HomeMy WebLinkAboutRMDL2006-00897C�(Q PF 6q�1 OPendaftenr /3Esselte R 7521/3 10% P4 I- PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning er Development Services PLAN REVIEW/PERMIT NUMBER# 06_5?9 1 DATE: 3 /a7lo6 BUILDING ADDRESS: p r ) 92ft. I. Foundation Requirements OK A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW (*hrq" ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NAr 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes 1-1 III. Stairway Requirements fflVOK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6- Development Services V. Electrical Service Requirements N K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N OK A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements (NAJOK A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 OK Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements OK Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side (intersecting) street 10K Subdivision Regulations — Ordinance 690 Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 FOK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning & Development Services Comments: NS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS �-L`7 -afo DATE BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 --------------------------------------L------------------------------------ Application Number . . . . . 06-00000897 Date 3/27/06 Property Address . . . . . . 704 CANTERBURY DR Property ID: 144700-0011-0030 R #: R87900 Application type description RESIDENTIAL, REMODEL & RENOVATION Subdivision Name . . . . . . BRANDON HEIGHTS Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 67821 Owner Contractor ------------------------ LAWLER, JAMES THOMAS ------------------------ & MARY MARIOTT HOMES INC 704 CANTERBURY DR LARRY MARIOTT COLLEGE STATION TX 778457902 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 (979) 696-1787 --- Structure Information 000 000 REMODEL/RENOVATION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 3067.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 332.00 Plan Check Fee .00 Issue Date . . . . 3/27/06 Valuation . . . . 67821 Expiration Date . . 9/23/06 Qty Unit Charge Per Extension BASE FEE 260.00 18.00 4.0000 THOU BLDG, VAL 50001-100000 72.00 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPE AL KNOWLEDGE/EFFORT ANY CHANGES OR ALTERATIONS TO SUBMITT PLANS/4US�T4" / . BUILDING DEPT_.&.ZPRESEN-TATIVE : _ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------------r--------------------------------- Page 2 Application Number . . . . . 06-00000897 Date 3/27/06 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total Plan Check Total Grand Total BUILDING DE APPLICANT: 332.00 332.00 .00 .00 .00 .00 .00 .00 332.00 332.00 .00 .00 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: /D LOT _ j BLOCK �� SUBDIVISION BUSINESS/OWNER NAME: CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: ELECTRICIAN: Zi0/i Or:lE HVAC: 4,114 — II r c or Office Use Only DATE: Q APPLICATION # D Q TEMP POLE # SEC/PH PHONE: -1-75- 3.363 PLUMBER: /d z r. A.&_ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION ADDITION MOVING DEMOLITION (Asbestos Survey) NEW CONSTRUCTION DUPLEX (Landscape Plans REMODEL/RENOVATION Required) 9 DESCRIPTION OF WORK: 1,1104i0erplat'_ kl jtit " � 4 C�1,a«� /3�•,ris oti- /-'iiPS'�' %'tod+.C�'. S RUCTURE USE: RE -ROOF (Total/Partial) SHELL ONLY SLAB ONLY SWIMMING POOL rr/ , _ f t /) r / /. HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVW COM fEMITTEEAPPROVAL: mil/ TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ .47, W, Oy TOTAL AREA17A-.!r- HEATED AREA: 30 6 % (Cost of Labor and Materials) PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: WATER TAP: ❑ OTHER TAP: TEMP POLE GARAGE TYPE: V ILC SIZE SIZE SINGLE ATTACHED C� SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE ROOF TYPE: DOUBLE TRIPLE DETACHED n ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ Official Use Only 11 r► ents: 0(0 S r NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) , Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating r