PREPARED 7/25/06, 7:57:24 INSPECTION TICKET PAGE 17
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/25/06
------------------------------------------------------------------------------------------------
ADDRESS . : 130 STERLING ST SUBDIV: RICHARDS
CONTRACTOR JOE COURTNEY PHONE (979) 774-8955
OWNER . . PHONE
PARCEL . . 542500-0020-0060
APPL NUMBER: 06-00001185 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/27/06 DS BLDG, FOUNDATION -SLAB TIME: 17:00
4/27/06 AP April 27, 2006 9:28:18 AM bkorthauer
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 6/02/06 RH BLDG, FRAMING TIME: 17:00
6/02/06 AE June 2, 2006 11:01:03 AM kwolfe
06/02/2006 03:48 PM RH PDA
Need anchors at ends and splices.
B130 01 6/07/06 DS BLDG, INSULATION TIME: 17:00
6/07/06 AP June 6, 2006 4:16:30 PM bkorthauer
B1 5 O1 7/2,-40 BI BLDG, FINAL TIME: 17:00
3 �cn 5 July 24, 2006 2:50:34 PM kwolfe
-----------------------------hf----- COMMENTS AND NOTES --------------------------------------
/Y
w
Date: 7/25/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1185
Address: 130 STERLING ST
Insp.
Inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/02/2006 03:48 PM RH PDA
B115
BLDG, FRAMING
IC
Need anchors at ends and splices.
P100
PLBG, ROUGH IN
IC
04/25/2006 10:03 AM JGM PDA
P100
PLBG, ROUGH IN
IC
test not holding
P100
PLBG, ROUGH IN
IC
April 26, 2006 8:46:37 AM kwolfe
P125
PLBG, FINAL
IC
All Electric No Gas
Page 1
WF0773199 / 001 City of College Station PAGE 1
REQ. DATE: 05/15/06 05/15/06 14:35:17
LOCATION: 130 STERLING ST LOC ID: 202890
REQUESTOR: JOE COURTNEY HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/15/06 SCHED COMPLETION: 05/15/06
********************************************************************************
JOB ORDER RESULT CODDIENTS
WF0775130 / 001 City of College Station PAGE 1
REQ. DATE: 05/17/06 05/17/06 13:31:54
LOCATION: 130 STERLING ST LOC ID: 202890
REQUESTOR: JOE COURTNEY HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
WATER BOAR
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/17/06 SCHED COMPLETION: 05/17/06
********************************************************************************
JOB ORDER RESULT COMYIK TPS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I-F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved
7/25/06
542500-0020-0060
130 STERLING ST
COLLEGE STATION TX 77840
RICHARDS
RICHARDS SUBDIVISION-HAMPTON
ESTATES
LOT 6
SINGLE FAMILY RESIDENTIAL
JOE COURTNEY
979 774-8955
06-00001185 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Buil ing Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING -PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570-'-FS: (979) 764-3496
-------------------------------------------------------------------------
Application Number . . . . . 06-00001185 Date 4/18/06
Property Address . . . . . . 130 STERLING ST
Property ID: 542500',,0020-0060
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . RICHARDS
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 96690
Owner Contractor
------------------------ ------------------------
JOE COURTNEY
P.O. BOX 4043
BRYAN TX 77803
(979) 774-8955
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 1465.00
INTERIOR WALL TYPE SHEET ROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 285.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . BK
Permit Fee . . . . 448.00 Plan Check Fee .00
Issue Date . . . . 4/18/06 Valuation . . . . 96690
Expiration Date . . 10/15/06
Qty Unit Charge Per Extension
BASE FEE 260.00
47.00 4.0000 THOU BLDG, VAL 50001-100000 188.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQU PMENT AND WALKWAY
----------------------------- ----------- ---- Ad- - -- 0-060- -----
BUILDING DEPT REP � NT TIVE:/ II
APPLICANT: Q ),
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 1 FATX: (979) 764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 06-00001185 Date 4/18/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For Th's Plan
--------------------------------------------- -�---- - - - - --
----- --- ----
BUILDING DEPT REP ESE VE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 • FAQ: (979)764-3496
Application Number . . . . . 06-00001185
Page 3
Date 4/18/06
Special Notes and Comments
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow wall bracing Prescriptive Methods of OSB and
Alternate Braced panel
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 448.00 448.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 448.00 448.00 .00 .00
---- ---------------------- ------ ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 • FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00001216 Date 4/18/06
130 STERLING ST
542500-0020-0060
TEMP POLE
RICHARDS
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
JOE COURTNEY
P.O. BOX 4043
BRYAN
TX 77803
(979) 774-8955
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/18/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------------------------------- -----------------
BUILDING DEPT REPRESSENNTTATIVE:
APPLICANT:C�.I.... O ��
L� �
(*hr""
CITY OF COLLEGE STATION
Planning & Dewtopment.Servinr
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE"STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRESS/LOCATION: NO
For O/Loe Use Only
DATE: t I R�E/G
APPLICATION
TEMP POLE #
LOT __�_zBLOCK ____j / SUBDIVISION {-teU 4DS <, a2j>1k SjD J --- SEC/PH
BUSINESS/OWNER NAME: HAKP(uNP ONE:
CONTRACTOR/HOMEOWNER: j oS Coulz: Uuc 'i UofY6' taC• PHONE: _14—_ yss
CONTRACTOR ADDRESS: P.0, 6bx- �Yd , `fS(. 17&S
ELECTRICIAN: b-b apC- e, PLUMBER: %. W-( FWdA)0&
HVAC: f kAAA:QVr_ S eNCZS GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE
LOCATION
RE -ROOF
ADDITION
MOVING
SHELL ONLY
DEMOLITION (Asbestos Survey)
NEW CONSTRUCTION '
SLAB ONLY
DUPLEX (Landscape Plans
REMODEL/RENOVATION*
SWIMMING POOL
Required)
DESCRIPTION OF WORK: BULL p
NW 'S W(A16' J. GIUY jZ19Q06
,6
STRUCTURE USE: �E�lDla
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: )JA
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ_
VALUATION: $
i88
TOTAL AREA: 14 5
HEATED AREA: A5 Sr -
(Cost of Labor and Materials
LjgC)
PUBLIC SEWER
t6 #
NUMBER OF BEDROOMS:^
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
j
SEWER TAP:
11
INTERIOR WALL TYPE:
5(UD I &iP. BD.
Ef WATER TAP:
SIZE
3 11
EXTERIOR WALL TYPE:
" 4 SZUD wI mck vam
SIZE
OTHER TAP:
FOUNDATION TYPE:
�-j 00 '('V0151
TEMP POLE
SIZE
ROOF TYPE:
l;04, f(AjlvLLf
GARAGE TYPE: SINGLE DOUBLE TRIPLE
ATTACHED Ea ,DETACHER CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new corn mer i I con 4tru 6tion or facade improvements%renovations to an existing
commercial property, building elevations are required. Official Use Only
71. /o p() ments:
YES r NO
PPlans . miner Zoning Official
• 1
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls 13�
Insulation R value of ceiling 1 (flat areas) 3o
Insulation R value of ceiling 2 (vaulted areas/no attic) 04
Glazing SHGC
Glazing U-Factor , 50
R value of ductwork &
A/C SEER Rating 13 ..,/
.wJ
1
t `
CITY OF COLLEGE STATION
Planning 6-Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# �� _ I �� DATE: //g /06
BUILDING ADDRESS: / 30
I. Foundation Requirements
NAKAV-
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier la out shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
N
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
(*OF""
CITY OF COLLEGE STATION
Planning cs Dtvtlopmtnt Strvictt
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
,^
wT
III. Stairway Requirements
N OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow ed e
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d Development Services
FW
V. Electrical Service Requirements
NAJOV-
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N K
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/ K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements - Ordinance 850
NflfOIK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
AJPT
Street Ordinance Requirements
NAI
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations - Ordinance 690
JO
Approved subdivision
Plat filed
Floodplain Regulations - Ordinance 1301
Does not block any water course or divert any flow
Elevation certificate if required
N
(*hr""
CITY OF COLLEGE STATION
Planning c ' Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
--/ -a6
PLANS EXAMINER DATE