Loading...
HomeMy WebLinkAboutRES2006-00982b '. q tea 3Pendaffor aEsselte Amk R 7521/3 100/OP4 Nicole Cochran - Re Calling for CO @ 4001 Reatta Lane Page 1 From: Joe Garcia To: Benjamin McCarty; Chris Haver; Gina Southerla Date: 11/14/2006 2:25:27 pm Subject: Re: Calling for CO @ 4001 Reatta Lane THIS ONE IS OK. JMG >>> Nicole Cochran 11/14/06 8:07 AM >>> Are there any issues? BP# 06-982 Thanks! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.csb(.gov WF0758756 / 001 City of Collecj�tion PAGE 1 REQ. DATE: 04/07/06°' 04/07/06 14:39:36 LOCATION: 4001 REATTA LN LOC ID: 200910 REQUESTOR: ED FROEHLING BUILDER ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/07/06 SCHED COMPLETION: 04/07/06 ******************************************************************************** JOB ORDER RESULT COMVIENTS City of College Station 1101"TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . 11/14/06 537300-0104-0180 4001 REATTA LN COLLEGE STATION TX 77845 REATTA MEADOWS SEC 1 PH 1 REATTA MEADOWS, BLOCK 4, LOT 1 8 SINGLE FAMILY RESIDENTIAL BARRON ROAD MEADOWS L.P. ED FROEHLING BUILDERS 979 776-8266 06-00000982 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX A, - Bu()ding GiTiZ�ial" " VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 11/14/06, 8:02:30 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/13/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 4001 REATTA LN SUBDIV: REATTA MEADOWS SEC 1 PH 1 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER BARRON ROAD MEADOWS L.P. PHONE PARCEL 537300-0104-0180 APPL NUMBER: 06-00000982 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/25/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/25/06 AP May 25, 2006 10:59:44 AM kwolfe Strings On Setbacks O.K. Slab Ground Installed B115 01 7/13/06 JGM BLDG, FRAMING TIME: 17:00 7/13/06 AE July 13, 2006 9:38:40 AM bkorthauer Sheetrock Fireplace Chase, Firestopping B130 01 7/28/06 OC BLDG, INSULATION TIME: 17:00 7/28/06 AP July 27, 2006 4:36:50 PM glsouth B125 01 11/13/06 �BII BLDG, FINAL TIME: 17:00 14- ryx November 13, 2006 2:27:45 PM glsouth ---------------------------------------- COMMENTS AND NOTES ----------------- b� O-VAA �'[ M Date: 11/14/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 982 Address: 4001 REATTA LN Insp. inspection Type Code Status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC Sheetrock Fireplace Chase, Firestopping P125 PLBG, FINAL IC Pressure Test Not Holding Page 1 BUILDING PERMIT CI PY: OFi COLLEGE STATION 1101TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . .'; 06-00000982 Date 4/07/06 Property Address . . . . . . 4001 REATTA LN Property ID: 537300-0104-0180 R #: R300715 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . REATTA MEADOWS SEC 1 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 138138 Owner Contractor ------------------------ BARRON ROAD MEADOWS ------------------------ L.P. ED FROEHLING BUILDERS PO BOX 277 ED FROEHLING NORMANGEE TX 778710277 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2093.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 577.00 Plan Check Fee .00 Issue Date . . . . 4/07/06 Valuation . . . . 138138 Expiration Date . . 10/04/06 Qty Unit Charge Per Extension BASE FEE 460.00 39.00 3.0000 THOU BLDG, VAL 100001-500000 117.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) BUILDING DEPT RREPRESENTATIVE: APPLICANT: BUILDING PERMIT CI';Y OF; COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00000982 Date 4/07/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE -------------------------------------------- - ------ ------ ---- - -------- BUILDING DEPT REPRESENTATI�VyE}:� 110- APPLICANT: W,,9v n/V1 BUILDING PERMIT CITY OF't COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00000982 Date 4/07/06 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN - --------- ------ ----- ------------------------ ------ --- - -- -:---------- BUILDING DEPT REPRESENTATIVE: : APPLICANT: � q'A /�1 M BUILDING PERMIT CITY OF.COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000982 Date 4/07/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Narrow wall bracing Fully Sheathed ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 577.00 577.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1327.00 1327.00 .00 .00 - ( CITY OF COLLEGE STATION Planning 6, Development Simko_ APPLICATION FdR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV For Office Use ly DATE:L5 'L-�*14 PEG APPLICATION # �� TEMP POLE # ADDRESS/L ATION: �tVV t t4cs l TIQ U LOT BLOCK 1t' y SUBDIVISION E+Q►T��' FAA M C1/s✓SEC/PH BUSINESS/OWNER NAME: PHONE: 5m % - PvIpeSE CONTRACTOR/HOMEOWNER: Ed FF;Z0MALI1,4Ca BUIL XV, PHONE: "770'$26(a CONTRACTOR ADDRESS: 9_4>6D cs-rx _n82, ELECTRICIAN: IC. PLUMBER:—T_K1PL-E S -PL-UMEN11 HVAC: JCCV 1!J VF_ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION VING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: �11.�-,LF �x►i�Y F�eStb HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ All I VALUATION: $ i ''� TOTAL AREA: 24,2Z HEATED AREA: 2p9',j (Cost and Materials) R�UBLIC SEWER - NUMBER OF BEDROOMS: 4 ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: 411 SIZE WATER TAP: 3 SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE NUMBER OF BATHROOMS: Z- INTERIOR WALL TYPE: EXTERIOR WALL TYPE: 'BRiCGr.— FOUNDATION TYPE: N !�' mttE ROOF TYPE: DOUBLE [0' TRIPLE a ATTACHED E?r DETACHEP SIGNATURE OF APPLICANT: *If proposed work involves new commIlnrcial constr !ion commercial property, building elevation re r Ired. Official Plans Examiner C_ ru se Only Zoning Offal, ments: YE or NO le, Fire Marshall r Energ%y Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6- Development Services PLAN REVIEW/PERMIT NUMBER# ok,_ 9 a DATE: 3 /3i I ob BUILDING ADDRESS: boo I Ro,.a+a La.nle I. Foundation Requirements NA/ K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OA II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty (20) inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA7 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Re uirements to be indicated on plans N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward) 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N K A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage Vll. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N K A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side (intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision IT Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required tj CITY OF COLLEGE STATION Planning & Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLANS EXAMINER DATE iyiC � LV, Lrti06 4� j��;M, Y,�CI ° �t B!i�''vre Eng�nUfl't'l�rigs �1��, � �)7 �. 1i6 cGLU�E'�6tkYldf £�4iGdUce iON G'RYfYING,/NC•>l tH adc i "AV•CraIWOMAW, rfiMS7W-IXT6 B Lot 1 A Back 04 dwg Lot i Lnt 2 Now or Formerly Boman Road Meadows L.P. Now x Formerly Val 6118, Pq. 47 Barron Rood Maodaws L.P. Vol, 6118, Pg. 47 V . , � r v rr --- *? V. / J ReottC Lan& 50' R.aW Vo% 61 M Pg. 47 I Lot 17 Now Or Formerly SorMn Rood meadows L-P. Val. W `$, Pg_ 47 400l ReMMA �jq,3-zs-t5* `4. REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\4009RT.rck TITLE: 4001 REATTA LANE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 03/29/06 DATE OF PLANS: 6/3/05 PROJECT INFORMATION: REATTA MEADOWS LOT 18, BLOCK 4 COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: N. LEMKE COMPLIANCE: Passes Maximum UA = 493 Your Home UA = 402 18.5% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Front Projection factor: 0.23 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame with Thermal Break:Double Pane with Low-E SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Left Side Projection factor: 0.20 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2093 30.0 0.0 73 406 13.0 0.0 25 60 0.640 38 38 515 13.0 0.0 56 0.400 15 38 0.640 36 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Back Projection factor: 0.23 Door 2: Glass SHGC: 0.78 Bldg. faces 225 deg. from North; Comp. orient.: Back Projection factor: 0.56 Wall 4: Wood Frame, 16" o.c. Window 4: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Right Side Projection factor: 0.20 Air Conditioner 1: Electric Central Air, 13 SEER 387 13.0 0.0 115 18 481 13.0 0.0 58 21 0.640 74 0.580 10 35 0.640 37 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted,, it the permit application. a proposed building has been designed to meet the 2000 IECC requirements in--RES checkVersio�i 3 Rele se (formerl ME checl and to comply with the mandatory requirements listed in the R� hecklnspection Che i . Buil4e esigner Date 3 // /