HomeMy WebLinkAboutRES2006-01194, 06-1195a.-nqq off, - I t95 (4") s *PendaftexP' ` aEsselte R 7521/3 10% M PREPARED 8/28/06, 7:49:56 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/25/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 921 CRESTED POINT DR SUBDIV: WESTFIELD VILLAGE PH 4 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0408-0100 APPL NUMBER: 06-00001194 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/10/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/10/06 AP May 10, 2006 8:45:54 AM kwolfe Strings On Setbacks O.K. Slab Ground Installed B115 01 7/07/06 JGM BLDG, FRAMING TIME: 17:00 7/07/06 AE July 6, 2006 2:40:50 PM glsouth 07/07/2006 12:01 PM JGM PDA need to draftstop chase by ac return B130 0 7/12/06 JGM BLDG, INSULATION TIME: 17:00 7/12/06 AP July 12, 2006 3:02:48 PM glsouth B132 0 7/17/06 OC BLDG, SHEETROCK FASTENER TIME: 17:00 7/17/06 AP July 14, 2006 1:35:18 PM kwolfe B125 8/2 /06. B BLDG, FINAL TIME: 17:00 August 25, 2006 2:22:21 PM bkorthauer -----'------------------------------ COMMENTS AND NOTES -------------------------------------- A � Date: 8/28/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1194 Address: 921 CRESTED POINT DR Type Inspection Type Code Description st ins Inspection Result Comments 6100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC 07/07/2006 12:01 PM JGM PDA B115 BLDG, FRAMING IC need to draftstop chase by ac return Ell ELEC, ROUGH IN IC 07/07/2006 12:00 PM JGM PDA E110 ELEC, ROUGH IN IC need clamp on slab ground, need proper clearance on smoke Ell ELEC, ROUGH IN IC detector in front bedroom Page 1 WF0780204 / 001 City of College Station PAGE 1 REQ. DATE: 05/26/06 I 05/26/06 15:26:02 LOCATION: 921 CRESTED POINT DR LOC ID: 203792 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/26/06 SCHED COMPLETION: 05/26/06 ******************************************************************************** JOB ORDER RESULT COMIMTS WF0761376 / 001 City of College Station PAGE 1 f} REQ. DATE: 04/19/06 `, 04/19/06 14:11:25 LOCATION: 921 CRESTED POINT DR LOC ID: 203792 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/19/06 SCHED COMPLETION: 04/19/06 ******************************************************************************** JOB ORDER RESULT COMENTS BUILDING PERMIT CITY OFUOQEGE _ATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ------------------------------------ (979)764-3570. FAX: (979)764-3496 ---------------------------------------- t. Application Number . . . . . 0'6-00001194 Date 4/19/06 Property Address . . . . . . 9;21 CRESTED POINT DR Property ID: 005401-0408-0100 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 80388 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 1.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1218.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc KW Permit Fee . . . . 384.00 Plan Check Fee .00 Issue Date . . . . 4/19/06 Valuation . . . . 80388 Expiration Date . . 10/16/06 Qty Unit Charge Per Extension BASE FEE 260.00 31.00 4.0000 THOU BLDG, VAL 50001-100000 124.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM R UGH -FRAMED SIZE 22" --- ---- ------------ --------------------- ----- --- --- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF, COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00001194 Date 4/19/06 ----------------------------------------------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO -- -------------------------------------------- ----- --- - -- ----------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF; COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001194 Page 3 Date 4/19/06 Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------- ----�-- - -- ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF, COLI;EGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001194 Date 4/19/06 ---------------------------------------------------------------------------- Special Notes and Comments Engineered Methods used for Narrow wall bracing. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 384.00 384.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1134.00 1134.00 .00 .00 --------------------------------------------------�.J• ---------- BUILDING DEPT REPRESENTATIVE: APPLICAN TEMPORARY POLE PERMIT CITY OF, COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001195 Date 4/19/06 Property Address . . . . . . 921 CRESTED POINT DR Property ID: 005401-0408-0100 R #. Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date 4/19/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 --------------------------- Fee summary ------------------------------------------------ Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------------------------------- -------------- BUILDING DEPT REPRESENTATIVE: Ap&a,4 APPLICANT: Fa Onke use Only APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning 6-Da IvpmentSm"icet WWW.CSTX.GOV DATE: LL 1 1 + 1 TO REG APPLICATION # �II O TEMP POLE # a#- I L 1 S ADDRESS/LOCATION: 0121 C.RP-STEp tLlKTE-- LOT 10 BLOCK '9 V1 SUBDIVISION WEgTFlE= n VILLAC-A F SEC/PH BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ' SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ gQ'g TOTAL AREA: 11o2_+ HEATED AREA: 12-lq (Cost of Labor and Materials) 3t4 �X PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM �X SEWER TAP: 4" �X WATER TAP: SIZE :V4. SIZE ❑ OTHER TAP: SIZE �X TEMP POLE GARAGE TYPE: SINGLE 1`" I ATTACHED XI NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE: 3 2 Sheet Rock Siding and/or Masonry Slab on Grade ROOF TYPE: Composition DOUBLE F-1 TRIPLE DETACHED F__] CARPORT a SIGNATURE OF APPLICANT: For St lecraft *If proposed work involves new mercial construction br4acade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only T� y�iy-o 6 / Plans Examiner l� W1 A /30e-0- C4jk5 Zoning Official Comments: S rNO Energy; Code Compliance Information . �.. % Glazing of exterior walls 1 % Insulation R value of exterior walls R13 e*' Insulation R value of ceiling 1 (flat areas) R30,` Insulation R value of ceiling 2 (vaulted areas/no attic) R19-' Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER Rating 13 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning ci Development Services PLAN REVIEW/PERMIT NUMBER# G v DATE: y h ti /o BUILDING ADDRESS: qzl A64 &t.. I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3_ Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA'r 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" or S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements&PK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated on plans) OK A. Hearth extensions Ir 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning ear Development Services V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NAOQW Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required �, I N 4 CITY OF COLLEGE STATION Planning er Development Services Comments: PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS /q, of DATE R EScheck Compliance Certificate 2003 IECC REScheck So$ware Version 3.6 Release 2 Data filename: S:\ACAD\Archived\Old REScheck\1218 921 Crested Point.rck PROJECT TITLE: PLAN #1218 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.12 DATE: 03/30/06 DATE OF PLANS: 03/30/06 PROJECT DESCRIPTION: Sexton 921 Crested Point College Station, Texas DESIGNER/CONTRACT OR: Stylecrali Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 iCOMPLIA_NCE:, Passes Maximum UA = 354 Your Home UA = 280 20.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Wall 2: Wood Frame, 16" o.c. Window 4: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 3: Glass SHGC: 0.40 Door 5: Solid Floor 1: Unheated Insulation depth: 0.0' Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter -ValueR Value U-Factor SJ$ 1161 30.0 0.0 41 1240 13.0 0.0 87 131 0.650 85 20 0.500 10 33 0.900 30 26 0.0 27 L .! Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/DesignerQ� Date3-3 cO -0(0 �� O REScheck Inspection Checklist 2003 IWC REScheck Soffware Version 3.6 Release 2 DATE: 03/30/06 PROJECT TITLE: PLAN #1218 Bldg. Dept. Use Ceilings: [ ] 1 1. Ceiling l: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor. 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 3: Glass, U-factor 0.500 Comments: [ ] 2. Door 5: Solid, U-factor. 0.900 Comments: Floors: [ ] 1. Floor 1: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number [ ] 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type 1C rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a Area Calculator: ■ �.. ..Assembly Type =01MIMMOMM Description': �■ • , ., - .. Off■ . , ■ . „ • „ ® , . , � Window Area Total: 131.00 03/30/06 14:48:05 1 /1 Area Calculator: Description WMIFIGIGJ MMIMIMMEmmmasonite Opaque door solid Door Area Total: 71.11 03/30/0614:48:05 - 1/1 Area Calculator: Assembly Type Comments/Description Ceiling Area Total: 1161.00 03/30/06 14:48:05 1 /1 Area Calculator: Comments/Description Exterior Wall Area Total: 1240.00 03/30/06 14:48:05 1 /1 Area Calculator: Assembly Type Comments/Description m �■�■��IM ® �■�■�� ED ISM - En■�■�� Floor Area Total: 0.00 03/30/0614:48:06 1 /1