HomeMy WebLinkAboutRES2006-01029ou • tnaal
z.
OPendaflOir
aEsse/%
R 7521/3 10%'$P4
Brazos County Health Department
N0, 0934 P. 2
Brazos County Health Department
_2jt rth Texas Ave.
Bryan, TX 77803-5317
(979) 361-4440 cc 00 F,
LICENSE TO OPERATE AN ON SITE SEWAGE FACILITY
THIS IS TO CERTIFY that the on site sewage facility owned by: OSSF #: 2006 - 2882
ELH-ELEGANT LIVING HOMES
JOHNSON CREEK LOOP 4702, College Station TX 77845 Grid:
WILLIAMS CREEK
Block: 1 Lot: 2 Certificate of Compliance: IN C.S.
Installed By: WAGER, JAY C.-WAGER BACKHOE Bedrooms: 4
Engineered By: GONZALEZ, STEVEN- PREMIER ENVIRONMENTAL DESIGNS Employees: 0
Gate Purchased: 06/21106 Final Inspection Date: 07/14/06 MaxGPD: 433
Disinfectant: Liquid Chi
The private sewage facility licensed above was installed according to the current and
minimum guidelines of the Texas Commission on Environmental Quality (TCEQ) and
Brazos County.
This aerobics stem with s-pray dispersal requires a disinfectant for final treatment of the
sprayed effluent. It is the responsibility of the homeowner to monitor the disinfectant
and to add more when needed. (Swimming pool chlorine tablets are not acceptable
substitutes). Under no circumstance are any food crops or edible foods to be grown in
the spray area. Mowing of the sprayfield on a regular basis, should also be done to help
with the evaporation process.
The current maintenance contract for this system will expire 2-years from the above final
inspection date. A new maintenance contract must be in force at that time, and a copy of
the new contract filed with this office 30 days before contract expires.
This is a NON-TRANSFER.A13LE license. Upon transfer of ownership, the new owner
shall be required to transfer the original license into his/her name. Should the system
malfunction in the future, it will be the licensee's responsibility to bring the system in
compliance with all current state and county regulations.
This license does not extend to the material's, workmanship, or fabrication, of the
system, so as to expressly or impliedly grant the owner, or installer of the system any
warranty by / or rights against Brazos County and / or the Brazos County Health
Departnnent, as to the quality or durability of the system, nor compliance with licensee's
individual specifications and requirements, but solely relates to the system meeting the
requirements of the above named regulatory body in effect as of this date.
!FINAL INSPECTION ON 7/14/06-SYSTEM APPROVED_ SPRAYFIELD NEEDS r0 BE SEEDED/SODDED. KEEP UNDERBRUS0
'CLEARED FRQM SPRAYFIELD IN BACK OP PROPERTY
R-10
env ronmental Health Specialist
04/18/2006 16:10 9798231606 ELEGANT LIVING HM PAGE 02
APR-18-21006 01:17 FROM: T0:8231606 P.3
66,1.0�
MACARTWR SU""'t I NC .
P.O. 80x 002
BRYAN TEXAS 77505
IY797 777-9609
Npa TH
Ir _ .
1"%t6-r
LOT 24.�-
1� 19b66, ' f
1 ,
162.50.! '"•�+• ,�C�` ' GRArF11C btAl.e
60T 44 1�7 ,26 = al a p zo 40 00
IN PeCT
.fir-• -�6 M ►�A'JUQ'D
-
r�- I1 .rII1 I G11 ON M�Rt Fe �
1/R'IR0►� R00! R rldT
. 11 �. III taro V2' * MAVIG
I!I _-� ► ICI or„��
ar,
6LOGK 3 J r.v,e, • rlle4ro 1RI61*C CAXdiT
1 1 LOT Z ' j.C.ilk
P
1.054 AG R (, g LQT
L• 1.0l0 AGM
II �I pulMD HtC141StCr
N t - h li, DUR71M19 rFGI� TI LOLATAT OM
1 �
K �� � O' e00lkRe Dr AG 17Y
LOT ! * 1 Nae - I ee�.tst.lnenecell,cee
4%1
i —Alf
,
j I 1 1
j I
1 1
F _s�R0' P.U.
RAD-455'R rs-?e�R N
I-
1702 JOHN50N CREEK LOOP
?a- R.0m. mw /MT
Lot TWO (2) , SIWX 11mm ( 9) r KUZ'TW CllaFK SLVMVZB=i PHNSO 2, an
the plat � Tf Vp1� 67 ;ge�9 0E is -oaf I�c�or�
Q=ty, 8.
TRANSMISSION VERIFICATION REPORT
TIME 04/10/2006 18:58
NAME COOS DEVELOPMENT SER
FAX 9797643496
TEL 9797643570
SER.# BROE2J341073
DATE,TIME
04/10 18:57
FAX NO./NAME
98215796
DURATION
00:00:38
PAGE(S)
01
RESULT
OK
MODE
STANDARD
ECM
..:......:::::::.
1:icat� on ,
:. in ... ry..:::
p: Applit3lon05w90OPIc
® 90frc1S
� ConUaeroreacrora
Fees
6�1 Oludal amance aw
✓ ifi'"bif f'w—W,
Mlecellaeaous Infc
® Names
® Pbrmlb
® PionlreckinO
l•. �' RBcl3lpte
® pgUereraolapa to
:.� 4hucturoe
® VRIUa1190 C21CU1811
06-1 oa.li
Fmnll ; Narm (Ilow+N,rardlrrst i SSinP4v� • I�'IP
Property lnformAilezl ApplrcauUm rnIII
rnu r.r
addrelr'- 4792 •JmarsOd tSB LOG! AppllCat1ph atatne: lE7esiM TSSUTA
caw,E[& STJJ(pff, �e 7ZEA3 Status Patel .f7Pl204R
tgcarien 'ID; 202.132 110iicat1o11 tMM' T'W POLE.
weer nalr�: art,• CpFB=ToRS LTA �ivatiea "to" lysafRocS
ptstr �, i6aaRn:a4Pa-0020 YeLuatioA: WQ
A 9: R*+1+1* Snveiro IWutb: 6
nQ; WK RON, 1AL �• wmuc'bniidinm .NA
4( cantsaat r R,ea: TLTRW Lrn= HOBS
cuntraCtor awaar: .leaf
Status: ?dim:
CaAtractor Rimmtr—ats .Anc mm4e'r
SAM sbAedl o conrirmtian
.)ram m 'Anlw• Mrt/leS
gowontatandi3W 1Angeoti0na 6Z1Xt
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 17840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00001068 Date 4/10/06
Property Address . . . . . . 4702 JOHNSON CREEK LOOP
Property ID . . . . . . . . . 660050-0203-0020
Application type description TEMP POLE
Subdivision Name . . . . . . WILLIAMS CREEK PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 0
Owner Contractor
------------------------
------------------------
ELEGANT LIVING HOMES
WILLIAM C MORRIS
PO BOX 7063
BRYAN TX 77805
(979) 823-0638
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . GS
Permit Fee . . . . 20.00
Issue Date . . . . 4/10/06 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
-------------------
BUILDING DE
APPLICANT:
PREPARED 8/02/06, 7:54:14 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/01/06
------------------------------------------------------------------------------------------------
ADDRESS . : 4702 JOHNSON CREEK LOOP SUBDIV: WILLIAMS CREEK PH 2
CONTRACTOR ELEGANT LIVING HOMES PHONE (979) 823-0638
OWNER . . PHONE
PARCEL . . 660050-0203-0020
APPL NUMBER: 06-00001029 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/17/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
4/17/06 AP April 17, 2006 8:04:45 AM bkorthauer
04/17/2006 11:13 AM RH PDA
Slab survey on file and slab ground installed.
B115 01 5/18/06 OC BLDG, FRAMING TIME: 17:00
5/18/06 AP May 18, 2006 11:14:05 AM bkorthauer
B130 O1 5/19/06 JGM BLDG, INSULATION TIME: 17:00
5/19/06 AP May 19, 2006 11:03:48 AM kwolfe
May 19, 2006 4:50:49 PM kwolfe
B125 01 8/0 /06 B BLDG, FINAL TIME: 17:00
August 1, 2006 2:19:54 PM kwolfe
L
' ----- ---------- ---------- COMMENTS AND NOTES --------------------------------------
o�'
Date: 8/2/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 1029
Address: 4702 JOHNSON CREEK LOOP
Type
Inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
04/17/2006 11:13 AM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Slab survey on file and slab ground installed.
B130
BLDG, INSULATION
IC
May 19, 2006 4:50:49 PM kwolfe
P125
PLBG, FINAL
IC
July 26, 2006 11:31:58 AM kwolfe
Page 1
In G� TRANSMISSION VERIFICATION REPdRT
i V
TIME 07/26/2006 11:40
NAME
FAX
TEL
SER.# 000L5J596800
DATE,TIME
07/26 11:39
FAX NO./NAME
98215796
DURATION
00: 00: 26
PAGE(S)
01
RESULT
OK
MODE
STANDARD
ECM
Inspecoon Resulits.Entry
- 6JA,- (�;)
H&MIR. ; He.m tNirtlu 1 SURPKW
# skill i I Pirjift
Application number, type:
08 00001 On R�WENTl+AL, I UNIT DETACHED NEW
struabov, Vomit:
000 000 ELEN 00
Inspection tlrpe, sequence:
E150 0001 ELEC, FINAL
Property address:
4702 JOHNSON CREE}f Loop
Request date, time, by.
7C.d8108 17:00 KVV
Inspector ID:
16E �
Results date:
a7rasrzaae
Results status:
E ,
Final Inspection flog:
Y
V. Edit eamments
17, Display Impod*ri psnaitles
Paint value: t
WF0778518 /
001 City of College
Station
PAGE 1
REQ. DATE:
05/24/06 `
05/24/06
10:54:08
LOCATION:
923 CRESTED POINT DR
LOC ID:
203794
REQUESTOR:
STYLECRAFT BUILDERS
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
05/24/06 SCHED
COMPLETION:
05/24/06
********************************************************************************
JOB ORDER RESULT COMVIEBTTS
pt)-lw2'
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
'Z�OLLEGE STATION, TX 778•—,
PHONE: (979f764-3570 FAX: (979)764-3496
--------------------------------------------------- Irl------------------------
Application Number . . . . . 06-00001029 Date 4/10/06
Property Address . . . . . . 4702 JOHNSON CREEK LOOP
Property ID . . . . . . . . . 660050-0203-002,0
R # . . . . . . . . . . . . . R****
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WILLIAMS CREEK PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 235600
Owner Contractor
------------------------ ------------------------
ELEGANT LIVING HOMES
WILLIAM C MORRIS
PO BOX 7063
BRYAN TX 77805
(979) 823-0638
--- Structure Information 000 000 SINGLE FAMILY
Construction Type COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE STUCCO
IMPACT/PRORATA.FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 3476.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 329.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit Fee . . . . 868.00 Plan Check Fee .00
Issue Date . . . . 4/10/06 Valuation . . . . 235600
Expiration Date . . 10/07/06
Qty Unit Charge Per Extension
BASE FEE 460.00
136.00 3.0000 THOU BLDG, VAL 100001-500000 408.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
-----------------------J%--'---/ATIVE:
------------ ----IV -- ---•------------
BUILDING DEPT ,�EPF�ESE •
/J� � r
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77800
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001029
Page 2
Date 4/10/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION. SEPTIC SYSTEMS INSTALLED
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
1. E�:BUILDING DPTE
/APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00001029
Page 3
Date 4/10/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Septic System
------------------------ --------------------- ---- -- -- --�-------
BUILDING DEPT PRE�ENTATI
APPLICANT: ////I,. I //////1 `,
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 778AO
PHONE: (979)764-3570 FAX: (979)764-3496
Page 4
Application Number . . . . . 06-00001029 Date 4/10/06
----------------------------------------------------------------------------
Special Notes and Comments
24" Culvert Required
Minimum finished floor of 250, for sewer only
Narrow wall bracing by prescriptive methods and engineered
panel
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 868.00 868.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 868.00 868.00 .00 .00
BUILDING DEPT/REPMSENTAT
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning & Development Service
WWW.CSTX.GOV
ADDRESS/LOCATION: L
LOT Z/ BLOCK �1_3
BUSINESS/OWNER NAME
D2 Jcbh
For Office Use Only
DATE44 60 TRCC REG
APPI,ICATION #
TEMP POLE #
fa -e. 67-rit.-l-zOv
"SUBDIVISION UV I I I (GtVYI S DI I�'� SEC/PH Z
ea a,l...-I U 1 � dt 4_T P'F�NE: (_Z�-S-Z2D__00?J
CONTRACTOR/HOMEOWNER:rX/VYLQ, PI �'�j23 :� (Of
CONTRACTOR ADDRESS: P• � � -7 06 3 U T)c -7 Z&y S
ELECTRICIAN: ikoyllas CleQl 1 � �- � PLUMBER:
� A _ � 1' � Ll IMtoi (
HVAC: fv l �`�� A' /� Y)�
GOOD CENTS (Residential only):
V
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK:
STRUCTURE USE: K.QS 1d e4nC_-e--,
Pi E
I e- 4z�,P-), , ki
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: yes;,5
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION,.7#�E EABPRJ
a 3 5 �(?C�
VALUATION: $ -'� TOTAL AREA: T C19 HEATED AREA: J 4 7%
(Cost of Labor and Materials)
PUBLIC SEWER
Ell"S'"EPTIC/TREATMENT SYSTEM
❑ SEWER TAP: 0 ocn'eJ
SIZE
WATER TAP:
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
*If proposed work involves new bewA
commercial property, building elevati(
` S�f14�c Plans Examiner
- N 1' Cu I1610f
- S A 1'0'4hary S
NUMBER OF BEDROOMS: _1
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE: 5-HAC1 lsh _f
EXTERIOR WALL TYPE: 'l l 14- /Skf C�cC svt to f
FOUNDATION TYPE: (Doc `e_4e on er`o(_
ROOF TYPE: C" IV) Q 5 41 Uy-,
DOUBLE F__1 TRIPLE
CARPORT
z;iRstruCUUnI T Tacaae nipr ments/re vations to an existing
required.
Official Use Only
Zoning Official
— rw ,.j. rF2-sv.�
ments:,
E or NO
FeP_ CeAIA14.f, 01411-q
uD_,f
I _ L1Y►9�y�(
- 1VAW&aWg11 69A"r4j Aefc94+#vemAwst1 WlCot0S6, 3A"M+, �R ��c• �4na
Energy Code Compliance Information
% Glazing of exterior walls - %, O ✓
Insulation R value of exterior walls i3
Insulation R value of ceiling 1 (flat areas)y D
Insulation R value of. ceiling 2 (vaulted areas/no attic) Lxi
Glazing SHGC
Glazing U-Factor f (0 o /
R value of ductwork & J
A/C SEER Rating
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Nanning & Development Services
PLAN REVIEW/PERMIT NUMBER# 06 _ D,g
DATE: /r Iota
BUILDING ADDRESS: q ?aa To koL
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
14
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning c5 Development Services
11. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA'F
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
I /
1V
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated on plans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
V. Electrical Service Requirements
NAMJ
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N O
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vlll. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
AIA
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
K
Does not block any water course or divert any flow
Elevation certificate if required
A
(*hrq"
CITY OF COLLEGE STATION
Planning d Development Services
Comments:
s
LANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
�- �-`o(
DATE
I
181.4'
4702 Johnson Creek Loop
Lot 2, Block 3, Phase 2
Williams Creek Subdivision
Scale 1'=30'
y?o2
Homes;
130.59'
15.18'
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheck So$ware Version 3.6 Release 2
Data filename: C:\Program Files\Check\REScheck\4702 Johnson Creek.rck
PROJECT TITLE: 4702 Johnson Creek Ct., College Station, Texas 77845
CITY: Bryan (Brazos)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.27
DATE: 03/22/06
DATE OF PLANS: 12-20-05
PROJECT DESCRIPTION:
4702 Johnson Creek Ct.
College Station, Texas 77845
Lot 2, Block 1, Williams Creek, Phase 1
i DESIGNER/CONTRACTOR:
ELH-Elegant Living Homes, Inc.
P. O. Box 7063
Bryan, Texas 77845
979-823-0638
PROJECT NOTES:
Please call when permit is ready:
Bill 979-229-2045
Cindy 979-777-0703
Thanks!
COMPLIANCE: Passes
Maximum UA = 875
Your Home UA = 792
9.5% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-ValueU Factor -A
Ceiling 1: Flat Ceiling or Scissor Truss 3476 0.0 30.0 108
Wall 1: Wood Frame, 16" o.c.
3220
Window: 3070 Low E: Metal Frame, Double Pane with Low-E
126
SHGC: 0.36
Window: 3016 Low E Tr:
Metal Frame with Thennal Break, Double Pane
18
SHGC: 0.36
Window: 4070 Low E:
Metal Frame with Thermal Break, Double Pane
84
SHGC: 0.36
Window: 3010 Low E: Metal Frame, Double Pane with Low-E
6
SHGC: 0.36
Window: 3660 Low E: Metal Frame, Double Pane with Low-E
420
SHGC: 0.36
Window: 3620 Low E:
Metal Frame with Thermal Break, Double Pane with Low-E
7
SHGC: 0.36
Window: 3016 Low E Tr:
Metal Frame with Thermal Break, Double Pane
9
SHGC: 0.36
Window: 3060 Low E:
Metal Frame with Thermal Break, Double Pane with Low-E
36
SHGC: 0.36
Window: 3080 Low E: Metal Frame, Double Pane with Low-E
48
SHGC: 0.36
Window: 1616 Low E:
Metal Frame with Thermal Break, Double Pane with Low-E
6
SHGC: 0.36
Window: 2040 Low E: Metal Frame, Double Pane with Low-E
8
SHGC: 0.36
Window: 4040 Low E: Metal Frame, Double Pane with Low-E
16
SHGC: 0.36
6080 Door: Glass
48
SHGC: 0.30
2880 Door-w/mini: Glass
21
SHGC: 0.30
2868 Door: Solid
18
Heat Pump 1: Air Source, 6.8 HSPF, 13 SEER
Air Conditioner 1: Electric Central Air, 13 SEER
13.0 0.0
193
0.600 76
0.600 11
0.600 50
0.600 4
0.600 252
0.600 4
0.600 5
0.600 22
0.600 29
0.600 4
0.600 5
0.600 10
0.130 6
0.130 3
0.580 10
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Design Date C73
REScheck Inspection Checklist
2000 IECC
REScheck Solware Version 3.6 Release 2
DATE: 03/22/06
PROJECT TITLE: 4702 Johnson Creek Ct., College Station, Texas 77845
Bldg.
Dept.
Use
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1. Window: 3070 Low E: Metal Frame, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 3070 Low E Window
2. Window: 3016 Low E Tr: Metal Frame with Thermal Break, Double Pane,
U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 3016 Low E Transom
3. Window: 4070 Low E: Metal Frame with Thermal Break, Double Pane, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 4070 Low E window
4. Window: 3010 Low E: Metal Frame, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-fcctors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 3010 Low E Window
5. Window: 3660 Low E: Metal Frame, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ) Yes [ ] No
Comments: 3660 Low E Window
6. Window: 3620 Low E: Metal Frame with Thermal Break, Double Pane with Low-E,
U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ J No
Comments: 3620 Low E Transom
7. Window: 3016 Low E Tr: Metal Frame with Thermal Break, Double Pane,
U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
8. Window: 3060 Low E: Metal Frame with Thermal Break, Double Pane with Low-E,
U-fictor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 3060 Low E window
9. Window: 3080 Low E: Metal Frame, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 3080 Low E Window
10. Window: 1616 Low E: Metal Frame with Thermal Break, Double Pane with Low-E,
U-fictor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ J Yes [ ] No
Comments: 1616 Low E window
11. Window: 2040 Low E: Metal Frame, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 2040 Low E Window
12. Window: 4040 Low E: Metal Frame, Double Pane with Low-E, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: 4040 Low E Window
Doors:
1. 6080 Door: Glass, U-factor: 0.130
Comments: 6080 Door
2. 2880 Door-w/mini: Glass, U-factor: 0.130
Comments: 2880 Door w/ mini blind
3. 2868 Door: Solid, U-factor: 0.580
Comments: 2868 Sold 6 panel
Heating and Cooling Equipment:
1. Heat Pump 1: Air Source, 6.8 HSPF, 13 SEER or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 13 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
y � .
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required iar each separate HVAC system. A manual or automatic means to
partially restrict or shut of the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe rises must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 °F must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature (F) Up to 1„ Un to 1.25" 1.5" to 2.0" Over 2„
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" " t "
Heating Systems
Low Pressure/Temperature
Low Temperature
Steam Condensate (for feed water)
Cooling Systems
Chilled Water, Refrigerant,
and Brine
201-250
1.0
1.5
1.5
2.0
120-200
0.5
1.0
1.0
1.5
Any
1.0
1.0
1.5
2.0
40-55
0.5
0.5
0.75
1.0
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)