Need To Add Windbracing
06/22/2006 02:42 PM OC PDA
"X" strap in garage ceiling.
07/12/2006 03:15 PM JGM PDA
sheetrock fastener, not ready
08/14/2006 03:40 PM JGM PDA
light in entry hall not working, light switch in hallway
to front bedrooms no fixture, closet light in second
bedroom needs proper clearance from shelf, lioght in
livingroom not working
08/14/2006 03:37 PM JGM PDA
tmp drain line not connected
Page 1 b
WF0761379 /
001 City of Coll6cr ration
PAGE 1
REQ. DATE:
04/19/06
04/19/06
14:14:18
LOCATION:
1025 FALLBROOK LOOP
LOC ID:
203932
REQUESTOR:
STYLECRAFT BUILDERS, INC ' ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/19/06 SCHED COMPLETION:
04/19/06
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY Cw COTaLEGE STATION
1101 ; TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3`570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number 06-00001198 Date 4/19/06
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
--- Structure Information
Construction Type
Occupancy Type . .
Other struct info
1011111Mwe
1025 FALLBROOK LOOP
005401-0513-0050
RESIDENTIAL, 1 UNIT DETACHED NEW
WESTFIELD VILLAGE PH 5
RESIDENTIAL
PLANNED DEVL HOUSING
99726
Contractor
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
SINGLE FAMILY
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1511.00
INTERIOR WALL TYPE
SHEET ROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
1.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit Fee . . . . 460.00 Plan Check Fee .00
Issue Date . . . . 4/19/06 Valuation . . . . 99726
Expiration Date . . 10/16/06
Qty Unit Charge Per Extension
BASE FEE 260.00
50.00 4.0000 THOU BLDG, VAL 50001-100000 200.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
--------------------------- ----- --- - ---.------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT-
BUILDING PERMIT
CITY 0,K COIrLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Page 2
Application Number . . . . . 06-00001198 Date 4/19/06
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
--------------------------- ------ --- - -- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT_
BUILDING PERMIT
CITY QF COT,LEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00001198 Date 4/19/06
----------------------------------------------------------------------------
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
--------------------------------- ----- ---- ---'---------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY QF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00001198
Date 4/19/06
----------------------------------------------------------------------------
Special Notes and Comments
Engineered Methods
used for
Narrow wall bracing
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
460.00
460.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1210.00
1210.00
.00
.00
-------------------------------------------- ------ -------a----------------
BUILDING DEPT REPRESENTATIVE: •
APPLICANT:
TEMPORARY POLE PERMIT
CITY QF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00001199 Date 4/19/06
Property Address . . . . . . 1025 FALLBROOK LOOP
Property ID: 005401-0513-0050
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/19/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �/ - - - - - • - �- - - - - - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
1 For O/fice use Only
in
APPLICATION FOR BUILDING PERMIT DATE: L( �� O CC REG
CITY OF COLLEGE STATION
APPLICATION #
t* ff 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE #
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning & Deve4ment Servim WWW CSTX.GOV
ADDRESS/LOCATION: 1025 FAL.L'BRooK LOOP
LOT cJ ✓ BLOCK I3 SUBDIVISION WI-STReL.D V ILL AC-jE ✓ SEC/PH 5 �
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Sinale Family Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N�A
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ 0(ol-I2co / TOTAL AREA: 208'1 HEATED AREA: 1511
(Cost of Labor and Materials)
4V OX PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
�X SEWER TAP: 4"
SIZE
X WATER TAP: 3/a"
SIZE
r(,^OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SINGLE
ATTACHED ERE
NUMBER OF BEDROOMS: tj
NUMBER OF BATHROOMS: rL
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE: Siding and/Or Masonry
FOUNDATION TYPE: Slab On Grade
ROOF TYPE:
Composition
DOUBLE 1�a
TRIPLE El
DETACHED F__j
CARPORT
SIGNATURE OF APPLICANT: For St lecraft
*If proposed work involves new commercial constructs or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
06
zigQ ePla nsl Examiner
Zoning Official
Co ents:
S r NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
R13
R30
/
R19
.40
.65
/
R6 /
13
.�
i
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning cr Development Services
PLAN REVIEW/PERMIT NUMBER#
( _
DATE: q / / q/ duo
BUILDING ADDRESS:
oat s- Fall6 0 0
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings (30" exterior, 24" interior unless over 60' long then 30")
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
PJA
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
(*gq"
CITY OF COLLEGE STATION
Planning c5 Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NAT
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
dA
III. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6) inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
NA
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials,
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
1. t
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
V. Electrical Service Requirements
NAWly
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFl circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
Vl. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vlll. Energy Requirements
NA/
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NA/ K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
PA-
4
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
A�- V- h'-oG
PLANS EXAMINER DATE
Permit Number
REScheck Compliance Certificate Checked By/Date
2003 IECC
REScheck Soilware Version 3.6 Release 2
Data filename: S:\ACAD\Archived\Old REScheck\1514-1025 Fallbrook Loop.rck
PROJECT TITLE: Plan #1514
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.15
DATE: 04/04/06
DATE OF PLANS: 04-04-06
PROJECT DESCRIPTION:
Dean
1025 Fallbrook Loop
College Station, Texas
DES IGNER/CONTRACTOR:
Stylecraif Builders Inc.
4090 State Hwy. 6 South
College Station, Texas 77845
COMPLIANCE: Passest
Maximum UA = 609
Your Home UA = 520
14.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Door 1: Solid
Door 2: Glass
SHGC: 0.40
Floor 1: S lab-On-Gradc: Unheated
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-V
U-Factor
JJA
1392
30.0
0.0
49
356
19.0
0.0
19
1464
13.0
0.0
99
198
0.670
133
38
0.500
19
18
0.580
10
183
0.0
191
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 2: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Date —
'1 1
REScheck Inspection Checklist
2003 IECC
REScheck Solware Version 3.6 Release 2
DATE: 04/04/06
PROJECT TITLE: Plan #1514
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor. 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor. 0.500
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.580
Comments:
Floors:
1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
2. Furnace 2: Forced Hot Air, 80 AFUE or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Skylights:
Minimum insulation requirement for skylight shales equal to or greater than 12 inches is R-13.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturers installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals & all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to Rom.
[ ] Supply ducts in unconditioned spaces must be insulated to R-6.
[ ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
[ ] Where exterior walls are used as plenums, the wall must be insulated to R-8.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required far each separate HVAC system. A manual or automatic means to
partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
ofthe heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ) HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness
in Inches
by Pi ep Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature (Fl
170-180
14P to 1" Un to 1.25"
0.5 1.0
1.5" to
1.5
2.0" Over 2"
2.0
140-169 _
0.5 0.5
1.0
1.5
100-139
0.5 0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness
in Inches by Pipe
Sizes
Piping System Types
Ran
2" Runouts
1" and
Less 1.25" to 2" 2.5 , to 4„
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (fbr fed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Area Calculator:
Assembly Type
Description
m�
..
o�■�■
•, ,
afflowl
M.,
[more
M-I
Window Area Total: 180.00
04/04/06 14:33:12 1 /1
Area Calculator:
Description
Opaque door solid
Door Area Total: 55.56
04/04/06 14:33:12 1 /1
Area Calculator:
AssemblyEll
Comments/Description
Ceiling Area Total: 1514.00
04/04/06 14:33:12 1 /1
Area Calculator:
Assembly Type
Comments/Description
Mw
... - ..■�■�®
Exterior Wall Area Total: 1437.33
04/04/06 14:33:12 1 /1
Area Calculator:
Assembly Type
Comments/Description
Floor Area Total: 0.00
04/04/06 14:33:13 . 1 /1