HomeMy WebLinkAboutRMDL2006-00897C�(Q PF 6q�1
OPendaftenr
/3Esselte
R 7521/3 10% P4
I-
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning er Development Services
PLAN REVIEW/PERMIT NUMBER# 06_5?9
1 DATE: 3 /a7lo6
BUILDING ADDRESS: p
r ) 92ft.
I. Foundation Requirements
OK
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
PLAN REVIEW
(*hrq" ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NAr
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
1-1
III. Stairway Requirements
fflVOK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6- Development Services
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
(NAJOK
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
OK
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
10K
Subdivision Regulations — Ordinance 690
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
FOK
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
NS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
�-L`7 -afo
DATE
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
--------------------------------------L------------------------------------
Application Number .
. . . . 06-00000897 Date 3/27/06
Property Address . .
. . . . 704 CANTERBURY DR
Property ID:
144700-0011-0030
R #:
R87900
Application type description
RESIDENTIAL, REMODEL & RENOVATION
Subdivision Name . .
. . . . BRANDON HEIGHTS
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 67821
Owner
Contractor
------------------------
LAWLER, JAMES THOMAS
------------------------
& MARY MARIOTT HOMES INC
704 CANTERBURY DR
LARRY MARIOTT
COLLEGE STATION
TX 778457902 209 ROCK PRAIRIE RD
COLLEGE STATION TX 77845
(979) 696-1787
--- Structure Information
000 000 REMODEL/RENOVATION
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . IMPACT/PRORATA FEES PAID NA
HEATED AREA 3067.00
INTERIOR WALL TYPE SHEET ROCK
NUMBER OF BATHROOMS 4.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 1.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
332.00 Plan Check Fee .00
Issue Date . . . .
3/27/06 Valuation . . . . 67821
Expiration Date . .
9/23/06
Qty Unit Charge
Per Extension
BASE FEE 260.00
18.00 4.0000
THOU BLDG, VAL 50001-100000 72.00
----------------------------------------------------------------------------
Special Notes and Comments
ELECTRICAL SHALL BE
INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
REQUIRED EXIT DOORS
SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF
A KEY,TOOL OR SPE AL KNOWLEDGE/EFFORT
ANY CHANGES OR ALTERATIONS TO SUBMITT PLANS/4US�T4" / .
BUILDING DEPT_.&.ZPRESEN-TATIVE
: _
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------------r---------------------------------
Page 2
Application Number . . . . . 06-00000897 Date 3/27/06
----------------------------------------------------------------------------
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
BUILDING DE
APPLICANT:
332.00 332.00 .00 .00
.00 .00 .00 .00
332.00 332.00 .00 .00
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: /D
LOT _ j BLOCK �� SUBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS:
ELECTRICIAN: Zi0/i Or:lE
HVAC: 4,114
—
II
r
c
or Office Use Only
DATE: Q
APPLICATION # D Q
TEMP POLE #
SEC/PH
PHONE: -1-75- 3.363
PLUMBER: /d z r. A.&_
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION
ADDITION MOVING
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION
DUPLEX (Landscape Plans REMODEL/RENOVATION
Required) 9
DESCRIPTION OF WORK: 1,1104i0erplat'_ kl jtit "
� 4 C�1,a«� /3�•,ris oti- /-'iiPS'�' %'tod+.C�'.
S RUCTURE USE:
RE -ROOF (Total/Partial)
SHELL ONLY
SLAB ONLY
SWIMMING POOL
rr/ , _
f
t /) r / /.
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVW COM
fEMITTEEAPPROVAL: mil/
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ .47, W, Oy TOTAL AREA17A-.!r- HEATED AREA: 30 6 %
(Cost of Labor and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
❑ OTHER TAP:
TEMP POLE
GARAGE TYPE:
V ILC
SIZE
SIZE
SINGLE
ATTACHED C�
SIGNATURE OF APPLICANT:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE
ROOF TYPE:
DOUBLE TRIPLE
DETACHED
n
♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦
Official Use Only
11 r► ents:
0(0 S r NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
, Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
r