HomeMy WebLinkAboutRES2006-00893, 06-8944-fr93
4-B�IY
OPendaflor
/3 Esselte
AaX
R 7521/3 10% P4
PREPARED
5/10/07, 12:00:48
INSPECTION TICKET PAGE
2
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE
5/10/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 2005 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 1
CONTRACTOR PITCOCK & CROIX
PHONE (979) 764-7551
OWNER
PITCOCK & CROIX,
INC PHONE
PARCEL
184200-1102-0490
APPL NUMBER: 06-00000893 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
6/12/06 JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
6/12/06 AP
June 12, 2006 9:45:54 AM bkorthauer
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
8/29/06 JGM
BLDG, FRAMING TIME: 17:00
8/29/06 AE
August 16, 2006 9:16:58 AM glsouth
08/29/2006 11:26 AM JGM PDA
need to fix notes on hvac
B130 01
9/11/06 JGM
BLDG, INSULATION TIME: 17:00
9/11/06 AP
September 11, 2006 10:28:09 AM kwolfe
B125 01
5 10/07
BLDG, FINAL TIME: 17:00
May 10, 2007 8:59:37 AM kwolfe.
------------------------
-----------
COMMENTS AND NOTES --------------------------------------
,).,Kim Wolfe - Re: Callin for CO @ 2005 Ravenstone Loop„ Page 1
From: Mitchell Carson
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 5/17/2007 10:46 AM
Subject: Re: Calling for CO @ 2005 Ravenstone Loop
This one is ok Mitch
>>> Kim Wolfe 05/17/07 7:59 AM >>>
Any issues?
BP # 06-893
Thanks
Kimberly Wolfe, CPS
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.aov
Date: 5/10/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 893
Address: 2005 RAVENSTONE LOOP
Type
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
08/29/2006 11:26 AM JGM PDA
B115
BLDG, FRAMING
IC
need to fix notes on hvac
E110
ELEC, ROUGH IN
IC
08/16/2006 10:24 AM JGM PDA
E110
ELEC, ROUGH IN
IC
upstairs smoke detector needs proper clearance from a/c
E110
ELEC, ROUGH IN
IC
register
M100
MECH, ROUGH IN
IC
08/29/2006 11:26 AM JGM PDA
M100
MECH, ROUGH IN
IC
need duct for dryer in utilty room
Page 1
WF0761277 / 001 City of College Station
PAGE 1
nun nAIrV nn /1 a /nc -) I a -" 1 na /1 Q /nr l 7 • n'7 • 4n
LOCATION: 2005 RAVENSTONE LOOP LOC ID: 191086
REQUESTOR: PITCOCK & CROIX ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/19/06 SCHED COMPLETION: 04/19/06
********************************************************************************
JOB ORDER RESULT COME TTS
WF0760956 / 001 Cityra€411ege Station
PAGE 1
REQ. DATE:
04/18/06
04/18/06
14:47:58
LOCATION:
2005 RAVENSTONE LOOP
LOC ID:
191086
REQUESTOR:
PITCOCK & CROIX, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
04/18/06 SCHED COMPLETION:
04/18/06
********************************************************************************
JOB ORDER RESULT COM14ETTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 5/18/07
Parcel Number . . . .
. 184200-1102-0490
Property Address . .
. 2005 RAVENSTONE LOOP
COLLEGE.STATION TX 77845
Subdivision Name . .
. CASTLEGATE SEC 1 PH 1
Legal Description . .
. CASTLEGATE SEC 1, PHS 1, BLOCK
2, LOT 49
Property Zoning . . .
. PLANNED DEVL HOUSING
Owner . . . . . . . .
. PITCOCK & CROIX, INC
Contractor . . . . .
. PITCOCK & CROIX
979 764-7551
Application number
06-00000893 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . .
. COMBUSTIBLE (UNPROTECTED)
Occupancy type . . .
. RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . .
.
Approved
TuMdLfig Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILBI,rNG PERMIT
CITY OF -COLLEGE STATION
110f TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-35,70 FAX: (979)764-3496
----------------------------------- '------------------------------------------
Application Number .
. . . . 06-00000893
Date 4/18/06
Property Address . .
. . . . 2005 RAVENSTONE LOOP
Property ID:
184200-1102-0490
R #:
R109218
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 1 PH 1
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
. . . . 175560
Owner
Contractor
------------------------
PITCOCK & CROIX, INC
------------------------
PITCOCK & CROIX
PO BOX 10276
RANDALL PITCOCK
& MIKE CROIX
COLLEGE STATION
TX 778420276 PO BOX 10276
COLLEGE STATION
TX 77842
(979) 764-7551
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2660.00
INTERIOR WALL TYPE
SHEET ROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc
KW
Permit Fee
688.00 Plan Check Fee
.00
Issue Date . . . .
4/18/06 Valuation . .
. . 175560
Expiration Date . .
10/15/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
76.00 3.0000
THOU BLDG, VAL 100001-500000
228.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
------------------------------------ -------- ----- _�
BUILDING DEPT REPRESENTATIVE:
-----------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000893
Page 2
Date 4/18/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE a
-------------------------------------------- i--- --- r--- -�fW----- Ar-v--- -- - - - - --
BUILDING DEPT REPRESENTATIVE:
APPLICANT: /fot-x
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00000893 Date 4/18/06
----------------------------------------------------------------------------
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MU T BE TEMPERED (2003
-------------------------- ------ --•- ------------
BUILDING DEPT REPRESENTATIVE: •
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . .
06-00000893 Date
4/18/06
----------------------------------------------------------------------------
Special Notes and Comments
IRC)
RANGE/DRYER DUCT MUST COMPLY
WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS.
CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
Narrow wall bracing Fully Sheathed
with APA framing
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 688.00
688.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1438.00
1438.00 .00
.00
-------------------------------------- - - - - -
- ----- --- - -- ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-00000894
Date 4/18/06
Property Address
. . . . . .
2005 RAVENSTONE LOOP
Property ID:
184200-1102-0490
R #:
R109218
Application type
description
TEMP POLE
Subdivision Name
. . . . . .
CASTLEGATE SEC 1 PH 1
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
PLANNED DEVL HOUSING
Application valuation
. . . .
0
Owner
Contractor
------------------------
PITCOCK & CROIX,
INC
------------------------
PITCOCK & CROIX
PO BOX 10276
RANDALL PITCOCK &
MIKE CROIX
COLLEGE STATION
TX 778420276
PO BOX 10276
COLLEGE STATION
TX 77842
(979) 764-7551
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/18/06
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------✓ ---- - --•--------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
(*Orq" COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning 6- DevelopmentSemim
WWW.CSTX.GOV
ADDRESS/LOCATION:_
LOT 'V- qVBLOCK a
BUSINESS/OWNER NAME
F /fi Use Only
DATE: C REG
APPLICATION # a
TEMP POLE # 1
" SUBDIVISION ��Q�t -/� SEC/PH
PHONE:
CONTRACTOR/HOMEOWNER: /4eec" : l cG: PHONE:
CONTRACTOR ADDRESS: /�D f�/D��C��'17 R �
ELECTRICIAN: /orn.�s!le�L�� PLUMBER:
HVAC: ��Y��� GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required) ll
DESCRIPTION OF WORK: .�iGG��rn���a<.2x e)
STRUCTURE USE:
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 17'5i -5 oD TOTAL AREA:363 / HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
® WATER TAP:
OTHER TAP:
® TEMP POLE
GARAGE TYPE
SIZE
13/41�
SIZE
SIZE
SINGLE E]
ATTACHED ® /
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE n TRIPLE
DETACHED CARPORT
a/.I /.1D
SIGNATURE OF APPLICANT:
If proposed work involves new cofnmerciaf construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only ents:
�e J2 -" Z -7 ` ` 6 ES r NO
Fhv Plans Examiner Zoning Official
{ '+Gv illy IT
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Sp ✓
CITY OF COLLEGE STATION
Planning 6- Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# 06-993
DATE: 3 /9-2/ 06
BUILDING ADDRESS: o200S 2�,re*,d-s„iP 4-0
I. Foundation Requirements
NWIJ
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
11. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
1. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, rade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning c ' Development Services
Il. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
A14-
Ill. Stairway Requirements
A/
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d Development Services
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vlll. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if re uiredIJA
.f
CITY OF COLLEGE STATION
Planning cd Development Services
Comments:
L A S EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
-- 7, '? t.,O6
DATE
MAR-06-2006 06:17 AM P.02
1
jL 15' u�,ldln�llna _
I
I
cl
of �,
Foundation Outl►nm
An
..-. � 5p6CUIdtIvC RG91dG'1C® _�7 N
I
cons. apron 4' walk
12'I drive
AOS� Raverstone Loop
LOT: .4S C,ASTLEGATE PITCOCK
IBLOCK: 2 SUBDIVISION AND
SECTION: I CROI X
0 5' 10' 20' 40' 60'
SITE PLAN
SCALE: 1 "=20'