Loading...
HomeMy WebLinkAboutRES2006-00910, 06-911OP6ndafie,Y'" /3Esselte R 7521/3 10% P4 J PREPARED 8/28/06, 11:58:29 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/28/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 910 WHITEWING LN SUBDIV: DOVE CROSSING CONTRACTOR D R HORTON HOMES PHONE (512) 748-4017 OWNER . . PHONE PARCEL . . 005401-0104-0060 APPL NUMBER: 06-00000910 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/11/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 I' 4/11/06 AP T/S: 04/10/2006 10:37 AM GLSOUTH ----------------------- morning 04/11/2006 12:02 PM RH PDA Slab ground installed. Slab survey on file. B115 01 5/26/06 JGM BLDG, FRAMING TIME: 17:00 1 5/26/06 DP May 25, 2006 3:13:55 PM kwolfe 05/26/2006 11:10 AM JGM PDA need to reinstall electrical at front door, draft stop ac chases, need joist hangers in bedrooms upstairs, need to nail second floor sole plate with 16d nails 16 inch o.c. B11' .02 6/05/06 JGM BLDG, FRAMING TIME: 17:00 6/05/06 AP June 2, 2006 9:56:07 AM glsouth AFTERNOON B130 01 6/05/06 JGM BLDG, INSULATION TIME: 17:00 6/05/06 AP June 2, 2006 9:56:22 AM glsouth AFTERNOON B125 01 8/23/06 RH BLDG, FINAL TIME: 17:00 8/23/06 CA August 23, 2006 10:54:46 AM glsouth B125 02 8/28/06 BI BLDG, FINAL TIME: 17:00 August 28, 2006 10:58:17 AM kwolfe -------------------------------------- COMMENTS AND NOTES ---- --------------------------------- A a o� Date: 8/29/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 910 Address: 910 WHITEWING LN Insp. inspection Type Code Description p. status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 04/11/2006 12:02 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Slab ground installed. Slab survey on file. B115 BLDG, FRAMING IC 05/26/2006 11:10 AM JGM PDA B115 BLDG, FRAMING IC need to reinstall electrical at front door, draft stop ac B115 BLDG, FRAMING IC chases, need joist hangers in bedrooms upstairs, need to B115 BLDG, FRAMING IC nail second floor sole plate with 16d nails 16 inch o.c. E150 ELEC, FINAL IC 08/04/2006 03:42 PM RH PDA E150 ELEC, FINAL IC Garage plug not GFI protected. Master bedroom has open E150 ELEC, FINAL IC neutral. Need cover plate on outlet in back bedroom. M110 MECH, FINAL IC 08/03/2006 12:01 PM OC PDA M110 MECH, FINAL IC sheetrock return air. need 12 inches from top & bottom. M110 MECH, FINAL I IC finish installing unit. Page 1 WF0756385 / 001 City of College Station It PAGE 1 REQ. DATE: 03/29/06 `Rtt 03/29/06 16:46:55 LOCATION: 910 WHITEWING LN LOC ID: 202838 REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/29/06 SCHED COMPLETION: 03/29/06 ******************************************************************************** JOB ORDER RESULT COM 4MTS Apr. 11, 2006 11:18AM Strong Surveying No, 1623 P. 4 V22 Broadmoor, Sacks 'I S TRONG Texas ii802 URVEYING p aX (9n) 731-00 6 L Fa�c (979) 737'oo9b ema& curds0s&mgsu►veyd19com FORM CHECK d North Orientation Is based on rototing The TBM Elevation Shown hereon is the NorthEast line to the Plat Calls In based on the Grading Plan Prepared by Volume 6968, Page 35, Texcon. SCALE: 1 = 20' 1/2' Iron Rod W/cap found at all corners, unless otherwise noted. LEGEND All bearings and distances are Call and Actual. P.U.E. —Public Utility Esmt. F.F. — finished Floor LOT 36(Phase IB) LOT 37(Phase IB) LOT 38(Phose IB) S 41.55'21" W 55.0 ' 10' P.U.E.(6968/35) r 20' Building Setback o � 10,0' � O O ' O . r� 8.O' ,a ....... N ......... — 14.7' 7.8' w s 0.80, x 3 p l Lot 6 I M M m u fn N ? Lot 7 0 Lot 5 OD <V Ui v FORM e CDFM o = F.F. = 311.70' m Min. F.F. = 309.3' 1 ro i0.a' B.0' 25' Building Setback cyi N: 5' P.U.E.1$968/35l N 41.55'21" E 55.00' F �P. •;g•E • 910 Whitewing Lane A Title Commitment was not H RA `^ available the time of this 4961 �F•' (il � survey, therefore only easements shown on the Record Subdivision 9•��; Fss���y� Plat are indicated on this plot. ° SUR BUYER: Lot Six(6), Block Four(4) of Dove Crossing Subdivision, an addition to the City of College Station, Brazos County, TEXAS according to the plot recorded in Volume 6968, Page 35 of the Official Records of Brazos County, Texas. I, H. Curtis Strong, Registered Professional Land Surveyor No, 4961, do hereby certify that the above plat is true and correct and represents the results of a survey performed on the ground under my supervision on April 10, 2006. 1 further certify that no improvements on this property encroach on adjacent property nor do any improvements on adjacent property encroach on this property, except as shown. This property is not located within a 100 — year flood hazard area as depicted from FLOOD INSURANCE RATE MAP NO.48041CO201 C , DATED: JULY 2, 1992. This Plat is copyrighted in 2006, and is for the sole purpose of the buyer as shown. Any other use is strictly prohibited without the express written consent of Strong Surveying. BUIL,DING PERMIT CITY `�-e0LLEGE STATION 1161 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000910 Date 3/29/06 Property Address . . . . . . 910 WHITEWING LN Property ID: 005401-0104-0060 R #: R13907 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 153846 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES :12554 RIATTA,VISTA CIRCLE 'SECOND FLOOR AU, � T I-N1-----z----, TX 78727 (512_)_ 748-4017 --- Structure Information 000 000 Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID PAID FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2331.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 622.00 Plan Check Fee .00 Issue Date . . . . 3/29/06 Valuation . . . . 153846 Expiration Date . . 9/25/06 Qty Unit Charge Per Extension BASE FEE 460.00 54.00 3.0000 THOU BLDG, VAL 100001-500000 162.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ------------------------------------------- ------ ------:---------------- BUILDING DEPT REPRES NTATIVE: • APPLICANT: BUILDING PERMIT CITY'OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 06-00000910 Date 3/29/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUIJING ENVELOPE SHALL ------------------------------- - ---•- -'----------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY'OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000910 Page 3 Date 3/29/06 Special Notes and Comments BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ------------------------------------------- ------ ---- -------_------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY'OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000910 Date 3/29/06 ---------------------------------------------------------------------------- Special Notes and Comments GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Narrow wall bracing Engineered Bracing Methods. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ----------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- ---------- Due --------------------------- Permit Fee Total 622.00 622.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1372.00 1372.00 .00 .00 ------------------------------------------------ --- - -- ------------ BUILDING DEPT REPR/E'S�ENTATIVE: APPLICANT: / `�' Z- PL TEMPORARY POLE PERMIT CITY'OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000911 Date 3/29/06 Property Address . . . . . . 910 WHITEWING LN Property ID: 005401-0104-0060 R #: R13907 Application type description TEMP POLE Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATTA VISTA CIRCLE SECOND FLOOR AUSTIN TX 78727 (512) 748-4017 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date . . . . 3/29/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - I'IAY-18-2004 02:21 From: To:512 21e 4299 P.3/4 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE S['A ON (979) 764-3570 (879) 764.3496 FAX PLnrjNr � Ihrtx(apmml Snwia W W W,GSTX.GOV ADDRESS/LO TION:TO Paf omce um o dy �2,11a&QCREQHATE: -� APPLICATION # t ` " 1II V TEMP POLE # - 61 6 vo LOT _-6--Z BLOCK SUBDIVISION p o SEC/P't t BUSINESS/OWNERNAME:o �(�✓� PHONE:,5Ia 533�I`l0� CONTRACTOR/HOMEOWNER: �$��p PHONE' _5( a.- 5 3.1 - / /0 CONTRACTOR ADDRESS: lL� s�y U/S `!"rc Lam- �S fjJ,� 7X 78 }a,�, ELECTRICIAN: (Z Lio& PLUMBER: vs drrt Ui1.1r1 GOOD CENTS (Residential on(y): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION OVIN.G SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION = SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION' SWIMMING POOL Required) 11 DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ARCH �L OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS A SSIBILITf STANDARD (TAS)�ltO.iECT ISTF,TR9N# EABARJ VALUA ON: $ // YOTAL AREA �L r� TED AREA: ��JI (Cost of Lab r and 2(PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENY SYSTEM NUMBER OF BATHROOMS: �• DZSEWERTAP: I ` INTERIOR WALL TYPE: S� SIZE WATER TAP: it EXTERIOR WALL TYPE: I(j�ct,so -I (✓� SRt: OTHER TAP: FOUNDATION TYPE; in oT _ SIZE t/ TEMP POLE ROOF TYPE: C0.11 p S i GARAGE TYPE: SINGLE a DOUBLE a TRIPLE ATTACHED DETACHED F__j CARPORT SIGNATURE OF APPLICANT' *If proposed work involves new comn Ial construction or facade improvements/renovations to an existing commercial property, building el a ions are required. Offlclal Use Only 3 — U -0 Plans Examiner ✓°�� .4/w Zoning Official C ments: YES 0r,�N0 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning cr Development Services PLAN REVIEW/PERMIT NUMBER# _ 1! p DATE: BUILDING ADDRESS: o tAJ • I. Foundation Requirements NA/ K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated Iq" II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. (*hrq" CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes ✓i III. Stairway Requirements NAIW A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location Vl. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy Requirements NA/ A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed AAA - Street Ordinance Requirements Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 WOK Does not block any water course or divert any flow Elevation certificate if required %�� CITY OF COLLEGE STATION Planning d Development Services Comments: PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 3 - -2-,f DATE