HomeMy WebLinkAboutRES2006-01039, 06-1040l�-l039
G.Ioqo
OPendafielC
/3Esse/%
R 7521/3 10%(D P4
WF0764622 / 001 City of College t.,ipn
PAGE 1
REQ. DATE: 04/28/06�U�04/28/06 15:32:07
LOCATION: 1101 WAYNESBORO CT a� LOC ID: 201784
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
TASK: SET UP NEW UTILITY ACCT SETS READY
SCHED START: 04/28/06 SCHED COMPLETION: 04/28/06
********************************************************************************
JOB ORDER RESULT COMIlI TTS
WF0758744 / 001 City of Co,"��ege Station
F
r
PAGE 1
REQ. DATE:
04/07/06
04/07/06
14:28:45
LOCATION:
1101 WAYNESBORO CT
LOC ID:
201784
REQUESTOR:
ED FROEHLING BUILDER ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/07/06 SCHED COMPLETION:
04/07/06
********************************************************************************
JOB ORDER RESULT COMMEATTS
BUILDING PERMIT
CITY ieFl4LLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------=---------------------------------------------
Application Number
06-00001039 Date 4/07/06
Property Address . .
. . . ..1,1101 WAYNESBORO CT
Property ID:
569500-1337-0100
R #:
R301818
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . SHENANDOAH PH 13
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 164010
Owner
Contractor
------------------------
FROEHLING, EDWARD
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
ED FROEHLING
COLLEGE STATION
TX 778459443 3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2485.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 5.00
SEWER TYPE PUBLIC
TAZ 422.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
655.00 Plan Check Fee .00
Issue Date . . . .
4/07/06 Valuation . . . . 164010
Expiration Date . .
10/04/06
Qty Unit Charge Per Extension
BASE FEE 460.00
65.00 3.0000 THOU BLDG, VAL 100001-500000 195.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
----- --- - ------------
BUILDING D`EPPT REPRESENTATIVE:
APPLICANT: _lMr��lA1q F4
BUILDING PERMIT
CITY•OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001039
Page 2
Date 4/07/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
--------------------------- ----- --- --'-------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: ��in11,1// l r/2 n
BUILDING PERMIT
CITY -OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001039
Page 3
Date 4/07/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
-------------------------------------- - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT: �-63�'M&7 ram
BUILDING PERMIT
CITY•OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number
. . . . .
06-00001039
Date
4/07/06
----------------------------------------------------------------------------
Special Notes and
Comments
PRIVATE GARAGES
Narrow wall bracing
Fully Sheathed
with APA
garage framing
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
655.00
655.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1405.00
1405.00
.00
.00
---------------------
- ---- --- ---'----------------
BUILDING DEPT REPRESENTATIVE: -- -- ---
APPLICANT:,-0i VfmM VAA�
TEMPORARY POLE PERMIT
CITY'OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . .
06-00001040 Date
4/07/06
Property Address .
. . . . .
1101 WAYNESBORO CT
Property ID:
569500-1337-0100
R #:
R301818
Application type description
TEMP POLE
Subdivision Name .
. . . . .
SHENANDOAH PH 13
Property Use . . .
. . . . .
RESIDENTIAL
Property Zoning . .
. . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
FROEHLING, EDWARD
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
ED FROEHLING
COLLEGE STATION
TX 778459443
3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/07/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE
APPLICANT :l�I l r1m PA11
'01
CITY OF COLLEGE STATION
Pknning & Development Servicef
ADDRESS/LOCATION
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
C'W PT '-�
1%01
For office use Only
DATE: � - G. b(ARCC REG
APPLICATION #D /� 1 D
TEMP POLE #
LOT 10'" BLOCK SUBDIVISION cS Av4AN DCA1R "
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS:
PHONE: (PHONE: IMP- Q Z60
ELECTRICIAN: PLUMBER: t RlP(r=- S
HVAC: 'J� GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION_,MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: d�v I t, C Le
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIB97(o
STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 4) 010. 00v-1 TOTAL AREA: 31 t(p HEATED AREA: 24Q05
(Mt of Labor and Materials)
N PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
�r
SEWER TAP:
2'WATER TAP:
3A"
SIZE
OTHER TAP:
MOOTEMP POLE
GARAGE TYPE
JILt
SINGLE
ATTACHED
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE
ROOF TYPE:
DOUBLE TRIPLE
IEETACHECt FI CARPOR
SIGNATURE OF APPLICAOT:
*If proposed work involves new commer onsl
commercial property, building elevations a
Plans Examiner
t4jl ff
or facadeim
,Ficial Use Only
Zoning Official
C ments:
YE or NO
J IJSEr��
Ct---> Vz IC -IC_
� c�1C�Rf�r
`1 or
0
/CQ
to an existing
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls 2 .ZZ &70
Insulation R value of exterior walls 13
Insulation R value of ceiling 1 (flat areas)
W ✓
Insulation R value of ceiling 2 (vaulted areas/no attic)
N /A ✓
Glazing SHGC
Glazing U-Factor
• ��
R value of ductwork
A/C SEER Rating
1-5
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning cr Development Services
PLAN REVIEW/PERMIT NUMBER# o 6 _ 103S
1 DATE: 14 /s- /o4
BUILDING ADDRESS: I 10 I "', es bflra
M
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
jyr
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/ VX)
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
It
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning c5 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NJ,
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
Na
III. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than tweet -six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated onplans)
A/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d Development Services
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VI1. Mechanical Requirements
NA/ K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
K
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
y-S--0(
DATE
I
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\l 117PB.rck
TITLE: 1101 Waynesboro Court
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/04/06
DATE OF PLANS: 8/13/05
PROJECT INFORMATION:
Lot 10 Block 37
Shenandoah Phase 13
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
HOME FOR OSTIQUINS
5-BED WITH BOXED BAY WINDOWS
COMPLIANCE: Passes
Maximum UA = 780
Your Home UA = 603
22.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Wall l: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 90 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 90 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2485
30.0
0.0
87
396
15.0
0.0
22
73
0.600 44
38
516 15.0 0.0
55
396 15.0 0.0
0.400 15
35
0.600 33
24
fl
Window 3: Metal Frame:Double Pane with Low-E 68 0.600 41
SHGC: 0.40
Bldg. faces 90 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 90 deg. from North; Comp. orient.: Back
Projection factor: 1.02
Wall 4: Wood Frame, 16" o.c. 516 15.0 0.0 38
Window 4: Metal Frame:Double Pane with Low-E 27 0.600 16
SHGC: 0.40
Bldg. faces 90 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated 228 0.0 238
Insulation depth: 0.0'
Air Conditioner 1: Electric C ntral Air, 13 SEER
COMPLIANCE STATEME T: The proposed building design described here is consistent with the building plans, specifications,
and other calculations subm tted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheck ersion 3.5 Release I (formerly MECchec4 and to comply with the mandatory requirements listed in
the RES checkInsp n cklist.
Builder/Des' er Date 0�
.r r tr, � a ��c,�v ,lsr✓RVFr�,�o, /we, W~rAmf s s >o. • c� .� r rra rr�� �
Lot 10 Block 37.awg
I Lot 9 Lot a r
Now or Formed -iy
Ed Froahling Builder, _ Inc. Ed Froahling Builder, InC.
�•�• Vol. 8580. Pg. 214 1 Vol. 8580, Pg. 214
1 i
I
! 20' P.U.E. 1
Note: Building Setback Unes per a
tat City of College Station Unified
fDovelopryient Ordinance 12817
.._.._.._.._.._..__.._.._.._.._
a 49-5"
ja .81oak I
f \ h Pb� •5r
I j \ Sher�vnc��
v` era
.o
¢1 r
proposed.i;
Residence
,.;
------------
\ gi.
tq
Scale.1' 20'
Edward ng �
Rer*+vintlm 49.3 of 4B.J6 Acme
Vol. 4248, Pg. 144
G'LEVE T®&F
CURVE DELTA RADIUS LENGTH CHORD. 8RC.
Cl 87'104- 50.W 58.70' S 11'48'28" W
tack/Cv,'b
v WWn 1esboro Court
I 50R.o,W. N 27' Pammot
Vol WO, Pf;. 214
l