HomeMy WebLinkAboutRES2006-01173, 06-1174H752113 100/619P4
PREPARED 8/24/06, 12:14:22 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/24/06
------------------------------------------------------------------------------------------------
ADDRESS . : 941 WHITEWING LN SUBDIV: DOVE CROSSING
CONTRACTOR D R HORTON HOMES PHONE (979) 224-1826
OWNER . . PHONE
PARCEL . . 005401-0101-0210
APPL NUMBER: 06-00001173 RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/01/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
5/01/06 AP April 28, 2006 10:27:25 AM kwolfe
Monday PM
05/01/2006 03:41 PM RH PDA
Survey on file, slab ground installed.
B115 �1 .4=6/15/06 JGM BLDG, FRAMING TIME: 17:00
6/15/06 AE June 15, 2006 11:22:50 AM glsouth
Form Survey Submitted
06/15/2006 03:12 PM JGM PDA
replace letin brace in kicthben, missing a.b. nuts
B130 01 6/21/06 RH BLDG, INSULATION TIME: 17:00
' 6/21/06 DP June 20, 2006 4:21:38 PM bkorthauer
i
06/21/2006 11:34 AM RH PDA
Seal all exterior and attic penetrations and don't stuff
insulation. Use proper insulation thickness.
B130 02 6/23/06 DS BLDG, INSULATION TIME: 17:00
6/23/06 AP June 23, 2006 12:43:52 PM glsouth
B125 O1 8/24/06 BI BLDG, FINAL TIME: 17:00
August 24, 2006 10:36:51 AM glsouth
-------------------------------------- COMMENTSAN -------------------------------------- Lp
D NOTES
� Cam•• �S�' � II ���
Date: 8/25/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1173
Address: 941 WHITEWING LN
Insp.
Type
Inspection Type Code
Description
Insp.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
05/01/2006 03:41 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Survey on file, slab ground installed.
B115
BLDG, FRAMING
IC
Form Survey Submitted
B115
BLDG, FRAMING
IC
06/15/2006 03:12 PM JGM PDA
B115
BLDG, FRAMING
IC
replace letin brace in kicthben, missing a.b. nuts
B130
BLDG, INSULATION
IC
06/21/2006 11:34 AM RH PDA
B130
BLDG, INSULATION
IC
Seal all exterior and attic penetrations and don't stuff
B130
BLDG, INSULATION
IC
insulation. Use proper insulation thickness.
Page 1
WF0766351 / 001 City of College Station
PAGE
REQ. DATE:
05/03/06
"
05/03/06
11:17:39
LOCATION:
941 WHITEWING LN
LOC ID:
202826
REQUESTOR:
D R HORTON
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH
AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW
UTILITY ACCT SET
READY
SCHED START:
05/03/06
SCHED COMPLETION:
05/03/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0761731 / 001 City of College Station
PAGE
REQ. DATE: 04/20/06 •7 04/20/06 10:53:45
LOCATION: 941 WHITEWING LN LOC ID: 202826
REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/20/06 SCHED COMPLETION: 04/20/06
********************************************************************************
JOB ORDER RESULT COMMEATI'S
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
----------------PHONE_ (979)764-3570 FAX: (979)764-3496
------------ ' --------------------------------------
Application Number .
. . . . 06-00001173 Date 4/20/06
Property Address . .
. . . . 941 WHITEWING LN
Property ID:
005401-0101-0210
R #:
R13907
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . DOVE CROSSING
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 99528
Owner
Contractor
------------------------
------------------------
D R HORTON HOMES
12554 RIATA VISTA CIR
AUSTIN TX 78727
(979) 224-1826
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1508.00
INTERIOR WALL TYPE SHEET ROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
BK
Permit Fee . . . .
460.00 Plan Check Fee .00
Issue Date . . . .
4/20/06 Valuation . . . . 99528
Expiration Date . .
10/17/06
Qty Unit Charge
Per Extension
BASE FEE 260.00
50.00 4.0000
THOU BLDG, VAL 50001-100000 200.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM OUGH-F AMED, SIZE 2211
•
------------------------
BUILDING DEPT REPRESENTATIVE+,
-- -- -'-�-------------
•
maw
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------- 4---- t-------------------------------------
Application Number . . . . . 06-00001173
Page 2
Date 4/20/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam
ANY CHANGES OR ALTERATIONS TO SUBMITTED
RESUBMITTED A
BUILDING DE
APPLICANT:
or other means.
PLANS MUST BE
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------'----'-------------------------------------
Application Number . . . . . 06-00001173
Page 3
Date 4/20/06
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
BUILDING DEPT
APPLICANT:
PRESENTATIVE:
-'\
i
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------'----=-------------------------------------
Page 4
Application
Number
. . . . .
06-00001173
Date 4/20/06
----------------------------------------------------------------------------
Special Notes and Comments
Engineered
bracing
methods used
to meet
narrow wall
bracing
----------------------------------------------------------------------------
Other Fees
. . . .
. . . . .
SEWER TAP
4"
350.00
WATER TAP
3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
Credited
Due
Permit Fee
Total
460.00
----------
460.00
----------
.00
----------
.00
Plan Check
Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1210.00
1210.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
--------------------------------------`-------------------------------------
Application Number
. . . . .
06-00001177 Date
4/20/06
Property Address
. . . . . .
941 WHITEWING LN
Property ID:
005401-0101-0210
R #:
R13907
Application type description
TEMP POLE
Subdivision Name
. . . . . .
DOVE CROSSING
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
D R HORTON HOMES
12554 RIATA VISTA CIR
AUSTIN
TX 78727
(979) 224-1826
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/20/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------------------------------------
BUILDING DEPT VF` SENTATIlE:
APPLICANT:
-----��--- - f-----------
Io:512 218 4299 P.3/4
C'rY OF COLLEGE S A:110N
PIs.eHipr d' Ihulnpmml snvi ,
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (972) 764.3498 FAX
WWW.CSTX.GOV
DATE: C REG
APPUCATtON v 06 — Lns
TEMP POLE #
ADDRESS/LOOCATION: J hI wlki L--- ,
LOT ✓BLOCK ` SUBDIVISION o oI Cjo S SEC/PH
BUSINESS/OWNER NAME: PHONE;Ma' 533'1K rJ"�
CONTRACTOR/HOMEOWNER; (�-p PHONE: SI Az 53 3
CONTRACTOR ADD
%sue c f?6 60 -- h�, 7)c �� f J1�
ELECTRICIAN: O PLUMBER: ASS ��� r of�//731-
Y_HVAC: — GOOD CENTS (Residential only):
CLASS OF WORK
ACC ESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODELJRENOVATION* SWIMMING POOL
Required) 1
DESCRIPTION OF WORK: U\0� � ..►o_
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL -
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: 19 53 HEATED AREA:
( ost a1 nd Mat als)
✓PUBLIC SEWERf NUMBER OF BEDROOMS: 3
SEPTICfTREATMENY SYSTEM
Fq/S'EWERTAP: ` 0
SIZE f
El -WATER TAP:
SqE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE E]
ATTACHED
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE: RctSc> I(✓'
FOUNDATION( TYPE;
ROOF TYPE: ��-• O
DOUBLE 'TRIPLE
DETACHED a CARPORT a
SIGNATURE OF APPLICANT:
*If proposed work involves new�com1 iai construction or facade improvements/renovations to an existing
commercial property, building el�ations are requirad.
4@0@OP4444?d@♦44440?0®.}4404®046404444+944444944444d0o-44e�44®
OftTclal Use Only
fr4 Fr� Pins Ex"i„iner
� 6"C U/8
L
ents:
mrNo
Zonlncg Offlclal '
PIE'n,ergy Code Compliance In rmcltion ,
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
.A/C SEER Ratirig-� ..
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6, Development Services
PLAN REVIEW/PERMIT NUMBER# o6 _
DATE: q / ►y / o�
BUILDING ADDRESS: 9y/ hrl+,ew
Lrv.
I. Foundation Requirements
NA/ K
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NAJ,
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
dA
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
dA
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6) inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated on plans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
IR!
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d-Development Services
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
NAtbyj
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
K
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
JO
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
Does not block any water course or divert any flow
Elevation certificate if required
� 4
/"
CITY OF COLLEGE STATION
Planning c5 Development Services
Comments:
,PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
,�4 Ir
PLANS EXAMINER `T DATE