HomeMy WebLinkAboutRES2006-01121, 06-1122CA.Q - 11 Off,-�12a Kim Wolfe Re: Calling for CO @5124 Congressional Dr. Page 1 r From: Joe Garcia To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie Date: 9/14/2006 4:23:19 PM Subject: Re: Calling for CO @5124 Congressional Dr. This one is good to go. JMG >>> Nicole Cochran 09/14/06 12:08 PM >>> Are there any issues? BP # 06-1121 Thanks! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov PREPARED 9/14/06, 11:41:29 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/14/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 5124 CONGRESSIONAL DR SUBDIV: PEBBLE CREEK CONTRACTOR T C CUSTOM HOMES PHONE (979) 693-7835 OWNER PEBBLE CREEK DEVELOPMENT CO PHONE PARCEL 497900-0037-0030 APPL NUMBER: 06-00001121 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/01/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/01/06 CA April 28, 2006 2:00:30 PM kwolfe early AM - monday Not Ready For Inspection B100 02 5/02/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/02/06 AP May 2, 2006 8:12:43 AM bkorthauer late morning Strings On Setbacks O.K. Slab Ground Installed B115 01 6/27/06 OC BLDG, FRAMING TIME: 17:00 6/27/06 AP June 27, 2006 9:46:08 AM glsouth June 27, 2006 12:43:22 PM kwolfe B130 01 7/05/06 OC BLDG, INSULATION TIME: 17:00 7/05/06 AP July 5, 2006 10:01:10 AM malford B125 01 9 14/06 BI BLDG, FINAL TIME: 17:00 ti September 14, 2006 9:13:43 AM ncochran ------------------------j -------- CONTINUED ONTO NEXT PAGE ----------------------------------- I-L�4� SSG of 0�1 Date: 9/14/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1121 Address: 5124 CONGRESSIONAL DR Insp. Inspection Type Code Status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Not Ready For Inspection B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC June 27, 2006 12:43:22 PM kwolfe E110 ELEC, ROUGH IN IC June 27, 2006 12:43:39 PM kwolfe M100 MECH, ROUGH IN IC June 27, 2006 12:44:02 PM kwolfe P105 PLBG, TOP OUT IC June 27, 2006 12:43:49 PM kwolfe Page 1 I. WF0761711 / 001 City of College Station PAGE 1 REQ. DATE: 04/20/06 04/20/06 10:23:32 LOCATION: 5124 CONGRESSIONAL DR LOC ID: 199738 REQUESTOR: T C CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/20/06 SCHED COMPLETION: 04/20/06 ******************************************************************************** JOB ORDER RESULT CONV=S WF0761632 / 001 City of College Station PAGE 1 REQ. DATE: 04/20/06 04/20/06 8:27:38 LOCATION: 5124 CONGRESSIONAL DR LOC ID: 199738 REQUESTOR: TC HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/20/06 SCHED COMPLETION: 04/20/06 JOB ORDER RESULT COMMENTS City of College---S,t-ation 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . 9/15/06 497900-0037-0030 5124 CONGRESSIONAL DR COLLEGE STATION TX 77845 PEBBLE CREEK PEBBLE CREEK #9-B, BLOCK 37, L OT 3 SINGLE FAMILY RESIDENTIAL PEBBLE CREEK DEVELOPMENT CO Contractor . . . . . . T C CUSTOM HOMES 979 693-7835 Application number 06-00001121 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . Approved . . . . . . . \=B�k�dg Official VOID UNLESS SIGNED BY BUILDING OFFICIAL Y PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW/PERMIT NUMBER# 6 & _ 11 Z DATE: (4/ n / o6 BUILDING ADDRESS: ,say Div , I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing -of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NAT, 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. T. Protected openings on walls < three feet from property line One hour tenant separation to roof deck between duplexes AIA III. Stairway Requirements N K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Development Servicer V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location Vl. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vlll. Energy Requirements NArW A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 AMOK Does not block any water course or divert any flow Elevation certificate if required PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning c5 Development Services Comments: "'A f. PLANS EXAMINER DATE r TC HOMES 5124 CONGRESSIONAL 2nd FLOOR OPENING SCHEDULE WINDOW SCHEDULE PRODUCT CODE SIZE COUNT 36X24 PW, 2 by 2 3'-0" x 2'-0" 3 44X&O SH, 2/2 3'-8" x 5'-0" 1 36X(oO SH, 2/2, TWIN 6'-O" x 5'-0" 3 60X12 PW, ROUND TOP 5'-O" x 6'-O" I DOOR SCHEDULE PRODUCT CODE SIZE HINGE DIRECTION COUNT 12x80 BIFOLD, 2 PANEL -ROMAN ARCH 6'-O" RL I 28X80, 2 PANEL -ROMAN ARCH 2'-4" L 3 28X80 2 PANEL -ROMAN ARCH 2'-4" R I 32X80 2 PANEL -ROMAN ARCH 2'-8" L 2 32X80 2 PANEL -ROMAN ARCH 2'-8" R I roOX80 POP, 2 PANEL -ROMAN ARCH 5'-O" RL I 28X80 POCKET, 2 PANEL -ROMAN ARCH 2'-4" N 2 w TC HOMES 5124 CONGRESSIONAL let FLOOR OPENING SCHEDULE WINDOW SCHEDULE PRODUCT CODE SIZE COUNT 4BX48 PW, TEMP, I by 1, CLEAR 4'-0" x 4'-0" 1 36XroO SH, 2/2, TRIPLE 8'-O" x ro'-O" 1 36X-T2 SH, 2/2, TEMP. 3'-0" x -1'-0" 1 36X24 PW, 2 by 2 3'-0" x 2'-0" 2 36X72 SH, 2/2 3'-O" x 1'-0" 3 toOX12 SH, 2/2, TWIN 6'-O" x 6'-O" 2 DOOR SCHEDULE PRODUCT CODE SIZE HINGE DIRECTION COUNT 32X80 EXT, 2 PANEL -ROMAN ARCH 2'-8" R 2 36X80 POP, 2 PANEL -ROMAN ARCH 3'-0" RL 1 28X80 2 PANEL -ROMAN ARCH 2'-41I L 3 3OX80 2 PANEL -ROMAN ARCH 2'-6" L i 32X80 2 PANEL -ROMAN ARCH 2'-8" R I 34X80 LOUVERED (UTILITY) 3'-0" L I 48X80 PAINT GRADE, POP, DIV LITE 4'-0" RL I r OX80 MAHOGANY, 2 PANEL -ROMAN ARCH w/SL 5'-0" L I 36X80 EXT, METAL, FRENCH, I LITE 3'-0" R I 192X84 OVERHEAD GARAGE DOOR 18'-3" N I y BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS ,AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001121 Date 4/19/06 Property Address . . . . . . 5124 CONGRESSIONAL DR Property ID: 497900-0037-0030 R #: R117702 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 288500 Owner Contractor ------------------------ PEBBLE CREEK DEVELOPMENT ------------------------ CO T C CUSTOM HOMES % YOUNG, DAVIS TODD CARNES 4500 PEBBLE CREEK PKWY 230 SOUTHWEST PARKWY E COLLEGE STATION TX 778458942 COLLEGE STATION TX 77840 (979) 693-7835 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) DET HEATED AREA 3106.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 3.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 419.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 1027.00 Plan Check Fee .00 Issue Date . . . . 4/19/06 Valuation . . . . 288500 Expiration Date . . 10/16/06 Qty Unit Charge Per Extension BASE FEE 460.00 189.00 3.0000 THOU BLDG, VAL 100001-500000 567.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) -------- ---------- ------- ------------ • BUILDING DERT REPREiENTATIVE y APPLICANT: ---------------------------- BUILDING DEPX REPRES APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001121 Page 2 Date 4/19/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE ----------------- ----- X - --�'--------- KTATIVE: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS ,AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001121 Page 3 Date 4/19/06 Special Notes and Comments POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) ---------------------------------------------- ---- - -- --------- BUILDING DEPT REPRESEN ATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001121 Date 4/19/06 ---------------------------------------------------------------------------- Special Notes and Comments RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall Bracing Fully Sheathed ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 1027.00 1027.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1777.00 1777.00 .00 .00 --------------------------------------------- ---- -- •---------- AA BUILDING DEPT-,,,REPRESEIJTATIVE : APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001122 Date 4/19/06 Property Address . . . . . . 5124 CONGRESSIONAL DR Property ID: 497900-0037-0030 R #: R117702 Application type description TEMP POLE Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ PEBBLE CREEK DEVELOPMENT CO ------------------------ T C CUSTOM HOMES % YOUNG, DAVIS TODD CARNES 4500 PEBBLE CREEK PKWY 230 SOUTHWEST PARKWY E COLLEGE STATION TX 778458942 COLLEGE STATION TX 77840 (979) 693-7835 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc BK Permit Fee . . . . 20.00 Issue Date . . . . 4/19/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged --------------------------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------- ---- - ------------- BUILDING DEPT \REPRES4NTATIVE I APPLICANT: 1q, APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Planning d Development Services For Office Use Only DATE: q I & T(RCC REG APPLICATION #N�y 1 ( TEMP POLE # ADDRESS/LOCATION: 512-4 CoN69Z-?sSIC NAL- 0 V LOT _ ' BLOCK,4UBDIVISION fl_--13E3LECft BUSINESS/OWNER NAME: PHONE: (3 CONTRACTOR/HOMEOWNER: t "M Es PHONE: lU "1 J --1635 CONTRACTOR ADDRESS: 2-3 O , W NA`Y L�T I CO ULEC-c SFAM OK , T\� -173,fk) I ELECTRICIAN: ?, `'J aF_0?_4L PLUMBER: ASS IPWR61 N6 HVAC: IVkC+g,C-- N A/c, GOOD CENTS (Residential only): N CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: COW-MIX-MON OF 'SNOLU 9SIVI N DWEIUN61 PROPOSED USE: N N(XLE EPS- W U T)W ELLA N161 HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE -APPROVAL: 1ES TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ IJ/A VALUATION: $ 2-BS, '� TOTAL AREA: 3g32 HEATED AREA: NO(O (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ii SEWER TAP: 'A WATER TAP: OTHER TAP: R11TEMP POLE 1 GARAGE TYPE SIZE Sly SIZE SIZE SINGLE F1 ATTACHED El NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE Ec-tre-.0Cv- M(AC V El, I U U_ - ROOF TYPE: PE Pcv -*�^kt4A� DOUBLE TRIPLE DETACHED CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new comm vial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only y65 10 Plans Examiner Zoning Official Fire Marshall 54A k i CORMW /nts: CIS-91 _ F✓ifsSG,-f� Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor, R value of ductwork A/C SEER Rating