Loading...
HomeMy WebLinkAboutADDN2006-01051DCo ! 0C5l r U OPendaflme- /3 Esselte R 7521/3 10% P4 .J A BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 778,40 PHONE: (979) 764-3570 ;FAAX�:,- (979) 764-3496 -------------------------------------------- -------------------------------- Application Number . . . . . 06-00001051 Date 4/12/06 Property Address . . . 8307 SHADOW OAKS Property ID: 249000-1017-0040 R #: R96223 Tenant nbr, name . . . . . . ADD SUNROOM Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . EMERALD FOREST #10 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 41000 Owner Contractor ------------------------ ------------------------ ANAND, NAGAMANGALA K & VEENA BORSKI HOMES 8307 SHADOW OAKS 3006 E. 29TH COLLEGE STATION TX 778454614 BRYAN TX 77802 (979) 776-5852 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 1.00 INTERIOR WALL TYPE DRYWALL SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc GS Permit Fee . . . . 215.00 Plan Check Fee .00 Issue Date . . . . 4/12/06 Valuation . . . . 41000 Expiration Date . . 10/09/06 Qty Unit Charge Per Extension BASE FEE 15.00 40.00 5.0000 THOU BLDG, VAL 1001-50000 200.00 -------------------------------------------- 7------------------------------- Special Notes and Comments PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED ------SILL PLATES • --��QN�------------ BUILDING DEPTr RJ�PRESENTATIVE�: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 ; FAX.:+, (979) 764-3496 Page 2 Application Number . . . . . 06-00001051 Date 4/12/06 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall bracing of addition to be ully sheathed ------------------------------------------- Fee summary Charged Paid C di -Due --------------------------------------- -- -�----------- - .- BUILDING I�BPT-_,REPRESENTATIVE: APPLI BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 , FAX:. (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . ----------------- ---------- Permit Fee Total 215.00 Plan Check Total .00 Grand Total 215.00 06-00001051 -------------------- 215.00 .00 .00 .00 215.00 .00 Page 3 Date 4/12/06 .00 .00 .00 --------------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT For LYEe we ony APPLICATION FOR BUILDING PERMIT DATE: 4 6-07TRCC REG (w CITY OF COLLEGE STATION f Q 5'' 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 APPLICATION # TEMP POLE # C17Tffy OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX planning d,Drwhpmnvr Stretiaa WtNW.csTX.(iOv ADDRESSILOCATION: 8-;%7 S�1a&sk "KS, . LOT � BLOCK 1 `7 SUBDIVISION Eme cLIQ %met i SEC/PH t �/ BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: EOtSVc1 UOYYles. Inc.. PHONE: " 1(a-6$52 CONTRACTOR ADDRESS: arnica QLOO brVQY1 71bo-2 ELECTRICIAN: AtllCp Eltc. PLUMBER: HVAC: --AAA G� GOOD CENTS (Residential ony): CLASS OF WORK ESSORY/STORAGE LOCATION RE -ROOF �:9_40UTION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Acker a. ln.cweNta rear Ae. e xt04m'a res.devce- -6, re> kam w ua d ec STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 411600 . 010 -� TOTAL AREA: 2 aq HEATED AREA: (Cost of Libor and Materials) PUBLIC SEWER SEPTIC17REATMENT SYSTEM SEWER TAP: WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: -------- ft SIZE SIZE SIZE SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE �2« airvuL�atl � 2 x 4 �r't+r1F.. ve�ne�eY FOUNDATION TYPE: l�j ah Chem ROOF TYPE: DOUBLE TRIPLE Q DETACHED CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commercial coast ction r facade improvements/renovations to an existing commercial property, building elevations are require Official Use Only y- 2 -a Plans Examiner Zoning Official ments. ES r NO Energy Code Compliance lnformadon - tj5eeJ�,iqn_s % Glazing of exterior walls AJA _ Insulation R value of exterior walls 13 Insulation R value of ceiling 1(flat areas) 3� Insulation R value of ceiling 2 (vaulted areas/no attic) / % Glazing SHGC o Glazing U-Factor 7S R value of ductwork A/C SEER Rating &rJ PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW/PERMIT NUMBER# 66 _ DS DATE: q16, /o6 BUILDING ADDRESS: 30 1QLJ d I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated A' II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. N. Span exceeding code tables must be engineered Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services 11. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes 4- III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated onplans) K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY (*hrq" OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6' Development Services V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements OK A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements MUM A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy Requirements A/ A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed AIA Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required l�� !� '-f PLAN REVIEW ONE and TWO FAMILY (*hrq" OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Development Services Comments: PLANS EXAMINER DATE PAGE 62 a +4, 81p 17, P +a io E serald 'Forest gu4divislon, CiAlige. "Station, Bros, TX 11 -411 <V Borski Homes Inc. 4 979/776-5852 $006 East 29th Bryan, Texas 77802 www,borWhomes.com