Loading...
HomeMy WebLinkAboutRES2006-01115. 06-1717Cu-ills OU - l `119 1. Inspection Inquiry City of College Station suppon New Windk)w'; Inspection Inquiry 2 - MR-1111F.W. 11 ' 11 :'roperty 10: 582830-0201-0070 )roperty address: 4424 SPRING BRANCH DR Application, structure number 06 00001115 000 000 Permit type, sequence number. BLDG 00 BUILDING PERMIT Inspection type, sequence number e125 000 I eLoG, FINAL Inspection status, date: INSPECTION COMPLETED 12/15/06 Requested date, time, by: 12/14/06 17:00 GS Override date, time, by: User ID to request, result: GILSOUTH GLSOUTH Phone interface number: 985564 Inspector assigned: JGM JOHN MALDORADO Results status, date: APPROVED 12/15/06 Final Inspection flag: Y Penalty amount .00 - - ---------- - - ---- WF0783645 / 001 City of College Station PAGE 1 Hi� 1 • IJ �1 REQ. DATE: 06/05/06 �14 06/05/06 10:08:05 LOCATION: 4424 SPRING BRANCH DR-,. LOC ID: 199484 REQUESTOR: OAKWOOD CUSTOM HOMES �, ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/05/06 SCHED COMPLETION: 06/05/06 ******************************************************************************** JOB ORDER RESULT COMIENTS O -11 l5 WF0782582 / 001 City of College Station PAGE 1 REQ. DATE: 06/01/06 06/01/06 12:35:48 LOCATION: 4424 SPRING BRANCH DR LOC ID: 199484 REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/01/06 SCHED COMPLETION: 06/01/06 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 12/19/06 Parcel Number . . . . . 582830-0201-0070 Property Address . . . 4424 SPRING BRANCH DR COLLEGE STATION TX 77845 Subdivision Name . . . SPRING MEADOWS PH 2 Legal Description . . . SPRING MEADOWS #2, BLOCK 1, LO T 7 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . OAKWOOD CUSTOM HOMES GROUP LTD Contractor . . . . . . OAKWOOD CUSTOM HOMES 979 690-1504 Application number 06-00001115 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone Approved . . . . . . . _J440 A Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6- Development Services PLAN REVIEW/PERMIT NUMBER# _ DATE: BUILDING ADDRESS: yy un I. Foundation Requirements N O A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30") 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N7, 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) N O A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units 17 B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NAAW Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 K Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning d Development Seruicea Comments: PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS u-06 DATE Permit # Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: 0627-4424 SPRING BRANCH Report Date: 03/24/06 Data filename: G:%OAK_DWG106-27-BELMONT10627-4424-SPRINGBRANCH.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11 % Heating Degree Days: 1788 Construction Site: Owner/Agent: Designer/Contractor: 4424 SPRING BRANCH DRIVE Afton Ofczarzak David Park College Sataion, TX 77845 Oakwood Custom Homebuilders LLC. Oakwood Custom Homebuilders U-C 4060 HIGHWAY 6 SOUTH Home Plan design service COLLEGE STATION, TX 77845 4060 Highway 6 South 979-690-1504 College station, TX 77845 plans@oakchb.com 979.690-1504 pWns@oAchb.com 1001. _ Maximum SHGC: 0.40 Your SHGC: 0.33 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, l6" o.c.: sidelkel: Metal Frame:Double Pane with Low-E: SHGC: 0.33 FIXED X2: Metal Frame:Double Pane with Low-E: SHGC: 0.33 SH X9: Metal Frame:Double Pane with Low-E: SHGC: 0.33 HALFROUND: Metal Frame:Double Pane with Low-E: SHGC: 0.33 HS: Metal Frame:Double Pane with Low-E: SHGC: 0.29 FIXED: Metal Frame:Double Pane with Low-E: SHGC: 0.33 SH X2: Metal Frame:Double Pane with Low-E: SHGC: 0.33 FIXED X2: Metal Frame:Double Pane with Low-E: SHGC: 0.33 3PC TRANS: Metal Frame:Double Pane with Low-E: SHGC: 0.33 3068 FRONT DOOR: Solid: 2868 BACK DOOR: Solid: 2868 BACK TO GARAGE: Solid: CONC. SLAB: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' Furnace 1: Forced Hot Air: 78 AFUE Air Conditioner 1: Electric Central Air. 14 SEER 2478 30.0 0.0 87 161 19.0 0.0 8 2996 13.0 0.0 215 6 0.520 3 18 0.520 9 162 0.620 100 4 0.520 2 4 0.560 2 16 0.520 8 48 0.620 30 56 0.520 29 8 0.520 4 20 0.140 3 18 0.140 3 18 0.140 3 249 0.0 259 0627-4424 SPRING BRANCH Page 1 of 6 Compliance Statement_ The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Date Project Notes: LOT 7 BLOCK 1 SEC 1 SPRING MEADOWS NEW BELMONT 0627-4424 SPRING BRANCH Page 2 of 6 "I REScheck Software Version 3.7.3 Inspection Checklist Date: 03/24/06 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: ❑ Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ sidelitel: Metal Frame:Double Pane with Low-E, U-factor: 0.520 For windows without labeled Ufactors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ FIXED X2: Metal Frame:Double Pane with Low-E, U-factor: 0.520 For windows wNhout labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ SH X9: Metal Frame:Double Pane with Low-E, U-factor. 0.620 For windows without labeled U factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ HALFROUND: Metal Frame:Double Pane with Low-E, U-factor: 0.520 For windows without labeled Ufactors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ HS: Metal Frame:Double Pane with Low-E, Ufactor: 0.560 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ FIXED: Metal Frame:Double Pane with Low-E, U-factor: 0.520 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ SH X2: Metal Frame:Double Pane with Low-E, U-factor. 0.620 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ FIXED X2: Metal Frame:Double Pane with Low-E, Ufactor: 0.520 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ 3PC TRANS: Metal Frame:Double Pane with Low-E, U factor: 0.520 For windows without labeled U-factors, describe features: 06274424 SPRING BRANCH Page 3 of 6 #Panes _ Comments: Frame Type Thermal Break? Yes No Doors: ❑ 3068 FRONT DOOR: Solid, U-factor: 0.140 Comments: ❑ 2868 BACK DOOR: Solid, U-factor: 0.140 Comments: ❑ 2868 BACK TO GARAGE: Solid, U-factor. 0.140 Comments: Floors: ❑ CONC. SLAB: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 78 AFUE or higher Make and Model Number: ❑ Air Conditioner 1: Electric Central Air. 14 SEER or higher Make and Model Number. Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Alr Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U factors, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Retum ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-6. ❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ❑ Where exterior walls are used as plenums, the wall must be insulated to R-8. ❑ Insulation is not required on return ducts in basements. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the 0627-4424 SPRING BRANCH Page 4 of 6 heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from nonttepletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. 0627-4424 SPRING BRANCH Page 5 of 6 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (`F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2" Runouts 1" and Less 125" to 2.0" 2.5" to 4" Heating Systems Low Pressurelremperatun: 201-250 1.0 1.5 1.5 2.0 Low Temperature 106 200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) 0627-4424 SPRING BRANCH J J BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION TX 77840 PHONE: (979) 764-35701C: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001115 Date 6/01/06 Property Address . . . . . . 4424 SPRING BRANCH DR Property ID: 582830-0201-0070 R #: R116796 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SPRING MEADOWS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 146520 Owner Contractor ------------------------ ------------------------ OAKWOOD CUSTOM HOMES GROUP LTD OAKWOOD CUSTOM HOMES 4012 SH 6 S ALTON OFCZARZAK COLLEGE STATION TX 77845 4060 SH 6 S COLLEGE STATION TX 77845 (979) 690-1504 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2220.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 410.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 601.00 Plan Check Fee .00 Issue Date . . . . 6/01/06 Valuation . . . . 146520 Expiration Date . . 11/28/06 Qty Unit Charge Per Extension BASE FEE 460.00 47.00 3.0000 THOU BLDG, VAL 100001-500000 141.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT --------INTERRUPTERS) -I- ----------- BUILDING DEPT REPRESENTATIVE: APPLICANT:0,\W 1h BUILDING PERMIT •. CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAk: (979)764-3496 ----------------------------------------------------------------------- Page 2 Application Number . . . . . 06-00001115 Date 6/01/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ., MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET • NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTTPS MUST BE - ------------------------------------------------------- BUILDING D EPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 , FAIC: (979)764-3496 Page 3 Application Number . . . . . 06-00001115 Date 6/01/06 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" A OVE THE FLOOR IN ---------------------------------�-- -- -_- --------- BUILDING DEPT REPRESENTATIVE: APPLICANT: �tl �.b �p BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 - FA$: (979)764-3496 ; -- Page 4 Application Number . . . . . 06-00001115 Date 6/01/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Narrow wall bracing Fully Sheathed with APA garage framing. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ ----------------- Permit Fee Total ---------- 601.00 601.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1351.00 1351.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1/ - - - - - • - - ~ - -------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ' FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001717 Date 6/01/06 Property Address . . . . . . 4424 SPRING BRANCH DR Property ID: 582830-0201-0070 R #: R116796 Application type description TEMP POLE Subdivision Name . . . . . . SPRING MEADOWS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL M Application valuation . . . . 0 Owner Contractor ------------------------ OAKWOOD CUSTOM HOMES GROUP LTD ------------------------ OAKWOOD CUSTOM HOMES 4012 SH 6 S ALTON OFCZARZAK COLLEGE STATION TX 77845 4060 SH 6 S COLLEGE STATION TX 77845 (979) 690-1504 ---------------------------------------------------------------------------- Permit . . . . TEMP POLE PERMIT Additional desc BK Permit Fee . . . . 20.00 Issue Date . . . . 6/01/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - L ----- Z.-•---------- BUILDING DEPT REPRESENTATIVE: APPLICANT APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION t* ff 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning & Dmelopment vrmwa WWW.CSTX.GOV ADDRESS/LOCATION:4424 SPRING BRANCH DRIVE �J 1 For OM UU' Only DATEV� �! �-60C REG APPLICATION# v TEMP POLE # t ` l l LOT 7 ✓ BLOCK 1 86BDIVISION SPRING MEADOWS --- SEC/PH 1 � I BUSINESS/OWNER NAME: ALTON OFCZARZAK PHONE 979-690-2504 I CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-690-2504 I CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845 ELECTRICIAN: CAMPISE ELECTRIC PLUMBER: AGGILAND PLUMBING HVAC: THREE RIVERS GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: NEW CONSTRUCTION STRUCTURE USE: SINGLE FAMILY RESIDENTIAL HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 144j,G30 . / TOTAL AREA:2781 HEATED AREA:2220 (Cost of Labor and Materials) MX PUBLIC SEWER I ❑ SEPTIC/TREATMENT SYSTEM ❑X— SEWER TAP: 4" -1/4 SIZE I ❑X— WATER TAP: SIZE I OTHER TAP: U 1 NUMBER OF BEDROOMS: 4 V NUMBER OF BATHROOMS: 2.5 INTERIOR WALL TYPE: (. t) U EXTERIOR WALL TYPE: 2X4 @ 16" O.C. —+ FOUNDATION TYPE: CONC. SLAB & BEAM 14lut 0icc ` I TEMP POLE ROOF TYPE: 30 YR. COMP SHINGLE - GARAGE TYPE: SINGLE a DOUBLE FX--] TRIPLE ATTACHEDqFTIDIET H D CARPORT El SIGNATURE OF APPLICANT: I. *If proposed work involves new com rcial nstructio facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only F' �4 Plans Examiner Zoning Official CAA-OVS-f 4 Energy Code Compliance Information % Glazing of exterior walls 11 Insulation R value of exterior walls 13 / Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) 19 / Glazing SHGC .33 Glazing U-Factor 62 R value of ductwork A/C SEER Rating 6 14 --/