Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2006-00991, 06-992
Ott -qaa (Akol6p) �Pendaflelif %Esselte R 7521/3 10% P4 PREPARED 8/21/06, 12:02:27 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/21/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 1004 CRESTED POINT DR SUBDIV: WESTFIELD VILLAGE PH 4 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0410-0080 APPL NUMBER: 06-00000991 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/27/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 4/27/06 AP April 27, 2006 10:55:40 AM bkorthauer 04/27/2006 03:05 PM RH PDA Strings up, slab ground installed. B115 01 6/22/06 OC BLDG, FRAMING TIME: 17:00 6/22/06 AP June 20, 2006 11:30:59 AM glsouth B130 01 6/26/06 JGM BLDG, INSULATION TIME: 17:00 6/26/06 AP June 26, 2006 10:03:18 AM bkorthauer B132,01 7/03/06 RH BLDG, SHEETROCK FASTENER TIME: 17:00 O .' 7/03/06 AP July 3, 2006 8:07:04 AM kwolfe B125 Ol 8/21/06 BI BLDG, FINAL TIME: 17:00 ec_ AP August 21, 2006 11:10:44 AM glsouth ------------------------------�---(------- COMMENTS AND NOTES------- I�Ov�l� Cr rL uY- fN U {� N WF0766720 / 001 City of College -Station PAGE 1 a REQ. DATE: 05/04/06 05/04/06 8:10:47 LOCATION: 1004 CRESTED POINT DR LOC ID: 203856 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/04/06 SCHED COMPLETION: 05/04/06 ******************************************************************************** JOB ORDER RESULT COY91=S WF0761374 / 001 City of Station PAGE 1 REQ. DATE: 04/19/06 04/19/06 14:09:34 LOCATION: 1004 CRESTED POINT DR LOC ID: 203856 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/19/06 SCHED COMPLETION: 04/19/06 ******************************************************************************** JOB ORDER RESULT COMMENTS BUILDING PERMIT CITY Ox.-,CQL'LEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000991 Date 4/19/06 Property Address . . . . . . 1004 CRESTED POINT DR Property ID: 005401-0410-0080 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 78210 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 1.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1185.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . BUILDING PERMIT Additional desc KW Permit Fee . . . . 376.00 Plan Check Fee .00 Issue Date . . . . 4/19/06 Valuation . . . . 78210 Expiration Date . . 10/16/06 Qty Unit Charge Per Extension BASE FEE 260.00 29.00 4.0000 THOU BLDG, VAL 50001-100000 116.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-FRAMED SIZE 22" -------------------------------------------- BUILDING DEPT REPRESENTATIVE: ----- - - ------------ APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000991 Page 2 Date 4/19/06 Special Notes and Comments X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK I DONE IN ORDER TO - --------------- ----- ---------------------- ----- -- ---• - ------------ BUILDING DEPT REPRESENTATIVE: • APPLICANT` BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00000991 Date 4/19/06 ---------------------------------------------------------------------------- Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 1 " ABOVE THE FLOOR IN ------------------------ ----- -�-------------- BUILDING DEPT REPRESENTATIVE: APPLICANT:- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000991 Date 4/19/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Narrow wall Bracing by Engineered Methods ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total ---------- 376.00 376.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1126.00 1126.00 .00 .00 - APPLICANT7— TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000992 Date 4/19/06 Property Address . . . . . . 1004 CRESTED POINT DR Property ID: 005401-0410-0080 R #. Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KE Permit Fee . . . . 20.00 Issue Date . . . . 4/19/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------- ----x- APPLICANT:—<�- l` Far O/fice Use Only APPLICATION FOR BUILDING PERMIT DATE `�1 TRCC REG CITY OF COLLEGE STATION t* ff 1101 TEXAS AVENUE APPLICATION # ((pp G��/j COLLEGE STATION, TX 77840 TEMP POLE # ©u — 1 `� CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning & Deodopment Semites WWW.CSTX.GOV / ADDRESS/LOCATION: C�2Es POI N r LOT BLOCK 10 -(SUBDIVISION SEC/PH �/ BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION . MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �A D A — TEXAS ACCESSIBILITY STANDARS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ '7421 O TOTAL AREA: I Lo2—I HEATED AREA: ( 85 (Cost of Labor and Materials) F- PUBLIC SEWER NUMBER OF BEDROOMS: 3 3� SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 2 �X SEWER TAP: 4e O SIZE QX WATER TAP: 3/4" SIZE OTHER TAP: SIZE 4 S TEMP POLE 1 GARAGE TYPE: SINGLE El ATTACHED INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab On Grade ROOF TYPE: Composition DOUBLE [::] TRIPLE DETACHED F__] CARPORT SIGNATURE OF APPLICANT: For St lecraft *If proposed work involves new commercial constructioYi or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Plans Examiner 7A7i2. p tV11l i F'-k' e &'G Zoning Official ents: (aESA NO Q4 - Energy Code Compliance Information l % Glazing of exterior walls q % Insulation R value of exterior walls R13 ,--' Insulation R value of ceiling 1 (flat areas) R30.1� Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40� Glazing U-Factor .65 R value of ductwork R6 A/C SEER Rating 13 --" PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services PLAN REVIEW/PERMIT NUMBER# 06_ DATE: BUILDING ADDRESS: od F,61-m+Q I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. :f (*hrq" CITY OF COLLEGE STATION Planning 6 Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes +A' Ill. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches N 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 11 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread I, 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway j 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) A/ K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d- Development Services Ko V. Electrical Service Requirements N K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements NAM A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values; etc.) Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Densityrequirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed AM — Street Ordinance Requirements NA/qn Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required 4 CITY OF COLLEGE STATION Planning d Development Services Comments: 464k PL N E MINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS y-- 3 -- D 4 DATE J Permit Number REScheck Compliance Certificate Checked By/Date 2003 IECC REScheck Software Version 3.6 Release 2 Data filename: S:\ACAD\Archived\Old REScheck\1185B 1004 Crested Point.rck PROJECT TITLE: Plan # 1185B-WV CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.11 DATE: 03/30/06 DATE OF PLANS: 03-30-2006 PROJECT DESCRIPTION: Spec 1004 Crested Point College Station, Texas DES IGNER/CONTRACTOR: Stylecrail Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 (::COMPLIANCE:"P sasse Maximum UA = 7485 Your Home UA = 386 20.4% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated Gross Glazing Area or Cavity Cont. or Door Perimeter R Value R Valt e U-Factor 1� 999 30.0 0.0 35 186 19.0 0.0 10 1192 13.0 0.0 84 112 0.670 75 38 0.500 19 18 0.440 8 149 0.0 155 Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer �fna`-i� Date` 20—©(4P V Y RES check Inspection Checklist 2003 IECC REScheck Solfware Version 3.6 Release 2 DATE: 03/30/06 PROJECT TITLE: Plan # 1185B-WV Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor. 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor. 0.500 Comments: [ ] 2. Door 2: Glass, U-fctor. 0.440 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number [ ] 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type 1C rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: [ ] Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturers installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manuficturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the building must be insulated to R11. Supply ducts in unconditioned spaces must be insulated to R-6. Return ducts in unconditioned spaces (except basements) must be insulated to R-2. Where exterior walls are used as plenums, the wall must be insulated to R-8. Insulation is not required on return ducts in basements. Duct Construction: Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. s Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pi ep Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature (Fl Up to 1" Up to 1.25" 1.5" to 2.0" Over 2„ 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pining System Types Range ! F1 2" Runouts 1" and Less 1.25" to 2"2.5 , to 4„ Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (fDr Eed water) Cooling Systems Chilled Water, Refrigerant, and Brine 201-250 1.0 1.5 1.5 2.0 106-200 0.5 1.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Assembly Type MMIMIMMOMM' Comments/ Description ©� -,., - .. off■ . , � • „ • „ ® , . , � Window Area Total: 111.66 03/30/06 11:39:38 1 /1 Area Calculator: Assembly Type' Description Opaque door solid masonite Door Area Total: 55.56 03/30/06 11:39:38 1 /1 Area Calculator: Assembly Type Comments/Description Flat Ceiling or Scissor Truss Ceiling Area Total: 1185.00 03/30/06 11:39:38 1 /1 Area Calculator: I� Comments/Description ®■�■�� Exterior Wall Area Total: 1192.00 03/30/06 11:39:38 1 /1 Area Calculator: Assembly Type Comments/Description- Unheated ..■�■ Floor Area Total: 0.00 03/30/06 11:39:38 1 /1