PREPARED 6/12/07, 12:00:12 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/12/07
------------------------------------------------------------------------------------------------
ADDRESS 4009 REATTAtLN_.((SUBDIV: REATTA MEADOWS SEC 1 PH 1
CONTRACTOR :""ED—FROEHLING BUILDERS PHONE (979) 776-8266
OWNER BARRON ROAD MEADOWS L.P. PHONE
PARCEL 537300-0104-0140
APPL NUMBER: 06-00000979 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/24/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
5/24/06 AP May 24, 2006 10:51:43 AM bkorthauer
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 7/06/06 OC BLDG, FRAMING TIME: 17:00
7/06/06 AP July 5, 2006 12:27:04 PM glsouth
B130 01 7/17/06 OC BLDG, INSULATION TIME: 17:00
7/17/06 AP July 17, 2006 10:29:44 AM bkorthauer
B125 01 6/12/,07 RI BLDG, BLDG, FINAL TIME: 17:00
AT" 00% 0C June 12, 2007 11:46:36 AM kwolfe.
------j----------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
��
Date: 6/13/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 979
Address: 4009 REATTA LN
Type
Inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
Page 1
WF0758757 / 001 City of College Station
PAGE 1
REQ. DATE:
04/07/06
04/07/06
14:43:04
LOCATION:
4009 REATTA LN
LOC ID:
200902
REQUESTOR:
ED FROEHLING BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/07/06 SCHED COMPLETION:
04/07/06
********************************************************************************
JOB ORDER RESULT COME TI'S
BUILDING PERMIT
CITY O`, _:,EGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------=----------------------------------------
Application Number
. . . . . 06-00000979 Date 4/07/06
Property Address .
. . . . . 4009 REATTA LN
Property ID:
537300-0104-0140
R #:
R300711
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . REATTA MEADOWS SEC 1 PH 1
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 138138
Owner
Contractor
------------------------
BARRON ROAD MEADOWS
------------------------
L.P. ED FROEHLING BUILDERS
PO BOX 277
ED FROEHLING
NORMANGEE
TX 778710277 3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2093.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
577.00 Plan Check Fee .00
Issue Date . . . .
4/07/06 Valuation . . . . 138138
Expiration Date . .
10/04/06
Qty Unit Charge Per Extension
BASE FEE 460.00
39.00 3.0000 THOU BLDG, VAL 100001-500000 117.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
--------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT :,nd,
✓W(,faAAI /y1 A A )) 4
BUILDING PERMIT
CITY OP COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00000979 Date 4/07/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
-
--------------- ----- ---------------- ----- ------ --- - -- -------------
BUILDING DEPT REnPRESENTATIVE:
APPLICANT:,-M(Y/11A/Y).T m
BUILDING PERMIT
CITY OF COL;,EGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000979
Page 3
Date 4/07/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
--------------------------------- ----- --- - '-------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:,--M,D/v)m 7�"v�L
BUILDING PERMIT
CITY OF COLj EGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number . . . . .
06-00000979
Date 4/07/06
----------------------------------------------------------------------------
Special Notes and Comments
SUCH THAT THE IGNITION SOURCE
IS 18" ABOVE THE
FLOOR
IN
PRIVATE GARAGES
Narrow wall bracing Fully Sheathed
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total 577.00
577.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1327.00
1327.00
.00
.00
-
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
r COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning 6, Devdopnnir Services.
ADDRESS/LOCATION:
LOT t * y BLOCK /4 V
BUSINESS/OWNER NAME:
DATE '3"OTICCC REG
APPLICATION # ! 1
TEMP POLE #
DIVISION REN-T-rA N1EAZ>Ct �l�j EC/PH aJ�GZ.ONE/PHt,
PHONE:
CONTRACTOR/HOMEOWNER: ED FF'2ce1 Ltt k �)tL,.pkyR1— H- : '7 4O - SUP(
o
CONTRACTOR ADDRESS: 3E$ A tG-ad RcAo , GST )(1-1bJ
ELECTRICIAN: PJ PLUMBER: TRIPLE S
HVAC: 1NlJOVATIVE SE YKES GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION OVING SHELL ONLY
DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: _sk F�l E F.IMIL-Y ResIcy ,t.1GE.
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ !A1304 1'36• 00 `� TOTAL AREA: 7407-Z. HEATED AREA: 2O'5
(Cost of Labor and Materials)
[�?ISUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 4"
SIZE
19-WATER TAP: SA # 1
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
DOUBLE EZ"' TRIPLE
ATTACHED LRJ:�ETACHEDnF] CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new Comm cis
commercial property, building elevations a
Plans Examiner
4A41t J II14
improvem
Official Use ONIv
15Q %C <
3 %2q lOCr
to an existing
Zoning Official Fire Marshall
m ents:
or NO
40 12Fz7A-rrA. LA►JE ,. ,
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
l 3.2.E a7v r/
13
30
-4O
/
13'eew-
r�
Y�
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# &. - `1-79 DATE: 3 /.31 / 06
BUILDING ADDRESS: qOO 9 ZOPACI L-AI&
I. Foundation Requirements
N K
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
N
. 4,
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
Il. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/00
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
(*f/q"
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NAM
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N O
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
KAIJW
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
NAfM
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
, r
�ll
CITY OF COLLEGE STATION
Planning d' Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
Ak 4 t _
,3r-o(
A S EXAMINER DATE
Mar, 2 , 26 4S P M Vic(,'!ure & blown- Eng/Survejing, N.1, llb% N. 2,"b
Atat1AFdSi'V#Wf,�f�G/NFEie'R"RhWXWC-fAWAM-IWGs►A,&APfOJ-C SNAw,, rv"s)W, /VVj MAJAW
Lot 14 Block 04.dwg
Lot 4
Now or Formerly
Eamon Rood Usodows LP.
Vol. 611t1, Pg. 47
,.1
I
I
SCd18: 1" - 20' I
• B.S.L
Lot 15 i
Now or roemcrly
BOIrOA R604 M0440r4 L.P.
VOL 6118, Pg. 47 i
i
I
I
Lot 5 Loi 8
New or Formerly Now or Forrnerly
Sorron Road Moodows L.P. Barron Rood Meadows L.P.
'Vol, 6115,PS 47V 1 Vol, 5118, Pg. 47
S 46357-b0" F — 60,Of
—20' P.U.E.
n
h
Y
NOW Wig, Setback erns
per Anal Plat (6118/47)
44.5' 7.7
Lot 14, Black 4
Reatto Moadows
Subdvkaha
Proposed
Residency'
_...�..„J 7.8' 44.5'
bw
N 4548Y8' W -- sa G'4'
Reatta Lane
50' R. a w.
8118, Plg. 47
L.
Lot 13
Now or i ormerly
Borror. Rood Meodows L.P.
Vol, 6118, Pg, 47
1 J
4co!
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\913DL.rck
TITLE: 4009 REATTA LANE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/29/06
DATE OF PLANS: 6/3/05
PROJECT INFORMATION:
REATTA MEADOWS
LOT 14, BLOCK 4
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
N. LEMKE
COMPLIANCE: Passes
Maximum UA = 493
Your Home UA = 402
18.5% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window l: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2:
Metal Frame with Thermal Break:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Left Side
Projection factor: 0.20
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2093
30.0
0.0
73
406
13.0
0.0
25
60
0.640 38
38
515
56
13.0 0.0
0.400 15
38
0.640 36
Wall 3: Wood Frame, 16" o.c.
387 13.0 0.0 21
Window 3: Metal Frame:Double Pane with Low-E
115 0.640 74
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Door 2: Glass
18 0.580 10
SHGC: 0.78
,.
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.56
Wall 4: Wood Frame, 16" o.c.
481 13.0 0.0 35
Window 4: Metal Frame:Double Pane with Low-E
58 0.640 37
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Right Side
Projection factor: 0.20
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit applicatio a
roposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (fo erly ME
chec4 and to comply with the mandatory requirements listed in
the REScheckInspecti ec 'st.
Builder/Designe
z, ,DU
Date