Loading...
HomeMy WebLinkAboutRES2006-01198, 06-1199ole- liciv 04—Itgq Ck^41� c OPendaflemr /3 Esselte R 7521/3 10% P4 i PREPARED 8/23/06, 12:02:54 INSPECTION TICKET PAGE 14 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/23/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 1025 FALLBROOK LOOP SUBDIV: WESTFIELD VILLAGE PH 5 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0513-0050 APPL NUMBER: 06-00001198 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED" RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100.'1-> 5/04/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/05/06 AP May 4, 2006 8:22:36 AM bkorthauer B115 1 6/22/06 OC BLDG, FRAMING TIME: 17:00 0 6/22/06 DP June 16, 2006 10:21:09 AM glsouth Sheetrock Fireplace Chase, Firestopping Need To Add Windbracing 06/22/2006 02:42 PM OC PDA "X" strap in garage ceiling. B115 02 6/26/06 JGM BLDG, FRAMING TIME: 17:00 6/26/06 AP June 26, 2006 10:03:33 AM bkorthauer B130101 6/28/06 JGM BLDG, INSULATION TIME: 17:00 6/28/06 AP June 28, 2006 11:30:09 AM bkorthauer B145 01 7/12/06 JGM BLDG, EXT. SHEATHING FASTENER TIME: 17:00 7/12/06 DA July 12, 2006 8:46:48 AM glsouth 07/12/2006 03:15 PM JGM PDA sheetrock fastener, not ready B132 01 7/14/06 RH BLDG, SHEETROCK FASTENER TIME: 17:00 7/14/06 AP July 13, 2006 1:30:33 PM bkorthauer B125 01 We(* X00-0-C BLDG, FINAL TIME: 17:00 August 23, 2006 10:09:25 AM kwolfe -------------------------------------- COMMENTS AND NOTES -------------------------------------- DV-.,,- Date: 8/23/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1198 Address: 1025 FALLBROOK LOOP Inspection Result Comments Sheetrock Fireplace Chase, Firestopping Need To Add Windbracing 06/22/2006 02:42 PM OC PDA "X" strap in garage ceiling. 07/12/2006 03:15 PM JGM PDA sheetrock fastener, not ready 08/14/2006 03:40 PM JGM PDA light in entry hall not working, light switch in hallway to front bedrooms no fixture, closet light in second bedroom needs proper clearance from shelf, lioght in livingroom not working 08/14/2006 03:37 PM JGM PDA tmp drain line not connected Page 1 b WF0761379 / 001 City of Coll6cr ration PAGE 1 REQ. DATE: 04/19/06 04/19/06 14:14:18 LOCATION: 1025 FALLBROOK LOOP LOC ID: 203932 REQUESTOR: STYLECRAFT BUILDERS, INC ' ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/19/06 SCHED COMPLETION: 04/19/06 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT CITY Cw COTaLEGE STATION 1101 ; TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3`570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number 06-00001198 Date 4/19/06 Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner --- Structure Information Construction Type Occupancy Type . . Other struct info 1011111Mwe 1025 FALLBROOK LOOP 005401-0513-0050 RESIDENTIAL, 1 UNIT DETACHED NEW WESTFIELD VILLAGE PH 5 RESIDENTIAL PLANNED DEVL HOUSING 99726 Contractor STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 SINGLE FAMILY COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1511.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 460.00 Plan Check Fee .00 Issue Date . . . . 4/19/06 Valuation . . . . 99726 Expiration Date . . 10/16/06 Qty Unit Charge Per Extension BASE FEE 260.00 50.00 4.0000 THOU BLDG, VAL 50001-100000 200.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211 --------------------------- ----- --- - ---.------------ BUILDING DEPT REPRESENTATIVE: APPLICANT- BUILDING PERMIT CITY 0,K COIrLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 2 Application Number . . . . . 06-00001198 Date 4/19/06 ---------------------------------------------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO --------------------------- ------ --- - -- ------------- BUILDING DEPT REPRESENTATIVE: APPLICANT_ BUILDING PERMIT CITY QF COT,LEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00001198 Date 4/19/06 ---------------------------------------------------------------------------- Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES --------------------------------- ----- ---- ---'--------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY QF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001198 Date 4/19/06 ---------------------------------------------------------------------------- Special Notes and Comments Engineered Methods used for Narrow wall bracing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 460.00 460.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1210.00 1210.00 .00 .00 -------------------------------------------- ------ -------a---------------- BUILDING DEPT REPRESENTATIVE: • APPLICANT: TEMPORARY POLE PERMIT CITY QF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001199 Date 4/19/06 Property Address . . . . . . 1025 FALLBROOK LOOP Property ID: 005401-0513-0050 R #. Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 5 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc KW Permit Fee . . . . 20.00 Issue Date . . . . 4/19/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �/ - - - - - • - �- - - - - - - - - - - BUILDING DEPT REPRESENTATIVE: APPLICANT: 1 For O/fice use Only in APPLICATION FOR BUILDING PERMIT DATE: L( �� O CC REG CITY OF COLLEGE STATION APPLICATION # t* ff 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE # CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning & Deve4ment Servim WWW CSTX.GOV ADDRESS/LOCATION: 1025 FAL.L'BRooK LOOP LOT cJ ✓ BLOCK I3 SUBDIVISION WI-STReL.D V ILL AC-jE ✓ SEC/PH 5 � BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N�A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 0(ol-I2co / TOTAL AREA: 208'1 HEATED AREA: 1511 (Cost of Labor and Materials) 4V OX PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM �X SEWER TAP: 4" SIZE X WATER TAP: 3/a" SIZE r(,^OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SINGLE ATTACHED ERE NUMBER OF BEDROOMS: tj NUMBER OF BATHROOMS: rL INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/Or Masonry FOUNDATION TYPE: Slab On Grade ROOF TYPE: Composition DOUBLE 1�a TRIPLE El DETACHED F__j CARPORT SIGNATURE OF APPLICANT: For St lecraft *If proposed work involves new commercial constructs or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only 06 zigQ ePla nsl Examiner Zoning Official Co ents: S r NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating R13 R30 / R19 .40 .65 / R6 / 13 .� i PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning cr Development Services PLAN REVIEW/PERMIT NUMBER# ( _ DATE: q / / q/ duo BUILDING ADDRESS: oat s- Fall6 0 0 I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings (30" exterior, 24" interior unless over 60' long then 30") 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated PJA II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. (*gq" CITY OF COLLEGE STATION Planning c5 Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NAT 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes dA III. Stairway Requirements K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6) inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) NA A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials, C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal 1. t PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services V. Electrical Service Requirements NAWly A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFl circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location Vl. Plumbing Requirements NA/ A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vlll. Energy Requirements NA/ A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NA/ K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side (intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required PA- 4 CITY OF COLLEGE STATION Planning & Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS A�- V- h'-oG PLANS EXAMINER DATE Permit Number REScheck Compliance Certificate Checked By/Date 2003 IECC REScheck Soilware Version 3.6 Release 2 Data filename: S:\ACAD\Archived\Old REScheck\1514-1025 Fallbrook Loop.rck PROJECT TITLE: Plan #1514 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.15 DATE: 04/04/06 DATE OF PLANS: 04-04-06 PROJECT DESCRIPTION: Dean 1025 Fallbrook Loop College Station, Texas DES IGNER/CONTRACTOR: Stylecraif Builders Inc. 4090 State Hwy. 6 South College Station, Texas 77845 COMPLIANCE: Passest Maximum UA = 609 Your Home UA = 520 14.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: S lab-On-Gradc: Unheated Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-V U-Factor JJA 1392 30.0 0.0 49 356 19.0 0.0 19 1464 13.0 0.0 99 198 0.670 133 38 0.500 19 18 0.580 10 183 0.0 191 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Date — '1 1 REScheck Inspection Checklist 2003 IECC REScheck Solware Version 3.6 Release 2 DATE: 04/04/06 PROJECT TITLE: Plan #1514 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor. 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor. 0.500 Comments: [ ] 2. Door 2: Glass, U-factor: 0.580 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: Minimum insulation requirement for skylight shales equal to or greater than 12 inches is R-13. Materials Identification: Materials and equipment must be installed in accordance with the manufacturers installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals & all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] Return ducts in unconditioned attics or outside the building must be insulated to Rom. [ ] Supply ducts in unconditioned spaces must be insulated to R-6. [ ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. [ ] Where exterior walls are used as plenums, the wall must be insulated to R-8. Insulation is not required on return ducts in basements. Duct Construction: [ ] Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required far each separate HVAC system. A manual or automatic means to partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ) HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pi ep Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature (Fl 170-180 14P to 1" Un to 1.25" 0.5 1.0 1.5" to 1.5 2.0" Over 2" 2.0 140-169 _ 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ran 2" Runouts 1" and Less 1.25" to 2" 2.5 , to 4„ Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (fbr fed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Assembly Type Description m� .. o�■�■ •, , afflowl M., [more M-I Window Area Total: 180.00 04/04/06 14:33:12 1 /1 Area Calculator: Description Opaque door solid Door Area Total: 55.56 04/04/06 14:33:12 1 /1 Area Calculator: AssemblyEll Comments/Description Ceiling Area Total: 1514.00 04/04/06 14:33:12 1 /1 Area Calculator: Assembly Type Comments/Description Mw ... - ..■�■�® Exterior Wall Area Total: 1437.33 04/04/06 14:33:12 1 /1 Area Calculator: Assembly Type Comments/Description Floor Area Total: 0.00 04/04/06 14:33:13 . 1 /1