Loading...
HomeMy WebLinkAboutRES2006-01182, 06-1215PREPARED 7/25/06, 7:57:24 INSPECTION TICKET PAGE 15 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/25/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 126 STERLING ST SUBDIV: RICHARDS CONTRACTOR JOE COURTNEY PHONE (979) 774-8955 OWNER . . PHONE PARCEL . . 542500-0020-0040 APPL NUMBER: 06-00001182 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/25/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/25/06 AP April 24, 2006 9:00:48 AM kwolfe Tuesday PM Strings On Setbacks O.K. Slab Ground Installed B115 01 6/01/06 BI BLDG, FRAMING TIME: 17:00 6/01/06 CA June 1, 2006 9:21:10 AM glsouth June 1, 2006 9:21:58 AM glsouth B115 02 6/02/06 RH BLDG, FRAMING TIME: 17:00 6/02/06 AE June 2, 2006 11:00:30 AM kwolfe 06/02/2006 03:16 PM RH PDA Need anchors at ends and splices. B130 01 6/07/06 DS BLDG, INSULATION TIME: 17:00 6/07/06 AP June 6, 2006 4:15:54 PM bkorthauer B125 01 � 7 �/�6 BJ.� � BLDG, FINAL TIME: 17:00 / .5 July 24, 2006 2:51:34 PM kwolfe ---------------------) W- ------- COMMENTS AND NOTES-------------------------------------- Date: 7/25/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1182 Address: 126 STERLING ST Insp. inspection Type Code Description p. Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC June 1, 2006 9:21:58 AM glsouth B115 BLDG, FRAMING IC 06/02/2006 03:16 PM RH PDA B115 BLDG, FRAMING IC Need anchors at ends and splices. E150 ELEC, FINAL IC 07/21/2006 10:19 AM DS PDA E150 ELEC, FINAL IC main power messed up P105 PLBG, TOP OUT IC 05/26/2006 12:57 PM JGM PDA P105 PLBG, TOP OUT IC need walkway and workplatform P125 PLBG, FINAL IC All Electric No Gas Page 1 WF0763886 / 001 City of College Sitation PAGE 1 REQ. DATE: 04/27/06 0Vc-, 04/27/06 10:51:16 LOCATION: 126 STERLING ST LOC ID: 202886 REQUESTOR: JOE COURTNEY ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/27/06 SCHED COMPLETION: 04/27/06 ******************************************************************************** JOB ORDER RESULT COMIENTS WF0773186 / 001 City of College Station PAGE 1 REQ. DATE: 05/15/06 05/15/06 14:32:31 LOCATION: 126 STERLING ST LOC ID: 202886 REQUESTOR: JOE COURTNEY HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/15/06 SCHED COMPLETION: 05/15/06 ******************************************************************************** JOB ORDER RESULT COMYIEN`I'S O l�- i I c6z. City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 7/25/06 Parcel Number . . . . . 542500-0020-0040 Property Address . . . 126 STERLING ST COLLEGE STATION TX 77840 Subdivision Name . . . RICHARDS Legal Description . . . RICHARDS SUBDIVISION-HAMPTON ESTATES LOT 4 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . Contractor . . . . . . JOE COURTNEY 979 774-8955 Application number 06-00001182 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved Buildi g Official VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILD11110 PERMIT CITY OF COLLEGE STATION 1101 TE)bZ5 A+E COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00001182 Date 4/18/06 126 STERLING ST 542500-0020-0040 RESIDENTIAL, 1 UNIT DETACHED NEW RICHARDS RESIDENTIAL SINGLE FAMILY RESIDENTIAL 96690 Owner Contractor ------------------------ ------------------------ JOE COURTNEY P.O. BOX 4043 BRYAN TX 77803 (979) 774-8955 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1465.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 285.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc BK Permit Fee 448.00 Plan Check Fee .00 Issue Date 4/18/06 Valuation . . . . 96690 Expiration Date 10/15/06 Qty Unit Charge Per Extension BASE FEE 260.00 47.00 4.0000 THOU BLDG, VAL 50001-100000 188.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQ IPMENT AND WALKWAY ------------------------------------------- ----- id- ----------- BUILDING DEPT REPRESENTATIVE: APPLICANT: �- 1.. BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEAS At COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001182 Page 2 Date 4/18/06 Special Notes and Comments PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For T is Plan -------------------------------Z-- - ------------ BUILDING DEPT REPRESENTATIV . = _3 APPLICANT : (,�L...w� — - — BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001182 Page 3 Date 4/18/06 Special Notes and Comments PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall bracing by prescriptive OSB and Alternate braced panel. Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 448.00 448.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 448.00 448.00 .00 .00 ------------------------------------------- 1------ 1J-_"-----Z-.------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: �-J. TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00001215 Date 4/18/06 126 STERLING ST 542500-0020-0040 TEMP POLE RICHARDS RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ JOE COURTNEY P.O. BOX 4043 BRYAN TX 77803 (979) 774-8955 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc BK Permit Fee . . . . 20.00 Issue Date . . . . 4/18/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------- ------- -�01 �' N------------ BUILDING DEPT REP SENTATIVE: ' APPLICANT: For Office Use Only APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning 6 Development Services WWW.CSTX.GOV DATE: -1, ' 1 d Ems_ _ APPLICATION # �Ol9 TEMP POLE # (at - C'� ADDRESS/LOCATION: I td✓ LOT __ " BLOCK __ SUBDIVISION P-jQA2D5 41jL2_>11AGtDt,) / SEC/PH HAWTDN 6&rA-r85 BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: . pr C.ou12-Y► cM Wq'6.' IOC• PHONE: CONTRACTOR ADDRESS: P.D, gDX dod;�,, a-'(Ao 4 `t5C 17&5 ELECTRICIAN: bb-b 1C PLUMBER: l'.G W PWttA)d& HVAC: JOWUAALI#—: l jCo�;, GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: RUILD N1W '5A)6 C F,4r6KY STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: A TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: 14 5HEATED AREA: 14.65 5� or andMaterials) (Cost of Lqui PUBLIC SEWER qD NUMBER OF BEDROOMS: _ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: N INTERIOR WALL TYPE: _zx4 SruD / &YP. BP. SIZE WATER TAP: 3 u EXTERIOR WALL TYPE: 44 Pl eock j fQ'M SIZE OTHER TAP: FOUNDATION TYPE: 5u& po 1,w� SIZE ® TEMP POLE ROOF TYPE: �p(P c�.(/�6LIr GARAGE TYPE: SINGLE a DOUBLE a TRIPLE 2 ATTACHED DETACHE F-] CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commer i I con 4tru tion or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only JPlans Examiner S NO Zoning Official — r��esc/l�p� ve �ea �1-•5 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating Q ID � 13 3o CITY OF COLLEGE STATION Planning d Development Services 1 i PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# �� _ 18� DATE: BUILDING ADDRESS: /��� ��eal►n�, s+ I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier la out shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated N II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. I PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d' Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes In wi III. Stairway Requirements N OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal (*hrq" CITY OF COLLEGE STATION Planning 6-Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS FW V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N Att K A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vlll. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N O Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ K Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required N (*hrq" CITY OF COLLEGE STATION Planning d Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLANS EXAMINER DATE