Loading...
HomeMy WebLinkAboutCNEW2006-00926W., DO • q2o -I I 1 R752 U9 10% P4 Date. ' 4 Permit # d(r — Project Name t� 175 Tws NC `D . COMMERCIAL CO Planning (Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Molly Hitchcock, Trey Fletcher) Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services (Eaphrame Thomas, James Boykin, Pete Garcia) Fire Department (Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith) Drainage L (Donnie Willis) Public Works - Sanitation (Wally Urrutia) Electrical Services (Tony Michalsky) Miscellaneous Notes PREPARED 9/22/06, 11:59:38 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/22/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 1905 TEXAS AVE S SUBDIV: WOLF PEN PLAZA TENANT, NBR: CICI'S PIZZA CONTRACTOR CODA CONSTRUCTION PHONE (972) 635-6086 OWNER NNN WOLF PEN PLAZA LLC ETAL PHONE PARCEL 668480-0000-0030 APPL NUMBER: 06-00000926 COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/S COMPLETED RESULT RESULTS/COMMENTS ----- ------------------------------------------------------------------------------------------ B115 01 6/15/06 JGM BLDG, FRAMING TIME: 17:00 6/15/06 AP June 14, 2006 12:57:03 PM bkorthauer B125 01 2/0 BLDG, FINAL TIME: 17:00 �rember 22, 2006 9:16:23 AM ncochran ----------- 2 -------------------------- COMMENTS AND NOTES-------------------------------------- �j WF0783364 / 001 City of College Station PAGE 1 REQ. DATE: 06/02/06 06/02/06 15:15:57 LOCATION: 1905 TEXAS AVE S LOC ID: 145194 EXT. ADDR.: FUTURE CICI'S PIZZA. REF NBR: ^ REQUESTOR: RICK VILLAREALL ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT 6" SWR 1 1/2" WTR TASK: SET UP NEW UTILITY ACCT SET READY " SCHED START: 06/02/06 SCHED COMPLETION: 06/02/06 ******************************************************************************** JOB ORDER RESULT COMIENTS 01.E - `'I 1-0 I_���M �-o C���'f co0.5T 6-55; �? - 0 C� City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 11/22/06 Parcel Number . . . . . 668480-0000-0030 Property Address . . . 1905 TEXAS AVE S COLLEGE STATION TX 77840 Subdivision Name . . . WOLF PEN PLAZA Legal Description . . . WOLF PEN PLAZA, LOT 3, ACRES 1 5.0416 Property Zoning . . . . GENERAL COMMERCIAL Contractor . . . . . . CODA CONSTRUCTION 972 635-6086 Application number 06-00000926 000 000 Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . ASSEMBLY (IBC) Flood Zone . . . . . . Approved . . . . . . . A'� Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL GUESTCHECIC FA 511 GuEsCMac' wwwmaaonalcneclan&com Date I Amount I Guests 1628323 ,rr 1 2 3 4 5 6 7 8 9 } 10 11 12 13 14 15 16 17 Transfer to front Total CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET /7 Date: No V. , -006 # of pages including cover: Z Ifyou did not mmi a complete fax, please call our office immediatelffor a new transmittal. TO: R c k FAX: 7 7 6` l g 7/ COMPANY' C : 6, 's P, RE' Tew /JVeat FROM' a ✓! cc % .-� M c Gu r-t COMPANY: City of College Station, Development Services REMARKS: ❑ Urgent ❑ For your review ❑ Repl v ASAP FYI TRANSMISSION VERIFICATION REPORT TIME 11/17/2006 16:38 NAME FAX TEL SER.# 000L5J596800 DATEJIME 11/17 16:37 FAX NO./NAME 97761871 DURATION 00:00:32 PAGE(S) 02 RESULT OK MODE STANDARD ECM CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, FO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: 1Uv 1,A06 # of pages including cover: 2- Myou did Trot twelvea complem fax, please call our ofii w =mcdiately fors now transmittal. TO: R f G k FAX: r 7 l COMPAW: e� - 6 r 'S RE: FROM _evti i Gc .»-1 % ►� c r �v City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . 9/22/06 Expiration Date . . . . 11/17/06 Parcel Number . . . . . 668480-0000-0030 Property Address . . . 1905 TEXAS AVE S COLLEGE STATION TX 77840 Subdivision Name . . . WOLF PEN PLAZA Legal Description . . . WOLF PEN PLAZA, LOT 3, ACRES 1 5.0416 Property Zoning . . . . GENERAL COMMERCIAL Owner . . . . . . . . . NNN WOLF PEN PLAZA LLC ETAL Contractor . . . . . . CODA CONSTRUCTION 972 635-6086 Application number 06-00000926 000 000 Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . ASSEMBLY (IBC) Flood Zone Special conditions 7> r NEED TO SOD DIRT AREA BY DRIVE-THRU. or 2.TAKE OUT THE STRIPING WHERE PARKING USED TO BE, BUT IS NOW DRIVE-THRU LANE. REMOVE COMMERCIAL DUMPSTER. Y.REMOVE PORTABLE STORAGE CONTAINER. FINISH FACADE WORK (IE: TRIMMING OUT DOORS, ETC.) 0 PAINT OR FINISH BOLLARDS. REMOVE ALL CONSTRUCTION DEBRIS AND DIRT FROM THE SITE. GENERAL SITE CLEAN UP (THERE IS A LOT OF TRASH ON SITE. FINISH SIGN WORK FOR MENU BOARD -MAKE SITE SOMEWHAT CCESSIBLE. - > NEED TO FINISH 2ND PUBLIC ENTRY DOOR AND TURN IN SHOPPING CENTER SIGN PLAN OR REMOVE EXCESS SIGNAGE. 11.DUMPSTER ANGLE ISSUES NEED TO BE RECONCILED (SITE PLAN MUST BE SUBMITTED AND APPROVED). Needs cahin and lock on outside post indicator value (fire sprinkler) -----Needs lockout for the Fire Alarm Circuit breaker Approved . . . . . . . Building O Lcial VOID UNLESS SIGNED BY BUILDING OFFICIAL CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: Dcj . 3 # of pages including cover: Z- Jfyou drd not t�ceive a complete fax, please call our office immediately for a new transmittal. TO: Mr. -C ,'c K ✓ FAX: COMPANY. 61 RE: —Fe mrJOrotry C O Ct-7 COMPANY:_ City of College Station, Development Services REMARKS: ❑ Urgent ❑ For your review ❑ Rep] y ASAP 9m TRANSMISSION VERIFICATION REPORT TIME 10/30/2006 11:29 NAME FAX TEL SER.0 000L5J596800 DATE DIME 10/30 11:29 FAX NO./NAME 97761871 DURATION 00: 00: 33 PAGE(S) 02 RESULT OK MODE STANDARD ECM QTY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979,764.8496 FACSIMILE COVER SHEET Date: t%-f . 104 o r # of pages including cover:� If yrau did not mmi ve a complete fxx, pl se cell our officv immc&,etely fvr a new iransmxt`ia1 TO: 14 Ic {% FAX: -? � & COMPANY. ef RE: a FROM: ! cv� a .•h COMPANY:_ Citv of College Sfafinn City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . 9/22/06 Expiration Date . . . . 11/30/06 Parcel Number . . . . . 668480-0000-0030 Property Address . . . 1905 TEXAS AVE S COLLEGE STATION TX 77840 Subdivision Name . . . WOLF PEN PLAZA Legal Description . . . WOLF PEN PLAZA, LOT 3, ACRES 1 5.0416 Property Zoning GENERAL COMMERCIAL Owner . . . . . . . . . NNN WOLF PEN PLAZA LLC ETAL Contractor . . . . . . CODA CONSTRUCTION 972 635-6086 Application number 06-00000926 000 000 Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type ASSEMBLY (IBC) Flood Zone Special conditions NEED TO SOD DIRT AREA BY DRIVE-THRU. 'C TAKE OUT THE STRIPING WHERE PARKING USED TO BE, BUT IS NOW DRIVE-THRU LANE. REMOVE ALL CONSTRUCTION DEBRIS AND DIRT FROM THE SITE. *.GENERAL SITE CLEAN UP (THERE IS A LOT OF TRASH ON SITE. ,,FINISH SIGN WORK FOR MENU BOARD -MAKE SITE SOMEWHAT ACCESSIBLE. NEED TO FINISH 2ND PUBLIC ENTRY DOOR AND TURN IN SHOPPING CENTER SIGN PLAN OR REMOVE EXCESS SIGNAGE. ,�.DUMPSTER ANGLE ISSUES NEED TO BE RECONCILED (SITE PLAN MUST BE SUBMITTED AND APPROVED). FINISH FACADE WORK (IE: TRIMMING OUT DOORS, ETC.) y,Needs lockout for the Fire Alarm Circuit breaker Approved . . . . . . . VOID UNLESS SIGNED BY BUILDING OFFICIAL City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . Expiration Date . . . . Parcel Number Property Address Subdivision Name . . . Legal Description . . . Property Zoning 9/22/06 10/27/06 668480-0000-0030 1905 TEXAS AVE S COLLEGE STATION TX 77840 WOLF PEN PLAZA WOLF PEN PLAZA, LOT 3, ACRES 1 5.0416 GENERAL COMMERCIAL Owner . . . . . . . . . NNN WOLF PEN PLAZA LLC ETAL Contractor . . . . . . CODA CONSTRUCTION 972 635-6086 Application number 06-00000926 000 000 Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . ASSEMBLY (IBC) Flood Zone Special conditions 1.NEED TO SOD DIRT AREA BY DRIVE-THRU. 2.TAKE OUT THE STRIPING WHERE PARKING USED TO BE, BUT IS NOW DRIVE-THRU LANE. 3.REMOVE COMMERCIAL DUMPSTER. 4.REMOVE PORTABLE STORAGE CONTAINER. 5.FINISH FACADE WORK (IE: TRIMMING OUT DOORS, ETC.) 6.PAINT OR FINISH BOLLARDS. 7.REMOVE ALL CONSTRUCTION DEBRIS AND DIRT FROM THE SITE. 8.GENERAL SITE CLEAN UP,(THERE IS A LOT OF TRASH ON SITE. 10.FINISH SIGN WORK FOR MENU BOARD -MAKE SITE SOMEWHAT UNACCESSIBLE. 11.NEED TO FINISH 2ND PUBLIC ENTRY DOOR AND TURN IN SHOPPING CENTER SIGN PLAN OR REMOVE EXCESS SIGNAGE. 12.DUMPSTER ANGLE ISSUES NEED TO BE RECONCILED (SITE PLAN MUST BE SUBMITTED AND APPROVED). Needs cabin and lock on outside post indicator value (fire sprinkler) Needs lockout for the Fire Alarm Circuit breaker TT o o r7 o L o t * / ,-�\ � .. r 1_: �c►v L..-. Approved . . Buflding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . 9/22/06 Expiration Date . . . . 10/13/06 Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . 668480-0000-0030 1905 TEXAS AVE S COLLEGE STATION TX 77840 WOLF PEN PLAZA WOLF PEN PLAZA, LOT 3, ACRES 1 5.0416 GENERAL COMMERCIAL Owner . . . . . . . . . NNN WOLF PEN PLAZA LLC ETAL Contractor . . . . . . CODA CONSTRUCTION 972 635-6086 Application number 06-00000926 000 000 Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . ASSEMBLY (IBC) Flood Zone . . . . . . Special conditions . . 1.NEED TO SOD DIRT AREA BY DRIVE-THRU. 2.TAKE OUT THE STRIPING WHERE PARKING USED TO BE, BUT IS NOW DRIVE-THRU LANE. 3.REMOVE COMMERCIAL DUMPSTER. 4.REMOVE PORTABLE STORAGE CONTAINER. 5.FINISH FACADE WORK (IE: TRIMMING OUT DOORS, ETC.) 6.PAINT OR FINISH BOLLARDS. 7.REMOVE ALL CONSTRUCTION DEBRIS AND DIRT FROM THE SITE. 8.GENERAL SITE CLEAN UP (THERE IS A LOT OF TRASH ON SITE. 9.FINISH INSTALLING HANDICAPPED PARKING SIGNS. 10.FINISH SIGN WORK FOR MENU BOARD -MAKE SITE SOMEWHAT UNACCESSIBLE. 11.NEED TO FINISH 2ND PUBLIC ENTRY DOOR AND TURN IN SHOPPING CENTER SIGN PLAN OR REMOVE EXCESS SIGNAGE. 12.DUMPSTER ANGLE ISSUES NEED TO BE RECONCILED (SITE PLAN MUST BE SUBMITTED AND APPROVED). Needs cahin and lock on outside post indicator value (fire sprinkler) Needs lockout for the Fire Alarm Circuit breaker OK -Needs key(s) for knox_box Approved . . . . . . . Bufldinq Officia VOID UNLESS SIGNED BY BUILDING OFFICIAL City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . Expiration Date . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 9/22/06 9/29/06 668480-0000-0030 1905 TEXAS AVE S COLLEGE STATION TX 77840 WOLF PEN PLAZA WOLF PEN PLAZA, LOT 3, ACRES 1 5.0416 GENERAL COMMERCIAL Owner . . . . . . . . . NNN WOLF PEN PLAZA LLC ETAL Contractor . . . . . . CODA CONSTRUCTION 972 635-6086 Application number 06-00000926 000 000 Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . ASSEMBLY (IBC) Flood Zone . . . . . . Special conditions . . 1.NEED TO SOD DIRT AREA BY DRIVE-THRU. 2.TAKE OUT THE STRIPING WHERE PARKING USED TO BE, BUT IS NOW DRIVE-THRU LANE. 3.REMOVE COMMERCIAL DUMPSTER. 4.REMOVE PORTABLE STORAGE CONTAINER. 5.FINISH FACADE WORK (IE: TRIMMING OUT DOORS, ETC.) 6.PAINT OR FINISH BOLLARDS. 7.REMOVE ALL CONSTRUCTION DEBRIS AND DIRT FROM THE SITE. 8.GENERAL SITE CLEAN UP (THERE IS A LOT OF TRASH ON SITE. 9.FINISH INSTALLING HANDICAPPED PARKING SIGNS. 10.FINISH SIGN WORK FOR MENU BOARD -MAKE SITE SOMEWHAT UNACCESSIBLE. 11.NEED TO FINISH 2ND PUBLIC ENTRY DOOR AND TURN IN SHOPPING CENTER SIGN PLAN OR REMOVE EXCESS SIGNAGE. 12.DUMPSTER ANGLE ISSUES NEED TO BE RECONCILED (SITE PLAN MUST BE SUBMITTED AND APPROVED). Approved . . . . . . . uiiding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL G<✓y0t•.Vv- P.'3"OeHSor ram( L4 Q�� ba u Ben ar'in McCart - CiCi Pizza Page 1 From: Jerry Duffey To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Nicole Cochran Date: 9/25/2006 8:51:21 AM Subject: CiCi Pizza Temp CO for Ci Ci Pizza 1905 Texas Ave South needs chain and lock on outside Post indicator value (fire sprinkler) needs lockout for the Fire Alarm Circuit breaker needs key(s) for knox box Jerry Duffey '78 Deputy Fire Marshal College Station Fire Dept. 979-764-3400 979-764-3403 fax jduffey@cstx.gov Benjar?iin McCarty - Re: Calling for CO @ 1905 Texas Ave South - CiCi's Pizza Page 1 From: Jennifer Prochazka To: Alan Gibbs; Benjamin McCarty; Bob Mosley; Carol Cotter; Chris Haver; Crissy Hartl; Donnie Willis; Eaphrame Thomas; Eric Dotson; Eric Hurt; Gina Southerland; Grant Wencel; James Boykin; Jason Schubert; Jennifer Reeves; Jerry Duffey; Jerry Jones; John Logan; Josh Norton; Kim Wolfe; Lindsay Boyer; Molly Hitchcock; Nicole Cochran; Pete Garcia; Steve Smith; Tony Michalsky; Wally Urrutia Date: 9/22/2006 3:58:39 PM Subject: Re: Calling for CO @ 1905 Texas Ave South - CiCi's Pizza Planning inspected the site. It is not ready for CO. There are some issues that can be included on a temp CO, but overall the site is not ready for the public to use it. Here are a list of issues: --')-Need to sod dirt area by drive-thru -Take out the striping where parking used to be, but is now drive-thru lane -remove commercial dumpster -remove portable storage container -finish facade work (ie: trimming out doors, etc.) -Paint or finish bollards -remove all construction debris and dirt from the site -General site clean up (there is A LOT of trash on site) -Finish installing handicapped parking signs -finish sign work for menu board - make site somewhat unaccessible -Need to finish 2nd public entry door and turn in shopping center sign plan OR remove excess signage. -Dumpster angle issues need to be reconciled (site plan must be submitted and approved) >>> Nicole Cochran 9/22/2006 1:24 PM >>> Are there any issues? BP# 06-926 L Thanks!! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov CC: Lance Simms •� Water isLife Forward This Original Report PowerlsProgress Upon completion to: Public Utilities Department ,MCefSPllde Backflow Prevention ` P.O. Boa 9960 e • • - College Station, Texas 77842 —^'^' Cw d System ID: 0210002 Backflow Prevention Assemblv Test and Maintenance Resort e . Ille 'ble or incomplete reports will not be accepted "$ackt'low Assembly Information Please Print ber: 3 87 a'7 Manufacturer: vt 4 5 Model: �� ize: " eAssembly: ❑ RPZ E3 DCA ❑ PVB ❑ RPZ-D ❑ DC 5i ❑ SRPVB Res' u mess Name: C i C �_i C' % Z Z z zN- y al Address: D S %^X k ✓� 5 W, As bly , ocation on the property: `� v e � .� � — irrigation: ReauMkp assembly is inst d: Fireline: ❑ Domestic: 0 Is t ti as mhly instal accordance with manufacturer No reco%rfendations anr local codes: Reduc Pt, sure Backflow Prevention Assembly. �Pres�siue Vacuum' Breaker, Inil Test �� _ • Y ' _ ' Double- e Valve Assembly ls` Cbsck 4 2nd Check re Relief Valve ; ; Check Valve r,,; it;nlet'.•' Held at Held at -2, 0 i`'"" : !ten d at pened at Held at l PSID PSID `lq-_PSID—.- -�— PSID PSID Closed Tight Closed Ti gh of Open r' - Did Not Open Leaked Leaked Leaked d ❑ ❑ ❑ Repai and matarial,w Agri Held at Held at _— PSID PSID Opened at Opened at Held at A eer irs . Closed ttClosed Tight ❑ --PSI —_PSI —PSI e; a_ ow prevention assembly listed sbeen tested and in ,by TNRCC Regulations and i errto be le CTYes ❑ No ing within acceptable parameters. �I ce�rtilythat all information on tills report is true and correct at the time of testing. Gauge Calibration Date: 0 5 : ' Gauge Model: e,0 i e a.# , . sS�i 1� .„.. CertificationP 7 Y y Date /Z `(2 - O v Firm Name: Bach Low NeeleFirm Address: � y 37'�rvZTk -1�g 7 �- Teciliucian: q PLEASE PRINT Firm Phone Number. V(,3 G - YVJ i Date: I/ ? / 0 % Signature: Nlcole Cochran Re Calling for CO @ 1905 Texas Ave South CiCI's Pizza 1 From: Tony Michalsky To: Nicole Cochran Date: 9/22/2006 1:45 pm Subject: Re: Calling for CO @ 1905 Texas Ave South - CiCi's Pizza okay with us >>> Nicole Cochran 9/22/2006 1:24 PM >>> Are there any issues? BP# 06-926 Thanks!! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov Nicole Cochran Re. Calling for CO @ 1905 Texas Ave South CiCi's Pizza 1 From: To: Date: Subject: OK with Drainage. Donnie Willis Cochran, Nicole 9/22/2006 1:38 pm Re: Calling for CO @ Donnie Willis, CFM Environmental Engineering Technician Certified Floodplain Manager Public Works Department 979-764-6375 office 979-229-7632 cell dwillis@cstx.gov 1905 Texas Ave South - CiCi's Pizza >>> Nicole Cochran 09/22/06 1:24 PM >>> Are there any issues? BP# 06-926 Thanks!! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov BUILDING PERMIT CITY OF COLLEGE STATION •1101.TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 --------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00000926 Date 5/08/06 1905 TEXAS AVE S 668480-0000-0030 R106622 CICI'S PIZZA COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION WOLF PEN PLAZA MERCANTILE GENERAL COMMERCIAL 200000 Owner Contractor NNN WOLF PEN PLAZA LLC ETAL CODA CONSTRUCTION % TAX DEPARTMENT 129 EAST MAIN ST PO BOX 441069 ROYSE CITY TX 75189 800441069 (972) 635-6086 --- Structure Information 000 000 RESTAURANT TENANT FINISHOUT Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . ASSEMBLY (IBC) Other struct info . . . . . EXTERIOR WALL TYPE CONCRETE IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 6195.00 INTERIOR WALL TYPE SHEET ROCK SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc GS Permit Fee 760.00 Plan Check Fee .00 Issue Date . . . . 5/08/06 Valuation . . . . 200000 Expiration Date . . 11/04/06 Qty Unit Charge Per Extension BASE FEE 460.00 100.00 3.0000 THOU BLDG, VAL 100001-500000 300.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED BUILDING DEPT REPRESENTATIVE;, APPLICANT t` f� 3r BUILDING PERMIT 4.'` CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000926 Page 2 Date 5/08/06 Special Notes and Comments TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 ELETRIC UTILITIES COMMENTS DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS (IF NECESSARY) DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE (IF NECESSARY) DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE. CITY INSTALLS REMAINING 201. DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE AS INSTALLED FOR ELECTRIC LINES. DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14 VERSION. EMAIL TO RBOLIN@CI.COLLEGE-STATION.TX.US DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE FROM TRANSFORMER TO BUILDING FOR QUESTIONS CONTACT RONNIE BOLIN AT 979-764-3614 PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Electrical conduit installation shall be installed per city specs and is the responsibility of the owner and/or contractor. Contact the electrical division at (979) 764- 6314 for more information. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) PROVIDE MINIMUM 42" CLEARANCE FROM CENTER OF WATER CLOSET TO EDGE OF LAVATORY INTERIOR FINISH MATERIAL SHALL HAVE A CLASS A RATING PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT All outdoor lighting must be in compliance with Section 7.10, Outdoor lighting Standards of the City's Unified BUILDING APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION ,1101,TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000926 Page 3 Date 5/08/06 Special Notes and Comments Development Ordinance All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-way or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER CONDUIT FROM THE TRANSFORMER. (see site plan for location of conduit or contact electrical division) CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) PROVIDE PANIC HARDWARE ON EXIT DOORS If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI AS PER THE ZONING ORDINANCE SECTION 12.3.L; ATTACHED SIGNS SHALL NOT EXTEND MORE THAN ONE FOOT AWAY FROM EXTERIOR BUILDING FACE ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR @ (512) 463-3211 FOR MORE INFORMATION TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK —� ALL WOLF PEN PLAZA TRASH DUMPSTER ENCLOSURES MUST BE BUILDING L APPLICANT: BUILDING PERMIT < CITY OF COLLEGE STATION -1101,TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000926 Date 5/08/06 ---------------------------------------------------------------------------- Special Notes and Comments CORRECTED BEFORE A C.O. WILL BE ISSUED. TYPE I COMMERCIAL KITCHEN EXHAUST HOOD IS REQUIRED. NON-COMBUSTIBLE CONSTRUCTION WITHIN 18" OF TYPE I EXHAUST HOOD, INCLUDING BUT NOT LIMITED TO WALL STUDS, WALL FINISH MATERIALS, JOISTS, RAFTERS, AND CEILING MATERIALS. SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total Plan Check Total Grand Total 760.00 760.00 .00 .00 760.00 760.00 BUILDING DEPT RF$RUENTAT APPLICANT: .00 .00 .00 .00 .00 .00 -- -- ---- - - - - C-v ­ "03/i9/2096 15:-56 9797643496 COM DEVELOPMENT SER'' PAGE. 02/02 APPLICATION FOR.BUILDING PERMIT C" OF COLUGE'surom 1101 TEXAS AVENUE COLIEdE $_fATIU14 JA 77mo CIT1l0F (979)4644570,'(979)764.3496 AL-i-Ah-Am, PAX www., ps,T, ADDRESS/LOCATION; C LOT BLOCK Su-aDW10N SEC/PH DIUSINEMOVVNSR NAME. Rick Villareal PH00.1 979/823-9100 CONTRACTOFJKOMEOVVNER: Coda Construction, Inc. PHOW'." 9721635-6086 CONTRACTOR ADDRESS;.. 129-East Main Street,.Rouse-.City -Texas 7518Q9 ELECTRICLAN: Oz Electrical PLUMBER: A-1 Plumbing WAC: GOOD CENTS Aesklentlal.only): CLASS OF WORK -ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION 'MOVING SHELL ONLY DEMOLITION (Mlmlos-Survey) 7' NEW; CONSTRUCTION SLAB ONLY DUPLEX (Landecape Plarm , 1 ­7 - i nCMODE-URENOVATION" SMMM[Nb POOL, Required), DESCRIPTION OF WORK: Interior Finish Out' STRUCTURE USE:, Restaurant HOMEOWNER'ASSOCIATIoN/ARciirrEcTuAL OR DESIGN REVIEW COMMITTEE PR VAL: TEXASAGGESSIBILITY STANDARD (TAS) PROJECT REGismnow EAoPRJ 21 - 1 __� - VALUATION. i ODD. 00 TOTAL AREACLLtAS HEATED AREA; (Cost of Labor and Materials) FiLisucteAER WwER of SmRooms: n(00,00 El SEPTICrrREATMEWT SYSTEM NumBEFt of BATHRooms: 2 SEVVER TAP: ImmoRWALLTYPE: Metal Stud/Gypsum SIZE EIWATER TAP: OTHER -TAP. PTEmp PoLE ' GARAGE TYPE., Sim ... §9E SINGLE Mi ATTACHED EXTERIOR WALL TYPE: � -Existing -Concrete Tilt Wall Fotm=om Type - ROOF TYPE: DOUBLE DETACHED Ej — Existing.Concrete Existing E-1 SIGNATURE OPAPPLICANT, =Po work invcdves new commercial constrUWm -M&RWUMNWWFentsfmwvations to an existercial propW,:6�jljding elevations are required. Official We Only vep-, — , 7LI, aES br NO ns Exam Zon'ino Official APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W WW.CSTX.GOV ADDRESS/LOCATION: Lot 'Block Subdivision Sec/Ph BUSINESS/OWNER NAME: IG 1 3 PI CONTRACTOR/HOMEOWNER: 0 (11" 1_0 a I LD CONTRACTOR ADDRESS: t ` ' ` t. Phone: i7q- G 91-Z¢24 Phone: ELECTRICIAN: ' ' PLUMBER: o (-t- -rn 'Goo HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION" SWIMMING POOL DESCRIPTION OF WORK: V419 fit 4 [ S C, zTr�,4 Pi"-T" STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ Z voi �`a TOTAL AREA: �o� 2S��r HEATED AREA: S/l- (Cost of Labor and Materials) 0 Public Sewer Septic/Treatment System 0 Sewer Tap: PK10&- Size [� Water Tap: &ISfi Nc- I. Vz Size Other Tap: Size Temp Pole /A Number of Bedrooms: Number of Bathrooms: Interior Wall Type: IMt 1" ST-105 Exterior Wall Type: s7 �,p,u l I�-��I"!s b u`t' k-tAI -1 Foundation Type: 1�� 'Cn.0 bit 64w?-2 - Roof Type: 010'& / (.Tr Ali. ►`Single I I Double I I Triple I I Attached n Detached n Carport n SIGNATURE OF APPLICANT: *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating PROJECT �� C'• S P'/ 3---'� PLAN REVIEW NO- D 6 — 2-- �, ASSEMBLY OCCUPANCY REQUIREMENTS 2000 International Building Code • A-1 ASSEMBLY • A-2 ASSEMBLY • A-3 ASSEMBLY • A-4 ASSEMBLY • A-5 ASSEMBLY • W/ • W/O A Stage Requiring Proscenium Opening Protection CODE SECTION ITEM O,K,, COMMENT OR N/A 303.1 Classification A-1/ �-7 A-3, A-4, A-5 C Table 503 Building Height & Area Q 504 Height modifications 506 Area Modifications fop/i �K�• ��( 507.2 Unlimited Area - One Story 1J` 507.8 Unlimited Area - Motion Picture Theaters 302.1.1 Incidental Use Areas A1111- Table 302.3.3 Mixed Occupancy Q fG 302.2 Accessory Use Areas O (- Table 302.3.3 Note d&e Separation Exemptions w 1007.5 Stage Means of Egress 1008.5.1 Egress Width Without Smoke Protection 1008.5.2 Egress Width With Smoke Protection 1008.1 Main Exit Fronts on a Public Place 1003.2.2 Design Occupant Load Z 3 p lC 1003.2.2.5 Occupancy Load Sign Table 1607.1 Design Loads (platforms & stages 410.3.1 Stage Construction 410.4 Platform Construction 410.5 Dressing and Accessory Rooms 410.3.7 Stage Ventilation 410.3.4 Proscenium Wall 410.3.5 Proscenium Curtains 2000 Plan Review Forms CODE SECTION ITEM O,K,, COMMENT OR N/A 410.3.2 Galleries, Gridirons, Catwalks, and Pinrails ov 410.3.3 Exterior Stage Doors 410.3.6 Combustibility of Scenery 409 Projection Rooms 410.7 Stage Standpipes 411 Special Amusement Buildings 411.3 Automatic Fire Detection 1008.1-1008.10 Grandstands and Bleachers 903.2.1 SPRINKLERS WHERE REQUIRED WA 903.2.12.1 Basement > 1500 sq It A / 410.6 Stages (Sprinklers) 1008.5.2.3 Smoke Protected Seating (Sprinklers) 411.4 Special Amusement Buildings (Sprinklers) 907.2.11 Special Amusement (Smoke Detection) Table 601 Note d Reduction of Hourly Ratings With Sprinklers 603.1 Combustible Materials in Type I and Type II Construction 907.2.1 Manual Fire Mann 907.2,13.2 Fire Alarms - Atrium Table 1004.2.4 Exit Access Travel Distance © C 903.3.1 Sprinkler Standard NFPA 13 )V 903.4 Sprinkler System Monitoring and Alarms ��- Table 803.4 Lobby Area Interior Finish {� Page 24 of 60 �OHZ! `v w��ANiM•^ Mean Your Files Day 2000 VDIP OPIR)MIM 'UNTO '1, � RI i 1 Lyn — fi ovr Fye s� m� U 0 recycling of work PROJECT PLAN REVIEW NO ASSEMBLY OCCUPANCY REQUIREMENTS 2000 International Building Code CODE ITEM O.K., SECTION COMMENT OR N/A 805.1 Decoration and Trim Q K 905.3 STANDARDS WHERE N/A REQUIRED 905.3.1 Buildings with floors > 30 ft above Fire Department Vehicle N VIA Access 905.3.2 Buildings with > 10,000 sq ft and > 200 ft travel to Fire Department Vehicle Access 905.3.5 Stages > 1000 sq ft 905.5.1 A-1 & A-2 with occupant load of more than 1000 persons 905.3.3 Nonsprinklered with occupant load exceeding 1000 persons 905.4-905.6 Hose Connection Location bg 905.2 Standpipe Standard NFPA 14 ®1� 905.9 Valves Controlling Water Supplies 905.7 Cabinets Chapter 10 Egress Requirements 1001 General 1003.2.3 Egress Width 1008.1 Capacity of Main Exit • Occupant Load 1008.2 Other Exits 1003.2.2.7 Converging Exits 1004 Travel Distance & Arrangement of Exits Table 1004.2.1 Two Exits (Room or Tenant Space > 50 Occupants or travel Q greater than 1004.2.5) 1004.2.5 Common Path of Travel • 75 ft L9 K 1004.2.2.1 Exit Separation ('/ D (C Diagonal Dimension of Building) 1005 Minimum Number of Exits 2000 Plan Review Forms CODE SECTION ITEM O.K., COMMENT OR N/A 1004.3.2.2 Minimum Width of Access Corridor �/� 1004.3.2.5 Exit Access Corridor Continuity Table 1005.2.2 Single Exit (One Story, 50 occupants, and 75 ft Travel Distance) A-11* Table 1003.2.3 Minimum Stair Width 1003.3.1.1 Minimum Exit Door Width (9 (( 714.2.3(3) Non -rated Doors In theaters 1007.1 Boiler, Incinerator or Furnace Rooms 1007.2 Refrigeration Machinery Rooms 1004.3.2.3 Dead End Corridor • 20 ft 1004.3.2 Exit Access Corridors 1005.3.2.5 Smokeproof Enclosures 1003.2.2.8 Mezzanines 1005.3.2 Enclosed Stairways 1008.4.1 Balcony Stairs 1005.3.6 EXTERIOR EXITWAY STAIRS 1005.3.6.1 Height • 6 stories • 75 ft 1004.2.4.2 Balcony Travel Distance Increase 1005.3.6.5 Separation Stairway Protection Building 1006.2.2 Adjacent Lot Line 1003.3.3 STAIRWAY CONSTRUCTION 1003.3.3.5 Stairway Construction 1003.3.3.3.2 Closed/Open Risers 1005.3.2.2 Separation of Closets Below Stairways 1005.3.2.3 Stairway Identification for Stairs That Continue Below the Level of Discharge Page 25 of 60 PROJECT PLAN REVIEW NO ASSEMBLY OCCUPANCY REQUIREMENTS 2000 International Building Code CODE SECTION ITEM O.K., COMMENT OR NIA 1003.3.3.3 Stair Treads and Risers FIA 1008.9.1 Aisle Treads 1008.9.2 Aisle Risers 1003.3.3.3.1 Uniform Treads & Risers 1003.3.3.7 Circular Stairs 1003.3.3.4 Landings 1003.3.3.11 Handrails 1003.3.3.2 Headroom 1003.3.3.12 Access to Roof tv 1005.3.2.1 Exit Stair Exterior Wail Requirements 1005.3.4 Exit Stair Openings 1005.3.5 Horizontal Exits 1005.3.6.2 Exterior Stairs Openness Requirements 1006 Exit Discharge Q L. 1006.3.1 Egress Courts P/ 1005.3.3 Exit Passageway 1003.3.1.9 Egress Doors and Hardware 1003.3.1.8 Latching and Locking Devices f f' 1003.3.4 Ramps 1003.2.12, 1008.12 Guards 1003.2.12.2 Guard Opening Limitations 1003.2.10 Exit Illumination & Exit Signs ®f!� 1004.3.1 Aisles Serving Seating at Tables 1008.10 Assembly Seats Stability 1008.11 Handrails • / 1008.12 Assembly Guards 1008.13 Bleacher Footboards 2000 Plan Review Forms CODE SECTION ITEM O.K., COMMENT OR WA 1008.3 Foyers and Lobbies (9(6 1008.4 Interior Balconies )VIA 1007.5 Special Exits from Stages 1007.4 Projection Rooms 1008.9 Assembly Aisle and Stair Construction 1008.7 Assembly Aisles and Seating 2702.2.1 Emergency Power OK 1107.2 Accessibility Features (e Page 26 of 60 PROJECT PLAN REVIEW NO ASSEMBLY OCCUPANCY REQUIREMENTS 2000 International Building Code INTERIOR FINISH INTERIOR FINISH SECTION 803.4 UNSPRINKLERED SPRINKLERED r REQUIRED REQUIRED ACTUAL O.K., REQUIRED REQUIRED ACTUAL O.K., A-1 & A-2 A-3, A-4, & A-5 COMMENT A-1 & A-2 A-3, A-4, & COMMENT OR NIA A-5 OR NIA Vertical Exits and A A B B Exit Passageways 1-0 Exit Access A • As B B Corridors and Other Exitways Rooms and Enclosed B. C C C Spaces' Floor Covering 0.22 watt/ 0.22 watt/ 0.22 watt/ 0.22 watt/ Corridors & Exits sq cm. sq cm. sq cm. sq cm. a. Lobby areas in A-1, A-2„ and A-3 occupancies shall not be less than Class B materials. b. Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and fireblocked as required by Section 803.3.1. C. In vertical exits of buildings less than three stories in height of other than Group 1-3, Class B Interior finish for unsprinklered buildings and Class C Interior finish for sprinklered buildings shall be permitted. d. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire -resistance rating is required for structural elements, the enclosing partitions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered enclosing spaces and the rooms or spaces on both sides shall be considered one. In determining the applicable requirements for rooms and enclosed spaces, the specific occupancy thereof shall be the governing factor regardless of the group classification of the building or structure. e. Class C interior finish materials shall be permitted in places of assembly with an occupant of 300 persons or less f. Applies when the vertical exits, exit passageways, exit access corridors or exilways, or rooms and spaces are protected by a sprinkler system installed in accordance with Section 903.3.1.1 or Section 903.3.1.2. 2000 Plan Review Forms Page 27 of 60 City of College Station Page of Building Inspection Department g PLANS EXAMINATION REPORT Address: 1 q 0T A✓e. Sck4t ► su,Ve l 90 S Date: A4Q"c-k - Project Name: 6 ; (! - 5 r " Z 7--0- W o /-F Je!�2 Al PIA z� Drawing Number Code Ref. Number Questions or Comments �K N" j9r FH C /OS a rG P st s-f 6e- C�O✓�tG�eol .D %o -7^ ..J- I"I Z o oq/ A/2 C e�u ✓a �r �� � f l � � �..`n /a �Y %Owe Co,1, h,4 s-4;ly e. Co✓I 5'f, O I e G o a— *" ; -' C_0,4 C ✓c7�� S1a%. O l ec Gj Coy,•, 1 ta.�c G� . ©0`3 S,Ei�- C— TD S c oyi ✓1vl1ecf ! im e4%Y rt o �v► S� Ll �.. fir,, _ T-71 !--0 C a -A �0" 21 (7 20 Received by: 3 t y Date: (! 76 S March 31, 2006 Application #: 06-926 Re: Ci Ci's Pizza- 1901 Texas Avenue South, Suite # 1905 A & B Dear, Mr. Dennis T. Mitchell I have completed the plan review for the above referenced project and have the following comments. The plan review is based on the 2003 International Codes, the 2002 National Electrical Code and our local amendments. Where appropriate, I have included the applicable code sections. 1. Wolf Pen Plaza has 5 dumpster enclosures that were built incorrectly, and the City of College Station have been trying to resolve this matter for several years. Ci Ci's Pizza is the last tenant in Wolf Pen Plaza, and to resolve this matter the City of College Station will hold the CO for Ci Ci's Pizza until the enclosures are corrected. 2. Provide exterior emergency exit discharge lighting with back-up power at all exterior exits to comply with section 1006.1 of the 2003 International Building Code. 3. Provide Type I exhaust hoods for both oven locations that comply with section 507.2.1 of the 2003 International Mechanical Code. 4. Provide non-combustible walls and ceiling materials construction within 18" of exhaust hoods type I to comply with sections 506.3.6 and0 506.5.4 of the 2003 International Mechanical Code. 5. Where panic hardware is not provided at exterior exit doors the following egress statement must be present on doors: "DOORS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." to comply with section 1008.1.8.3 of the 2003 International Building Code. 6. Provide main disconnect on the exterior of the building. 7. Need to provide fire sprinkler/ fire alarm plans for approval prior to installation. 8. If chemicals are used to soften water a backflow device will be required on the domestic water line. 9. Type K copper minimum under concrete slabs without joints or connections per City of College Station's Ordinance and Code Amendments. 10. Provide lighting and mechanical compliance certificates per 2003 IECC. 11. Provide a TAS # — Texas Accessibility Standards registration number. 12. Provide fire extinguisher locations. The review does not include any civil or zoning issues or NRA requirements of the Unified Development Ordinance. Please respond to the plan review comments at your convenience. Three sets of plans addressing these issues will be required. Should you have any questions, contact me at 979-764-3754. Thank You Benjamin McCarty Commercial Plans Examiner CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: M a c, In I I I .2-0 0 6 # of pages including cover: :2- If you did not receive a complete fax, please call our office immediately fora new transnutte.. TO: 1 ". j-, sue✓) COMPANY: FAX: q7Z- 393 - /(-123 RE: G,' C —"o LE 1"CH f �a - 120 t 1—, koc 5 l ,9 v S FROM: /3 c. A4o6" g-- COMPANY: Citv of College Station, Development Services REMARKS: ❑ Urgent [Z For your review ❑ Replay ASAP (1 FYI IP-. 43 ►r (fit4 j" Z a w+ 5 e "--c 5 Yp cam. Gt Go t-'-7 y o'F �Y ,% �QyI Y'et�� �e w l e fT"-e r �, ✓ C,' C ' ' cr P-C117 e'i fa- /76 TRANSMISSION VERIFICATION REPORT DATE J I ME FAX NO./NAME DURATION PAGE(S) RESULT MODE TIME 03/30/2006 21:42 NAME COCS DEVELOPMENT SER FAX 9797643496 TEL 9797643570 SER.# BROE2J341073 03/30 21:41 919723931423--170 00:01:16 02 OK STANDARD CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / fax 979.764.3496 IFACSMULE COVER SB EET Date: Al a re, In I 1 ,;1-o r-> 4 I # of pages including raver: :2— lfyou did not r ivc a complete fax, phase cd] our of lm imm &a&y fora new tt=smgtW TO: mr. PAX: 2 7 2- , 3 9 3" 1(-1 2-3 COMPANY: FM /' f / 1I q ,R�� � �� ff ! 1��- �� � �d ft- �+�I�t 61.7� '� t ( � l 7­�C 1Cdr- S 5•u.l1�fa /. �9 � FROM: _._ COMPANY:__- City af-Collexe Station, Develomnent Servicpq CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: Na vc A 3 l ,Zoo G # of pages including cover: Z- Ifyou did not rieceive coa plete fax, please call our office immediately fora new transmittal. TO: Me- Detih,'f T. A4,'fGLie// COMPANY: FAX: S t? -- (! 8 3—? 3 7 7 RE: G - C,' 's 1p�-�--za (0 � he pe., Pl% _ ,t ` z� I L7 � FROM: COMPANY. City of College Station, Development Services REMARKS: ❑ Urgent ErFor your review ❑ Replay ASAP FYI z4 it e' TRANSMISSION VERIFICATION REPORT TIME 03/30/2006 21:36 NAME COCS DEVELOPMENT SER FAX 9797643496 TEL 9797643570 SER.# BROE2J341073 DATE DIME 03/30 21:36 FAX NO./NAME 918174837377--170 DURATION 00:00:40 PAGE(S) 02 RESULT OK MODE STANDARD ECM CITY of COLLEGE STATION DEVELOPMENT SERVICES 110.1 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.8570 / Fax 979.764.3496 FACSIMILE OVER SB EET Date: Ma�-cG7 31 # of pages including cover:2- J4yuu &d not receive a comp -WO fax, please call Our aff1ca imma&fifdjr for a now fr nmjiW TO: Me- pew7" +'r 7- A4,16LH FAX: S d 93 COMPANY: Lf� ` I' I5 pf'.j- A "tf' P4-1-1 r-119" 19 C9 I r-e- Wa s Ar'-e, FROM: r+hi� Rs A wra .. CITY OF COLLEGE STATION Building Inspection Department Received LIXX6/06 Reviewed April 17, 2006 Mr. Benjamin McCarty Commercial Plans Examiner City of College Station Development services 1101 Texas Avenue South PO Box 9960 College Station, TX 77842 DESIGN ASSOCIATES 260 North Denton Tap Road Suite 255 (972(393-6255 Coppek TX 75019 Fax (972(393.1423 Re: CiCi's Pizza, #189 Relocation, Wolf Pen Plaza, 1901 S Texas Avenue, Suite A & B, College Station, TX 77804 Dear Mr. McCarty, This letter is in response to your department's comments dated March 15, 2005 regarding the above referenced project. -We have numbered our responses to coordinate with that of your comment letter. Thank you for informing us of the Landlord's deficiencies regarding the dumpster enclosures. We have informed them of your comments. They should be contacting you soon to remedy the situation. Please see sheet EI for the exterior emergency exit discharge lighting shown on the plan and on the lighting legend. Please see sheet M2 for the new pizza exhaust hood specifications. N&M ON.- f✓ The wall and ceiling systems near the two Type I exhaust hoods are constructed of non combustible pvItWI /T materials. Each exhaust hood is vented through its own exhaust duct through the roof to best comply with the 2003 IMC section 506.3.6. Please see sheet Al (Door Schedule) for egress statement on storefront doors. Please see sheet E2 for exterior main disconnect clarification. )V0M01 N �.� The fire sprinkler/fire alarm plans will be submitted for approval (under separate contract) prior to er t or installation. There are no chemical water softening devices specified for this project. The underground water supply lines specified for this project shall be Type K Copper. Please see attached lighting and mechanical compliance forms. The TAS number for this project is EABPRJA6813798 The fire extinguisher placement is to be determined in the field by the inspector from the fire marshals office. The Tenant's General Contractor (TGC) has been instructed in the plans to place them per the fire marshals instructions. The TGC is to provide a minum of two (2) type 2A-IOBC fire extinguishers. Thank you for your help. If you have any questions or need further information, please call. Permit # Permit Date COMcheck Software Version 3.1 Release 1 Lighting Compliance Certificate 2003 IECC Report Date: 04/17/06 Data filename: S:\SHARED DWG\CiCi-98\College Station\CC_Coll_Sta_TX.cck Section 1: Project Information Project Title: CICI'S PIZZA #189 RELOCATION Construction Site: Owner/Agent: WOLF PEN PLAZA, 1901 S. TEXAS AVE., SUITE 1905 A & B COLLEGE STATION, TX 77840 Section 2: General Information Building Use Description by: Activity Type Project Type: Addition Activity Type(s) Floor Area Dining 2892 Kitchen 775 Kitchen 1048 Corridor, Restroom, Support Area 110 Mall, Arcade, or Atrium 479 Corridor, Restroom, Support Area 102 Corridor, Restroom, Support Area 118 Dining 572 Section 3: Requirements Checklist Interior Lighting: ❑ 1. Total actual watts must be less than or equal to total allowed watts. Allowed Watts Actual Watts Complies 5890 5229 YES ❑ 2. Exit signs 5 Wafts or less per side. Designer/Contractor. JIM BRUTON JLB DESIGN ASSOCIATES 260 N Denton Tap Road, Suite 255 COPPELL, TX 75019 972-393-6255 Exterior Lighting: ❑ 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting: low -voltage landscape lighting. Controls, Switching, and firing: ❑ 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas that must be continuously illuminated. ❑ 5. Master switch at entry to hotel/motel guest room. Page 1 of 8 ❑ 6. Individual dwelling units separately metered. ❑ 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that must be continuously illuminated; Areas that use less than 0.6 Watts/sq.ft. ❑ 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. ❑ 9. PhotocelVastronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. ❑ 10. Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement. The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The sed lighting system has been designed to meet the 2003 IECC, Chapter 8, requirements in _ ck Version 3.1 Rele e 1 to comply with the mandatWrequirts in a Require is Checldist. O . 10 I V'V) PnnGpal Lighting Designer- me Sign Date Page 2 of 8 Permit # Permit Date COMcheck Software Version 3.1 Release 1 Lighting Application Worksheet 2003 IECC Report Date: Data filename: S:\SHARED DWG\CiCi-98\College Station\CC-Coll-Sta_TX.Cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Dining 2892 0.9 2603 Kitchen 775 1.2 930 Kitchen 1048 1.2 1258 Corridor, Restroom, Support Area 110 0.9 99 Mall, Arcade, or Atrium 479 0.6 287 Corridor, Restroom, Support Area 102 0.9 92 Corridor, Restroom, Support Area 118 0.9 106 Dining 572 0.9 515 Total Allowed Watts = 5890 Section 2: Actual Lighting Power Calculation A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. .Dining Area _ T8 / T12 Fluorescent 1: A: 2x4 Fluor. lay -in / 48" T8 32W / Electronic 3 16 96 1536 T8 / T12 Fluorescent 2: B: 2x4 Fluor. lay -in (Nt. Lt.) / 48" T8 32W / Electronic 3 3 96 Exempt Exemption:Emergency Lighting (Automatic Control) Compact Fluorescent 1: D: Rec. Dn. Lt / Twin Tube 24/26/27W / Electronic 1 1 27 27 Incandescent 1: G: Pendant / Incandescent 75W 1 8 75 600 Incandescent 2: X-1: Exit Lt. / L.E.D. 6 2 3 Exempt Exit Signs _ • _ Kitchen 1 T8 __ _ _ _ / T12 Fluorescent 1: A: 2x4 Fluor lay -in / 48" T8 32W / Electronic 3 7 96 672 T8 / T12 Fluorescent 2: B: 2x4 Fluor. lay -in (Nt Lt.) / 48" T8 32W / Electronic 3 1 96 96 Compact Fluorescent 1: D: Rec. Dn. It. / Twin Tube 24/26/27W / Electronic _ _ _ _ .� .._ ..� �.. _ — 1 8 27 216 `Kitchen2 _ T8 / T12 Fluorescent 1: A: 2x4 Fluor. lay -in / 48" T8 32W / Electronic 3 14— 96 1344 Incandescent 2: X-1: Exit Lt. / L.E.D. 6 1 3 Exempt Exit Signs Corridor Incandescent 2: X-1: Exit Lt. / L.E.D. 6 1 3 Exempt Exit Signs T8 / T12 Fluorescent 1: A: 2x4 Fluor. lay -in / 48" T8 32W / Electronic 3 2 96 192 Game Rm. Compact Fluorescent 1: D: Rec. Dn. Lt / Twin Tube 24/26127W / Electronic 1 6 27 162 TTollet Rm.1 - T8 / T12 Fluorescent 3: A: 2x4 Fluor. lay -in / 48" T8 32W / Electronic y ___. 3 2 96 _ 192 'Toilet Rm.2 _ - - , .- -- T8 / T12 Fluorescent 3: A: 2x4 Fluor. lay -in / 48" T8 32W / Electronic 3 2 96 192 Total Actual Watts = 5229 Page 3 of 8 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 5890 Total Actual Watts = 5229 Project Compliance = 661 Page 4 of 8 Permit # Permit Date COMcheck Software Version 3.1 Release 1 Mechanical Compliance Certificate 20031ECC Report Date: 04/17/06 Data filename: S:\SHARED DWG\CiCi-98XCollege StationXCC_Coll_Sta_TX.cck Section 1: Project Information Project Title: CICI'S PIZZA#189 RELOCATION Construction Site: Owner/Agent: WOLF PEN PLAZA, 1901 S. TEXAS AVE., SUITE 1905 A & B COLLEGE STATION, TX 77840 Section 2: General Information Building Location (for weather data): College Station, Texas Climate Zone: 4b Heating Degree Days (base 65 degrees F): 1788 Cooling Degree Days (base 65 degrees F): 2776 Project Type: Addition Section 3: Mechanical Systems List Designer/Contractor. JIM BRUTON JLB DESIGN ASSOCIATES 260 N Denton Tap Road, Suite 255 COPPELL, TX 75019 972-393-6255 Quap18Y System Ty &�Degcrintion 4 HVAC System 1: Heating: Central Furnace, Gas / Cooling: Rooftop Package Unit, Capacity >=135 - <240 kBtu/h, Evaporatively Cooled Condenser / Single Zone Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : ❑ 1. Newly purchased heating equipment meets the heating efficiency requirements ❑ 2. Equipment minimum efficiency: Rooftop Package Unit: 10.8 EER ❑ 3. Integrated air economizer required - Exception: Minimum cooling equipment efficiency. 9.9 EER Generic Requirements:. Must be met by all systems to which the requirement is applicable: ❑ 1. Load calculations per 1997 ASHRAE Fundamentals ❑ 2. Plant equipment and system capacity no greater than needed to meet loads - Exception: Standby equipment automatically off when primary system is operating - Exception: Multiple units controlled to sequence operation as a function of load ❑ 3. Minimum one temperature control device per system ❑ 4. Minimum one humidity control device per installed humidification/dehumidification system ❑ 5. Thermostatic controls has 5 degrees F deadband - Exception: Thermostats requiring manual changeover between heating and cooling ❑ 6. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2-hour occupant override, 10-hour backup - Exception: Continuously operating zones - Exception: 2 kW demand or less, submit calculations ❑ 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow >3,000 cfm Page 5 of 8 . ❑ 8. Outside -air source for ventilation; system capable of reducing OSA to required minimum ' ❑ 9. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between duds and the building exterior when ducts are part of a building assembly - Exception: Duds located within equipment - Exception: Duds with interior and exterior temperature difference not exceeding 15 degrees F. ❑ 10. Duds sealed - longitudinal seams on rigid duds; transverse seams on all ducts; UL 181A or 181E tapes and mastics - Exception: Continuously welded and locldng-type longitudinal joints and seams on duds operating at static pressures less than 2 inches w.g. pressure classification ❑ 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment ❑ 12. Operation and maintenance manual provided to building owner ❑ 13. Balancing devices provided in accordance with IMC 603.15 ❑ 14. Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The pr d mechanical systems have been designed to meet the 2003 IECC requirements in COMcheck n 3.1 Release 1 and to mpl with the mandatory requement in the R quirements Ch list. Principal Mechanical Designer -Name Sig ure Dat Page 6 of 8 look COMcheck Software Version 3.1 Release 1 Mechanical Requirements Description 2003 IECC Report Date: Data filename: SASHARED DWQCiCi-98\College Station\CC_Cdl_Sta_TX.cck The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: HVAC System 1 : The specified heating equipment is covered by Federal minimum efficiency requirements. New equipment of this type can be assumed to meet or exceed ASHRAE 90.1 Code requirements for equipment efficiency. The specified heating and/or cooling equipment is covered by ASHRAE 90.1 Code and must meet the following minimum efficiency: Rooftop Package Unit: 10.8 EER An integrated air economizer is required for individual cooling systems over 65 kBtu/h in the selected climate. An integrated economizer allows simultaneous operation of outdoor -air and mechanical cooling. - Exception: An economizer is not required because high -efficiency air-conditioning equipment has been specified. To qualify, the air conditioner must meet the following minimum efficiency: 9.9 EER Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling bads for the building must be determined using procedures equivalent to those in Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible, within available equipment options. - Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. - Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or doling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degrees F deadband (a range of temperature where no heating or cooling is provided). - Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between heating and cooling. 6. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a) capable of setting back temperature to 55 degrees F during heating and setting up to 85 degrees F during coolingb) capable of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10 hours without poorer. - Exception: A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously. - Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or less. 7. Outdoor -air supply systems with design airflow rates >3,000 cim of outdoor air and all exhaust systems must have dampers that are automatically closed while the equipment is not operating. 8. The system must supply outside ventilation air as required by Chapter 4 of the International Mechanical Code. If the ventilation system is designed to supply outdoor -air quantities exceeding minimum required levels, the system must be capable of reducing outdoor -air flow to the minimum required levels. 9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces (spaces neither heated nor cooled) must be insulated with a minimum of R-5. Unconditioned spaces include attics, crawl spaces, unheated basements, and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when located outside the buikiing.c) When ducts are located within exterior components (e.g., floors or roofs), minimum R-8 insulation is required only between the dud and the building exterior. - Exception: Duct insulation is not required on duds located within equipment. Page 7 of 8 Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15 degrees F. 10. All joints, longitudinal and transverse seams, and corfnections in ductwork must be securely sealed using weldments; mechanical fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and labeled in accordance with UL 181A or UL 181B. - Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification. 11, Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution equipment, including multiple -zone terminal units. 12. Operation and maintenance documentation must be provided to the owner that includes at least the following iniormation:a) equipment capacity (input and output) and required maintenance actionsb) equipment operation and maintenance manualsc) HVAC system control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions; desired or field -determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, in programming commentsd) complete narrative of how each system is intended to operate. 13. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mixing box) must have its own balancing device. Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices, and supply air diffusers. 14. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions: - Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height above grade. - Ventilation systems serving unconditioned spaces. Page 8 of 8