HomeMy WebLinkAboutRES2006-01121, 06-1122CA.Q - 11
Off,-�12a
Kim Wolfe Re: Calling for CO @5124 Congressional Dr. Page 1
r
From: Joe Garcia
To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson;
Nicole Cochran; Paul Schoenfeld; Terry Boriskie
Date: 9/14/2006 4:23:19 PM
Subject: Re: Calling for CO @5124 Congressional Dr.
This one is good to go. JMG
>>> Nicole Cochran 09/14/06 12:08 PM >>>
Are there any issues?
BP # 06-1121
Thanks!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.gov
PREPARED 9/14/06, 11:41:29 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/14/06
------------------------------------------------------------------------------------------------
ADDRESS . : 5124 CONGRESSIONAL DR SUBDIV: PEBBLE CREEK
CONTRACTOR T C CUSTOM HOMES PHONE (979) 693-7835
OWNER PEBBLE CREEK DEVELOPMENT CO PHONE
PARCEL 497900-0037-0030
APPL NUMBER: 06-00001121 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/01/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/01/06 CA April 28, 2006 2:00:30 PM kwolfe
early AM - monday
Not Ready For Inspection
B100 02 5/02/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/02/06 AP May 2, 2006 8:12:43 AM bkorthauer
late morning
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 6/27/06 OC BLDG, FRAMING TIME: 17:00
6/27/06 AP June 27, 2006 9:46:08 AM glsouth
June 27, 2006 12:43:22 PM kwolfe
B130 01 7/05/06 OC BLDG, INSULATION TIME: 17:00
7/05/06 AP July 5, 2006 10:01:10 AM malford
B125 01 9 14/06 BI BLDG, FINAL TIME: 17:00
ti September 14, 2006 9:13:43 AM ncochran
------------------------j -------- CONTINUED ONTO NEXT PAGE -----------------------------------
I-L�4� SSG
of
0�1
Date: 9/14/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1121
Address: 5124 CONGRESSIONAL DR
Insp.
Inspection Type Code
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Not Ready For Inspection
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
June 27, 2006 12:43:22 PM kwolfe
E110
ELEC, ROUGH IN
IC
June 27, 2006 12:43:39 PM kwolfe
M100
MECH, ROUGH IN
IC
June 27, 2006 12:44:02 PM kwolfe
P105
PLBG, TOP OUT
IC
June 27, 2006 12:43:49 PM kwolfe
Page 1
I.
WF0761711 / 001 City of College Station
PAGE 1
REQ. DATE:
04/20/06
04/20/06
10:23:32
LOCATION:
5124 CONGRESSIONAL DR
LOC ID:
199738
REQUESTOR:
T C CUSTOM HOMES
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
04/20/06 SCHED
COMPLETION:
04/20/06
********************************************************************************
JOB ORDER RESULT CONV=S
WF0761632 /
001 City of College
Station
PAGE 1
REQ. DATE:
04/20/06
04/20/06
8:27:38
LOCATION:
5124 CONGRESSIONAL DR
LOC ID:
199738
REQUESTOR:
TC HOMES
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
BKORTHAUER AUTH. USER:
BKORTHAUER
WORK TYPE:
ROUT
4" SEWER
TAP AND 3/4" WATER TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
04/20/06 SCHED
COMPLETION:
04/20/06
JOB ORDER RESULT COMMENTS
City of College---S,t-ation
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
9/15/06
497900-0037-0030
5124 CONGRESSIONAL DR
COLLEGE STATION TX 77845
PEBBLE CREEK
PEBBLE CREEK #9-B, BLOCK 37, L
OT 3
SINGLE FAMILY RESIDENTIAL
PEBBLE CREEK DEVELOPMENT CO
Contractor . . . . . . T C CUSTOM HOMES
979 693-7835
Application number 06-00001121 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . .
Approved . . . . . . .
\=B�k�dg Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
Y
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW/PERMIT NUMBER# 6 & _ 11 Z
DATE: (4/ n / o6
BUILDING ADDRESS: ,say Div ,
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing -of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NAT,
2. Moisture barrier indicated on plans
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R.
Overhangs allowed on zero lot line construction up to 18"
S.
T.
Protected openings on walls < three feet from property line
One hour tenant separation to roof deck between duplexes
AIA
III. Stairway Requirements
N K
A.
Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B.
Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C.
Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D.
Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace
Requirements to be indicated onplans)
N
A.
Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C.
Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d Development Servicer
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
Vl. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vlll. Energy Requirements
NArW
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
AMOK
Does not block any water course or divert any flow
Elevation certificate if required
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning c5 Development Services
Comments:
"'A f.
PLANS EXAMINER
DATE
r
TC HOMES
5124 CONGRESSIONAL
2nd FLOOR OPENING SCHEDULE
WINDOW SCHEDULE
PRODUCT CODE
SIZE
COUNT
36X24 PW, 2 by 2
3'-0" x 2'-0"
3
44X&O SH, 2/2
3'-8" x 5'-0"
1
36X(oO SH, 2/2, TWIN
6'-O" x 5'-0"
3
60X12 PW, ROUND TOP
5'-O" x 6'-O"
I
DOOR SCHEDULE
PRODUCT CODE
SIZE
HINGE DIRECTION
COUNT
12x80 BIFOLD, 2 PANEL -ROMAN ARCH
6'-O"
RL
I
28X80, 2 PANEL -ROMAN ARCH
2'-4"
L
3
28X80 2 PANEL -ROMAN ARCH
2'-4"
R
I
32X80 2 PANEL -ROMAN ARCH
2'-8"
L
2
32X80 2 PANEL -ROMAN ARCH
2'-8"
R
I
roOX80 POP, 2 PANEL -ROMAN ARCH
5'-O"
RL
I
28X80 POCKET, 2 PANEL -ROMAN ARCH
2'-4"
N
2
w
TC HOMES
5124 CONGRESSIONAL
let FLOOR OPENING SCHEDULE
WINDOW SCHEDULE
PRODUCT CODE
SIZE
COUNT
4BX48 PW, TEMP, I by 1, CLEAR
4'-0" x 4'-0"
1
36XroO SH, 2/2, TRIPLE
8'-O" x ro'-O"
1
36X-T2 SH, 2/2, TEMP.
3'-0" x -1'-0"
1
36X24 PW, 2 by 2
3'-0" x 2'-0"
2
36X72 SH, 2/2
3'-O" x 1'-0"
3
toOX12 SH, 2/2, TWIN
6'-O" x 6'-O"
2
DOOR SCHEDULE
PRODUCT CODE
SIZE
HINGE DIRECTION
COUNT
32X80 EXT, 2 PANEL -ROMAN ARCH
2'-8"
R
2
36X80 POP, 2 PANEL -ROMAN ARCH
3'-0"
RL
1
28X80 2 PANEL -ROMAN ARCH
2'-41I
L
3
3OX80 2 PANEL -ROMAN ARCH
2'-6"
L
i
32X80 2 PANEL -ROMAN ARCH
2'-8"
R
I
34X80 LOUVERED (UTILITY)
3'-0"
L
I
48X80 PAINT GRADE, POP, DIV LITE
4'-0"
RL
I
r OX80 MAHOGANY, 2 PANEL -ROMAN ARCH w/SL
5'-0"
L
I
36X80 EXT, METAL, FRENCH, I LITE
3'-0"
R
I
192X84 OVERHEAD GARAGE DOOR
18'-3"
N
I
y
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS ,AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 06-00001121 Date 4/19/06
Property Address . .
. . . . 5124 CONGRESSIONAL DR
Property ID:
497900-0037-0030
R #:
R117702
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 288500
Owner
Contractor
------------------------
PEBBLE CREEK DEVELOPMENT
------------------------
CO T C CUSTOM HOMES
% YOUNG, DAVIS
TODD CARNES
4500 PEBBLE CREEK PKWY
230 SOUTHWEST PARKWY E
COLLEGE STATION
TX 778458942 COLLEGE STATION TX 77840
(979) 693-7835
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) DET
HEATED AREA 3106.00
INTERIOR WALL TYPE SHEET ROCK
NUMBER OF BATHROOMS 3.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 419.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
1027.00 Plan Check Fee .00
Issue Date . . . .
4/19/06 Valuation . . . . 288500
Expiration Date . .
10/16/06
Qty Unit Charge
Per Extension
BASE FEE 460.00
189.00 3.0000
THOU BLDG, VAL 100001-500000 567.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
--------
----------
------- ------------
•
BUILDING DERT REPREiENTATIVE y
APPLICANT:
----------------------------
BUILDING DEPX REPRES
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001121
Page 2
Date 4/19/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
----------------- -----
X - --�'---------
KTATIVE:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS ,AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001121
Page 3
Date 4/19/06
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
---------------------------------------------- ---- - -- ---------
BUILDING DEPT REPRESEN ATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . .
06-00001121
Date
4/19/06
----------------------------------------------------------------------------
Special Notes and Comments
RANGE/DRYER DUCT MUST COMPLY
WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical)
WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS.
CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING
ANY WORK
Narrow wall Bracing Fully Sheathed
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 1027.00
1027.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1777.00
1777.00
.00
.00
--------------------------------------------- ---- -- •----------
AA
BUILDING DEPT-,,,REPRESEIJTATIVE :
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-00001122 Date 4/19/06
Property Address . . . . . .
5124 CONGRESSIONAL DR
Property ID:
497900-0037-0030
R #:
R117702
Application type description
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
PEBBLE CREEK DEVELOPMENT CO
------------------------
T C CUSTOM HOMES
% YOUNG, DAVIS
TODD CARNES
4500 PEBBLE CREEK PKWY
230 SOUTHWEST PARKWY
E
COLLEGE STATION TX 778458942
COLLEGE STATION
TX 77840
(979) 693-7835
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc BK
Permit Fee . . . . 20.00
Issue Date . . . . 4/19/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
------------------------------------------- ---- - -------------
BUILDING DEPT \REPRES4NTATIVE I
APPLICANT:
1q,
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning d Development Services
For Office Use Only
DATE: q I & T(RCC REG
APPLICATION #N�y 1 (
TEMP POLE #
ADDRESS/LOCATION: 512-4 CoN69Z-?sSIC NAL- 0 V
LOT _ ' BLOCK,4UBDIVISION fl_--13E3LECft
BUSINESS/OWNER NAME:
PHONE:
(3
CONTRACTOR/HOMEOWNER: t "M Es PHONE: lU "1 J --1635
CONTRACTOR ADDRESS: 2-3 O , W NA`Y L�T I CO ULEC-c SFAM OK , T\� -173,fk)
I
ELECTRICIAN: ?, `'J aF_0?_4L PLUMBER: ASS IPWR61 N6
HVAC: IVkC+g,C-- N A/c, GOOD CENTS (Residential only): N
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: COW-MIX-MON OF 'SNOLU 9SIVI N DWEIUN61
PROPOSED USE: N N(XLE EPS- W U T)W ELLA N161
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE -APPROVAL: 1ES
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ IJ/A
VALUATION: $ 2-BS, '� TOTAL AREA: 3g32 HEATED AREA: NO(O
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
ii
SEWER TAP: 'A
WATER TAP:
OTHER TAP:
R11TEMP POLE
1
GARAGE TYPE
SIZE
Sly
SIZE
SIZE
SINGLE F1
ATTACHED El
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE
Ec-tre-.0Cv-
M(AC V El, I U U_ -
ROOF TYPE: PE Pcv -*�^kt4A�
DOUBLE TRIPLE
DETACHED CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new comm vial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
y65 10 Plans Examiner Zoning Official Fire Marshall
54A k i CORMW
/nts:
CIS-91
_ F✓ifsSG,-f�
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor,
R value of ductwork
A/C SEER Rating