Loading...
HomeMy WebLinkAboutRES2006-00944, 06-945PREPARED 9/01/06, 8:02:13 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/31/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 932 CRESTED POINT DR SUBDIV: WESTFIELD VILLAGE PH 4 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . y PHONE PARCEL . . 005401-0410-0120 APPL NUMBER: 06-00000944 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/18/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/18/06 AP April 18, 2006 10:07:34 AM kwolfe Strings On Setbacks O.K. Slab Ground Installed B115 01 6/12/06 BI BLDG, FRAMING TIME: 17:00 6/12/06 CA June 12, 2006 4:04:55 PM kwolfe B115 02 6/14/06 JGM BLDG, FRAMING TIME: 17:00 6/14/06 AE June 13, 2006 3:23:32 PM glsouth 06/14/2006 11:05 AM JGM PDA need to add pins to sole plate 16" o.c. in kitchen B130 01 6/19/06 OC BLDG, INSULATION TIME: 17:00 6/19/06 AP June 19, 2006 9:09:50 AM kwolfe B132 01 6/21/06 RH BLDG, SHEETROCK FASTENER TIME: 17:00 �_. 6/21/06 AP June 21, 2006 9:42:45 AM glsouth B125 02 8/ 1/ 6 BI BLDG, FINAL TIME: 17:00 August 31, 2006 2:16:05 PM glsouth B125 01 8/3 /06 BI BLDG, FINAL TIME: 17:00 8/31/06 CA August 30, 2006 3:45:38 PM glsouth 08/31/2006 11:35 AM RH PDA Waiting on electrical to be approved. -------------------------------------- COMMENTS AND NOTES -------------------------------------- A�,�T Kim Wolfe Re Calling for CO @ 932 Crested Point Dr Page 1 From: Joe Garcia To: Kim Wolfe Date: 9/5/2006 10:09:45 AM Subject: Re: Calling for CO @ 932 Crested Point Dr THIS ONE IS GOOD TO GO. THANKS, JMG >>> Kim Wolfe 09/05/06 9:11 AM >>> Are there any issues? Thanks Kimberly Wolfe City of College Station Planning & Development Services (979) 764-3570 WWW.cstx.goy Date: 9/5/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 944 Address: 932 CRESTED POINT DR Insp. inspection Type Code Description p. status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC 06/14/2006 11:05 AM JGM PDA B115 BLDG, FRAMING IC need to add pins to sole plate 16" o.c. in kitchen B125 BLDG, FINAL IC 08/31/2006 11:35 AM RH PDA B125 BLDG, FINAL IC Waiting on electrical to be approved. E110 ELEC, ROUGH IN IC 06/14/2006 11:03 AM JGM PDA E110 ELEC, ROUGH IN IC smoke detector in first bedroom needs proper clearance E110 ELEC, ROUGH IN IC from ceiling fan E150 ELEC, FINAL IC 08/31/2006 10:30 AM RH PDA E150 ELEC, FINAL IC need min 3ft from smoke detector from fans in bedroom. E150 ELEC, FINAL I IC fans were installed but it is wired for fan. Page 1 WF0759484 / 001 City of College Station PAGE 1 REQ. DATE: 04/11/06 04/11/06 14:10:42 LOCATION: 932 CRESTED POINT DR LOC ID: 203848 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/11/06 SCHED COMPLETION: 04/11/06 JOB ORDER RESULT COM VIE TI'S WF0757711 / 001 City of College Station PAGE 1 REQ. DATE: 04/04/06 , 04/04/06 16:54:36 LOCATION: 932 CRESTED POINT DR a ?' LOC ID: 203848 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/04/06 SCHED COMPLETION: 04/04/06 ******************************************************************************** JOB ORDER RESULT COMVIE TTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION-,- 7k 77840 PHONE: (979)764-3570 FAk: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000944 Date 4/04/06 Property Address . . . . . . 932 CRESTED POINT DR Property ID . . . . . . . . . 005401-0410-0120 R# . . . . . . . . . . . . . Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 75834 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1149.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 364.00 Plan Check Fee .00 Issue Date . . . . 4/04/06 Valuation . . . . 75834 Expiration Date . . 10/01/06 Qty Unit Charge Per Extension BASE FEE 260.00 26.00 4.0000 THOU BLDG, VAL 50001-100000 104.00 ---------------------------------- ----------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM OUGH-FRAMED SIZE 22" -------------------- ------- ----- --- - -- ------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: J& 1446� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TAX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000944 Page 2 Date 4/04/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ------------------------------------------------- ------.---------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, T!K 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000944 Page 3 Date 4/04/06 Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ------------------------------- --------------- BUILDING DEPT REPRESENTATIVE- - - - - -- ---- : _---- �__ --- A� ._�� APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000944 Date 4/04/06 ---------------------------------------------------------------------------- Special Notes and Comments Narrow wall bracing by Engineered Methods. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 364.00 364.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1114.00 1114.00 .00 .00 -------------------------------------------- BUILDING DEPT REPRESENTATIVE: _ APPLICANT: ---- - - - ----------- TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, 'fX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000945 Date 4/04/06 Property Address . . . . . . 932 CRESTED POINT DR Property ID . . 005401-0410-0120 R# . . . . . . . . . . . . . Application type description TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 4/04/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 --------------------------- Fee summary ------------------------------------------------ Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------- ------ - -'----------- BUILDING DEPT REPRESENTATIVE: APPLICANT: 1401- ���e� a 0 17e Use Only 11) APPLICATION FOR BUILDING PERMIT DATE: �� O" TRC,�C REG CITY OF COLLEGE STATION APPLICATION # U "(`LN 1101 TEXAS AVENUE /��A 11 � COLLEGE STATION, TX 77840 TEMP POLE # LQ-`_ ` l 6 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning& Development Services WWW.CSTX.GOV / ADDRESS/LOCATION: 9?;2 CRESTED Po 1 1.rr-r-_ LOT 11. BLOCK 10 /SUBDIVISION WF--STFIE�D\/ILLAe,pa- / SEC/PH�/ BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: N fA TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ -16,'3 TOTAL AREA: ISS8 HEATED AREA: l 149 (Cost of Labor and Materials) lD ` �X PUBLIC SEWER NUMBER OF BEDROOMS: 3 ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: rQ X SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE �X WATER TAP: 3/a" EXTERIOR WALL TYPE: Siding and/Or Masonry [_S SIZE L' OTHER TAP: FOUNDATION TYPE: Slab On Grade SIZE TEMP POLE ROOF TYPE: Composition 1 1 GARAGE TYPE: SINGLE F__j DOUBLE F-] TRIPLE C ATTACHED aX DETACHED F] CARPORT SIGNATURE OF APPLICANT: For St lecraft *If proposed work involves new c mmercial constr6clion or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only C Ments: -3o,C% <J"rNO f Plans Examiner Zoning Official 4Kt- w/ tr Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating I �l % R13 R30 R19 .65 13 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d' Development Services PLAN REVIEW/PERMIT NUMBER# k, _ DATE: 3 Av /o(o BUILDING ADDRESS: 13 a w I. Foundation Requirements NA/j0Kj A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated Ai - If. Framing: Floor, Wall, Ceiling and Roof Requirements fN4 A/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, rade, slope and purlins if required. JL CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS F�1 Il. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N O 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes Ill. Stairway Requirements A/ K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four (4) inch sphere IV. Fireplace Requirements to be indicated onplans) K A. Hearth extensions Uy 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements NA/0<1 A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NA/ K A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VI1. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) V111. Energy Requirements NA/ A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side (intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 K Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning & Development Services Comments: V,-,W -- - ANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 3-3a-0(,o DATE Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheck So$ware Version 3.6 Release 2 Data filename: S:\ACAD\Archived\Old REScheck\l 149C 932 Crested Point.rck PROJECT TITLE: Plan # 1149C-WV CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.14 DATE: 03/28/06 DATE OF PLANS: 03-28-2006 PROJECT DESCRIPTION: SPEC 932 Crested Point College Station, Texas DESIGNER/CONTRACTOR: Stylecrail Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: P;;ss? Maximum UA = 521 Your Home UA = 440 15.5% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter ValueU Fac or -VA Ceiling 1: Flat Ceiling or Scissor Truss 845 30.0 0.0 30 Ceiling 2: Cathedral Ceiling (no attic) 294 19.0 0.0 15 Wall 1: Wood Frame, 16" o.c. 1186 13.0 0.0 81 Window 1: Metal Frame, Double Pane with Low-E 132 0.650 86 SHGC: 0.40 Door 1: Solid 38 0.500 19 Door 2: Glass 33 0.580 19 SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated 182 0.0 190 Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Y Date 3 - O(a �-t2' 6. �ltl REScheck Inspection Checklist 2000 IECC REScheck Software Version 3.6 Release 2 DATE: 03/28/06- PROJECT TITLE: Plan # 1149C-WV Bldg. Dept. Use [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation , Comments: Windows: 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor. 0.500 Comments: 2. Door 2: Glass, U-factor. 0.580 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Area Calculator: IMI Window Name Assembly Type Comments/ Description Window Area Total: 132.00 03/28/06 10:25:29 1 /1 Area Calculator: IMINIIIIIIIEVVII I Assembly pe =01MIMMEMM— Description Opaque door solid ��■�■����� imp Door Area Total: 71.11 03/28/06 10:25:29 1 /1 Area Calculator: Assembly Type Comments/Description WTI M. Ceiling Area Total: 1139.00 03/28/06 10:25:29 1 /1 Area Calculator: Mi; Assembly Type Comments/Description Exterior Wall Area Total: 1186.67 03/28/06 10:25:30 1 /1 Area Calculator: Assembly Type- Comments/Description Floor Area Total: 0.00 03/28/06 10:25:30 1 /1