PREPARED 1/04/07, 12:00:16 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/04/07
-------------------------------------------------------------------------------------------------
ADDRESS . : 2021 OAKWOOD TRL SUBDIV: SANDSTONE
CONTRACTOR 2-D HOMES PHONE (979) 774-1257
OWNER HIGGINS, MARK S & TERRI L PHONE
PARCEL 560500-0002-0080
APPL NUMBER: 06-00000916 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/12/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
4/12/06 AP April 12, 2006 8:24:19 AM bkorthauer
afternoon
04/12/2006 02:36 PM RH PDA
Strings up, slab ground installed.
B115 01 6/27/06 RH BLDG, FRAMING TIME: 17:00
6/27/06 AE June 27, 2006 11:28:38 AM glsouth
06/27/2006 04:37 PM RH PDA
Need fireblocking for a/c duct chases before insulation
inspection. Finish fireplace chase on right side of house.
B130 01 8/08/06 JGM BLDG, INSULATION TIME: 17:00
1 6 AP August 8, 2006 11:41:11 AM bkorthauer
B12t,:01 1/04/07 BI BLDG, FINAL TIME: 17:00
ij January 4, 2007 8_,32:34 AM ncochran.
driveway cannot be completed - contractor spoke wiEh' cliris
about this, so call_him_if you have any questions
-------------------------------------- COMMENTS AND NOTES --------------------------------------
I o�
10/x
/�
Kim 1Nolfe - Re: Calling for C.O. @ 2021 Oakwood Trail Page 1
From: Terry Boriskie
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wolfe; Mitchell
Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie
Date: 1/4/2007 4:18:24 PM
Subject: Re: Calling for C.O. @ 2021 Oakwood Trail
Victor Drozd with 2D Homes at 774-1257 has been notified.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Joe Garcia 1/4/2007 3:33 pm >>>
THE SEWER BOX IS BROKEN, AND WILL NEED TO BE REPLACED. THE WATER METER BOX IS
OK. JMG
>>> Gina Southerland 01/04/07 12:07 PM >>>
BP# 06-916
Gina Southerland
Customer Service Rep.
City Of College Station
1101 Texas Ave.
979-764-3570
glsoutherland(cDcstx.gov
Date: 1 /4/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 916
Address: 2021 OAKWOOD TRL
Insp.
Inspection Type Code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
04/12/2006 02:36 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
6115
BLDG, FRAMING
IC
06/27/2006 04:37 PM RH PDA
6115
BLDG, FRAMING
IC
Need fireblocking for a/c duct chases before insulation
6115
BLDG, FRAMING
IC
inspection. Finish fireplace chase on right side of house.
Page 1
WF0756890 / 001 City of College Station" PAGE 1-
REQ. DATE: 03/31/06 03/31/06 13:22:31
LOCATION: 2021 OAKWOOD TRL LOC ID: 190078
REQUESTOR: 2-D HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/31/06 SCHED COMPLETION: 03/31/06
********************************************************************************
JOB ORDER RESULT COMVIENI'S
WF0756370 /
001 City of Collgge
Station
PAGE 1
REQ. DATE:
03/29/06
03/29/06
16:20:08
LOCATION:
2021 OAKWOOD TRL
LOC ID:
190078
REQUESTOR:
2 D HOMES
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
03/29/06 SCHED
COMPLETION:
03/29/06
********************************************************************************
JOB ORDER RESULT COM4MTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 1/09/07
Parcel Number . . . .
. 560500-0002-0080
Property Address . .
. 2021 OAKWOOD TRL
COLLEGE STATION TX 77845
Subdivision Name . .
. SANDSTONE
Legal Description . .
. SANDSTONE, BLOCK 2, LOT 8, ACR
ES 1.81
Property Zoning . . .
. RURAL RESIDENTIAL SUB.
Owner . . . . . . . .
. HIGGINS, MARK S & TERRI L
Contractor . . . . .
. 2-D HOMES
979 774-1257
Application number
06-00000916 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . .
. COMBUSTIBLE (UNPROTECTED)
Occupancy type . . .
. RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . .
.
Approved . . . . . . . I., k440 1,
Bui= fig ODf t icil
VOID UNLESS SIGNED BY BUILDING OFFICIAL
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
T E M P O R A R Y C O
T E M P O R A R Y
Issue Date . . . . . .
Expiration Date . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description
Property Zoning .
Owner . . .
Contractor
1/04/07
1/19/07
560500-0002-0080
2021 OAKWOOD TRL
COLLEGE STATION TX 77845
SANDSTONE
SANDSTONE, BLOCK 2, LOT 8, ACR
ES 1.81
RURAL RESIDENTIAL SUB.
. HIGGINS, MARK S & TERRI L
2-D HOMES
979 774-1257
Application number 06-00000916 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone
Special conditions
Need address on mailbox
Need permanent driveway installed
Approved . .
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT_
CITY OF C"'QL�E STATION
1101.TEAS AVE
COLLEGE STATII
TEXAS
TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000916 Date 3/29/06
2021 OAKWOOD TRL
560500-0002-0080
R108796
RESIDENTIAL, 1 UNIT DETACHED NEW
SANDSTONE
RESIDENTIAL
AGRICULTURAL OPEN
289700
Owner Contractor
HIGGINS, MARK S &
TERRI L 2-D HOMES
TOMLIN
2702 WILDFLOWER A
2008 SPRING CRK
BRYAN
TX 77802
COLLEGE STATION
TX 778454605 (979) 774-1257
--- Structure Information 000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3869.00
INTERIOR WALL TYPE
DRYWALL
NUMBER OF BATHROOMS
4.00
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
TAZ
351.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
KW
Permit Fee
1030.00 Plan Check Fee
.00
Issue Date . . .
. 3/29/06 Valuation . .
. . 289700
Expiration Date .
. 9/25/06
Qty Unit Charge Per Extension
BASE FEE 460.00
190.00 3.0000 THOU BLDG, VAL 100001-500000 570.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
---------------------------------------------- ---- -� ---,; - - ----------
BUILDING DEPOT'^ PRESENTATIVE:
APPLICANT:/
BUILDING PERMIT
CITY OF QOLLE7E STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00000916 Date 3/29/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
--------------------------------------- - - - - -- - - - -
-_--.AdAw-----------
BUILDING DEPT R RESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF 'QOLLEyE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00000916 Date 3/29/06
----------------------------------------------------------------------------
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
--------------------------------------------- ---- - •----------
BUILDING DEPTT SENTATIVE:
APPLICANT: /7/
BUILDING PERMIT
CITY OF COLLEGE STATION
1161 TEXAS AVE
COLLEGE STATION, 7X 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . .
06-00000916 Date
3/29/06
----------------------------------------------------------------------------
Special Notes and Comments
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING,, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
Narrow Wall Bracing Prescriptive OSB and Interior Anchors
along with Simpson Engineered
Panels.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 1030.00
1030.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1780.00
1780.00 .00
.00
------------------------------------------- ----A
-- ---------------
BUILDING DEPT REPR ENTATIVE: .sue
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF'COLLEgE STATION
1161 TEXAS AVE
COLLEGE STATION, tX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000917
2021 OAKWOOD TRL
560500-0002-0080
TEMP POLE
SANDSTONE
RESIDENTIAL
AGRICULTURAL OPEN
0
Owner Contractor
Date 3/29/06
HIGGINS, MARK S &
TERRI L
2-D HOMES
TOMLIN
2702 WILDFLOWER A
2008 SPRING CRK
BRYAN
TX 77802
COLLEGE STATION
TX 778454605
(979) 774-1257
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/29/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------------------------------- ---- --------
zoww
BUILDING DEPT" PRESENTATIVE: --
APPLICANT:
• �f.
CITY OF COLLEGE STATION
Planning cr Development Srruias
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION '
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRESS/LOCATION: 2021 Oakwood Trail, College Staion
LOT 8 BLOCK _ � _ SUBDIVISION SANDSTONE
SEC/PH REPLAeT
only
DATE:3b1T(5TRCC REG
APPLICATION # lX
TEMP POLE # VC `�l
BUSINESS/OWNER NAME: 2D Homes PHONE:
CONTRACTOR/HOMEOWNER: 2D Homes
CONTRACTOR ADDRESS: 4236 BOONVILLE RD, BRYAN 77802
ELECTRICIAN: Gilmoore
PLUMBER: Cascade
PHONE:774-1257
HVAC: Climate Masters GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION" SWIMMING POOL
Required)
DESCRIPTION OF WORK: New Residence
STRUCTURE USE: RESIDENCE
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $289700.00 TOTAL AREA:5308 HEATED AREA: 3869 _
(Cost of Labor and Materials)
PUBLIC SEWER
G" SEPTIC/TREATMENT SYSTEM
SEWER TAP: 4°
SIZE
�( EX WATER TAP: "
SIZE
/f t
OTHER TAP:
F TEMP POLE SIZE
GARAGE TYPE: SINGLE
ATTACHED
NUMBER OF BEDROOMS: C
NUMBER OF BATHROOMS: 4
INTERIOR WALL TYPE: DRYWALL
EXTERIOR WALL TYPE: BRICK STOOCO
FOUNDATION TYPE: SLAB ON GRADE
ROOF TYPE: COMP
DOUBLE F-A-1 TRIPLE a
IETACHED F_� CARPORT a
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
3 -z�v6
r � SA vps�.Sas
C ments:
ES r NO
M
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
14
13
30
.38 ""/
.38
6
14 `/
CITY OF COLLEGE STATION
Planning 6- Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER#
DATE: 3 /aY/o,6
BUILDING ADDRESS: Z Oak wo
I. Foundation Requirements
NA/OK
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier
1. 6 mil poly
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OK
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Narrow Wall Bracing Methods indicated on plans
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M.
N.
Span exceeding code tables must be engineered
Rafters sizes, spacing, grade, slope and purlins if required.
(*hrq"
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/OK
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
NA/OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
V. Electrical Service Requirements
NA/OK
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NA/OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
NA/OK
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NA/OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/OK
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/OK
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
NA/OK
Does not block any water course or divert any flow
Elevation certificate if required
'4
(*f/q5t
CITY OF COLLEGE STATION
Planning er Development Services
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
2021 OAKwooD TRAIL
40
3
N
7
IU
m
IN
O
O
(n
N
$
M
ri
O
3
m
U)
m
co
m
to
am
m
m
`AN.
�w
2021 OAKWOOD TRAIL
3
i1
�
N
G
2
O
3
m
-a
NotREScheck Software Version 3.7.3
Compliance Certificate
Project Title: HIGGINS/TOMLIN RESIDENCE
Report Date: 03/27/06
Data filename: C:\Program Files\Check\REScheck\HIGGINS.rck
Energy Code: 20001ECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 14%
Heating Degree Days: 1788
Construction Site:
2021 Oakwood Trail
College Station, TX 77845
Owner/Agent:
Mark/Terri Higgins/Tomlin
2008 Spring Creek
College Station, TX 778045
979-693-0217
Permit #
Permit Date
Designer/Contractor:
Victor Drozd
20 CONSTRUCTION CO. INC.
4236 Boonville Rd
Bryan, TX 77802
979-774-1257
vdrozd@2dhomes.com
Compliance: Passes Maximum UA: 1364 Your Home UA 938 --> 31.2% Better Than Code (UA)
Maximum SHGC: 0.40 Your SHGC: 0.38
Ceiling 1: Flat Ceiling or Scissor Truss:
Wall 1: Wood Frame, 16" o.c.:
Window 1: Vinyl Frame:Double Pane with Low-E:
SHGC: 0.38
Door 1: Solid:
Door 2: Glass:
SHGC: 0.37
Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0'
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 14 SEER
3869 30.0
0.0 135
4316 13.0
0.0 300
385
0.380 146
40
0.400 16
235
0.310 73
257
0.0 268
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
RESc Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
-�7-o L
wilder/Designer Company Name Date
HIGGINS/TOMLIN RESIDENCE
Page 1 of 4
A
REScheck Software Version 3.7.3
Inspection Checklist
Date: 03/27/06
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.380
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.400
Comments:
❑ Door 2: Glass, U-factor: 0.310
Comments:
Floors:
❑ Floor 1: Slab -On -Grade: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air: 80 AFUE or higher
Make and Model Number:
❑ Air Conditioner 1: Electric Central Air: 14 SEER or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be
determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Materials Identification:
❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building
plans or specifications.
Duct Insulation:
HIGGINS/TOMLIN RESIDENCE
i -
Page 2 of 4
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
HIGGINS/TOMLIN RESIDENCE
Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and
Runouts
Heated Water
Temperature (°F)
Up to 1"
Up to 1.25"
1.5' to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
Piping System Types
Range(°F)
2" Runouts 1" and Less
1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
HIGGINS/TOMLIN RESIDENCE
Page 4 of 4