HomeMy WebLinkAboutRES2006-01056, 06-1057bu . ImRo OPendaffe)C /3Esselte R 7521/3 10% P4 . PREPARED 12/14/06, 7:47:58 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/13/06 -------------------------------------------------------------------------------------- ADDRESS . : 3908 CROWN RIDGE CT SUBDIV: CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0409-0050 APPL NUMBER: 06-00001056 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/10/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/10/06 AP May 10, 2006 8:45:36 AM kwolfe Strings On Setbacks O.K. Slab Ground Installed B115 01 7/17/06 RH BLDG, FRAMING TIME: 17:00 7/17/06 AE July 17, 2006 1:58:14 PM kwolfe 07/17/2006 03:11 PM RH PDA Need anchors at doors and splices by insulation. B1-30 01 7/19/06 OC BLDG, INSULATION TIME: 17:00 7/19/06 AP July 19, 2006 9:51:16 AM bkorthauer B132 01 7/25/06 RH BLDG, SHEETROCK FASTENER TIME: 17:00 7/25/06 DP July 25, 2006 11:41:24 AM bkorthauer 07/25/2006 03:22 PM RH PDA Nailing pattern exceeds 7 inches O.C. B132 2,.. 7/26/06 JGM BLDG, SHEETROCK FASTENER TIME: 17:00 7/26/06 AP July 26, 2006 8:07:03 AM kwolfe B125 01 :12/13/06 ,/�/� BLDG, FINAL TIME: 17:00 ahv&co /x�" OC- December 13, 2006 1:48:59 PM ncochran. -------------------------------------- COMMENTS AND NOTES-------------------------------------- Kim Wolfe Re Calling for CO @ 39Crown Ridge Ct age _ _..,, ..._,P.. 1 08 From: Joe Garcia To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie Date: 12/14/2006 4:05:32 PM Subject: Re: Calling for CO @ 3908 Crown Ridge Ct THIS ONE IS OK. JMG >>> Kim Wolfe 12/14/06 8:24 AM >>> Are there any issues? BP # 06-1056 Thanks Kimberly Wolfe City of College Station Planning & Development Services (979) 764-3570 www.cstx.gov Date: 12/14/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1056 Address: 3908 CROWN RIDGE CT Insp. Type Inspection Type Code Insp. status Description B100 BLDG, FOUNDATION -SLAB IC B100 BLDG, FOUNDATION -SLAB IC B115 BLDG, FRAMING IC B115 BLDG, FRAMING IC B132 BLDG, SHEETROCK FASTENER IC B132 BLDG, SHEETROCK FASTENER IC Page 1 Date: 12/14/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1056 Address: 3908 CROWN RIDGE CT Inspection Result Comments Strings On Setbacks O.K. Slab Ground Installed 07/17/2006 03:11 PM RH PDA Need anchors at doors and splices by insulation. 07/25/2006 03:22 PM RH PDA Nailing pattern exceeds 7 inches O.C. . Page 1 b WF0787224 / 001 City of College Station PAGE 1 REQ. DATE: 06/14/06 06/14/06 11:15:37 LOCATION: 3908 CROWN RIDGE CT LOC ID: 203728 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 06/14/06 SCHED COMPLETION: 06/14/06 ******************************************************************************** JOB ORDER RESULT COMMENTS W-1 WF0759160 / 001 City of College Station PAGE 1 .: 4f REQ. DATE: 04/10/06 04/10/06 16:00:26 LOCATION: 3908 CROWN RIDGE CT LOC ID: 203728 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/4" TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/10/06 SCHED COMPLETION: 04/10/06 ******************************************************************************** JOB ORDER RESULT COM U94TS City of College Station 1101 TEXAS-ZyXNUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . 12/15/06 005401-0409-0050 3908 CROWN RIDGE CT COLLEGE STATION TX 77845 WESTFIELD VILLAGE PH 4 BLOCK 9 LOT 5 PLANNED DEVL HOUSING Contractor . . . . . . STYLECRAFT BUILDERS 979 690-1222 Application number 06-00001056 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . Approved . . . . . . NV--, &ft A . pf Bdildi6fa Officia VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT . CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX_7�78;0 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001056 Date 4/10/06 Property Address . . . . . . 3908 CROWNRIDGE CT Property ID . . 005401-0409-0050 R# . . . . . . . . . . . . . Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 91740 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1390.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 428.00 Plan Check Fee .00 Issue Date . . . . 4/10/06 Valuation . . . . 91740 Expiration Date . . 10/07/06 Qty Unit Charge Per Extension BASE FEE 260.00 42.00 4.0000 THOU BLDG, VAL 50001-100000 168.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-FRAMED SIZE 2211 ---------------------------------- ------ --- - ------------- BUILDING DEPT REPRESENTATIVE: • APPLICANT'; -T� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001056 Page 2 Date 4/10/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - iL - - - - - - - - - - _ _ _ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, T� 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001056 Page 3 Date 4/10/06 Special Notes and Comments THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow Wall bracing by Engineered Methods. Other Fees . SEWER TAP 4" WATER TAP 3/4" 350.00 400.00 Fee summary Charged -------------------- Paid Credited -------------------- Due ----------------- Permit Fee Total 428.00 428.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1178.00 1178.00 .00 .00 --------------------------- ----- ---- - -- ------------- BUILDING DEPT REPRESENTATIVE: • APPLICANT. BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001056 Page 4 Date 4/10/06 --------------------------- ---- -- - ; ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, T�, 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001057 Date 4/10/06 Property Address . . . . . . 3908 CROWN RIDGE CT Property ID . . . . . . . . . 005401-0409-0050 Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor - ----------------------- ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 4/10/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - • - - s - - - - - - - - - - - - BUILDING DEPT REPRESENTATIVE: Ai; APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE (*Or" COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Xwningd^DcerlopmentServices WWW.CSTX.GOV 4RCC only DATEL' REG APPLICATION # a • 1 U- TEMP POLE # t) W * I llV� J ADDRESS/LOCATION: OS CQ0W KX � e a. LOT '� BLOCK Ct '� SUBDIVISION t SEC/PH / BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp ' GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framina STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: IV /T TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ O -740 TOTAL AREA: 1O11-1 HEATED AREA: I'?19 D (Cost of Labor and Materials) '40- /� DX PUBLIC SEWER SEPTIC/TREATMENT SYSTEM �X SEWER TAP: XX WATER TAP: �j� OTHER TAP: TEMP POLE GARAGE TYPE: 1 4' SIZE g/n SIZE SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: Z INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition SINGLE F__] DOUBLE F-1 TRIPLE ATTACHED X� DETACHED F__] CARPORT SIGNATURE OF APPLICANT: For St lecraft *If proposed work involves new commercial constrLYction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Plans Examiner Zoning Official ents. E rNO eY y Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating to R13 R30/ R19� .40� .65 R6 13 n CITY OF COLLEGE STATION Planning er Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# (. _ /n$-(o DATE: z1 1,7 l06 BUILDING ADDRESS: gGOQ (fe,-,Jj NI've CA. I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA'r 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes q III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated onplans) OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions- 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6- Development Services V. Electrical Service Requirements NAdMj A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street �11 Subdivision Regulations — Ordinance 690 JO Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 Does not block any water course or divert any flow Elevation certificate if required N /� !" PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services Comments: A.�L-L- y -- .7 - (36 PLANS EXAMINER DATE REScheck Compliance Certificate 2003 IECC REScheck Software Version 3.6 Release 2 Data filename: S:\ACAD\Archived\Old REScheck\1393_10148 Bunting.cck PROJECT TITLE: Plan # 1393 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.11 DATE: 04/04/06 DATE OF PLANS: 04-04-2006 PROJECT DESCRIPTION: Spec 3908 Crown Ridge Ct. College Station, Texas DESIGNER/CONTRACTOR: Stylecrall Builders, hie. 4090 St. Hwy. 6 S. College Station, Texas 77845 (C6lv1PLIANCE.:-P9ses1 Maximum UA = 550 Your Home UA = 456 17.1% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Slab -On -Grade: Unheated Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R Value -Val e - act r Ji 245 30.0 0.0 9 1145 19.0 0.0 60 1344 13.0 0.0 95 135 0.670 90 38 0.500 19 18 0.440 8 168 0.0 ' 175 Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer 9Qu(a�1- Date 4- p (0 RES check Inspection Checklist 2003 IECC REScheck Soilware Version 3.6 Release 2 DATE: 04/04/06 PROJECT TITLE: Plan # 1393 Bldg. Dept. Use [ ] [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe matures: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor. 0.500 Comments: 2. Door 2: Glass, U-factor. 0.440 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number [ ] 2. Furnace 2: Forced Hot Air, 80 AFUE or higher I Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: Minimum insulation requirement for skylight shaifs equal to or greater than 12 inches is R-13. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [ ] Supply ducts in unconditioned spaces must be insulated to R-6. [ ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. [ ] Where exterior walls are used as plenums, the wall must be insulated to R-8. Insulation is not required on return ducts in basements. Duct Construction: Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 18113. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). The HVAC system must provide a means f3r balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the I levels in Table 2. Table]: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pine Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature (Fl Un to 1„ Un to 1.25" 1.5" to 2.0" Over " 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pining System Types Ranee ( Fl 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled Water, Refrigerant, and Brine 201-250 1.0 1.5 1.5 2.0 106-200 0.5 1.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Assembly Type MMIMIMMOMM Description - C �� , .. 0�■�■ .. �® , . , _ ©� .., - .. off■ . , � „ „ ® , . , � Window Area Total: 135.33 04/04/06 11:07:43 1/1 Area Calculator: Assembly Type comments/ Description Opaque door solid masonite Door Area Total: 55.56 04/04/06 11:07:44 1 /1 Area Calculator: Assembly Type Comments/Description Ceiling Area Total: 1390.00 04/04/06 11:07:44 1 /1 Area Calculator: Assembly Type Comments/Description m �■�■ems Exterior Wall Area Total: 1344.00 04/04/06 11:07:44 1 /1 Area Calculator: Assembly Type Comments/Description Floor Area Total: 0.00 04/04/06 11:07:44 1 /1