Loading...
HomeMy WebLinkAboutRES2006-00930, 06-934� • y30 R752113 10% 19M CITY OF COLLEGE STATION Planning & Development. Services 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: 08-18-06 # of pages including cover:4 If you did not receive a complete fax, please call our office immediately for a new transmittal. TO: GAYLINN FAX: COMPANY: RE: FROM: Gina Southerland 866-573-4352 COMPANY: City of College Station REMARKS: ❑ Urgent ❑ For your review ❑ Reply ASAP ❑ FYI City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor Application number Description of Work Construction type . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . 8/17/06 184200-2402-0580 2328 KENDAL GREEN CIR COLLEGE STATION TX 77845 CASTLEGATE SEC 4 PH 2 CASTLEGATE SEC 4, PHS 2, BLOCK 2, LOT 58 PLANNED DEVL HOUSING GREENS PRAIRIE INVESTORS LTD H&E CONTRACTING 979 589-1412 06-00000930 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Biolding Of f icial VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE . COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000930 Date 4/04/06 Property Address . . . . . . 2328 KENDAL GREEN CIR Property ID . . . . . . . . . 184200-2402-0580 R # . . . . . . . . . . . . . R110965 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 4 PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 121506 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD H&E CONTRACTING 4490 CASTLEGATE DR PO BOX 8742 COLLEGE STATION TX 778453388 2097 N FM 2038 BRYAN TX 77805 (979) 589-1412 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID PAID FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1841.00 INTERIOR WALL TYPE GYPSUM NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 526.00 Plan Check Fee .00 Issue Date . . . . 4/04/06 Valuation . . . . 121506 Expiration Date . . 10/01/06 Qty Unit Charge Per Extension BASE FEE 460.00 22.00 3.0000 THOU BLDG, VAL 100001-500000 66.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ----------6 ; BUILDING DEPT REP SEN A. --------- APPLICAN . �� Inspection Inquiry - City of College Station go qa!�DO Inspection Request Continents 0--0- -6- —1- K -2- -5- -:- -3- -9- - P -M --- --- q-1--s-out--h---- Support Emai E j Help PREPARED 8/08/06, 7:54:18 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/08/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 2328 KENDAL GREEN CIR SUBDIV: CASTLEGATE SEC 4 PH 2 CONTRACTOR H&E CONTRACTING PHONE (979) 589-1412 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-2402-0580 APPL NUMBER: 06-00000930 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/07/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 4/07/06 AP April 6, 2006 9:53:06 AM kwolfe early AM Strings On Setbacks O.K. Slab Ground Installed B115 01 5/16/06 OC BLDG, FRAMING TIME: 17:00 5/16/06 CA May 9, 2006 11:29:11 AM bkorthauer µ6/02/06 Not Ready For Inspection B115102 RH BLDG, FRAMING TIME: 17:00 s 6/02/06 AE June 2, 2006 7:59:36 AM kwolfe 06/02/2006 11:36 AM RH PDA Add bolt and brace in front bedroom. Add joist hanger to right of fireplace before insulation inspection. B130 01 6/09/06 JGM BLDG, INSULATION TIME: 17:00 6/09/06 DP June 8, 2006 1:37:00 PM bkorthauer 06/09/2006 12:25 PM JGM PDA need proper header and cripple where fireplace use to be B130 02 6/12/06 JGM BLDG, INSULATION TIME: 17:00 6/12/06 AP June 12, 2006 8:00:10 AM kwolfe B125 01 8/07/06 OC BLDG, FINAL TIME: 17:00 8/07/06 CA August 7, 2006 8:00:24 AM kwolfe Not Ready For Inspection B125 02 /08 06 BLDG, FINAL TIME: 17:00 $ Ai August 7, 2006 12:25:39 PM glsouth -------------------------------------- COMMENTS AND NOTES--------- � WF0762489 / 001 City of College Station PAGE 1 REQ. DATE: 04/24/06 04/24/06 12:06:32 LOCATION: 2328 KENDAL GREEN CIR LOC ID: 192798 REQUESTOR: H & E CONTRACTING ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/24/06 SCHED COMPLETION: 04/24/06 ******************************************************************************** JOB ORDER RESULT COMMENTS blP • q 3ro WF0757569 / 001 City of College Station PAGE 1 REQ. DATE: 04/04/06 04/04/06 12:28:11 LOCATION: 2328 KENDAL GREEN CIR LOC ID: 192798 REQUESTOR: H&E CONTRACTING ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/04/06 SCHED COMPLETION: 04/04/06 ******************************************************************************** JOB ORDER RESULT CONIlK NTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AYE ..,,. _j COLLEGE STATION, TX 73840 PHONE: (979) 764-3570 FAX: y (979) 764-3496 Application Number . . . . . 06-00000930 Page 2 Date 4/04/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE --- ----- ---------------- - --------- BUILDING DEPT REPRESENTATIVE: APPLICANT: -.-------- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE I COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000930 Page 3 Date 4/04/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF,DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN - BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AYE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000930 Date 4/04/06 ----------------------------------------------------=----------------------- Special Notes and Comments PRIVATE GARAGES Narrow Wall bracing Fully Sheathed with APA garage framing and interior anchors and bracing at front and rear door areas. Also Engineered Panel between Dining area and back door wall. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 526.00 526.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1276.00 1276.00 .00 .00 a ------------------------------- ---- --- -------------------- BUILDING DEPT REPRESENTATIVE: /1_ / - APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000934 Date 4/04/06 Property Address . . . . . . 2328 KENDAL GREEN CIR Property ID . . 184200-2402-0580 R # . . . . • • • • . . . . . R110965 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 4 PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD H&E CONTRACTING 4490 CASTLEGATE DR PO BOX 8742 COLLEGE STATION TX 778453388 2097 N FM 2038 BRYAN TX 77805 (979) 589-1412 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 4/04/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------- Fee summary Charged • ------------------------ Paid Credited -------------------- Due ---------- --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: Use APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 -�- (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION A,,A, CSTX GOV APPLICATION # l( U —C-1 3® TEMP POLE # Planningc¢DcvdopmenFSe ica (/ ADDRESS/LOCATION:, )S��{,J��q L (�' /'�Z��y✓ G�2 '�� LOT JOCK Z /SUBDIVISION SEC/PH 7 �- e.- I L- BUSINESS/OWNER NAME: �L� l)L� PHONE: S% V—U 3 % CONTRACTOWHOMEOWNER: / �c� ytJS 2�r%/� PHONE: CONTRACTOR ADDRESS: 7- ELECTRICIAN: HVAC: 7 Af l'—__h., 20 3 PLUMBER: _ GOOD CENTS (Residential only): CLASS OF WORK '-)I -A a? ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) EW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: 5//V� HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD" (TAS) PROJECT REG�IS-TRATION# EABPRJ VALUATION: $_. � -- )_1, VPTOTAL AREA( HEATED AREA: (Cost of abor and Materials) ❑ PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: S E El -WATER TAP: SIZE OTHER TAP: NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE EXTERIOR WALL TYPE FOUNDATION TYPE R alit MEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE [1/TRIPLE a ATTACHED Fj_� DETACHED a CARPORT SIGNATURE OF APPLICANT: "If proposed work involves new o ercial constru tion or facade i�rove`ments/7renovations o an existing commercial property, building elevations are required. Official Use Only �/� 3-29. o� Plans Examiner Zoning Official ents: YES NO (5&4tyx I S jt„ ffo'4) /#"e I Fire Marshall !!A.-) Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) .3 , Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC v Glazing U-Factor • 7 5- / R value of ductwork A/C SEER Rating / CITY OF COLLEGE STATION Planning er Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# 0& _ 9 3 p DATE: 3 Izgl ab BUILDING ADDRESS: a -Jg c.- I. Foundation Requirements N K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N K A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. N. Span exceeding code tables must be engineered Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS "'M II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N OK 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" MIT S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements A/ K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal CITY OF COLLEGE STATION Planning 6- Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements N K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location Vl. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VI1. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N K Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning cr Development Services Comments: ALL LANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS DATE