PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW/PERMIT NUMBER# � _ q9
DATE: q /,r/oG
BUILDING ADDRESS: jyg
I. Foundation Requirements
NA/ K
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings (30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N O
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
11. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NIV71
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
NAQV
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated onplans)
K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NAXW
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NAJOW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/ K
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
NAl
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
K
Does not block any water course or divert any flow
Elevation certificate if required
AA
/1��T
CITY OF COLLEGE STATION
Planning dd Development Services
Comments:
-A&4-L-
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
�/-a(to
DATE
4
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheck So$ware Version 3.6 Release la
Data filename: C:\Program Files\Check\REScheck\Job 122.rck
PROJECT TITLE: Job 123
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.11
DATE: 04/03/06
DATE OF PLANS: 4/3/2006
PROJECT DESCRIPTION:
T oedter Residence
DESIGNER/CONTRACTOR:
Clay Kolby Homebuilding
COMPLIANCE: Passes
Maximum UA = 876
Your Home UA = 557
36.4% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Gross Glazing
Area or Cavity Cont. or Door
Perim R-Value R-ValueU Factor jlA
Ceiling 1: Flat Ceiling or Scissor Truss
2288
0.0 30.0 71
Wall 1: Wood Frame, 16" o.c.
3342
13.0 0.0 243
Window 1: Metal Frame:Double Pane with Low-E
331
0.640 212
SHGC: 0.36
Door 1: Solid
28
0.640 18
Door 2: Glass
20
0.640 13
SHGC: 0.36
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 14 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in REScheck Version 3.6 Release la (f)rmerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer LS Date L� 3I d(P
REScheck Inspection Checklist
2000 IECC
RES check Sofware Version 3.6 Release la
DATE: 04/03/06
PROJECT TITLE: Job 123
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor. 0.640
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-fictor: 0.640
Comments:
[ ] 2. Door 2: Glass, U-factor. 0.640
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
[ ] 2. Air Conditioner 1: Electric Central Air, 14 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals fDr all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled $uids below 55 T must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature ( F) jjn to 1" LID to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness
in Inches by Pi en
Sizes
Piping System Types
RanF
2" Runouts
V and Less
1.25" to 2"
2 " to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for £ed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
le
I I
I I
I I
I I
I I
I 1
I I
I r----------------------
1 1
I I O' Setback I I
I i I I
I I I i
I I I
I I I I
i I
i I I I
I I I I
I
I I I I
I I I I
I I ,----------
Oct
I I
I I I I I I
I I I ! I I
I it I I 1
I II it I
back I I I
I I �,5 Setback I
II I
150.671 11 I 129,81'
I I� jl I
I II II I
II II I
I II II I
I II II I
II _
I • ° d
I � v •• v � ° ,e I I
i Lot 6 Block I I P ° d: :
I
I Sec, 5 Ph. 2 f:...t. • 1
Castegate I - I I
! .°
L— — — — — — — — — — — — • ._�
66,28' AY97 A)ew G►^R
PREPARED 8/04/06, 11:59:26 INSPECTION TICKET PAGE 22
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/04/06
------------------------------------------------------------------------------------------------
ADDRESS . : 2487 NEWARK CIR SUBDIV: CASTLEGATE PH 5 SEC 2
CONTRACTOR CLAY KOLBY HOMEBUILDERS PHONE (979) 777-9840
OWNER . . PHONE
PARCEL . . 184200-2501-0060
APPL NUMBER: 06-00000999 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/13/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
4/13/06 AP April 13, 2006 8:17:42 AM kwolfe
friday PM
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 5/26/06 OC BLDG, FRAMING TIME: 17:00
5/26/06 AP May 26, 2006 10:22:02 AM glsouth
B130 01 6/05/06 BH BLDG, INSULATION TIME: 17:00
6/05/06 AP June 6, 2006 9:22:47 AM kwolfe
_B125 01 8/ '4/0 BI BLDG, FINAL TIME: 17:00
August 4, 2006 9:28:50 AM kwolfe
late_PM
------------------------I------ CONTINUED ONTO NEXT PAGE -----------------------------------
' �CI
564 v G lu'
�7 5
Date: 8/4/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 999
Address: 2487 NEWARK CIR
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
June 6, 2006 9:22:47 AM kwolfe
Ell
ELEC, ROUGH IN
IC
May 19, 2006 4:51:10 PM kwolfe
Ell
ELEC, ROUGH IN
IC
need to block homerun
E150
ELEC, FINAL
IC
08/04/2006 07:58 AM JGM PDA
E150
ELEC, FINAL
IC
not hot
M100
MECH, ROUGH IN
IC
May 19, 2006 4:52:08 PM kwolfe
M100
MECH, ROUGH IN
IC
need walkway to upper unit adn 30" platform in front of
M100
MECH, ROUGH IN
IC
lower unit
Page 1
Kim Wolfe Insulation request inspection result, 2487 Newark #06 999 Page 1
From:
Brian Henry
To:
Southerland, Gina
Date:
6/5/2006 4:40:44 PM
Subject:
Insulation request inspection result, 2487 Newark, #06-999
Print for file
Inspected insulation, 2487 Newark, #06-999, Clay Kolby Homes, 6-5-06
Inspection result: Inspected OK for Code Only
Notes:
Replace insulation batts removed by alarm contractor.
CC: Korthauer, Brittany; Wolfe, Kim
WF0757575 / 001 City of College Station PAGE 1
j
REQ. DATE: 04/04/06 04/04/06 12:48:31
LOCATION: 2487 NEWARK CIR LOC ID: 204028
REQUESTOR: CLAY KOLBY HOMEBUILDING ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/04/06 SCHED COMPLETION: 04/04/06
********************************************************************************
JOB ORDER RESULT COMYIENTS
BUILDING PERMIT
CITY OF COLLEGE STATION
110.1 TEXAS AVE
COLLEGE STATIO1q, TX 77840
PHONE: (979) 764-3570,. FAX: (979) 764-3496
------------------------------------ i---------------------------------------
Application Number . . . . . 06-00000999 Date 4/04/06
Property Address . . . . . . 2487 NEWARK CIR
Property ID: 184200-2501-0060
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 180000
Owner
Contractor
------------------------
------------------------
CLAY KOLBY HOMEBUILDERS
P O BOX 8
NAVASOTA
TX 77868
(979) 777-9840
--- Structure Information
000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2288.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
BK
Permit Fee . . . .
700.00 Plan Check Fee
.00
Issue Date . . . .
4/04/06 Valuation . .
. . 180000
Expiration Date . .
10/01/06
Qty Unit Charge Per Extension
BASE FEE 460.00
80.00 3.0000 THOU BLDG, VAL 100001-500000 240.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
---------------------------------------------- ----- --- --'------------
BUILDING DEPT REPRESENTATIVE: 01
APPLICANT: 1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000999
Page 2
Date 4/04/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
------------------- - - - - -- ----- - -- - :------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000999
Page 3
Date 4/04/06
Special Notes and Comments
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
-
--------------- ----- -----------------------
BUILDING DEPT REPREESEN\TATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . .
06-00000999
Date
4/04/06
----------------------------------------------------------------------------
Special Notes and Comments
RANGE/DRYER DUCT MUST COMPLY
WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical)
WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS.
CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING
ANY WORK
Narrow wall bracing Fully Sheathed
with Simpson
Panel to
right of back door area.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 700.00
700.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1450.00
1450.00
.00
.00
-
I* APPLICATION FOR BUILDING PERMIT
LaCITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US /
ADDRESS/LOCATION: 7NI-7 EWA'RK Cte
LOT U BLOCK I f SUBDIVISION
BUSINESS/OWNER NAME:
C�Irr'Ecwar=
DATE: 64
APPLICATION # OL
TEMP POLE #
I�v�L
PHONE:
SEC/PH E �L-v
CONTRACTOR/HOMEOWNER: bA-1 140u4 40IME&4.006 PHONE: 1-1-7—`IS10
CONTRACTOR ADDRESS: "1-;>.0. 3 c X % M AV Aso 1 � k
ELECTRICIAN: Gy-W
HVAC: SIiEbE2i
PLUMBER: 5*B J r3
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK: ((z O.TEiW t*0M&F_
STRUCTURE USE: �bM.SarrA'e- '(LV51113Errt'tE_
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (T ) PROJECT REGISTRATION# EABPRJ
VALUATION: $ /$U 00 o TOTAL AREA: 31 �t HEATED AREA: 221'6
(Cost of Labor and Materials)
L 5 PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
54, SEWER TAP: zq0
SIZE
WATER TAP: Vil1 f
SIZE
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SINGLE ED
ATTACHED
SIGNATURE OF APPLICANT:
�;l 1p Plans Examiner
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
DETACHED a
Official Use Only
3.57
ff-,w-5h`FfT71p�K
5-rrsw� l � 21C K
5t*e CA1i &04v4.-
2�0 -((Z C 0.►P
TRIPLE ED
CARPORT
Zoning Official
111 to[ sf4V'4 /)Jw/e
y._
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
I ✓
13
3v /1"',
r— /