INSPECTION TICKET
PAGE 19
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 8/04/06
------------------------------------------------------------------------------------------------
ADDRESS
. : 909 CRESTED
POINT DR
SUBDIV: WESTFIELD VILLAGE
PH 4
CONTRACTOR STYLECRAFT
BUILDERS
PHONE (979) 690-1222
OWNER .
.
PHONE
PARCEL .
. 005401-0408-0050
APPL NUMBER: 06-00000942
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING
PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/18/06
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
4/18/06
AP
April 18, 2006 10:07:17 AM kwolfe
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
6/14/06
JGM
BLDG, FRAMING TIME: 17:00
6/16/06
AE
June 14, 2006 10:37:37 AM bkorthauer
06/16/2006 08:10 AM JGM PDA
remount switch box in bedroom, draftstop all chases
B130 01
6/23/06
RH
BLDG, INSULATION TIME: 17:00
6/23/06
AP
June 19, 2006 9:09:31 AM kwolfe
06/23/2006 10:11 AM RH PDA
was approved on 6-19-06
B132 01
6/23/06
RH
BLDG, SHEETROCK FASTENER TIME: 17:00
6/23/06
AP
June 22, 2006 9:41:53 AM bkorthauer
06/23/2006 10:13 AM RH PDA
Noted as a reminder to the electrician to have
min. 3ft of
clearance from ceiling fan blades and a/c vent.
B125101
8/04/06
BI
BLDG, FINAL TIME: 17:00
U(
P o C_
August 4, 2006 8:20:06 AM kwolfe
----------------------------------- CONTINUED ONTO NEXT PAGE-----------------------------------
Cr j e to 11, 15 1 lls�% CW
Date: 8/4/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 942
Address: 909 CRESTED POINT DR
Type
Inspection Type Code
Description
status
B100
BLDG, FOUNDATION -SLAB
IC
B100
BLDG, FOUNDATION -SLAB
IC
B115
BLDG, FRAMING
IC
B115
BLDG, FRAMING
IC
B130
BLDG, INSULATION
IC
B130
BLDG, INSULATION
IC
B132
BLDG, SHEETROCK FASTENER
IC
B132
BLDG, SHEETROCK FASTENER
IC
B132
BLDG, SHEETROCK FASTENER
IC
Ell
ELEC, ROUGH IN
IC
Ell
ELEC, ROUGH IN
IC
Page 1
Date: 8/4/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 942
Address: 909 CRESTED POINT DR
Inspection Result Comments
Strings On Setbacks O.K.
Slab Ground Installed
06/16/2006 08:10 AM JGM PDA
remount switch box in bedroom, draftstop all chases
06/23/2006 10:11 AM RH PDA
was approved on 6-19-06
06/23/2006 10:13 AM RH PDA
Noted as a reminder to the electrician to have min. aft of
clearance from ceiling fan blades and a/c vent.
06/14/2006 02:33 PM RH PDA
Smoke detector needs min. 3 ft. from ceiling fan blades.
Page 1 b
WF0759483 /
001 City of College
Station
PAGE 1
REQ. DATE:
04/11/06
04/11/06
14:10:04
LOCATION:
909 CRESTED POINT DR
LOC ID:
203782
REQUESTOR:
STYLECRAFT BUILDERS
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
04/11/06 SCHED
COMPLETION:
04/11/06
********************************************************************************
JOB ORDER RESULT
COMvIK TTI'S
WF0756792 / 001 City of College. "station PAGE 1
REQ. DATE:
03/31/06
03/31/06
9:20:13
LOCATION:
909 CRESTED POINT DR
LOC ID:
203782
REQUESTOR:
STYLECRAFT BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
03/31/06 SCHED COMPLETION:
03/31/06
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY OF COr,LEGE STATION
1101 TEXAS AVE
COLLEGE STATION, '1*k:t-', i40
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000942 Date 3/31/06
Property Address . . . . . . 909 CRESTED POINT DR
Property ID: 005401-0408-0050
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 75834
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
SIDING
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1149.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
364.00 Plan Check Fee
.00
Issue Date . . . .
3/31/06 Valuation . .
. . 75834
Expiration Date . .
9/27/06
Qty Unit Charge Per Extension
BASE FEE 260.00
26.00 4.0000 THOU BLDG, VAL 50001-100000 104.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
-------------------------------------------- ------ ---- --'-- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000942
Page 2
Date 3/31/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
-
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, 'fX 77�40
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 06-00000942 Date 3/31/06
----------------------------------------------------------------------------
Special Notes and Comments
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
---------------------------------------------------�r--'-------------
BUILDING DEPT REPRESENTATIVE: , aw�
APPLICANT.� V
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77640
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000942
Date 3/31/06
----------------------------------------------------------------------------
Special Notes and
Comments
Narrow wall bracing
by Engineered
Methods.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
----------
364.00
364.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1114.00
1114.00
.00
.00
-------------------------------------- - - - - ------- - - - - -- --------- - - - - --
BUILDING DEPT REPRESENTATIVE:
APPLICANT
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TAX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000943 Date 3/31/06
Property Address . . . . . . 909 CRESTED POINT DR
Property ID: 005401-0408-0050
Application type description TEMP POLE
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/31/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------------------------------------- ----- --- -- -- - ----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
i Gj100
For Otfice use Only
FOR BUILDING PERMIT DATE ` TRCC REG
CITY OF COLLEGE STATION
1101 TEXAS AVENUE APPLICATION # GIQ Au?`2
COLLEGE STATION, TX 77840 TEMP POLE # ` [ ✓
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Plmning&Development Services www.CSTX.GOV
ADDRESS/LOCATION: O CQF_STEp DINT 4N
LOT S V BLOCK g SUBDIVISION W 1=S`f FI F1-D ail t—LA 'U� ✓ SEC/PH BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Single Family
Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL
OR DESIGN REVIEW COMMITTEE APPROVAL: �A
TEXAS ACCESSIBILITY STANDARD (TAS
ROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ -I `fig 3 �}
TOTAL AREA: (58Q
HEATED AREA: 1149
(Cost of Labor and Materials)
�X PUBLIC SEWER
NUMBER OF BEDROOMS:
3
�Z.
❑ SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
�X SEWER TAP: 4"
INTERIOR WALL TYPE:
Sheet Rock
SIZE
X WATER TAP: %4"
EXTERIOR WALL TYPE:
Siding and/Or Masonry
SIZE
❑ OTHER TAP:
FOUNDATION TYPE:
Slab on Grade
SIZE
TEMP POLE
ROOF TYPE:
Composition
GARAGE TYPE: SINGLE F7
DOUBLE F—] TRIPLE
`A
ATTACHED FX
DETACHED F__] CARPORT
SIGNATURE OF APPLICANT: For St lecraft
*If proposed work involves new commercial construction or faibde improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
T#3 3-- 3d --o6
GPlans Examiner
A44 4 014
EMI, BOA_�%5
Zoning Official
ments:
YT r NO
Energy Code Compliance Information
% Glazing of exterior walls I I %
Insulation R value of exterior walls
R13 --'
Insulation R value of ceiling 1 (flat areas)
R30 e"
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40
Glazing U-Factor
.65
R value of ductwork
R6
A/C SEER Rating
13
PLAWREVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d' Development Services
PLAN REVIEW/PERMIT NUMBER#
(p
DATE: 3 l3 to
BUILDING ADDRESS:
909 Poeft,�c
I. Foundation Requirements
NA/ K
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
,4
CITY OF COLLEGE STATION
Planning 6 Development Services
P LAN REVI EW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NAT,
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
tj
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
Al A
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6 Development Services
V. Electrical Service Requirements
NAITO
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
G4
Street Ordinance Requirements
NA/0-0
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
VOK
Does not block any water course or divert any flow
Elevation certificate if required
PA
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
Comments:
r
PLANS EXAMINER
- 3y-O�,
DATE
Permit Number
REScheck Compliance Certificate Checked By/Date
2003 IECC
REScheck Software Version 3.6 Release 2
Data filename: S:\ACAD\Archived\Old REScheck\1 149C909 Crested Point.rck
PROJECT TITLE: Plan # 1149C-WV
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.14
DATE: 03/28/06
DATE OF PLANS: 03-28-2006
PROJECT DESCRIPTION:
SPEC
909 Crested Point
College Station, Texas
DESIGNER/CONTRACTOR:
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
COMPLIANCE: Passes
Maximum UA = 521
Your Home UA_ = 440
15.5% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Door 1: Solid
Door 2: Glass
SHGC: 0.40
Floor 1: Slab-On-Grade:Unheated
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R Value
U--Factor
�L
845
30.0
0.0
30
294
19.0
0.0
15
1186
13.0
0.0
81
132
0.650
86
38
0.500
19
33
0.580
19
182
0.0
190
Insulation depth: 0.0'
Air Conditioner 2: Electric Central Air, 12 SEER
Furnace 2: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Date
Builder/Designer �_�, 0 �n,�h 11
Area Calculator:
Description
'mom
,.,
-
o�■�■
. „
. „
®
, . ,
�
Window Area Total: 132.00
03/28/06 14:32:55 1 /1
Area Calculator:
.:..
...Assembly
Type
=01MIMMEMM
.' : .
Opaque door solid
masonite
we MI,
MKIT
M11
Door Area Total: 71.11
03/28/06 14:32:56 1 /1
Area Calculator:
Assembly Type
Comments/Description
Ceiling Area Total: 1139.00
03/28/06 14:32:56 1 /1
Area Calculator:
Assembly Type
Comments/Description
®■�■��
®■�■��
®■�■��
91■�■��
®■�■��
0■�■��
Exterior Wall Area Total: 1186.67
03/28/06 14:32:56 1 /1
Area Calculator:
M
Assembly Type
..
MOMI,■�■
®
�■�■moo
Floor Area Total: 0.00
03/28/06 14:32:56 1 /1