HomeMy WebLinkAboutRES2006-00988, 06-989WF0757710 /
001 City of College
Station
PAGE 1
REQ. DATE:
04/04/06
04/04/06
16:53:32
LOCATION:
930 CRESTED POINT DR
LOC ID:
203846
REQUESTOR:
STYLECRAFT BUILDERS
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
SWR 4" WTR 3/411
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
04/04/06 SCHED
COMPLETION:
04/04/06
********************************************************************************
JOB ORDER RESULT COW4ENrS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
Owner . . . . . . . . .
Contractor . . . .
12/07/06
005401-0410-0130
930 CRESTED POINT DR
COLLEGE STATION TX 77845
WESTFIELD VILLAGE PH 4
WESTFIELD VILLAGE PH 4
BLOCK 10 LOT 13
PLANNED DEVL HOUSING
STYLECRAFT BUILDERS
979 690-1222
Application number 06-00000988 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . . i
Approved
IV• .
Bui ing Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
Nicole _. Cochran - Re Calling for CO @ 903 Crested Point Dr
.w____ . _v_,...,. u . ,..„ , ,. ...... _...... 1.
From: Paul Schoenfeld
To: Benjamin McCarty; Chris Haver; Gina Southerla
Date: 12/7/2006 9:47 am
Subject: Re: Calling for CO @ 9�- Crested Point Dr
All is good.
Paul Schoenfeld
>>> Nicole Cochran 12/6/2006 12:29 PM >>>
Are there any issues?
BP# 06-988
Merry Christmas!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.gov
PREPARED
11/30/06,
12:00:32
INSPECTION TICKET
PAGE 1
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 11/30/06
------------------------------------------------------------------------------------------------
ADDRESS
. : 930 CRESTED POINT DR SUBDIV: WESTFIELD VILLAGE
PH 4
CONTRACTOR
STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER .
.
PHONE
PARCEL .
. 005401-0410-0130
APPL NUMBER: 06-00000988
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING
PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/18/06
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
4/18/06
AP
April 18, 2006 10:06:56 AM kwolfe
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/13/06
RH
BLDG, FRAMING TIME: 17:00
6/13/06
AE
June 12, 2006 4:11:32 PM glsouth
06/13/2006 10:50 AM RH PDA
Need blocking for coffered ceilings in dining,
master
bedroom and bath.
B130 01
6/15/06
RH
BLDG, INSULATION TIME: 17:00
6/15/06
AP
June 14, 2006 3:56:02 PM bkorthauer
B132 01
6/16/06
OC
BLDG, SHEETROCK FASTENER TIME: 17:00
6/16/06
AP
June 16, 2006 10:19:49 AM glsouth
B125 01
11 30 06
BI
BLDG, FINAL TIME: 17:00
(J 06 O(o
November 30, 2006 9:01:57 AM glsouth
--------------------------------------
COMMENTS AND NOTES -------------------------------
-- �
G f �` • c�'^ r S ins i� l fec�
Date: 12/6/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 988
Address: 930 CRESTED POINT DR
Insp.
inspection Type Code
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/13/2006 10:50 AM RH PDA
B115
BLDG, FRAMING
IC
Need blocking for coffered ceilings in dining, master
B115
BLDG, FRAMING
IC
bedroom and bath.
M110
MECH, FINAL
IC
09/12/2006 03:09 PM JGM PDA
M110
MECH, FINAL
IC
need continuous walkway, need to attach 90 on flue pipe
Page 1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, T3' 77840
PHONE: (979)764-3570 FAX:- (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000988 Date 4/04/06
Property Address . . . . . . 930 CRESTED POINT DR
Property ID . . 005401-0410-0130
R# . . . . . . . . . . . . .
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 81312
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
SIDING
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1232.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
388.00 Plan Check Fee
.00
Issue Date . . . .
4/04/06 Valuation . .
. . 81312
Expiration Date . .
10/01/06
Qty Unit Charge Per Extension
BASE FEE 260.00
32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-FRAMED SIZE 22"
-------------------------------------------- ----- --- -- ---.�-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: _X
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE ,
COLLEGE STATION, 'TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00000988 Date 4/04/06
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM -FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
.)f -------------------------
-
- ----- ----------------
BUILDING DEPT REPRESENTATIVE::
APPLICANT: L41 I
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE ,
COLLEGE STATION,'TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000988
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
Page 3
Date 4/04/06
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
-- -
BUILDING DEPT REPRESENTATIVE: 10-
APPLICANT: J14
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,'TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000988
Date 4/04/06
----------------------------------------------------------------------------
Special Notes and
Comments
PRIVATE GARAGES
Narrow wall bracing
by Engineered
Methods
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
388.00
388.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1138.00
1138.00
.00
.00
-
---------- --- ----------------------
------------ ---
BUILDING DEPT REPRESENTATIVE-: ft_ A_ /
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, 'TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000989 Date 4/04/06
Property Address . . . . . . 930 CRESTED POINT DR
Property ID . . 005401-0410-0130
R# . . . . . . . . . . . . .
Application type description TEMP POLE
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/04/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
---------------------------
Fee summary
------------------------------------------------
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------
------------------ -----
BUILDING DEPT REPRESENTATIVE-: -----
APPLICANT:
-- x - -----------
Fa O/fic Use Only
(*Or""
CITY OF COLLEGE STATION
Planning d-Da�elopment Services
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRESS/LOCATION:
LOT 13 v BLOCK I
DATE: L)l '>I WQ 4 ,T, RCC I
APPLICATION # OLK C
TEMP POLE # CJ
INESTR ELV') V ILLAC-g E�SEC/PH
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Sinale Familv Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ S1312 ,/ TOTAL AREA: HEATED AREA: IZ32
(Cost of Labor and Materials)
FX PUBLIC SEWER
3
SEPTIC/TREATMENT SYSTEM
�X SEWER TAP: 4"
SIZE
QX WATER TAP: %"
SIZE
/ OTHER TAP:
TEMP POLE
3 GARAGE TYPE:
�O
1
s¢E
SINGLE
ATTACHED X�
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE
DOUBLE
DETACHED 71
2
Sheet Rock
Siding and/or Masonry
Slab on Grade
Composition
TRIPLE El
CARPORT
SIGNATURE OF APPLICANT: For Stylecraft
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
. „ / � � Co ments:
76orNO
,W
Plans Examiner Zoning Official
GA c M1114
Yehyl; d 40f'ct'j, rizvfe,.,w
Energy Code Compliance Information
% Glazing of exterior walls
10 %✓
Insulation
R value of exterior walls
R13.X
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling-2-(vaulted-areas/no attic)
R19,-"'
Glazing SHGC
.40
Glazing U-Factor
.65�
/
R value of ductwork
R6
A/C SEER Rating
13 �—
U
CITY OF COLLEGE STATION
Planning er Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# (0 _ q
DATE: q / 3 / 01�
BUILDING ADDRESS: q30 a
o; AA
I. Foundation Requirements
N
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30")
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
M&10K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
(*hrq"
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NAJOW
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N AIW
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow,
Elevation certificate if required
(*hrq"
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
LANS EXAMINER DATE
0
Permit Number
RFScheck Compliance Certificate Checked By/Date
2003 IECC
REScheck Software Version 3.6 Release 2
Data filename: S:\ACAD\Archived\Old REScheck\1232B 930 Crested Point.rck
PROJECT TITLE: Plan # 1232B
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.11
DATE: 03/30/06
DATE OF PLANS: 03-30-06
PROJECT DESCRIPTION:
SPEC
930 Crested Point
College Station, Texas
DES IGNER/CONTRACTOR:
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
[COMPLIANCE:.Passes�
Maximum UA = 538
Your Home UA = 433
19.5% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-V
U-Factor
i A
Ceiling 1: Flat Ceiling or Scissor Truss
900
30.0
0.0
32
Ceiling 2: Cathedral Ceiling (no attic)
332
19.0
0.0
17
Wall 1: Wood Frame, 16" o.c.
1283
13.0
0.0
90
Window 1: Metal Frame, Double Pane with Low-E
127
0.650
83
SHGC: 0.40
Door 1: Solid
38
0.500
19
Door 2: Glass
18
0.440
8
SHGC: 0.40
Floor 3: Slab -On -Grade: Unheated
177
0.0
184
Insulation depth: 0.0'
Air Conditioner 2: Electric Central Air, 12 SEER
Furnace 2: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Date 3 - 44 D-OG-)
RFScheck Inspection Checklist
2003 IWC
REScheck Soflware Version 3.6 Release 2
DATE: 03/30/06
PROJECT TITLE: Plan # 1232B
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor. 0.650
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.500
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.440
Comments:
Floors:
[ ] 1. Floor 3: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher
Make and Model Number
[ ] 2. Furnace 2: Forced Hot Air, 80 AFUE or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat. Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type 1C rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Skylights:
Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
Return ducts in unconditioned attics or outside the building must be insulated to R4.
Supply ducts in unconditioned spaces must be insulated to R-6.
Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
Where exterior walls are used as plenums, the wall must be insulated to R-8.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
ofthe heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness
in Inches by Pipe
Sizes
Heated Water
Mon -Circulating Runouts
Circulating Mains
and Runouts
Temperature (Fl
14P to V Un to 1.25"
1.5" to 2.0"
Over 2„
170-180
0.5 1.0
1.5
2.0
140-169
0.5 0.5
1.0
1.5
100-139
0.5 0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness
in hiches by Pipe Sizes
Piping System Types
Ranee ( Fl
2" Runouts 1" and
Less 1.25" to 2"2.5 , to 4„
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for iced water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Area Calculator:
Description
ME
-me
Window Area Total: 126.65
03/30/06 10:15:39 1 /1
Area Calculator:
Description
M�RNTMI
MR.
Door Area Total: 55.56
03/30/06 10:15:39 1 /1
Area Calculator:
Assembly Type
Comments/Description
03/30/06 10:15:40
Ceiling Area Total: 1232.00
1/1
Area Calculator:
Assembly
Comments/Description
Exterior Wall Area Total: 1282.67
03/30/06 10:15:40 1 /1
Area Calculator:
Assembly Type
Comments/Description
Floor Area Total: 0.00
03/30/06 10:15:40 1 /1