Loading...
HomeMy WebLinkAboutRES2006-01145, 06-1146�i� 4 Owip) 11 OPendafle)C OEssseete R 7521/3 10%�P4 C 6 WF0760957 / 001 City of Coiiege Station PAGE 1 REQ. DATE: 04/18/06 04/18/06 14:50:06 LOCATION: 2457 NEWARK CIR LOC ID: 203998 REQUESTOR: PITCOCK & CROIX, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/18/06 SCHED COMPLETION: 04/18/06 ******************************************************************************** JOB ORDER RESULT C014MENTS PREPARED 9/21/06, 12:15:43 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/21/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 2457 NEWARK CIR SUBDIV: CASTLEGATE PH 5 SEC 2 CONTRACTOR PITCOCK & CROIX PHONE (979) 764-7551 OWNER . . PHONE PARCEL . . 184200-2501-0210 APPL NUMBER: 06-00001145 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/27/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/27/06 AP T/S: 04/26/2006 03:37 PM GLSOUTH ----------------------- Strings On Setbacks O.K. Slab Ground Installed B115 01 6/27/06 OC BLDG, FRAMING TIME: 17:00 6/27/06 AP June 26, 2006 1:57:42 PM bkorthauer June 27, 2006 12:43:05 PM kwolfe B130 01 7/03/06 JGM BLDG, INSULATION TIME: 17:00 7/03/06 AP July 3, 2006 7:59:37 AM kwolfe B125 02 9/19/06 RH BLDG, FINAL TIME: 17:00 9/19/06 DP September 15, 2006 4:23:49 PM ncochran 09/19/2006 04:22 PM RH PDA Need continous handrail at stairs. B125 03 /21/%6 1 BLDG, FINAL TIME: 17:00 4 lai1Or_ &&# - September 21, 2006 12:15:10 PM kwolfe ------------------------------------- COMMENTS AND NOTES -------------------------------------- • f�� 2x�a r► S Jn��(Q �� Date: 9/19/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1145 Address: 2457 NEWARK CIR Insp. inspection Type Code Description p. Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC June 27, 2006 12:43:05 PM kwolfe E150 ELEC, FINAL IC 09/18/2006 11:24 AM JGM PDA E150 ELEC, FINAL IC plug on island not gfi protected, outside gfi has open E150 ELEC, FINAL IC ground, need smoke detecto in and outside front bedroom, E150 ELEC, FINAL IC smoke detectors need proper clearance from ceiling fan, E150 ELEC, FINAL IC and ac vents Page 1 WF0761274 / 001 City of College Station PAGE 1 ou_( (4S REQ. DATE: 04/19/06 04/19/06 12:06:45 LOCATION: 2457 NEWARK CIR LOC ID: 203998 REQUESTOR: PITCOCK & CROIX ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/19/06 SCHED COMPLETION: 04/19/06 ******************************************************************************** JOB ORDER RESULT COMMENTS Nicole Cochran - Re Calling for CO @ 2457 Newark Cir Page 1 From: Joe Garcia To: Benjamin McCarty; Chris Haver; Gina Southerla... Date: 9/21/2006 3:46 pm Subject: Re: Calling for CO @ 2457 Newark Cir THE SEWER BOX HAS BEEN REPLACED. THIS IS GOOD TO GO. JMG >>> Terry Boriskie 09/20/06 10:58 AM >>> Randall Pitcock has been contacted and will repair. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Joe Garcia 9/19/2006 3:39 pm >>> THE SEWER BOX, AND SEWER LID ARE BOTH BROKEN & WILL NEED TO BE REPLACED. THE WATER BOX IS OK. JMG >>> Kim Wolfe 09/19/06 12:05 PM >>> Are there any issues? BP # 06-1145 Thanks Kimberly Wolfe City of College Station Planning & Development Services (979)764-3570 www.cstx.Qov ,Nicole Cochran Re. Calling for CO @ 2457 Newark Cir 1 From: Terry Boriskie To: Benjamin McCarty; Chris Haver; Gina Southerla... Date: 9/20/2006 10:58 am Subject: Re: Calling for CO @ 2457 Newark Cir Randall Pitcock has been contacted and will repair. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Joe Garcia 9/19/2006 3:39 pm >>> THE SEWER BOX, AND SEWER LID ARE BOTH BROKEN & WILL NEED TO BE REPLACED. THE WATER BOX IS OK. JMG >>> Kim Wolfe 09/19/06 12:05 PM >>> Are there any issues? BP # 06-1145 Thanks Kimberly Wolfe City of College Station Planning & Development Services (979)764-3570 www.cstx.Qov BUILDING P=IT CITY OF .C.Q&.UEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570k FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001145 Date 4/18/06 Property Address . . . . . . 2457 NEWARK CIR Property ID: 184200-2501-0210 R #- Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 195690 Owner Contractor ------------------------ ------------------------ PITCOCK & CROIX RANDALL PITCOCK & MIKE CROIX PO BOX 10276 COLLEGE STATION TX 77842 (979) 764-7551 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2965.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 748.00 Plan Check Fee .00 Issue Date . . . . 4/18/06 Valuation . . . . 195690 Expiration Date . . 10/15/06 Qty Unit Charge Per Extension BASE FEE 460.00 96.00 3.0000 THOU BLDG, VAL 100001-500000 288.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) --------------------------- BUILDING DEPT REPRESENTATIVE: ---- -- ---•- 4----------- APPLICANT: BUILDING PERMIT CITY OFr COLI;EGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00001145 Date 4/18/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE - --------------- ----- ------ ---------- -------- ------ -- -- -- ----------- BUILDING DEPT REPRESENTATIVE: l APPLICANT: �� BUILDING PERMIT CITY OF% COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number 06-00001145 Page 3 Date 4/18/06 Special Notes and Comments POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS Add smoke detector inside and outside Study because of bedroom characteristics SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE ----------------------------------------------- ------ --- -- -- ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OFiCOLDEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001145 Date 4/18/06 ---------------------------------------------------------------------------- Special Notes and Comments PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall bracing Fully Sheathed with APA garage framing and Interior anchors and bracing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 748.00 748.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1498.00 1498.00 .00 .00 ----------------------------------�--- -- -•---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: iYd TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001146 Date 4/18/06 Property Address . . . . . . 2457 NEWARK CIR Property ID: 184200-2501-0210 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ PITCOCK & CROIX RANDALL PITCOCK & MIKE CROIX PO BOX 10276 COLLEGE STATION TX 77842 (979) 764-7551 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date . . . . 4/18/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------- ----------------- BUILDING DEPT REPRESENTATIVE - APPLICANT: T APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY ON COLLEGE STATION (979) 764-3670 (979) 764-3496 FAX l+Gnai+g dUrvrlapmra€ Srrni�rr WWW.CSTX.GOV ADDRESS/LOCATION: ? y5 �; P e_ e_ �14f� For Ofte Use Only DATE:413 &R C RE APPLICATION # TEMP POLE # { W LOT aS U19LOCK ✓ SUBDIVISION �c� QQ ,� SEC/PH �377 BUSINESS/OWNER NAME: �'�O-G� PHONE: ?6 % CONTRACTOR/HOMEOWNER: PHONE: CONTRACTOR ADDRESS: / " D . /30 /D� J� Goa 11-c 4. , 77e8 Z ELECTRICIAN: 1ze1_w1z'a PLUMBER: HVAC: _ �1'l� GOOD CENTS (Residential only): ® _ CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey),>< NEW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION" SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ -If VALUATION: $ /'9�99. 0O I, -'TOTAL AREA: 3e66 Labor HEATED AREA: (Cost of and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: va ' oL SEWER TAP: 'el INTERIOR WALL TYPE: v `ZZE WATER TAP: 3 `� f/ EXTERIOR WALL TYPE: E�li SIZE OTHER TAP: FOUNDATION TYPE: SIZE © TEMP POLE ROOF TYPE: Cep .%vim GARAGE TYPE: SINGLE F__1 DOUBLE F5q TRIPLE I6� ATTACHED X DETACHED F-1 CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commetcial constrw6tion of fac de improvements/renovations to an existing commercial property, building elevations are required. Official Use Only 72/� 7 C S eN0 Plans Examiner Zoning Official L d i,j , �J h cjtootk a4�yt cS •, .� T F�°'� V�-�"1' DDfl �- � i' � �- N� `�'�'g.-eau •x, � - Energy Code Compliance Information % Glazing of exterior walls 1,4, Insulation R value of exterior walls /3 Z' Insulation R value of ceiling 1 (flat areas) 3D � Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC _ Glazing U-Factor D- R value of ductwork G A/C SEER Rating /3 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW/PERMIT NUMBER# 6 _ y DATE: l l 06 BUILDING ADDRESS: dgys ew k C' a. I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated AJA- II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA O 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. T. Protected openings on walls < three feet from property line One hour tenant separation to roof deck between duplexes N III. Stairway Requirements N A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six (6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal CITY OF COLLEGE STATION Planning cr Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NAM A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VI1. Mechanical Requirements NAYJW A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VII1. Energy Requirements N O A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NACCW Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side (intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required I �/ I`r 10 (*f/"" CITY OF COLLEGE STATION Planning & Development Services Comments: c LANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS `/ 7-76 DATE