HomeMy WebLinkAboutRES2006-01173, 06-1174H752113 100/619P4 PREPARED 8/24/06, 12:14:22 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/24/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 941 WHITEWING LN SUBDIV: DOVE CROSSING CONTRACTOR D R HORTON HOMES PHONE (979) 224-1826 OWNER . . PHONE PARCEL . . 005401-0101-0210 APPL NUMBER: 06-00001173 RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/01/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 5/01/06 AP April 28, 2006 10:27:25 AM kwolfe Monday PM 05/01/2006 03:41 PM RH PDA Survey on file, slab ground installed. B115 �1 .4=6/15/06 JGM BLDG, FRAMING TIME: 17:00 6/15/06 AE June 15, 2006 11:22:50 AM glsouth Form Survey Submitted 06/15/2006 03:12 PM JGM PDA replace letin brace in kicthben, missing a.b. nuts B130 01 6/21/06 RH BLDG, INSULATION TIME: 17:00 ' 6/21/06 DP June 20, 2006 4:21:38 PM bkorthauer i 06/21/2006 11:34 AM RH PDA Seal all exterior and attic penetrations and don't stuff insulation. Use proper insulation thickness. B130 02 6/23/06 DS BLDG, INSULATION TIME: 17:00 6/23/06 AP June 23, 2006 12:43:52 PM glsouth B125 O1 8/24/06 BI BLDG, FINAL TIME: 17:00 August 24, 2006 10:36:51 AM glsouth -------------------------------------- COMMENTSAN -------------------------------------- Lp D NOTES � Cam•• �S�' � II ��� Date: 8/25/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1173 Address: 941 WHITEWING LN Insp. Type Inspection Type Code Description Insp. status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 05/01/2006 03:41 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Survey on file, slab ground installed. B115 BLDG, FRAMING IC Form Survey Submitted B115 BLDG, FRAMING IC 06/15/2006 03:12 PM JGM PDA B115 BLDG, FRAMING IC replace letin brace in kicthben, missing a.b. nuts B130 BLDG, INSULATION IC 06/21/2006 11:34 AM RH PDA B130 BLDG, INSULATION IC Seal all exterior and attic penetrations and don't stuff B130 BLDG, INSULATION IC insulation. Use proper insulation thickness. Page 1 WF0766351 / 001 City of College Station PAGE REQ. DATE: 05/03/06 " 05/03/06 11:17:39 LOCATION: 941 WHITEWING LN LOC ID: 202826 REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/03/06 SCHED COMPLETION: 05/03/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0761731 / 001 City of College Station PAGE REQ. DATE: 04/20/06 •7 04/20/06 10:53:45 LOCATION: 941 WHITEWING LN LOC ID: 202826 REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/20/06 SCHED COMPLETION: 04/20/06 ******************************************************************************** JOB ORDER RESULT COMMEATI'S BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 ----------------PHONE_ (979)764-3570 FAX: (979)764-3496 ------------ ' -------------------------------------- Application Number . . . . . 06-00001173 Date 4/20/06 Property Address . . . . . . 941 WHITEWING LN Property ID: 005401-0101-0210 R #: R13907 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 99528 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATA VISTA CIR AUSTIN TX 78727 (979) 224-1826 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1508.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc BK Permit Fee . . . . 460.00 Plan Check Fee .00 Issue Date . . . . 4/20/06 Valuation . . . . 99528 Expiration Date . . 10/17/06 Qty Unit Charge Per Extension BASE FEE 260.00 50.00 4.0000 THOU BLDG, VAL 50001-100000 200.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-F AMED, SIZE 2211 • ------------------------ BUILDING DEPT REPRESENTATIVE+, -- -- -'-�------------- • maw APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------- 4---- t------------------------------------- Application Number . . . . . 06-00001173 Page 2 Date 4/20/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam ANY CHANGES OR ALTERATIONS TO SUBMITTED RESUBMITTED A BUILDING DE APPLICANT: or other means. PLANS MUST BE BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------'----'------------------------------------- Application Number . . . . . 06-00001173 Page 3 Date 4/20/06 Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES BUILDING DEPT APPLICANT: PRESENTATIVE: -'\ i BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------'----=------------------------------------- Page 4 Application Number . . . . . 06-00001173 Date 4/20/06 ---------------------------------------------------------------------------- Special Notes and Comments Engineered bracing methods used to meet narrow wall bracing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited Due Permit Fee Total 460.00 ---------- 460.00 ---------- .00 ---------- .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1210.00 1210.00 .00 .00 ------------------- BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 --------------------------------------`------------------------------------- Application Number . . . . . 06-00001177 Date 4/20/06 Property Address . . . . . . 941 WHITEWING LN Property ID: 005401-0101-0210 R #: R13907 Application type description TEMP POLE Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATA VISTA CIR AUSTIN TX 78727 (979) 224-1826 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc BK Permit Fee . . . . 20.00 Issue Date . . . . 4/20/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 -------------------------------------------- BUILDING DEPT VF` SENTATIlE: APPLICANT: -----��--- - f----------- Io:512 218 4299 P.3/4 C'rY OF COLLEGE S A:110N PIs.eHipr d' Ihulnpmml snvi , APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (972) 764.3498 FAX WWW.CSTX.GOV DATE: C REG APPUCATtON v 06 — Lns TEMP POLE # ADDRESS/LOOCATION: J hI wlki L--- , LOT ✓BLOCK ` SUBDIVISION o oI Cjo S SEC/PH BUSINESS/OWNER NAME: PHONE;Ma' 533'1K rJ"� CONTRACTOR/HOMEOWNER; (�-p PHONE: SI Az 53 3 CONTRACTOR ADD %sue c f?6 60 -- h�, 7)c �� f J1� ELECTRICIAN: O PLUMBER: ASS ��� r of�//731- Y_HVAC: — GOOD CENTS (Residential only): CLASS OF WORK ACC ESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODELJRENOVATION* SWIMMING POOL Required) 1 DESCRIPTION OF WORK: U\0� � ..►o_ STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL - TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: 19 53 HEATED AREA: ( ost a1 nd Mat als) ✓PUBLIC SEWERf NUMBER OF BEDROOMS: 3 SEPTICfTREATMENY SYSTEM Fq/S'EWERTAP: ` 0 SIZE f El -WATER TAP: SqE OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE E] ATTACHED NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: RctSc> I(✓' FOUNDATION( TYPE; ROOF TYPE: ��-• O DOUBLE 'TRIPLE DETACHED a CARPORT a SIGNATURE OF APPLICANT: *If proposed work involves new�com1 iai construction or facade improvements/renovations to an existing commercial property, building el�ations are requirad. 4@0@OP4444?d@♦44440?0®.}4404®046404444+944444944444d0o-44e�44® OftTclal Use Only fr4 Fr� Pins Ex"i„iner � 6"C U/8 L ents: mrNo Zonlncg Offlclal ' PIE'n,ergy Code Compliance In rmcltion , % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork .A/C SEER Ratirig-� .. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6, Development Services PLAN REVIEW/PERMIT NUMBER# o6 _ DATE: q / ►y / o� BUILDING ADDRESS: 9y/ hrl+,ew Lrv. I. Foundation Requirements NA/ K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning er Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NAJ, 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" dA S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes dA III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6) inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated on plans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal IR! PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d-Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements NAtbyj A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements K Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 JO Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 Does not block any water course or divert any flow Elevation certificate if required � 4 /" CITY OF COLLEGE STATION Planning c5 Development Services Comments: ,PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS ,�4 Ir PLANS EXAMINER `T DATE