Loading...
HomeMy WebLinkAboutRES2006-01078, 06-1080%M 7Z PREPARED 9/11/06, 8:09:43 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/11/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 4415 HEARST CT SUBDIV: CASTLEGATE PH 5 SEC 2 CONTRACTOR EASTERLING HOMES PHONE (979) 776-9709 OWNER . . PHONE PARCEL . . 184200-2503-0470 APPL NUMBER: 06-00001078 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT= BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS --- '--------------------------------------------------------------------------------------------- B111 01 6/26/06 OC BLDG, FRAMING TIME: 17:00 6/26/06 AP June 23, 2006 3:12:00 PM kwolfe B130 01 6/27/06 OC BLDG, INSULATION TIME: 17:00 6/27/06 AP June 27, 2006 7:54:23 AM kwolfe Tuesday PM B125 01 9/11/06 BLDG, FINAL TIME: 17:00 81h,/010 P OC-- September 8, 2006 1:00:57 PM kwolfe -------------------------------------- COMMENTS AND NOTES ----------------- ------------------ n `\' ' !vl r k -qo Kim Wolfe - Fwd: Red Calling for CG @ 4415 Hearst Ct _ r w Page 1 ,. From: Terry Boriskie To: Gina Southerland; Kim Wolfe; Nicole Cochran Date: 9/19/2006 2:23:39 PM Subject: Fwd: Re: Calling for CO @ 4415 Hearst Ct Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Joe Garcia 9/13/2006 5:31 pm >>> went by 4415 Hearst, and the box has been replaced. This one is ready to go. JMG >>> Terry Boriskie 09/13/06 12:26 PM >>> Just spoke with Marty and he said he is getting it replaced and you should be able to reinspect at about 2:00 today. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Joe Garcia 9/11/2006 5:13 pm >>> THANKS, JMG >>> Terry Boriskie 09/11/06 4:41 PM >>> Contacted Marty Easterling and he is going to replace the box. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Joe Garcia 9/11/2006 3:06 pm >>> The sewer box that sits over the city side cleanout is broken, and will need to be replaced. It is located on the left side of the property, about 6" behind the back of the curb, and has a green locate flag marking it's location. JMG >>> Nicole Cochran 09/11/06 8:16 AM >>> Are there any issues? Thanks!! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.qov Gina Southerland - Re: Calling for CO @ 4415 Hearst Ct Page 1 From: Joe Garcia To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie Date: 9/11/2006 3:06:28 PM Subject: Re: Calling for CO @ 4415 Hearst Ct The sewer box that sits over the city side cleanout is broken, and will need to be replaced. It is located on the left side of the property, about 6" behind the back of the curb, and has a green locate flag marking it's location. JMG >>> Nicole Cochran 09/11/06 8:16 AM >>> Are there any issues? Thanks!! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov WF0761867 / 001 City of College Station 1 PAGE 1 OCR -I oqt � REQ. DATE: 04/20/06 04/20/06 14:42:42 LOCATION: 4415 HEARST CT LOC ID: 204080 REQUESTOR: EASTERLING HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/20/06 SCHED COMPLETION: 04/20/06 ******************************************************************************** JOB ORDER RESULT CONIlMI'S WF0760979 / 001 City of College Station PAGE 1 REQ. DATE: 04V18/06 04/18/06 15:32:21 LOCATION: 4415 HEARST CT LOC ID: 204080 REQUESTOR: EASTERLING HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH.- USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/18/06 SCHED COMPLETION: 04/18/06 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE.STA.TION, TX 77840 PHONE: (979) 76a4-=3"S�0 FAX: (979) 764-3496 -------------------------------- .s----------------------------------------- Application Number . . . . . 06-00001078 Date 4/18/06 Property Address . . . . . 4415 HEARST CT Property ID: 184200-2503-0470 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 160776 Owner Contractor ------------------------ ------------------------ EASTERLING HOMES MARTY EASTERLING P 0 BOX 6436 BRYAN TX 77805 (979) 776-9709 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE 2*4 STUD IMPACT/PRORATA FEES PAID PAID FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 3312.00 INTERIOR WALL TYPE 2*4 STUD NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 643.00 Plan Check Fee .00 Issue Date . . . . 4/18/06 Valuation . . . . 160776 Expiration Date . . 10/15/06 Qty Unit Charge Per Extension BASE FEE 460.00 61.00 3.0000 THOU BLDG, VAL 100001-500000 183.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ----------------------------- BUILDING DEPT REPRESENTATIVE: ------ --- --'- - ------------ • APPLICANT: �� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-357r0 FAX: (979) 764-3496 Application Number . . . . . 06-00001078 Page 2 Date 4/18/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE - --------- ------ ----- ------------------------ ----- --- ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3510 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00001078 Date 4/18/06 ---------------------------------------------------------------------------- Special Notes and Comments POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS Add smoke detector outside gameroom because room has bedroom characteristics because of closet with rod hanger. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall bracing fully sheathed with APA framing at --------------------------------------------------- --- - -- ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001078 Date 4/18/06 ---------------------------------------------------------------------------- Special Notes and Comments garage area ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 643.00 643.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1393.00 1393.00 .00 .00 -------------------------------------- --------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: J TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-357'0 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001080 Date 4/18/06 Property Address . . . . . . 4415 HEARST CT Property ID: 184200-2503-0470 R #. Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ EASTERLING HOMES MARTY EASTERLING P O BOX 6436 BRYAN TX 77805 (979) 776-9709 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc BK Permit Fee . . . . 20.00 Issue Date . . . . 4/18/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: i APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WW W.CI.COLLEG ESTATION.TX.US ADDRES /LOCATION: LOT Y�j BLOCK BUSINESS/OWNER NAME: CONTRACTOR/HOMEOW� CONTRACTOR ADDRESS: ELECTRICIAN: &fizac) viv'rw HVAC: l Fa Office Use pry 4 DATE: ` I0 ( APPUCAnoN a _)LSL- LO-� TEMP POLE # I O ' I Q PLUMBER: &La'5 10Lom'swo GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: �1 �,(� kEsi AF Aa& STRUCTURE USE: HOMEOWNER ASSOCIA OR DESIGN REVIEW COMMITTEE APPROVAL: VIJ �u TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ / I PC), lLP . DQ_v'TOTAL AREA:,)HEAT D AREA: (Cost of Land Materials) 01PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: ' INTERIOR WALL TYPE: �E � WATER TAP: sl�EXTERIOR WALL TYPE: fff��'� SIZE OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE DOUBLE06 TRIPLE a ATTACHED /AETACHEI�, o ( CARPORT a SIGNATURE OF APPLICANT: A V, ' Official Use Only ents: YEZor NO /,,I,, Plans Examiner Zoning Official 444 S A ��►cv er- � i c=1-I, c S Energy Code Compliance Information % Glazing of exterior walls (P Insulation R value of exterior walls �I.� / Insulation R value of ceiling 1 (flat areas) A9-3D Insulation R value of ceiling 2 (vaulted areas/no attic) LP Glazing SHGC / Glazing U-Factor LP R value of ductwork A1C SEER rating y CITY OF COLLEGE STATION Planning c4 Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# OG - D7 $ 1 DATE: y l iile6 BUILDING ADDRESS: I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning c5 Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N A7 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes A III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated onplans) A. Hearth extensions i 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Mason fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than an portion of the buildingwithin ten 10 feet horizontal • PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Development Services V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage V11. Mechanical Requirements NA/ K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy Requirements NAAtV A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N O Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required ;t CITY OF COLLEGE STATION Planning d' Development Services Comments: PLANS EXAMINER • PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS DATE