PREPARED 8/28/06, 7:49:56 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/25/06
------------------------------------------------------------------------------------------------
ADDRESS . : 921 CRESTED POINT DR SUBDIV: WESTFIELD VILLAGE PH 4
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 005401-0408-0100
APPL NUMBER: 06-00001194 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/10/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/10/06 AP May 10, 2006 8:45:54 AM kwolfe
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 7/07/06 JGM BLDG, FRAMING TIME: 17:00
7/07/06 AE July 6, 2006 2:40:50 PM glsouth
07/07/2006 12:01 PM JGM PDA
need to draftstop chase by ac return
B130 0 7/12/06 JGM BLDG, INSULATION TIME: 17:00
7/12/06 AP July 12, 2006 3:02:48 PM glsouth
B132 0 7/17/06 OC BLDG, SHEETROCK FASTENER TIME: 17:00
7/17/06 AP July 14, 2006 1:35:18 PM kwolfe
B125 8/2 /06. B BLDG, FINAL TIME: 17:00
August 25, 2006 2:22:21 PM bkorthauer
-----'------------------------------ COMMENTS AND NOTES --------------------------------------
A �
Date: 8/28/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1194
Address: 921 CRESTED POINT DR
Type
Inspection Type Code
Description
st ins
Inspection Result Comments
6100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
07/07/2006 12:01 PM JGM PDA
B115
BLDG, FRAMING
IC
need to draftstop chase by ac return
Ell
ELEC, ROUGH IN
IC
07/07/2006 12:00 PM JGM PDA
E110
ELEC, ROUGH IN
IC
need clamp on slab ground, need proper clearance on
smoke
Ell
ELEC, ROUGH IN
IC
detector in front bedroom
Page 1
WF0780204 / 001 City of College Station
PAGE 1
REQ. DATE:
05/26/06
I
05/26/06
15:26:02
LOCATION:
921 CRESTED
POINT DR
LOC ID:
203792
REQUESTOR:
STYLECRAFT
BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE
AUTH. USER: KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW
UTILITY ACCT SET
READY
SCHED START:
05/26/06
SCHED COMPLETION:
05/26/06
********************************************************************************
JOB ORDER RESULT COMIMTS
WF0761376
/ 001 City of College
Station
PAGE 1
f}
REQ. DATE:
04/19/06 `,
04/19/06
14:11:25
LOCATION:
921 CRESTED POINT DR
LOC ID:
203792
REQUESTOR:
STYLECRAFT BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START: 04/19/06 SCHED
COMPLETION:
04/19/06
********************************************************************************
JOB ORDER
RESULT COMENTS
BUILDING PERMIT
CITY OFUOQEGE _ATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
------------------------------------
(979)764-3570. FAX: (979)764-3496
----------------------------------------
t.
Application Number
. . . . . 0'6-00001194
Date 4/19/06
Property Address
. . . . . . 9;21 CRESTED POINT DR
Property ID:
005401-0408-0100
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . . WESTFIELD VILLAGE PH 4
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 80388
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information 000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
1.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1218.00
INTERIOR WALL TYPE
SHEET ROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
KW
Permit Fee . . .
. 384.00 Plan Check Fee
.00
Issue Date . . .
. 4/19/06 Valuation . .
. . 80388
Expiration Date .
. 10/16/06
Qty Unit Charge Per Extension
BASE FEE 260.00
31.00 4.0000 THOU BLDG, VAL 50001-100000 124.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM R UGH -FRAMED SIZE 22"
--- ---- ------------
--------------------- ----- --- ---
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF, COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00001194 Date 4/19/06
-----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
-- -------------------------------------------- ----- --- - -- -----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF; COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001194
Page 3
Date 4/19/06
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
---------------------------- ----�-- - -- ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF, COLI;EGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00001194
Date 4/19/06
----------------------------------------------------------------------------
Special Notes and Comments
Engineered Methods
used for
Narrow wall bracing.
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
----------
384.00
384.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1134.00
1134.00
.00
.00
--------------------------------------------------�.J• ----------
BUILDING DEPT REPRESENTATIVE:
APPLICAN
TEMPORARY POLE PERMIT
CITY OF, COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00001195 Date 4/19/06
Property Address . . . . . . 921 CRESTED POINT DR
Property ID: 005401-0408-0100
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date
4/19/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
---------------------------
Fee summary
------------------------------------------------
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------------------------------------- --------------
BUILDING DEPT REPRESENTATIVE: Ap&a,4
APPLICANT:
Fa Onke use Only
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning 6-Da IvpmentSm"icet WWW.CSTX.GOV
DATE: LL 1 1 + 1 TO REG
APPLICATION # �II O
TEMP POLE # a#- I L 1 S
ADDRESS/LOCATION: 0121 C.RP-STEp tLlKTE--
LOT 10 BLOCK '9 V1 SUBDIVISION WEgTFlE= n VILLAC-A F SEC/PH
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ' SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Sinale Familv Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �A
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ gQ'g TOTAL AREA: 11o2_+ HEATED AREA: 12-lq
(Cost of Labor and Materials)
3t4
�X PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
�X SEWER TAP:
4"
�X WATER TAP:
SIZE
:V4.
SIZE
❑ OTHER TAP:
SIZE
�X TEMP POLE
GARAGE TYPE:
SINGLE
1`" I
ATTACHED XI
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
3
2
Sheet Rock
Siding and/or Masonry
Slab on Grade
ROOF TYPE: Composition
DOUBLE F-1 TRIPLE
DETACHED F__] CARPORT a
SIGNATURE OF APPLICANT: For St lecraft
*If proposed work involves new mercial construction br4acade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
T� y�iy-o 6
/ Plans Examiner
l� W1 A
/30e-0- C4jk5
Zoning Official
Comments:
S rNO
Energy; Code Compliance Information
. �..
% Glazing of exterior walls
1 %
Insulation R value of exterior walls
R13 e*'
Insulation R value of ceiling 1 (flat areas)
R30,`
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19-'
Glazing SHGC
.40
Glazing U-Factor
.65
R value of ductwork
R6
A/C SEER Rating
13
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning ci Development Services
PLAN REVIEW/PERMIT NUMBER# G v
DATE: y h ti /o
BUILDING ADDRESS: qzl
A64 &t..
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3_ Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA'r
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
or
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements&PK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated on plans)
OK
A. Hearth extensions
Ir
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning ear Development Services
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NAOQW
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
�,
I N
4
CITY OF COLLEGE STATION
Planning er Development Services
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
/q, of
DATE
R EScheck Compliance Certificate
2003 IECC
REScheck So$ware Version 3.6 Release 2
Data filename: S:\ACAD\Archived\Old REScheck\1218 921 Crested Point.rck
PROJECT TITLE: PLAN #1218
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.12
DATE: 03/30/06
DATE OF PLANS: 03/30/06
PROJECT DESCRIPTION:
Sexton
921 Crested Point
College Station, Texas
DESIGNER/CONTRACT OR:
Stylecrali Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
iCOMPLIA_NCE:, Passes
Maximum UA = 354
Your Home UA = 280
20.9% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 2: Wood Frame, 16" o.c.
Window 4: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Door 3: Glass
SHGC: 0.40
Door 5: Solid
Floor 1: Unheated
Insulation depth: 0.0'
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
-ValueR
Value
U-Factor
SJ$
1161
30.0
0.0
41
1240
13.0
0.0
87
131
0.650
85
20
0.500
10
33
0.900
30
26
0.0
27
L
.!
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/DesignerQ� Date3-3 cO -0(0
�� O
REScheck Inspection Checklist
2003 IWC
REScheck Soffware Version 3.6 Release 2
DATE: 03/30/06
PROJECT TITLE: PLAN #1218
Bldg.
Dept.
Use
Ceilings:
[ ] 1 1. Ceiling l: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor. 0.650
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 3: Glass, U-factor 0.500
Comments:
[ ] 2. Door 5: Solid, U-factor. 0.900
Comments:
Floors:
[ ] 1. Floor 1: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
[ ] 2. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type 1C rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
Area Calculator:
■
�..
..Assembly
Type
=01MIMMOMM
Description':
�■
• , .,
- ..
Off■
. ,
■
. „
• „
®
, . ,
�
Window Area Total: 131.00
03/30/06 14:48:05 1 /1
Area Calculator:
Description
WMIFIGIGJ
MMIMIMMEmmmasonite
Opaque door solid
Door Area Total: 71.11
03/30/0614:48:05 - 1/1
Area Calculator:
Assembly Type
Comments/Description
Ceiling Area Total: 1161.00
03/30/06 14:48:05 1 /1
Area Calculator:
Comments/Description
Exterior Wall Area Total: 1240.00
03/30/06 14:48:05 1 /1
Area Calculator:
Assembly Type
Comments/Description
m
�■�■��IM
®
�■�■��
ED
ISM
-
En■�■��
Floor Area Total: 0.00
03/30/0614:48:06 1 /1