HomeMy WebLinkAboutADDN2006-01033Ob • 1063,
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F C O M P L E T I O N
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
4/18/07
2000 MOSES CREEK CT
COLLEGE STATION TX 77845
WILLIAMS CREEK PH 1
WILLIAMS CREEK PH 1
BLOCK 2
LOT 9
RURAL RESIDENTIAL SUB.
H L C HOMES LLC
979 696-9049
Application number 06-00001033 000 000
Description of Work RESIDENTIAL, ADDITION
Construction type . . . **NEEDS TO BE ENTERED**
Occupancy type . . . . **NEEDS TO BE ENTERED**
Flood Zone . . . . . .
Approved . . . . . . .
B ilding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED
4/17/07, 11:42:50
INSPECTION TICKET
PAGE 2
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 4/17/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 2000 MOSES CREEK CT
SUBDIV: WILLIAMS CREEK PH
1
CONTRACTOR
H L C HOMES LLC
PHONE (979) 696-9049
OWNER
PHONE
PARCEL
- -
APPL NUMBER: 06-00001033 RESIDENTIAL, ADDITION
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01
4/11/06 OC
BLDG, FRAMING TIME: 17:00
4/12/06 AP
April 11, 2006 8:36:27 AM bkorthauer
April 12, 2006 9:01:29 AM kwolfe
Stairs leading to upstairs media room at base
of stairs
width was allowed to be 27" in wide being the
minimum
allowed. Per Chris and Terry
B130 01
4/13/06 JGM
BLDG, INSULATION TIME: 17:00
4/13/06 AP
April 12, 2006 11:43:20 AM bkorthauer
late afternoon
B125 01
3/08/07 JGM
BLDG, FINAL TIME: 17:00
3/08/07 DP
March 7, 2007 8:54:22 PM glsouth.
Need Address
B125 02
4/ 7/07'� BI
BLDG, FINAL TIME: 17:00
�/ �%
April 17, 2007 9:33:51 AM ncochran.
IT-IS-LOCKED;CALL7-979-412-5483_IF-YOU-NEED.TO
_
GO_INSIDE7
----------------------
----------
I
_ -- ----
COMMENTS AND NOTES--------------------------------------
Date: 3/8/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1033
Address: 2000 MOSES CREEK CT
Type
Inspection Type Code
status
Inspection Result Comments
Description
B115
BLDG, FRAMING
IC
April 12, 2006 9:01:29 AM kwolfe
6115
BLDG, FRAMING
IC
Stairs leading to upstairs media room at base of stairs
B115
BLDG, FRAMING
IC
width was allowed to be 27" in wide being the minimum
B115
BLDG, FRAMING
IC
allowed. Per Chris and Terry
E110
ELEC, ROUGH IN
IC
April 10, 2006 12:40:14 PM kwolfe
P105
PLBG, TOP OUT
IC
October 18, 2006 4:37:52 PM kwolfe
Page 1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS .AVF_'
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00061033 Date 4/04/06
Property Address . . . . . . 2000 MOSES CREEK CT
Property ID . . . . . . . . . - ' -
R # R*****
Application type description RESIDENTIAL, ADDITION
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 23800
Owner Contractor
------------------------ ------------------------
H L C HOMES LLC
LEON COUCH
203 HWY 21 WEST
CALDWELL TX 77836
(979) 696-9049
--- Structure Information 000 000 ADDITION
Construction Type . . . . . **NEEDS TO BE ENTERED**
Occupancy Type . . . . . . **NEEDS TO BE ENTERED**
Other struct info . . . . . IMPACT/PRORATA FEES PAID NA
HEATED AREA 341.00
TAZ 329.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc GS
Permit Fee 130.00 Plan Check Fee .00
Issue Date . . . . 4/04/06 Valuation . . . . 23800
Expiration Date . . 10/01/06
Qty Unit Charge Per Extension
BASE FEE 15.00
23.00 5.0000 THOU BLDG, VAL 1001-50000 115.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
-----------------
BUILDING
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE-
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00001033 Date 4/04/06
----------------------------------------------------------------------------
Special Notes and Comments
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
Refer To This Permit For Details For This Plan
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
BUILDING DE
APPLICANT:
130.00 130.00 .00 .00
.00 .00 .00 .00
130.00 130.00 .00 .00
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Plann n 8 c'Devdo F meeeSe ica
For Office Use Only
DATE: L� ` 4 VARCC REG
APPLICATION # o W ' I o 33
TEMP POLE #
ADDRESS/LOCATION:
LOT BLOCK_ SUBDIVISION L� �� y�yy1 �Sl�'� SEC/PH_�
BUSINESS/OWNER NAME: „ C� PHONE:
CONTRACTOR/HOMEOWNER: ? _�L0(.D C'C1t ref PHo E:
CONTRACTOR ADDRESS: 3
ELECTRICIAN:�PLUMBER: I Y I CGLI CI Fib%
HVAC: r4 01Z62 0 4=2 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: rm6.l. A (33),) Lt.s P-Vvk- ,
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 0l3 i X TOTAL AREA: 3W HEATED AREA:
(Cost of L bor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS: /— A
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 6
IZE
WATER TAP:
SIZE
OTHER TAP:
'SIZE
TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
NUMBER OF BATHROOMS: A_J 6
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
DETACHED
TRIPLE
:ARPORT
*If proposed work involves ew merciarco ructi6Pibr dd- e i rovements/renovations to an existing
commercial property, buil ' elevations are rEfquired.
Official Use Only
Plans Examiner Zoning Official Fire Marshall
ents:
Y S r NO
Energy Code Compliance Information
% Glazing of exterior walls M-
Insulation R value of exterior walls 1.9
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC AJ4
Glazing U-Factor
R value of ductwork
A/C SEER Rating !�'