HomeMy WebLinkAboutRES2006-00982b '. q tea
3Pendaffor
aEsselte
Amk
R 7521/3 100/OP4
Nicole Cochran - Re Calling for CO @ 4001 Reatta Lane Page 1
From: Joe Garcia
To: Benjamin McCarty; Chris Haver; Gina Southerla
Date: 11/14/2006 2:25:27 pm
Subject: Re: Calling for CO @ 4001 Reatta Lane
THIS ONE IS OK. JMG
>>> Nicole Cochran 11/14/06 8:07 AM >>>
Are there any issues?
BP# 06-982
Thanks!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.csb(.gov
WF0758756 /
001 City of Collecj�tion
PAGE 1
REQ. DATE:
04/07/06°'
04/07/06
14:39:36
LOCATION:
4001 REATTA LN
LOC ID:
200910
REQUESTOR:
ED FROEHLING BUILDER ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/07/06 SCHED COMPLETION:
04/07/06
********************************************************************************
JOB ORDER RESULT COMVIENTS
City of College Station
1101"TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . . . . . .
11/14/06
537300-0104-0180
4001 REATTA LN
COLLEGE STATION TX 77845
REATTA MEADOWS SEC 1 PH 1
REATTA MEADOWS, BLOCK 4, LOT 1
8
SINGLE FAMILY RESIDENTIAL
BARRON ROAD MEADOWS L.P.
ED FROEHLING BUILDERS
979 776-8266
06-00000982 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
A, -
Bu()ding GiTiZ�ial" "
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 11/14/06, 8:02:30 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/13/06
------------------------------------------------------------------------------------------------
ADDRESS . : 4001 REATTA LN SUBDIV: REATTA MEADOWS SEC 1 PH 1
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER BARRON ROAD MEADOWS L.P. PHONE
PARCEL 537300-0104-0180
APPL NUMBER: 06-00000982 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/25/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/25/06 AP May 25, 2006 10:59:44 AM kwolfe
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 7/13/06 JGM BLDG, FRAMING TIME: 17:00
7/13/06 AE July 13, 2006 9:38:40 AM bkorthauer
Sheetrock Fireplace Chase, Firestopping
B130 01 7/28/06 OC BLDG, INSULATION TIME: 17:00
7/28/06 AP July 27, 2006 4:36:50 PM glsouth
B125 01 11/13/06 �BII BLDG, FINAL TIME: 17:00
14- ryx November 13, 2006 2:27:45 PM glsouth
---------------------------------------- COMMENTS AND NOTES -----------------
b�
O-VAA �'[ M
Date: 11/14/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 982
Address: 4001 REATTA LN
Insp.
inspection Type Code
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
Sheetrock Fireplace Chase, Firestopping
P125
PLBG, FINAL
IC
Pressure Test Not Holding
Page 1
BUILDING PERMIT
CI PY: OFi COLLEGE STATION
1101TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . .'; 06-00000982 Date 4/07/06
Property Address . . . . . . 4001 REATTA LN
Property ID: 537300-0104-0180
R #: R300715
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . REATTA MEADOWS SEC 1 PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 138138
Owner
Contractor
------------------------
BARRON ROAD MEADOWS
------------------------
L.P. ED FROEHLING BUILDERS
PO BOX 277
ED FROEHLING
NORMANGEE
TX 778710277 3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2093.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
427.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
577.00 Plan Check Fee
.00
Issue Date . . . .
4/07/06 Valuation . . .
. 138138
Expiration Date . .
10/04/06
Qty Unit Charge Per Extension
BASE FEE 460.00
39.00 3.0000 THOU BLDG, VAL 100001-500000 117.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
BUILDING DEPT RREPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CI';Y OF; COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00000982 Date 4/07/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
-------------------------------------------- - ------ ------ ---- - --------
BUILDING DEPT REPRESENTATI�VyE}:� 110-
APPLICANT: W,,9v n/V1
BUILDING PERMIT
CITY OF't COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00000982 Date 4/07/06
----------------------------------------------------------------------------
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
-
--------- ------ ----- ------------------------ ------ --- - -- -:----------
BUILDING DEPT REPRESENTATIVE:
:
APPLICANT: � q'A /�1 M
BUILDING PERMIT
CITY OF.COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000982
Date 4/07/06
----------------------------------------------------------------------------
Special Notes and
Comments
PRIVATE GARAGES
Narrow wall bracing
Fully Sheathed
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
----------
577.00
577.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1327.00
1327.00
.00
.00
-
(
CITY OF COLLEGE STATION
Planning 6, Development Simko_
APPLICATION FdR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
For Office Use ly
DATE:L5 'L-�*14 PEG
APPLICATION # ��
TEMP POLE #
ADDRESS/L ATION: �tVV t t4cs l TIQ U
LOT BLOCK 1t' y SUBDIVISION E+Q►T��' FAA
M C1/s✓SEC/PH
BUSINESS/OWNER NAME:
PHONE:
5m % - PvIpeSE
CONTRACTOR/HOMEOWNER: Ed FF;Z0MALI1,4Ca BUIL XV, PHONE: "770'$26(a
CONTRACTOR ADDRESS:
9_4>6D cs-rx _n82,
ELECTRICIAN: IC. PLUMBER:—T_K1PL-E S -PL-UMEN11
HVAC: JCCV 1!J VF_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION VING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: �11.�-,LF �x►i�Y F�eStb
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
All I VALUATION: $ i ''� TOTAL AREA: 24,2Z HEATED AREA: 2p9',j
(Cost and Materials)
R�UBLIC SEWER - NUMBER OF BEDROOMS: 4
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP: 411
SIZE
WATER TAP: 3
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE
NUMBER OF BATHROOMS: Z-
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE: 'BRiCGr.—
FOUNDATION TYPE: N !�' mttE
ROOF TYPE:
DOUBLE [0' TRIPLE a
ATTACHED E?r DETACHEP
SIGNATURE OF APPLICANT:
*If proposed work involves new commIlnrcial constr !ion
commercial property, building elevation re r Ired.
Official
Plans Examiner
C_
ru
se Only
Zoning Offal,
ments:
YE or NO
le,
Fire Marshall
r
Energ%y Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6- Development Services
PLAN REVIEW/PERMIT NUMBER# ok,_ 9 a
DATE: 3 /3i I ob
BUILDING ADDRESS: boo I Ro,.a+a La.nle
I. Foundation Requirements
NA/ K
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
OA
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty (20) inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA7
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Re uirements to be indicated on plans
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward)
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N K
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
Vll. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N K
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
IT
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
tj
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLANS EXAMINER DATE
iyiC � LV, Lrti06 4� j��;M, Y,�CI ° �t B!i�''vre Eng�nUfl't'l�rigs �1��, � �)7 �. 1i6
cGLU�E'�6tkYldf £�4iGdUce iON G'RYfYING,/NC•>l tH adc i "AV•CraIWOMAW, rfiMS7W-IXT6 B
Lot 1 A Back 04 dwg
Lot i Lnt 2
Now or Formerly
Boman Road Meadows L.P. Now x Formerly
Val 6118, Pq. 47 Barron Rood Maodaws L.P.
Vol, 6118, Pg. 47
V
. , � r v rr --- *? V. / J
ReottC Lan&
50' R.aW
Vo% 61 M Pg. 47
I Lot 17
Now Or Formerly
SorMn Rood meadows L-P.
Val. W `$, Pg_ 47
400l ReMMA
�jq,3-zs-t5*
`4.
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\4009RT.rck
TITLE: 4001 REATTA LANE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/29/06
DATE OF PLANS: 6/3/05
PROJECT INFORMATION:
REATTA MEADOWS
LOT 18, BLOCK 4
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
N. LEMKE
COMPLIANCE: Passes
Maximum UA = 493
Your Home UA = 402
18.5% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2:
Metal Frame with Thermal Break:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Left Side
Projection factor: 0.20
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2093
30.0
0.0
73
406
13.0
0.0
25
60
0.640 38
38
515 13.0 0.0
56
0.400 15
38
0.640 36
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Door 2: Glass
SHGC: 0.78
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.56
Wall 4: Wood Frame, 16" o.c.
Window 4: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Right Side
Projection factor: 0.20
Air Conditioner 1: Electric Central Air, 13 SEER
387 13.0 0.0
115
18
481 13.0 0.0
58
21
0.640 74
0.580 10
35
0.640 37
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted,, it the permit application. a proposed building has been designed to meet the 2000 IECC
requirements in--RES checkVersio�i 3 Rele se (formerl ME checl and to comply with the mandatory requirements listed in
the R� hecklnspection Che i .
Buil4e esigner Date 3
// /