Loading...
HomeMy WebLinkAboutRES2006-00946, 06-947(OLVIN4 LJL..-46�41 w GAP Kim Wolfe Re: Calling for CO @ 3905 Bridgeberry Ct Page 171 From: Paul Schoenfeld To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wolfe; Mitchell Carson; Nicole Cochran; Terry Boriskie Date: 10/9/2006 2:26:27 PM Subject: Re: Calling for CO @ 3905 Bridgeberry Ct All is OK Paul S >>> Kim Wolfe 10/9/2006 12:07 PM >>> Are there any issues? BP # 06-946 Thanks Kimberly Wolfe City of College Station Planning & Development Services (979) 764-3570 www.cstx.gov PREPARED 10/09/06, 11:59:18 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/09/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 3905 BRIDGEBERRY CT SUBDIV: WESTFIELD VILLAGE PH 4 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0409-0030 APPL NUMBER: 06-00000946 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/09/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 5/09/06 AP May 9, 2006 10:47:04 AM bkorthauer Strings On Setbacks O.K. Slab Ground Installed B115 01 7/11/06 JGM BLDG, FRAMING TIME: 17:00 7/12/06 DP July 11, 2006 8:31:21 AM kwolfe July 12, 2006 9:52:53 AM glsouth NEED TO SUPPORT RAFTER SPLICESOVER LIVING ROOM. REMOUNT ELEC BOX IN UTILITY ROOM. B115 02 7/12/06 JGM BLDG, FRAMING TIME: 17:00 7/12/06 AP July 12, 2006 11:41:21 AM glsouth B130 01 7/14/06 RH BLDG, INSULATION TIME: 17:00 7/14/06 DP July 14, 2006 9:35:29 AM bkorthauer 07/14/2006 03:56 PM RH PDA Seal all penetration into attic and through exterior walls. Did not completely insulate behind large shower stall. B130 02 7/17/06 RH BLDG, INSULATION TIME: 17:00 7/17/06 DP July 17, 2006 8:25:04 AM bkorthauer 07/17/2006 03:09 PM RH PDA Did not insulate behind large shower stall. B130 03 7/18/06 OC BLDG, INSULATION TIME: 17:00 7/18/06 AP July 17, 2006 3:05:15 PM bkorthauer B132 01 7/21/06 JGM BLDG, SHEETROCK FASTENER TIME: 17:00 7/21/06 AP July 21, 2006 8:52:21 AM bkorthauer B125 01 10/09/06 BLDG, FINAL TIME: 17:00 le) gb(1„ L�� * OVERRIDE TAKEN BY GLSOUTH DATE: 10/09/06 TIME: 09:12:10 '—`� October 9, 2006 9:12:07 AM glsouth a----------------------------------- CONTINUED ONTO NEXT PAGE ---------------------------- 4------- Date: 10/9/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 946 Address: 3905 BRIDGEBERRY CT In p Inspection Type Code Description se tus Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC July 12, 2006 9:52:53 AM glsouth B115 BLDG, FRAMING IC NEED TO SUPPORT RAFTER SPLICESOVER LIVING ROOM. B115 BLDG, FRAMING IC REMOUNT ELEC BOX IN UTILITY ROOM. B130 BLDG, INSULATION IC 07/14/2006 03:56 PM RH PDA B130 BLDG, INSULATION IC Seal all penetration into attic and through exterior B130 BLDG, INSULATION IC walls. Did not completely insulate behind large shower B130 BLDG, INSULATION IC stall. B130 BLDG, INSULATION IC 07/17/2006 03:09 PM RH PDA 13130 BLDG, INSULATION IC Did not insulate behind large shower stall. M110 MECH, FINAL IC 09/06/2006 02:41 PM RH PDA M110 MECH, FINAL IC Need t-stat by building final. Page 1 WF0757706 / 001 City of-_Colglege Station PAGE 1 REQ. DATE: 04/04/06 04/04/06 16:44:48 LOCATION: 3905 BRIDGEBERRY CT LOC ID: 203740 REQUESTOR: STYLECRAFT BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/04/06 SCHED COMPLETION: 04/04/06 ******************************************************************************** JOB ORDER RESULT COMIENTS BUILDING PERMIT CITY,-Q.F_,,,..C,OLLEGE STATION 11011 TEXAS--AVE COLLEGE` STATION;.. TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- a. Application Number . . . . 06-00000946 Date 4/04/06 Property Address . . . . . . 3905 BRIDGEBERRY CT Property ID . . 005401-0409-0030 R# . . . . . . . . . . . . . Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 80190 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1215.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc GS Permit Fee . . . . 384.00 Plan Check Fee .00 Issue Date . . . . 4/04/06 Valuation . . . . 80190 Expiration Date . . 10/01/06 Qty Unit Charge Per Extension BASE FEE 260.00 31.00 4.0000 THOU BLDG, VAL 50001-100000 124.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211 -------------------------- BUILDING DEPT REPRESENTATIVE: ------ -- -"- _ �� -------------- APPLICANT: BUILDING PERMIT CITY;OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000946 Page 2 Date 4/04/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO -------------------- - -- ----A--- - -- -------------- BUILDING DEPT REPRESENTATIVE: QV///► APPLICANT: BUILDING PERMIT CITY,OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000946 Page 3 Date 4/04/06 Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ------------------------------------------- ------ --- ----- -.------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY,OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000946 Date 4/04/06 ---------------------------------------------------------------------------- Special Notes and Comments Narrow wall bracing by Engineered Methods. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 384.00 384.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1134.00 1134.00 .00 .00 ------------ ---------- -- BUILDING DEPT REPRESENTATIVE-: : APPLICANT: --A--'- ----------- TEMPORARY POLE PERMIT CITY.OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000947 Date 4/04/06 Property Address . . . . . . 3905 BRIDGEBERRY CT Property ID . . 005401-0409-0030 R# . . . . . . . . . . . . . Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 4/04/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - APPLICANT: Use only I y4 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Pfanning&Da Iopm ntSrruica VFW CSTX.GOV DATE: 7`�" �' 0 UTRCC( R�EG APPLICATION # TEMP POLE # ADDRESS/LOCATION: ,�905 Spwxaaa =RR�I CoU2T LOT 3 .,-- BLOCK "51 /SUBDIVISION WESTFiEL0 VILLAC^aE/ SEC/PH 4 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: NT TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 80 H O TOTAL AREA: 1-110 HEATED AREA: 1-115 (Cost of Labor and Materials) FX PUBLIC SEWER NUMBER OF BEDROOMS: 3 ❑ SEPTICITREATMENT SYSTEM NUMBER OF BATHROOMS: Z X SEWER TAP: 4" SIZE OX WATER TAP: 3/a° SIZE ❑ OTHER TAP: �4� X TEMP POLE GARAGE TYPE Ira "l JILt SINGLE ATTACHED EX INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition DOUBLE F__1 TRIPLE DETACHED F__] CARPORT SIGNATURE OF APPLICANT: For For Stvlecraft *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only �b 3-3a'a. Plans Examiner L AS Zoning Official omments: (21 S o NO 1W Energy Code Compliance Information % Glazing of exterior walls l 1 % Insulation R value of exterior walls R13 -'-- Insulation R value of ceiling 1 (flat areas) R30---- Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC Glazing U-Factor .63' R value of ductwork R6 A/C SEER Rating 13' 13 i V CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# d lO _ 9 1 DATE: 3 /3,o BUILDING ADDRESS: o 5- 3e . I. Foundation Requirements NAAKJ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated 1-14A II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/aj A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning fY Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N O 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes N III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal CITY OF COLLEGE STATION Planning 6 Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements NAW A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) F B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NAM Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required lei' (*hr"" CITY OF COLLEGE STATION Planning cd Development Services Comments: r- PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS .30 -olo DATE Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheck So$ware Version 3.6 Release 2 Data filename: S:\ACAD\Archived\Old REScheck\1215_3905 Bridgeberry Court.rck .. :, PROJECT.TTTLE: PLAN #121513-WV CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.12 DATE: 03/28/06 DATE OF PLANS: 03/28/06 PROJECT DESCRIPTION: Wilkerson 3905 Bridgeberry Court College Station, Texas DES IGNER/CONTRACTOR: Stylecra$ Builders, hie. 4090 St. Hwy. 6 S. College Station, Texas 77845 OMPLIANCE:_Passes Maximum UA = 564 Your Home UA = 461 18.3% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R Value U-Factor 3J. Ceiling 1: Flat Ceiling or Scissor Truss 864 30.0 0.0 30 Ceiling 2: Cathedral Ceiling (no attic) 380 19.0 0.0 20 Wall 2: Wood Frame, 16" o.c. 1376 13.0 0.0 96 Window 4: Metal Frame, Double Pane with Low-E 150 0.670 101 SHGC: 0.40 Door 3: Solid 38 0.500 19 Door 5: Glass 18 0.440 8 SHGC: 0.40 Floor 1: Unheated 179 0.0 187 Insulation depth: 0.0' Air Conditioner 1:.Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Date 3- 2g - C)(o REScheck Inspection Checklist 2000 IECC REScheck Sollware Version 3.6 Release 2 DATE: 03/28/06 PROJECT TITLE: PLAN #1215B-WV Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe katures: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 3: Solid, U-factor. 0.500 Comments: [ ] 2. Door 5: Glass, U-factor: 0.440 Comments: Floors: [ ] 1. Floor 1: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number [ ] 2. Furnace 1: Forced Hot Air, 80 AFUE or higher I Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 1 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the I levels in Table 2. Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating_ Mains and Runouts Temperature ( F) Up to 1„ Un to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pining System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5 , to 4„ Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (fir feed water) Cooling Systems Chilled Water, Refrigerant, and Brine 201-250 1.0 1.5 1.5 2.0 120-200 0.5 1.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Name Mrs -me Window Area Total: 146.83 03/28/0613:09:22 1 /1 Area Calculator: goo Assembly T pe Comments/ Description Opaque door solid masonite Door Area Total: 55.56 03/28/06 13:09:22 1 /1 Area Calculator: Assembly.: Comments/Descrlptlon Ceiling Area Total: 1215.00 03/28/06 13:09:23 1 /1 Area Calculator: Assembly.: KM -T-Imm Comments/Description Exterior Wall Area Total: 1360.00 03/28/06 13:09:23 1 /1 Area Calculator: Assembly.: Comments/Description m■�■�� Floor Area Total: 0.00 03/28/06 13:09:23 1/1