HomeMy WebLinkAboutRES2006-00972, 06-973I
I
PREPARED
7/24/06,
12:08:40
INSPECTION TICKET
PAGE 15
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 7/24/06
------------------------------------------------------------------------------------------------
ADDRESS
. : 1714 NORTH BARDELL
CT SUBDIV: THE GLADE
12
CONTRACTOR
B A CATHEY
PHONE (979) 255-7064
OWNER
7B INVESTMENTS
PHONE
PARCEL
290500-1200-0010
APPL NUMBER: 06-00000972
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------7-----------------
PERMIT=
BLDG 00 BUILDING
PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/19/06
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
4/19/06
AP
April 19, 2006 10:41:10 AM malford
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/07/06
RH
BLDG, FRAMING TIME: 17:00
6/07/06
AE
June 6, 2006 10:40:12 AM kwolfe
06/07/2006 02:25 PM RH PDA
Add anchors and let -in braces.
B115 02
6/09/06
DS
BLDG, FRAMING TIME: 17:00
;f
6/09/06
CA
June 8, 2006 2:32:19 PM kwolfe
June 9, 2006 11:44:23 AM bkorthauer
CANCELLED WRONG INSPECTION
1�130 01
6/09/06
DS
BLDG, INSULATION TIME: 17:00
6/09/06
AP
June 9, 2006 11:44:47 AM bkorthauer
June 9, 2006 11:45:03 AM bkorthauer
B125 01
7 24/06
BLDG, FINAL TIME: 17:00
(BZl�
KJ
July 24, 2006 11:28:07 AM glsouth
------------
(3--------------
----- COMMENTS AND NOTES ------------------------------------
Date: 7/24/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 972
Address: 1714 NORTH BARDELL CT
Type
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/07/2006 02:25 PM RH PDA
B115
BLDG, FRAMING
IC
Add anchors and let -in braces.
B115
BLDG, FRAMING
IC
June 9, 2006 11:44:23 AM bkorthauer
B115
BLDG, FRAMING
IC
CANCELLED WRONG INSPECTION
B130
BLDG, INSULATION
IC
June 9, 2006 11:45:03 AM bkorthauer
P125
PLBG, FINAL
IC
All Electric No Gas
Page 1
WF0757398 /
001
City of College
Station
PAGE 1
REQ. DATE:
04/03/06
w
04/03/06
16:38:17
LOCATION:
1714 NORTH
BARDELL CT
LOC ID:
203336
REQUESTOR:
B A CATHEY
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH
AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
SWR 4"
WTR 3/411
********************************************************************************
TASK:
SET UP NEW
UTILITY ACCT
SET
READY
SCHED START:
04/03/06
SCHED
COMPLETION:
04/03/06
JOB ORDER RESULT COMIENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
El
P E R M A N E N T
Issue Date . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work .
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . . . . . .
7/25/06
290500-1200-0010
1714 NORTH BARDELL CT
COLLEGE STATION TX 77840
THE GLADE 12
THE GLADE #12, B
LOCK A-R, LOT 1
SINGLE FAMILY RESIDENTIAL
7B INVESTMENTS
B A CATHEY
979 255-7064
06-00000972 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Officia
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS; _,AV-R•J
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000972 Date 4/03/06
Property Address . . . . . . 1714 NORTH BARDELL CT
Property ID 290500-1200-0010
R #
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . THE GLADE 12
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 90090
Owner Contractor
------------------------ ------------------------
7B INVESTMENTS B A CATHEY
1305 W VILLA MARIA PO BOX 9517
BRYAN TX 77801 COLLEGE STATION TX 77842
(979) 255-7064
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 1365.00
INTERIOR WALL TYPE GYPSUM
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 345.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc GS
Permit Fee . . . . 424.00 Plan Check Fee .00
Issue Date . . . . 4/03/06 Valuation . . . . 90090
Expiration Date . . 9/30/06
Qty Unit Charge Per Extension
BASE FEE 260.00
41.00 4.0000 THOU BLDG, VAL 50001-100000 164.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQ IPMENT AND WALKWAY
-------------------------------------------- ----- -- ;-----------
BUILDING DEPT REPRESENTATIVE: •
nti
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE,
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000972
Page 2
Date 4/03/06
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN -DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
-- ----- ----------------------- ------ --- ---'-- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: l U'9Ul/
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000972
Page 3
Date 4/03/06
Special Notes and Comments
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow wall bracing Prescriptive 41X8' OSB
Other Fees SEWER TAP 4"
WATER TAP 3/4"
350.0C
400.00
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 424.00 424.00 .00 .00
Plan Check Total .00 .0 .00 .00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - •._ -----------
BUILDING DEPT REPRESENTATI/171' -:�J/
APPLICANT: II/ 1-v
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE,
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000972
Other Fee Total 750.00 750.00
Grand Total 1174.00 1174.00
Page 4
Date 4/03/06
.00 .00
.00 .00
---------------------------- ----- --- - :------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000973 Date 4/03/06
Property Address . . . . . . 1714 NORTH BARDELL CT
Property ID 290500-1200-0010
R # .
Application type description TEMP POLE
Subdivision Name . . . . . . THE GLADE 12
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
7B INVESTMENTS
------------------------
B A CATHEY
1305 W VILLA MARIA
PO BOX 9517
BRYAN
TX 77801,
COLLEGE STATION
TX 77842
(979) 255-7064
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
GS
Permit Fee . . . .
20.00
Issue Date . . . .
4/03/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
------------------------------------------- ------ -- -'------------
BUILDING DEPT REPRESENTA IVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning d• DewlnpmentSe'miceJ,
ADDRESS/LOCATION:
LOT __V BLOCK _
�
SUBDIVISION
For ONke Use Only
DATE f TRCC REGa
APPLICATION
TEMP POLE #
SEC/PH
BUSINESS/OWNER NAME:i�pt. �H,u� PHONE:
r2SS���Io�
CONTRACTOR/HOMEOWNER: p�Ac%Q �I ,�.� PHONE: S7`[-03-7y-
CONTRACTOR ADDRESS:
ELECTRICIAN:
PLUMBER:
HVAC: T/1 L_,e� GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION` SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD TAS)) PROJECT ISTRATION# E`AABPPRJ
VALUATION: $ OI.UD TTAL AREA:y/�� HEATED AREA: 43&
(Cost of Labor and Materials) z4
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
R/ SEWER TAP:
SIZE
a WATER TAP:
3
SIZE
OTHER TAP:
SIZE
[ ' I EMP POLE
GARAGE TYPE: SINGLE a
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F-] TRIPLE
ATTACHED 1 1 DETACHED 1 1 CARPORT
R
Z-
�s/7
/ .Une/e-1
0
SIGNATURE OF APPLICAN .
*If proposed work involves omm rclal co struction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
Plans Examiner Zoning Official Fire Marshall
9 Cilkn ents:
/ /aS� or NO
Energy Code Compliance Ififormation
i
% Glazing of exterior walls
Insulation R value of exterior walls / 3
Insulation R value of ceiling 1 (flat areas) 52
Insulation R value of ceiling 2 (vaulted areas/no attic) M
Glazing SHGC ' �b
Glazing U-Factor ,?S
R value of ductwork
A/C SEER Rating )--s /,*"
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER#
6)& ., q qa-
DATE:
BUILDING ADDRESS: Irliq
0#—+,
u 0.
I. Foundation Requirements
NA/qW
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of's an indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
CITY OF COLLEGE STATION
Planning d' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA
'r
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
-k K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6) inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
Y,
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
NAjbfl
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
zx�t�- t- 3-31-0(
LANS EXAMINER DATE